Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

WE-DE-BRA-03: Construction of An Ultrasound Guidance Platform for Image-Guided Radiotherapy with the Intent to Treat Transitional Cell Carcinoma

Purpose: Ultrasound (US) is a noninvasive, nonradiographic imaging technique with high spatial and temporal resolution that can be used for localizing soft-tissue structures and tumors in real-time during radiotherapy (inter- and intra-fraction). A detailed methodology integrating 3D-US within RT is presented. This method is easier to adopt into current treatment protocol than current US based systems and reduces user variability for image acquisition, thus eliminating transducer induced changes that limit CT planning system. Methods: We designed an in-house integrated US manipulator and platform to relate CT, 3D-US and linear accelerator coordinate systems. To validate the platform, an agar-based phantom with measured densities and speed-of-sound consistent with tissues surrounding the bladder, was rotated (0–45°) resulting in translations (up to 55mm) relative to the CT and US coordinate systems. After acquiring and integrating CT and US images into the treatment planning system, US-to-US and US-to-CT images were co-registered to re-align the phantom relative to the linear accelerator. Errors in the transformation matrix components were calculate to determine precision of this method under different patient positions. Results: Statistical errors from US-US registrations for different patient orientations ranged from 0.06–1.66mm for x, y, and z translational components, and 0.00–1.05° for rotational components. Statistical errors from US-CT registrations were 0.23–1.18mm for the x, y and z translational components, and 0.08–2.52° for the rotational components. Conclusion: Based on our result, this is consistent with currently used techniques for positioning prostate patients if couch re-positioning is less than a 5 degree rotation. We are now testing this on a dog patient to obtain both inter and intra-fractional positional errors. Additional design considerations include the future use of ultrasound-based functionality (photoacoustics, radioacoustics, Doppler) to monitor blood flow and hypoxia and/or in-vivo dosimetry for applications in other therapeutic techniques, such as hyperthermia, anti-angiogenesis, and particle therapy.

60 APPLIED LIFE SCIENCES↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Machine Learning-Based Process Control for Injection Molding of Recycled Polypropylene

The increased interest in artificial intelligence in manufacturing has driven the adoption of machine learning to optimize processes and improve efficiency. A key challenge in injection molding is the variability of recycled materials, which affects part quality and processing stability. This study presents a novel closed-loop process control approach for injection molding, leveraging machine learning to adaptively predict processing inputs and quality outcomes. The methodology was tested on five blends of recycled polypropylene (rPP), using artificial neural networks (ANNs), linear regression, and polynomial regression to model the relationships between material properties and process parameters. The dataset was split 80/20 into training and testing sets. The ANN model was implemented using TensorFlow and Keras, with six hidden layers of 32 neurons per layer, ReLU activation, and an Adam optimizer. Empirical tuning and early stopping were used to optimize performance and prevent overfitting. Predictions were evaluated based on mean absolute error (MAE), mean squared error (MSE), and percentage error. The results showed that yield stress, ultimate elongation, and part weight were accurately predicted within a 5% error for linear and polynomial regression models and within a 10% error for the ANN. However, modulus predictions were less reliable, with errors of ~11% for ANN and linear regression and ~40% for polynomial regression, reflecting the inherent variability of this property in rPP blends. Predictions of processing inputs had errors ranging from 3% to 25%, depending on the model and response variable. No single modeling approach was consistently superior across all responses, highlighting the complexity of the relationship between material properties, process parameters, and quality metrics. Overall, the work demonstrates that closed-loop process control, powered by machine learning, can effectively predict key quality parameters in injection molding of recycled materials. The proposed approach can improve process stability and material utilization, facilitating increased adoption of sustainable materials.

