Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Stream Chemistry, Synoptic Surveys, East Fork Poplar Creek Watershed, TN, USA; April 2023 to February 2025

Impacts of developed land cover on stream chemistry can be difficult to discern from natural variability, particularly in carbonate watersheds where weathering of urban infrastructure and lithology generate similar signatures. We evaluated how spatial patterns of stream chemistry varied across perennial and non-perennial tributaries spanning an urban-to-forested gradient in a mid-order, carbonate-dominated watershed. This data package contains a processed and compiled summary of stream chemistry and properties obtained from 12 synoptic surveys of 54 stream sites across the East Fork Poplar Creek watershed located near Oak Ridge, TN, United States. The sites include non-perennial tributaries, perennial tributaries, and the main stem and span forested to urban (highly developed) land cover gradients. The data package includes the processed and flagged chemical data (WaDE_SynopticSummary_FinalChemistry), metadata describing data flagging and analysis (WaDE_SynopticSummary_Metadata), information about each site and its contributing subcatchment (WaDE_SynopticSummary_SiteInformation), and a comparison of instrument and field detection limits used to determine method detection limits for the study (WaDE_SynopticSummary_DetectionLimitComparison). Stream chemistry includes stream parameters measured in situ using multiparameter probes (dissolved oxygen, pH, specific conductance, temperature) and solutes including nutrients (nitrate, ammonium, soluble reactive phosphorus), dissolved organic carbon, dissolved inorganic carbon, major cations (calcium, magnesium, potassium, sodium), major anions (chloride, sulfate), and a broad suite of minor and trace elements.

EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > SURFACE ↗

2016 Floodplain Geochemistry from the East River Watershed, Colorado

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Floodplain piezometers installed in several meanders (Meander C, Meander D, and Meander O) in the vicinity of the Pumphouse were sampled at several dates in 2016. Data includes in-field measurements (pH, electrical conductivity, oxidation reduction potential, dissolved oxygen, dissolved Fe(II), dissolved sulfide, and groundwater level) along with laboratory measurements (dissolved inorganic carbon, dissolved organic carbon, metals and major cations). Five files are included in this dataset, including: sample locations and depths in a csv file (metadata.csv), aqueous geochemistry data in a csv file, analytical detection limits in a csv file, a file-level metadata (flmd.csv) file, and a data dictionary (dd.csv) file. Data that was below the detection limit is reported as one half of the detection limit and missing data is listed as "-9999".

54 ENVIRONMENTAL SCIENCES↗

BEBOP II: sensitivity to sub-Saturn circumbinary planets using radial-velocities

ABSTRACT BEBOP is a radial-velocity survey that monitors a sample of single-lined eclipsing binaries, in search of circumbinary planets by using high-resolution spectrographs. Here, we describe and test the methods we use to identify planetary signals within the BEBOP data and establish how we quantify our sensitivity to circumbinary planets by producing detection limits. This process is made easier and more robust by using a diffusive nested sampler. In the process of testing our methods, we notice that contrary to popular wisdom, assuming circular orbits in calculating detection limits for a radial-velocity survey provides overoptimistic detection limits by up to $40{{\ \rm per\ cent}}$ in semi-amplitude with implications for all radial-velocity surveys. We perform example analyses using three BEBOP targets from our Southern HARPS survey. We demonstrate for the first time a repeated ability to reach a residual root mean squared scatter of $3\, \rm m\, s^{-1}$ (after removing the binary signal), and find that we are sensitive to circumbinary planets with masses down to that of Neptune and Saturn, for orbital periods up to $1000\, \rm d$.

Standing, Matthew R. (ORCID:0000000276088905)↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Quantum-enhanced detection of viral cDNA via luminescence resonance energy transfer using upconversion and gold nanoparticles

