Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Elemental analysis of a comet nucleus by passive gamma ray spectrometry from a penetrator

The Comet Rendezvous Asteroid Flyby (CRAF) spacecraft, to be launched in 1991, was designed to study the physical and chemical properties of cometary and asteroid bodies. It is proposed that these properties can be determined by utilizing a penetrator experiment delivery system aboard the CRAF, which would deliver a passive gamma ray spectrometer to the comet and determine the composition of subsurface materials. Results of calculations for a model comet (50 percent CI carbonaceous chrondrite, 50 percent ices) provide data on the expected gamma ray fluxes, the minimum detectable limits, and the detection uncertainties for 35 isotopes. These results confirm that this technique can determine the composition of both the rocky and ice components, and the rock-to-ice ratio in the nucleus. In addition, useful information regarding the formation of the solar system is provided.

Evans, L. G.↗

VLBI observations of 416 extragalactic radio sources

The Deep Space Network is establishing a high-accuracy Very Long Base Interferometry (VLBI) celestial reference frame. Presented are the VLBI results of observations of 416 radio sources with declination north of -45 degrees which were conducted at frequencies of 2.3 GHz and 8.4 GHz. At 2.3 GHz 323 of 391 radio sources observed were detected with a fringe spacing of 3 milliarcsec and a detection limit of approximately 0.1 Jy. At 8.4 GHz, 278 of 416 radio sources were detected with a fringe spacing of 1 milliarcsec and a detection limit of approximately 0.1 Jy. This survey was conducted primarily to determine the strength of compact components at 8.4 GHz for radio sources previously detected with VLBI at 2.3 GHz. Compact extragalactic radio sources with strong correlated flux densities at both frequencies are used to form a high-accuracy reference frame.

Morabito, D. D.↗

VLBI observations of 416 extragalactic radio sources

Very long baseline interferometry (VLBI) observations of 416 radio sources with declinations north of -45 deg have been conducted at frequencies of 2.3 and 8.4 GHz. At 2.3 GHz, 323 of 391 radio sources observed were detected with a fringe spacing of 3 milliarcsec and a detection limit of about 0.1 Jy. At 8.4 GHz, 278 of 416 radio sources were detected with a fringe spacing of 1 milliarcsec and a detection limit of about 0.1 Jy. This survey was conducted primarily to determine the strength of compact components at 8.4 GHz for radio sources previously detected with VLBI at 2.3 GHz. Compact extragalactic radio sources with strong correlated flux densities at both frequencies are used to form a high-accuracy reference frame.

Morabito, D. D.↗

A statistical analysis of gamma-ray bursts detected by the Konus Experiment on Venera 11 and 12

We discuss the advantages of using the V/V sub max method to test well-defined samples of gamma-ray bursts for the spatial uniformity of their parent population. We have applied the V/V sub max test to gamma ray bursts of duration longer than 1 second recorded by the Konus experiment aboard Venera 11 and 12. Based on a sample of 123 bursts, we find V/V sub max equals 0.46 plus or minus 0.03, consistent with a uniform distribution in space. We urge that experimenters give careful attention to the detection limit for each recorded gamma ray burst, and that quantitative data for burst properties and detection limits be published.

Schmidt, Maarten↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Toxicological Assessment of ISS Air Quality: April - May 2013

A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

Meyers, Valerie↗

Collection and analysis of NASA clean room air samples

The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

Sheldon, L. S.↗

Monitoring Trace Contaminants in Air Via Ion Trap Mass Spectrometry

Recent passage of the Clean Air Act with its stricter regulation of toxic gas emissions, and the ever-growing number of applications which require faster turnaround times between sampling and analysis are two major factors which are helping to drive the development of new instrument technologies for in-situ, on-line, real-time monitoring. The ion trap, with its small size, excellent sensitivity, and tandem mass spectrometry capability is a rapidly evolving technology which is well-suited for these applications. In this paper, we describe the use of a commercial ion trap instrument for monitoring trace levels of chlorofluorocarbons (CFCs) and volatile organic compounds (VOCs) in air. A number of sample introduction devices including a direct transfer line interface, short column GC, and a cryotrapping interface are employed to achieve increasing levels of sensitivity. MS, MS/MS, and MS/MS/MS methods are compared to illustrate trade-offs between sensitivity and selectivity. Filtered Noise Field (FNF) technology is found to be an excellent means for achieving lower detection limits through selective storage of the ion(s) of interest during ionization. Figures of merit including typical sample sizes, detection limits, and response times are provided. The results indicate the potential of these techniques for atmospheric assessments, the High Speed Research Program, and advanced life support monitoring applications for NASA.

