Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Prospects for the expansion of standing wave ambient pressure photoemission spectroscopy to reactions at elevated temperatures

Standing wave ambient pressure photoemission spectroscopy (SWAPPS) is a promising method to investigate chemical and potential gradients across solid-vapor and solid-liquid interfaces under close-to-realistic environmental conditions, far away from high vacuum. Until now, these investigations have been performed only near room temperature, but for a wide range of interfacial processes, chief among them being heterogeneous catalysis, measurements at elevated temperatures are required. One concern in these investigations is the temperature stability of the multilayer mirrors, which generate the standing wave field. At elevated temperatures, degradation of the multilayer mirror due to, for example, interdiffusion between the adjacent layers, decreases the modulation of the standing wave field, thus rendering SWAPPS experiments much harder to perform. Here, we show that multilayer mirrors consisting of alternate B4C and W layers are stable at temperatures exceeding 600 °C and are, thus, promising candidates for future studies of surface and subsurface species in heterogeneous catalytic reactions using SWAPPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multistage nucleation pathway in LiF molten salt mirrors the crystal–melt interface structure

Despite over a century of studies, fundamental questions remain about the processes governing crystal nucleation from melts or solutions. Research over the past three decades has presented mounting evidence for kinetic pathways of crystal nucleation that are more complex than envisioned by the simplest forms of classical theory. Such observations have been presented for colloidal and elemental systems with covalent and metallic bonding. Despite the technological and geochemical importance of molten salts, similar studies for these ionically bonded systems are currently lacking. Here we develop a machine learning interatomic potential for a model ionic system: LiF. The potential features quantum-level accuracy for both liquid and multiple solid polymorphs over wide temperature and pressure ranges and accurately reproduces experimentally measured properties. Thanks to the efficiency of the potential, which enables microsecond-scale molecular dynamics simulations, induction times for nucleation of LiF solids from their melts are computed over a range of undercoolings. With the aid of a set of robust local order parameters established here, the simulations reveal that homogeneous crystal nucleation in undercooled melts preferentially initiates from liquid regions showing slow dynamics and high bond orientational order simultaneously, and the second-shell order of both precritical nuclei and the surface of postcritical nuclei is dominated by hexagonal close packing and body-centered cubic local structure, even though the nucleus core is dominated by face-centered cubic structure corresponding to the stable rocksalt crystal structure. Finally, we establish a connection between the crystallization pathway and the equilibrium crystal-melt interface structure.

Applied Physical Sciences↗

Identification of Prompt Proton Emission in $N = Z - 1$ 61 Ga: Isospin Symmetry at the Limit of Nuclear Binding

Excited states in the proton drip line nucleus 61 Ga were populated via the fusion-evaporation reaction 24 Mg ⁢( 40 Ca, 𝑝⁢2⁢𝑛)⁢ 61 Ga. The experimental setup at Argonne National Laboratory comprised a novel combination of the Gammasphere array with two CD-shaped double-sided Si-strip detectors inside the Microball CsI(Tl) charged-particle detection array, as well as the Neutron-Shell liquid scintillators and the Fragment Mass Analyzer. Owing to the setup’s unprecedented in-beam proton spectroscopy and tracking capabilities, a coincidence between a 957.6(5)-keV 𝛾 ray and a 1.876(24)-MeV proton line was observed, which identifies the quasibound proton 𝜋⁢𝑔 9/2 single-particle state in 61 Ga at 𝐸 𝑥 = 2150⁢(34) keV. This probes isospin symmetry at the limit of nuclear binding by providing a unique challenge for the shell-model interpretation of mirror nuclei beyond doubly magic 56 Ni .