Krantz, Joshua↗

A variational framework for residual-based adaptivity in neural PDE solvers and operator learning

Residual-based adaptive strategies are widely used in scientific machine learning yet remain largely heuristic. We introduce a variational framework that formalizes these methods through convex transformations of the residual, where different transformations correspond to distinct objective functionals. For instance, exponential weights target uniform error minimization, while linear weights recover quadratic error minimization. This perspective reveals adaptive weighting as a means of selecting sampling distributions that optimize a primal objective, directly linking discretization choices to error metrics. This principled approach yields three key benefits: it enables systematic design of adaptive schemes, reduces discretization error by lowering estimator variance, and enhances learning dynamics by improving gradient signal-to-noise ratio. Extending the framework to operator learning, we demonstrate substantial performance gains across diverse optimizers and architectures. Our results provide a theoretical perspective for residual-based adaptivity and establish a foundation for principled discretization and training.

97 MATHEMATICS AND COMPUTING↗

SU-G-TeP4-08: Automating the Verification of Patient Treatment Parameters

Purpose: To automate the daily verification of each patient’s treatment by utilizing the trajectory log files (TLs) written by the Varian TrueBeam linear accelerator while reducing the number of false positives including jaw and gantry positioning errors, that are displayed in the Treatment History tab of Varian’s Chart QA module. Methods: Small deviations in treatment parameters are difficult to detect in weekly chart checks, but may be significant in reducing delivery errors, and would be critical if detected daily. Software was developed in house to read TLs. Multiple functions were implemented within the software that allow it to operate via a GUI to analyze TLs, or as a script to run on a regular basis. In order to determine tolerance levels for the scripted analysis, 15,241 TLs from seven TrueBeams were analyzed. The maximum error of each axis for each TL was written to a CSV file and statistically analyzed to determine the tolerance for each axis accessible in the TLs to flag for manual review. The software/scripts developed were tested by varying the tolerance values to ensure veracity. After tolerances were determined, multiple weeks of manual chart checks were performed simultaneously with the automated analysis to ensure validity. Results: The tolerance values for the major axis were determined to be, 0.025 degrees for the collimator, 1.0 degree for the gantry, 0.002cm for the y-jaws, 0.01cm for the x-jaws, and 0.5MU for the MU. The automated verification of treatment parameters has been in clinical use for 4 months. During that time, no errors in machine delivery of the patient treatments were found. Conclusion: The process detailed here is a viable and effective alternative to manually checking treatment parameters during weekly chart checks.

60 APPLIED LIFE SCIENCES↗

Minimum entropy filtering for a single output non-Gaussian stochastic system using state transformation

This paper presents a novel filter design for the single-output stochastic non-linear systems subjected to non-Gaussian noises and the proposed assumptions. Based on a state transformation, the unmeasurable states of the systems can be estimated where non-linear terms in the systems have been eliminated. It has been shown that the estimation error is linearly dynamical regarding to the presented vector-valued filter gain which can be optimised by minimising the entropy-based performance criterion. In addition, the convergence of the presented algorithm is analysed in mean-square sense and a numerical example is given to verify the effectiveness of the presented filtering algorithm. Meanwhile, the extended Kalman filter, unscented particle filter and minimum entropy filter are given for the comparisons of the filtering performance. Following the presented framework, some extensions of the presented filtering algorithm are discussed to indicate the flexibility of the filter design. The contribution of this paper can be summarised as establishing a novel minimum entropy filtering framework which consists of model transformation, entropy optimisation and convergence analysis.