Abstract The COVID-19 pandemic has profoundly impacted global economies and healthcare systems, revealing critical vulnerabilities in both. In response, our study introduces a sensitive and highly specific detection method for cDNA, leveraging Luminescence Resonance Energy Transfer (LRET) between upconversion nanoparticles (UCNPs) and gold nanoparticles (AuNPs), and achieves a detection limit of 242 fM for SARS-CoV-2 cDNA. This innovative sensing platform utilizes UCNPs conjugated with one primer and AuNPs with another, targeting the 5′ and 3′ ends of the SARS-CoV-2 cDNA, respectively, enabling precise differentiation of mismatched cDNA sequences and significantly improving detection specificity. Through rigorous experimental analysis, we established a quenching efficiency range from 10.4 % to 73.6 %, with an optimal midpoint of 42 %, thereby demonstrating the superior sensitivity of our method. Our work uses SARS-CoV-2 cDNA as a model system to demonstrate the potential of our LRET-based detection method. This proof-of-concept study highlights the adaptability of our platform for future diagnostic applications. Instrumental validation confirms the synthesis and formation of AuNPs, addressing the need for experimental verification of the preparation of nanomaterial. Our comparative analysis with existing SARS-CoV-2 detection methods revealed that our approach provides a low detection limit and high specificity for target cDNA sequences, underscoring its potential for targeted COVID-19 diagnostics. This study demonstrates the superior sensitivity and adaptability of using UCNPs and AuNPs for cDNA detection, offering significant advances in rapid, accessible diagnostic technologies. Our method, characterized by its low detection limit and high precision, represents a critical step forward in developing next-generation biosensors for managing current and future viral outbreaks. By adjusting primer sequences, this platform can be tailored to detect other pathogens, contributing to the enhancement of global healthcare responsiveness and infectious disease control.

Esmaeili, Shahriar [Institute for Quantum Science ↗

Search for Postinflationary QCD Axions with a Quantum-Limited Tunable Microwave Receiver

A search for cosmological axions has been performed by scanning a frequency region of 38 MHz centered at about 10.2 GHz, corresponding to an axion mass 𝑚 𝑎 ≃ 42 μ ⁢eV. The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an 8 T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the 10 −14 GeV −1 level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred postinflationary region 𝑚 𝑎 > 40 μ ⁢eV.

Sardo Infirri, Giosue [INFN, Sezione di Padova; Un↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

Feasibility Study of Spectrophotometry to Support a Promethium Production Program at ORNL

Optical spectroscopy can be used to optimize analytical measurements for lanthanide elements and provide real-time feedback to help guide production operations. This study evaluates spectrophotometry for the determination of samarium (Sm 3+ ) and neodymium (Nd 3+ ) in aqueous and organic solutions at concentrations relevant to a promethium (Pm) program separation scheme. Detection limits approached 0.5 mM for Nd 3+ and 2 mM for Sm 3+ using Ocean Insight spectrophotometers. Additionally, Sm 3+ detection limits using laser fluorescence spectra for Sm 3+ approached single ppm (mg∙L -1 ) levels. An absorption spectrum containing Nd and Pm is also reported and discussed. This work demonstrates proofof-principle concepts for applying spectrophotometry to online monitoring applications in support of a future Pm production program.

47 OTHER INSTRUMENTATION↗

An 860 MHz Wireless Surface Acoustic Wave Sensor with a Metal-Organic Framework Sensing Layer for CO2 and CH4

Wireless and passive surface acoustic wave (SAW) devices with nanoporous metal-organic framework (MOF) sensing layers are attractive gas sensors for applications in many fields such as energy industries and air pollution control. Here, we report on enhancing the sensitivity and detection limit of zeolitic imidazolate framework-8 (ZIF-8) MOF-coated SAW reflective delay line mass sensors by increasing the operating frequency for sensitive detection of carbon dioxide (CO2) and methane (CH4) at ambient conditions. In particular, we show at least four times higher sensitivity of an 860 MHz (4-μm periodicity) SAW reflective delay line coated with a 240 nm thick ZIF-8 compared to the sensitivity of a 430 MHz (8-μm periodicity) otherwise identical sensor device to the targeted gases. The detection limits of the higher frequency wireless devices for CO2 and CH4 were estimated to be 0.91 vol-% and 7.01 vol-%, respectively. The enhanced sensitivity for higher frequency devices is explained in terms of the frequency dependent acoustic wave energy confinement.