Hrabar, Yuliia [Lund Univ. (Sweden)] (ORCID:000000↗

Optical transparency of LiF (100) shock compressed to ∼360 GPa

High-purity [100] lithium fluoride (LiF) is the most widely used optical window in dynamic compression experiments due to its wide bandgap and well-characterized mechanical response. Recent plate-impact experiments established the [100] LiF Hugoniot to ∼230 GPa and demonstrated shock-induced melting onset at 182 GPa with complete melting by 195 GPa; theoretical models predict LiF optical transparency to nearly 900 GPa. To experimentally examine the optical transparency of [100] LiF at higher pressures and in the liquid state, laser-driven shock experiments were performed at peak stresses ranging from 223 to 363 GPa. Optical response was examined by measuring the particle velocity histories at the Kapton/LiF interface using laser interferometry at 532 and 1550 nm wavelengths; in-material particle velocities were obtained using established refractive-index corrections. Continuous photonic Doppler velocimetry fringes were observed across the entire stress range, demonstrating that LiF remains transparent to 1550 nm light throughout the multi-megabar regime investigated. At 532 nm, fringe visibility depended on the reflector coating: aluminum mirrors provided signals to ∼235 GPa, while gold mirrors extended this limit to 270.5 GPa, indicating that the shorter-wavelength response is likely sensitive to experimental configuration rather than to the loss of LiF transparency. Continued optical transparency to at least 360 GPa indicates that shock-melted LiF does not display bandgap closure over the stress range explored. Furthermore, these results provide direct experimental constraints on the high-pressure optical response and establish LiF (100) as a robust optical window material for laser-driven dynamic compression experiments approaching 400 GPa.

Renganathan, P. [Argonne National Laboratory (ANL)↗

Strain Anisotropy Driven Spontaneous Formation of Nanoscrolls from 2D Janus Layers

2D Janus transition metal dichalcogenides (TMDs) have attracted attention due to their emergent properties arising from broken mirror symmetry and self‐driven polarization fields. While it has been proposed that their vdW superlattices hold the key to achieving superior properties in piezoelectricity and photovoltaic, available synthesis has ultimately limited their realization. Here, in this study, the first packed vdW nanoscrolls made from Janus TMDs through a simple one‐drop solution technique are reported. The results, including ab initio simulations, show that the Bohr radius difference between the top sulfur and the bottom selenium atoms within Janus ${M^S_{Se}}$ (M = Mo, W) results in a permanent compressive surface strain that acts as a nanoscroll formation catalyst after small liquid interaction. Unlike classical 2D layers, the surface strain in Janus TMDs can be engineered from compressive to tensile by placing larger Bohr radius atoms on top (${M_S^{Se}}$) to yield inverted C scrolls. Detailed microscopy studies offer the first insights into their morphology and readily formed Moiré lattices. In contrast, spectroscopy and FETs studies establish their excitonic and device properties and highlight significant differences compared to 2D flat Janus TMDs. These results introduce the first polar Janus TMD nanoscrolls and introduce inherent strain‐driven scrolling dynamics as a catalyst to create superlattices.

36 MATERIALS SCIENCE↗

System-Level Comparison of Sodium and Salt Systems in Support of the Gen3 Liquids Pathway

This paper presents the comparison of the annual performance and the Levelised Cost of Energy (LCOE) of two high- temperature solar power tower configurations using a 565MWth chloride salt receiver and a 540 MWth liquid sodium receiver. Each power tower consists of a sodium or salt receiver, a 175 m high concrete tower, and a two-tank chloride salt system for thermal energy storage (TES). The power plants were simulated using SolarTherm to estimate their energy per year, capacity factor, and LCOE. The simulation was verified against the System Advisor Model (SAM), showing that the LCOE calculation differences are within ±1.0%. Results showed that the sodium-receiver system yields 69.60 USD/MWh real LCOE, versus 78.55 USD/MWh for the chloride salt system. Results also showed that sodium wins here due to a smaller and more efficient receiver, enabled by higher flux limits and reduced field size, leading to less mirror reflective area and site improvement cost.

capacity factor↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of Small Particle Growth and Aging at the Atmospheric Radiation Measurement Southern Great Plains Observatory Field Campaign Report