Palmer, Peter T.↗

Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds mentioned above can be separated on a GC column and detected by MS at sub-picomole (< 10(exp -l2 mole) levels. With these methods, the detection limit for amino acids, carboxylic acids and nucleobases is several orders of magnitude more sensitive than the Viking GCMS instruments for these compounds. Preliminary results using this analytical technique on a variety of Martian soil analogues will be presented.

Glavin, D. P.↗

Near Infrared Cavity Ring-Down Spectroscopy for Isotopic Analyses of CH4 on Future Martian Surface Missions

A compact Near Infrared Continuous Wave Cavity Ring-Down Spectrometer (near-IR-cw-CRDS) was developed as a candidate for future planetary surface missions. The optical cavity was made of titanium with rugged quartz windows to protect the delicate super cavity from the harsh environmental changes that it would experience during space flight and a Martian surface mission. This design assured the long-term stability of the system. The system applied three distributed feedback laser diodes (DFB-LD), two of which were tuned to the absorption line peaks of (sup 12)CH4 and (sup 13)CH4 at 6046.954 inverse centimeters and 6049.121 inverse centimeters, respectively. The third laser was tuned to a spectral-lines-free region for measuring the baseline cavity loss. The multiple laser design compensated for typical baseline drift of a CRDS system and, thus, improved the overall precision. A semiconductor optical amplifier (SOA) was used instead of an Acousto-Optic Module (AOM) to initiate the cavity ring-down events. It maintained high acquisition rates such as AOM, but consumed less power. High data acquisition rates combined with improved long-term stability yielded precise isotopic measurements in this near-IR region even though the strongest CH4 absorption line in this region is 140 times weaker than that of the strongest mid-IR absorption band. The current system has a detection limit of 1.4 times 10( sup –12) inverse centimeters for (sup 13)CH4. This limit corresponds to approximately 7 parts per trillion volume of CH4 at 100 Torrs. With no further improvements the detection limit of our current near IR-cw-CRDS at an ambient Martian pressure of approximately 6 Torrs (8 millibars) would be 0.25 parts per billion volume for one 3.3 minute long analysis.

portable nir crds↗

Addressing the Limit of Detectability of Residual Oxide Discontinuities in Friction Stir Butt Welds of Aluminum using Phased Array Ultrasound

This activity seeks to estimate a theoretical upper bound of detectability for a layer of oxide embedded in a friction stir weld in aluminum. The oxide is theoretically modeled as an ideal planar layer of aluminum oxide, oriented normal to an interrogating ultrasound beam. Experimentally-measured grain scattering level is used to represent the practical noise floor. Echoes from naturally-occurring oxides will necessarily fall below this theoretical limit, and must be above the measurement noise to be potentially detectable.

Johnston, P. H.↗

HST images of nearby luminous quasars

Strong upper limits are placed on the visual-band brightness of galactic hosts for four luminous, radioquiet quasars with redshifts between 0.16 and 0.24 that were studied with the Hubble Space Telescope (HST's) Wide Field/Planetary Camera 2 (WFPC2). Typical upper limits on the luminosities of galactic hosts are approximately 1.4 mag fainter than L* for spirals and approximately 0.5 mag fainter than L* for ellipticals. The galactic hosts of the quasars are more than a magnitude and a half fainter than the median integrated absolute magnitude of Seyfert galaxies. If the detection limits are determined using featureless simulated galaxies instead of observed galaxy images, then the detection limits for spirals are 0.5-1.0 mag less stringent. These results are consistent with the hypothesis that the quasar phenomenon corresponds to the early stages of galaxy formation, before extensive star formation occurs.

Bahcall, John N.↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

Rationally designed fluorescently labeled sulfate-binding protein mutants: evaluation in the development of a sensing system for sulfate