42 ENGINEERING↗

Estimation of Errors Associated With Use of Linear-Quadratic Formalism for Evaluation of Biologic Equivalence Between Single and Hypofractionated Radiation Doses: An In Vitro Study

Purpose: To investigate the reliability of the linear-quadratic (LQ) formalism and the magnitude of errors associated with its use in assessing biologic equivalence between single, high radiation doses and hypofractionated radiation doses. Methods and Materials: V79 and EMT6 single cells received single doses of 2-12 Gy or two or three fractions of 4 or 5 Gy, each at 4-h intervals. Single and fractionated doses to actually reduce the cell survival to the same level were determined by a colony assay. The {alpha}/{beta} ratio was obtained from the cell survival curves. Using the {alpha}/{beta} ratio and the LQ formalism, equivalent single doses for the hypofractionated doses were calculated. They were then compared with the actually determined equivalent single doses for the hypofractionated doses. The V79 spheroids received single doses of 5-26 Gy or two to five fractions of 5-12 Gy at 2 or 4-h interval, and then were assayed for cell survival. Next, equivalent single doses for the hypofractionated doses were determined, as were done for the single cells. Results: The {alpha}/{beta} ratio was 5.1 Gy for the V79 single cells and 0.36 Gy for EMT6. In V79, the equivalent single doses for the hypofractionated doses calculated using the LQ formalism were 12-19% lower than the actually measured biologically equivalent single doses. In the EMT6 cells, this trend was also seen, but the differences were not significant. In the V79 spheroids, the calculated doses were 18-30% lower than the measured doses. Conclusion: Conversion of hypofractionated radiation doses to single doses using the LQ formalism could underestimate the effect of hypofractionated radiation by {<=}30%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Error statistics and scalability of quantum error mitigation formulas

Quantum computing promises advantages over classical computing in many problems. Nevertheless, noise in quantum devices prevents most quantum algorithms from achieving the quantum advantage. Quantum error mitigation provides a variety of protocols to handle such noise using minimal qubit resources. While some of those protocols have been implemented in experiments for a few qubits, it remains unclear whether error mitigation will be effective in quantum circuits with tens to hundreds of qubits. In this paper, we apply statistics principles to quantum error mitigation and analyse the scaling behaviour of its intrinsic error. We find that the error increases linearly O(ϵN) with the gate number N before mitigation and sublinearly O(ϵ'N γ ) after mitigation, where γ ≈ 0.5, ϵ is the error rate of a quantum gate, and ϵ' is a protocol-dependent factor. The $\sqrt{N}$ scaling is a consequence of the law of large numbers, and it indicates that error mitigation can suppress the error by a larger factor in larger circuits. We propose the importance Clifford sampling as a key technique for error mitigation in large circuits to obtain this result.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-145: Geometric Uncertainty in CBCT Extrapolation for Head and Neck Adaptive Radiotherapy

Purpose: One primary limitation of using CBCT images for H'N adaptive radiotherapy (ART) is the limited field of view (FOV) range. We propose a method to extrapolate the CBCT by using a deformed planning CT for the dose of the day calculations. The aim was to estimate the geometric uncertainty of our extrapolation method. Methods: Ten H'N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken, were selected. Furthermore, a small FOV CBCT (CT2short) was synthetically created by cropping CT2 to the size of a CBCT image. Then, an extrapolated CBCT (CBCTextrp) was generated by deformably registering CT1 to CT2short and resampling with a wider FOV (42mm more from the CT2short borders), where CT1 is deformed through translation, rigid, affine, and b-spline transformations in order. The geometric error is measured as the distance map ||DVF|| produced by a deformable registration between CBCTextrp and CT2. Mean errors were calculated as a function of the distance away from the CBCT borders. The quality of all the registrations was visually verified. Results: Results were collected based on the average numbers from 10 patients. The extrapolation error increased linearly as a function of the distance (at a rate of 0.7mm per 1 cm) away from the CBCT borders in the S/I direction. The errors (μ±σ) at the superior and inferior boarders were 0.8 ± 0.5mm and 3.0 ± 1.5mm respectively, and increased to 2.7 ± 2.2mm and 5.9 ± 1.9mm at 4.2cm away. The mean error within CBCT borders was 1.16 ± 0.54mm . The overall errors within 4.2cm error expansion were 2.0 ± 1.2mm (sup) and 4.5 ± 1.6mm (inf). Conclusion: The overall error in inf direction is larger due to more large unpredictable deformations in the chest. The error introduced by extrapolation is plan dependent. The mean error in the expanded region can be large, and must be considered during implementation. This work is supported in part by Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