Devkota, Jagannath↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Dissolved Inorganic Carbon and Dissolved Organic Carbon Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for dissolved organic carbon (DOC) and dissolved inorganic carbon (DIC) for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. DOC and DIC concentrations in water samples were determined using a TOC-VCPH analyzer (Shimadzu Corporation, Japan). DOC was analyzed as non-purgeable organic carbon (NPOC) by purging HCl-acidified samples with carbon-free air to remove DIC prior to measurement. After the acidified sample has been sparged, it is injected into a combustion tube filled with oxidation catalyst heated to 680 oC. The DOC in samples is combusted to CO2 and measured by a non-dispersive infrared (NDIR) detector. The peak area of the analog signal produced by the NDIR detector is proportional to the DOC concentration of the sample. DIC was determined by acidifying the samples with HCl first, and then purging with carbon-free air to release CO2 for analysis by NDIR detector. Total dissolved nitrogen (TDN) was analyzed using a Shimadzu Total Nitrogen Module (TNM-L) combined with the TOC-L analyzer (Shimadzu Corporation, Japan). TNM-L is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. All data reported are the mean values upon minimum of three replicate measurements, with a relative standard deviation < 3%. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (dic_npoc_data_2014-2025.zip) containing a total of 337 files: 336 data files of DIC and NPOC data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20250901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20250901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; and (4) PDF and docx files for the determiniation of Method Detection Limits (MDLs) for DIC and NPOC data, which has been updated in 2026-08. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing DIC/NPOC data. Update on 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update on 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses document, which can be accessed as a PDF or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated dissolved inorganic carbon and dissolved organic carbon data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-11-21. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for DIC and NPOC were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for DIC and NPOC data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Size-Selectively Biomolecule-Immobilized Nanoprobe-Based Chemiluminescent Lateral Flow Immunoassay for Detection of Avian-Origin Viruses

Here, a signal-amplifiable nanoprobe-based chemiluminescent lateral flow immunoassay (CL-LFA) was developed to detect avian influenza viruses (AIV) and other contagious and fatal viral avian-origin diseases worldwide. Signal-amplifiable nanoprobes are capable of size-selective immobilization of antibodies (binding receptors) and enzymes (signal transducers) on sensitive paper-based sensor platforms. Particle structure designs and conjugation pathways conducive for antigen accessibility to maximum amounts of immobilized enzymes and antibodies have advanced. The detection limit of the CL-LFA using the signal-amplifiable nanoprobe for the nucleoprotein of the H3N2 virus was 5 pM. Sensitivity tests for low pathogenicity avian influenza H9N2, H1N1, and high pathogenicity avian influenza H5N9 viruses were conducted, and the detection limits of CL-LFA were found to be 10 3.5 50% egg infective dose (EID 50 )/mL, 10 2.5 EID 50 /mL, and 10 4 EID 50 /mL, respectively, which is 20 to 100 times lower than that of a commercial AIV rapid test kit. Moreover, CL-LFA demonstrated high sensitivity and specificity against 37 clinical samples. The signal-amplifiable probe designed in this study is a potential diagnostic probe with ultrahigh sensitivity for applications in the field of clinical diagnosis, which requires sensitive antigen detection as evidenced by enhanced signaling capacity and sensitivity of the LFAs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors

High-sensitivity organic photodetectors (OPDs) with strong near-infrared (NIR) photoresponse have attracted enormous attention due to potential applications in emerging technologies. However, few organic semiconductors have been reported with photoelectric response beyond ~1.1 μm, the detection limit of silicon detectors. Here, we extend the absorption of organic small-molecule semiconductors to below silicon bandgap, and even to 0.77 eV, through introducing the newly designed quinoid-terminals with high Mulliken-electronegativity (5.62 eV). The fabricated photodiode-type NIR OPDs exhibit detectivity (D*) over 10 12 Jones in 0.41 to 1.2 μm under zero bias with a maximum of 2.9 × 10 12 Jones at 1.02 μm, which is the highest D* for reported OPDs in photovoltaic-mode with response spectra beyond 1.1 μm. The high D* in 0.9 to 1.2 μm is comparable to those of commercial InGaAs photodetectors, despite the detection limit of our OPDs is shorter than InGaAs (~1.7 μm). A spectrometer prototype with a wide measurable region (0.4 to 1.25 μm) and NIR imaging under 1.2-μm illumination are demonstrated successfully in OPDs.

36 MATERIALS SCIENCE↗