Two identical Captive Aerosol Growth and Evolution (CAGE) chambers were operated at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in the late summer and fall of 2021. The field study was scheduled to begin in spring, 2020, but was delayed because of the pandemic. CAGE chambers are designed to expose particles to an environment that mirrors that of the surroundings with or without a controlled perturbation designed to assess a sensitivity. The analysis here focuses on roughly the last two months of the overall study period during which measurements were almost continuous and when several perturbation experiments were conducted. Though the utility of a dual-chamber system is the ability to measure the influence of a single change on top of ambient conditions, both chambers were initially operated in the same way, with ambient air pulled through the gas exchange channel in both and ammonium sulfate particles injected into both. The similar time-dependent particle growth observed in the chambers for those periods provides confidence in differences observed during the subsequent perturbation experiments. The growth rate of particles in the reference chamber into which only ammonium sulfate particles were injected and for which only ambient air was pulled through were used to describe time-of-day averages. The average growth rate was highest in the evening and in the morning after sunrise and lowest in the late afternoon. The sensitivity of particle growth to secondary aerosol precursor gases was studied by adding them at a controlled rate to the ambient air flow pulled through one of the two chambers. Addition of 5 ppb of α-pinene resulted in an average particle growth rate of 4.4 nm hr -1 , compared with that of just 0.8 nm hr -1 in the reference chamber. The added α-pinene also triggered one new particle formation (NPF) event in the early evening just before sunset and another in the morning just after sunrise. Similarly, addition of 5 ppb of SO 2 to one chamber led to a pair of NPF events and to increased particle growth rate, though unlike the impact of added α-pinene, growth was enhanced only during the daytime when OH concentration is highest. The influence of aerosol liquid water on secondary aerosol formation and particle growth was investigated by injecting ammonium sulfate seed particles into one chamber and potassium sulfate particles into the other. Particles were injected into the two chambers four times over a 1.5-day period. The chamber relative humidity (RH) history during and following each injection was used to determine whether each particle type was crystalline or aqueous. For the case when both particle types remained crystalline throughout the period, they were tracked and for the case when they remained aqueous, the magnitude and time-dependence of the growth of both were almost exactly the same. For the other two cases the ammonium sulfate particles deliquesced upon injection and remained aqueous, while the potassium sulfate particles remained crystalline. For those two cases, the aqueous particles grew substantially faster than did the crystalline particles, providing evidence of the role of aerosol liquid water on secondary aerosol formation and particle growth.

54 ENVIRONMENTAL SCIENCES↗

Molecular-Level Design of Heterogeneous Chiral Catalysts

A recent major focus of catalyst research has been on improving the selectivity or atom efficiency of catalytic processes. Perhaps the most subtle and difficult form of selectivity to control is enantioselectivity, a catalyst’s ability to preferentially yield one enantiomer of a chiral product. Since two enantiomers are identical in all respects except for their mirror reflection symmetry, both are formed in non-chiral environments at exactly equal rates; only by introducing some type of chiral modification to the system can the rate of formation of one enantiomer be favored over the other. This has been successfully achieved for homogeneous-phase, organometallic catalysts, but the empirical development of heterogeneous-phase analogs has proven elusive. The design of such heterogeneous-phase catalysts would obviate the need for inefficient purification steps to remove the heavy-metal catalysts. The goal of the proposed research by the Chiral Catalysis Group is to understand the interactions of prochiral reactants on chirally modified surfaces that lead to the preferential formation of one enantiomer over the other. There are two general concepts for designing heterogeneous-phase enantioselective catalysts. The first adopts the strategy used in homogeneous phase, by adding a chiral modifier to the surface. This approach, while conceptually simple has challenges associated with modifying an extended surface. The second concept, which is unique to extended surfaces, is the idea of creating surfaces that are themselves naturally chiral. A fundamental understanding of the interactions that control enantioselectivity will enable the Chiral Catalysis Group to develop the concepts necessary to design novel, heterogenous catalytic materials. Enantioselectivity is also central to catalytic processes that underpin the pharmaceutical and agrochemical industries. With funding from the Department of Energy, the Chiral Catalysis Group has played a leading role in developing a fundamental understanding of chiral catalysis and of the adsorbate structures, interactions and kinetic effects that control heterogenous-phase enantioselectivity. The proposed research program is organized conceptually around three types of enantiospecific interactions: interactions with naturally chiral surfaces; those with modified surfaces categorized as chirally templated surfaces; and one-to-one interactions of prochiral molecules with chiral surface modifiers. Our specific goals are to: (1) determine the structures of chiral surfaces, prochiral reactants, chiral products and chiral modifiers; (2) understand the enantiospecific interactions that occur between prochiral reactants and chiral products with chirally modified surfaces; (3) develop methods for detection of enantiospecific surface phenomena; and (4) elucidate enantioselective reaction pathways and the interactions that control them. The range of expertise within the Chiral Catalysis Group includes molecular-scale theory, surface science experiments, state-of-the-art spectroscopic, kinetic and atomic-scale imaging capabilities carried out in vacuum and under more-realistic liquid- and gas-phase environments complemented by catalytic measurements. By fully integrating such a breadth of approaches and extensive expertise, the Chiral Catalysis Group will, for the first time, be able to understand, rationally design and then control active sites for optimal enantioselectivity. In addition to having a significant impact on the field of chiral catalysis, the proposed research program will further our general understanding of the molecular-scale origins of catalytic selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