One-dimensional single-mode fiber-optic displacement sensors for submillimeter measurements

We demonstrate the working principle of a one-dimensional intensity-based fiber-optic displacement sensor. The sensor consists of one receiving fiber, which is moved laterally in the optical field emitted by an emitting fiber. It is shown numerically that the sensor response is highly linear (nonlinearity error of 0.1 to 2%) for a wide range of travel (2.24 to 860 {mu}m). The sensor response is also simulated experimentally using a highly precise robot, the results of which correspond very closely to numerical ones. Linearity, travel, and sensitivity are experimentally determined for different gaps between the emitting and the receiving fibers (10 {mu}m to 10 mm). A design chart that includes the nonlinearity error (0.5% to 2%), the travel (2.78 to 860 {mu}m), the sensitivity (0.032 to 0.37 dB/{mu}m), and the gap distance (1 to 10 mm) is finally proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Learning Quantum States and Unitaries of Bounded Gate Complexity

While quantum state tomography is notoriously hard, most states hold little interest to practically minded tomographers. Given that states and unitaries appearing in nature are of bounded gate complexity, it is natural to ask if efficient learning becomes possible. In this work, we prove that to learn a state generated by a quantum circuit with G two-qubit gates to a small trace distance, a sample complexity scaling linearly in G is necessary and sufficient. We also prove that the optimal query complexity to learn a unitary generated by G gates to a small average-case error scales linearly in G . While sample-efficient learning can be achieved, we show that under reasonable cryptographic conjectures, the computational complexity for learning states and unitaries of gate complexity G must scale exponentially in G . We illustrate how these results establish fundamental limitations on the expressivity of quantum machine-learning models and provide new perspectives on no-free-lunch theorems in unitary learning. Together, our results answer how the complexity of learning quantum states and unitaries relate to the complexity of creating these states and unitaries. Published by the American Physical Society 2024

Zhao, Haimeng (ORCID:0000000166751489)↗

Dosimetric Accuracy of a Dual Photon Energy Linac at Low Monitor Setting for Various Pulse Repetition Frequencies

Accuracy of dose delivery at low monitor unit setting is studied for a dual photon energy linear accelerator. Dose delivered per MU is found to be constant for both the photon beams for MU settings above 30. For lower MUs there is definite deviation from the calibrated value and the error is found to be increasing as fewer MUs are set for dose delivery. This dose/MU ratio at low MU setting is found to be dose-rate dependent, showing an increasing trend with pulse repetition frequency (PRF). Also, the dosimetric ratio is observed to be mode dependent; its value for an 18 MV beam is almost double that observed in the case of a 6 MV beam at very low MU setting. The magnitude of this error should be determined for each energy so that appropriate corrections can be applied if very low MUs are to be used.

61 RADIATION PROTECTION AND DOSIMETRY↗

Whitepaper prepared for DOE Workshop on Integrated Simulations for Magnetic Fusion Energy Sciences: Topic E: Beyond interpretive simulations

Predictive simulations of magnetic confinement fusion and burning plasmas will require the quantification of all uncertainties and errors relating to the simulation capabilities. These include: discretization error (temporal and spatial); incomplete convergence error (nonlinear, linear, etc.); uncertainties in input data (initial conditions, boundary conditions, coefficients, thermo-physical properties, source terms, etc.); and uncertainties in the component models (the specific form and parameter values).13 Typically, there is a focus on model parameter uncertainties but uncertainties about which model to use and about the bias or discrepancy of a particular model (sometimes called model form error) often dominate parameter uncertainty. This whitepaper addresses the challenges of performing uncertainty quantification (UQ) for expensive computational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ON THE TIMESCALE FOR STAR FORMATION IN GALAXIES