Periplasmic binding proteins from E. coli undergo large conformational changes upon binding their respective ligands. By attaching a fluorescent probe at rationally selected unique sites on the protein, these conformational changes in the protein can be monitored by measuring the changes in fluorescence intensity of the probe which allow the development of reagentless sensing systems for their corresponding ligands. In this work, we evaluated several sites on bacterial periplasmic sulfate-binding protein (SBP) for attachment of a fluorescent probe and rationally designed a reagentless sensing system for sulfate. Eight different mutants of SBP were prepared by employing the polymerase chain reaction (PCR) to introduce a unique cysteine residue at a specific location on the protein. The sites Gly55, Ser90, Ser129, Ala140, Leu145, Ser171, Val181, and Gly186 were chosen for mutagenesis by studying the three-dimensional X-ray crystal structure of SBP. An environment-sensitive fluorescent probe (MDCC) was then attached site-specifically to the protein through the sulfhydryl group of the unique cysteine residue introduced. Each fluorescent probe-conjugated SBP mutant was characterized in terms of its fluorescence properties and Ser171 was determined to be the best site for the attachment of the fluorescent probe that would allow for the development of a reagentless sensing system for sulfate. Three different environment-sensitive fluorescent probes (1,5-IAEDANS, MDCC, and acylodan) were studied with the SBP171 mutant protein. A calibration curve for sulfate was constructed using the labeled protein and relating the change in the fluorescence intensity with the amount of sulfate present in the sample. The detection limit for sulfate was found to be in the submicromolar range using this system. The selectivity of the sensing system was demonstrated by evaluating its response to other anions. A fast and selective sensing system with detection limits for sulfate in the submicromolar range was developed. Copyright 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 78: 517-526, 2002.

Evaluation Studies↗

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo↗

The Swift/BAT Hard X-Ray Survey

The BAT instrument on Swift is a wide field (70 deg. '100 deg.) coded aperture instrument with a CdZnTe detector array sensitive to energies of 14-200 keV. Each day, the BAT survey typically covers 60% of the sky to a detection limit of 30 millicrab. BAT makes hard X-ray light curves of similar sensitivity and coverage to the X-ray light curves from XTE/ASM, but in an energy range where sources show remarkably different behavior. Integrating the BAT data produces an all sky map with a source detection limit at 15 months of a few 10(exp -11) ergs per square centimeter per second, depending on the exposure. This is the first uniform all-sky survey at energies high enough to be unaffected by absorption since HEAO 1 in 1977-8. BAT has detected greater than 200 AGN and greater than 180 galactic sources. At high galactic latitudes, the BAT sources are usually easy to identify, but many are heavily absorbed and there are a few quite surprising identifications. The BAT selected galaxies can be used to calculate LogN/LogS and the luminosity function for AGN which are complete and free from common systematics. Several crucial parameters for understanding the cosmic hard x-ray background are now determined.

Tueller, Jack↗

Tropospheric nitric oxide measurements

Nitric oxide (NO) plays a key role in tropospheric photo-chemistry. The photochemical oxidation of hydrocarbons, for example, can serve as either a source or a sink for ozone, depending on the local abundance of NO. Nitric oxide also helps govern atmospheric concentrations of the hydroxyl (OH) radical. The OH radical is the single most important player in photochemical transformations because it controls the atmospheric lifetimes of so many chemical species. Although NO serves as a very effective catalyst in many important chemical processes, its concentration is low enough to normally be expressed in units of parts per trillion by volume (pptv). Consequently, commercially available detectors for NO (with detection limits of about one part per billion) have proven to be unsuitable for use anywhere except in urban areas and near other local pollution sources. Under the sponsorship of NASA's Global Tropospheric Experiment (GTE), Wallops has developed an extremely sensitive detector with a detection limit of a few pptv. The system was specifically designed for aircraft use, with the objective of applying it in global aircraft studies of tropospheric chemistry. Studies with the detector are examined.

Torres, A. L.↗

A Portable Universal Hazardous Gas Detector

Experimental work on the Miniature Mass Spectrometer (MMS) at JPL has resulted in a 'table top' configuration with a CCD detector that has demonstrated a detection limit of 50 parts per billion. The CCD detector operates at ambient temperature. Intelligent Ion, Inc., a commercial instrument developer, has taken out a license on the JPL technology and has built a prototype using a Faraday Cup Array detector as a placeholder detector. The prototype instrument was tested at Kennedy Space Center and demonstrated detection limits in the parts per million range. The test results are presented as well as detailed photographs of the prototype instrument. A presentation of the MMS was made to an expert review panel for 'On-Board Environmental Monitoring Systems for the International Space Station (ISS).' The scores obtained by the MMS system are presented. The prototype instrument will be retro fitted with a CCD array detector in August 2004 and will again be tested at KSC. The instrument is expected to show a detection level for hydrazines of 10 ppb and a detection level for solvents below 10 ppb.The expectations are based on raw data from the first batch of CCD's that was tested.

spacecraft fuels↗