The timescale for star formation, a measure of how quickly neutral gas is being converted to stars, is considerably longer than typical dynamical timescales associated with a galactic disk. For purposes of modeling galaxy evolution, however, it would be extremely attractive if the star formation timescale was proportional to an easily derived dynamical timescale. We compare estimates of the star formation timescale within nearby galaxies, based on the work of Leroy et al. and existing BIMA Survey of Nearby Galaxies CO data, with three simple forms of the dynamical time: the orbital time; the free-fall time at the midplane density; and the disk Jeans time (the growth time for gravitational instabilities in a disk). When taking into account the gravity of the stellar disk in an approximate way, all three timescales show correlations with the star formation timescale, though none of the correlations can be accurately described as linear. Systematic errors in estimating appropriate gas masses and the stellar velocity dispersion may obscure an underlying correlation, but we focus instead on a model where the timescale for H{sub 2} formation from H I is decoupled from the timescale for star formation from H{sub 2}. The Jeans time correlates well with the first of these timescales, but the relationship is still non-linear and requires a characteristic giant molecular cloud lifetime that increases toward galaxy centers.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Methodology for Calculating The Energy Performance of Manufacturing Facilities

Total energy comparison (TEC), classic energy intensity (CEI), and linear regression models (LRM) are the three most common approaches used to track the energy performance of manufacturing facilities. TEC simply compares the total energy consumption from utility bills. TEC is rarely used because it does not consider the variation of any factors that may affect energy consumption. One step better, CEI considers the variation of production rates by using the ratio of annual total energy consumption over annual total production. However, CEI fundamentally assumes that energy consumption is zero if the production rate is zero. This is almost never true and can cause significant errors. Using linear regression models, LRM considers the impact of multiple variables and, therefore, most accurately tracks energy performance. Unfortunately, because of the lack of either required data or technical expertise, some facilities cannot create valid linear regression models. For these cases, CEI is the only option. Here, the goal of this article is to develop a new methodology, modified energy intensity (MEI), which is more accurate than CEI, but requires much less data and is easier to implement than LRM. Using the underlying principle of LRM, this article first outlines the mathematical derivation of the equations for MEI, then explains them from an engineering perspective. Finally, the implementation of MEI is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sci—Sat AM: Stereo — 09: Accuracy of Liver Cancer Treatment on Cyberknife® with Synchrony™ Optical Tracking Throughout the Respiratory Cycle

The Cyberknife® robotic stereotactic body radiation therapy system is well-suited for treating liver lesions over the respiratory cycle as it includes room-mounted orthogonal x-ray tracking of internal fiducial markers and optical tracking of external markers. The Synchrony™ software generates a model of internal target positions during patient respiration and correlates it to the external optical tracking system for real-time optical-based position corrections of the linear accelerator during beam delivery. Although clinical studies have provided preliminary outcomes for liver lesions treated with the Cyberknife system, to date, there is little data demonstrating the ability of the Synchrony software to track targets in the liver, which deforms throughout the respiratory cycle. In this study, we investigated the respiratory motion model performance for predicting tumour motion. We conducted a retrospective analysis of fifteen liver cancer patients treated on the Cyberknife using the Synchrony optical tracking system. We analyzed Cyberknife tracking information stored in the log files to extract the left-right (LR), anterior-posterior (AP) and superior-inferior (SI) correlation errors between the model-predicted position and the internal fiducial centroid position determined by x-ray imaging. Only translational tracking and corrections were applied during treatment. Overall, the correlation errors were greatest in the SI direction. We calculated radial correlation errors, and determined that the 95{sup th}, 98{sup th} and 99{sup th} percentile errors were 3.4 mm, 4.4 mm and 5.1 mm, respectively. Based on translational correlation tracking errors we expect the clinical target volume will be within 3.4 mm of the planning target volume for 95 % of beam delivery time.

60 APPLIED LIFE SCIENCES↗