Search NASA⌕ Search

SEARCH · Search NASA

Results for “List mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Measurement of the 235U Induced Fission Gamma-ray Spectrum as an Active Non-destructive Assay of Fresh Nucleear Fuel

Non-destructive assay is a powerful tool the International Atomic Energy Agency (IAEA) employs to verify adherence to safeguards agreements. Current IAEA veri- cation techniques for fresh nuclear fuel include passive gamma-ray spectroscopy to determine fuel enrichment. This technique suers from self-shielding and lakes the percision to detect diversion of central fuel rods. The aim of this research is to develop a new, more capable non-destructive analysis technique using active neutron interroga- tion of fuel assemblies and determining the yields of short-lived ssion products from high-resolution gamma-ray spectroscopy using high-purity germanium (HPGe). This paper reports results from irradiation of a one meter tall mock fresh fuel assembly with low enriched uranium (LEU) or depleted uranium (DU) rods using a down-scattered deuterium-tritium (D-T) neutron source. Both prompt and delayed gamma-ray spec- tra were collected as time-stamped list-mode data in a coax detector and without list mode data in a planar strip detector. No dierentiating signatures were observed in the prompt spectra in either detector; however, both detectors observed several short-lived ssion product signatures in LEU and not DU fuel, indicating that this technique has potential for determination of enrichment of fresh fuel assemblies. There were eight unique ssion products observed in the LEU spectra with the coax detector spectra, and three ssion products were observed in the LEU spectra with the strip detector.

Fission Gamma-ray Spectrum↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Pile-up recovery in gamma-ray detection

Count rates in gamma-ray detectors are fundamentally limited at the high end by the physics of the detection process but should not be limited further by the design of read-out. Using intense stimuli, such as the ELI, it is desirable to extract the full wealth of information flow that sensors can deliver. We discuss the photon-statistical limitations of scintillation systems and charge-collection issues of solid-state detectors. With high-speed digitizing in particular, two promising approach architectures are those of posterior list mode corrections and of time-domain adaptive filters, introducing a 'rich list mode with uncertainties' and thus a somewhat different look at experimental spectra. Real-time performance is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Criticality Eigenvalue Simulations for Subcritical Benchmark Evaluations

Subcritical multiplication experiments and simulations are important for a variety of applications including nonproliferation, safeguards, and criticality safety monitoring. Recently, subcritical experiments have been evaluated for inclusion in the International Criticality Safety Benchmark Evaluation Process (ICSBEP). In addition, new subcritical experiments have recently been designed. In these experiments, list-mode data (a list of each absorption in the neutron detector) is recorded and neutron noise analysis is used to determine the leakage multiplication (ML) of each configuration. One downside to the simulation of these types of experiments is that they are computationally expensive. This is because analog Monte Carlo with no variance reduction must be performed in order to maintain the time accuracy required in the measurement analysis. This work demonstrates that criticality eigenvalue simulations can be used to estimate sensitivities and uncertainties for three parameters: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), and leakage multiplication (M{sub L}). This will provide a useful aid both in the design and evaluation of new subcritical measurements. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating the non-ideal behavior of the Amptek A111 charge sensitive preamplifier & discriminator board— 3 He proportional counter combination used in common safeguards neutron coincidence counters

Neutron coincidence counting is a well-established technique used for the nondestructive quantification of specialnuclear material during international safeguards inspections. The neutron counters are commonly designedwith an annular body, centered about an inner well or cavity into which a measurement item is placed,and the moderating annulus is populated with 3 He tubes connected to a varying number of preamplifiers.The Canberra Industries JAB-01 preamplifier/amplifier/discriminator board is employed within the company’sneutron coincidence counters, built for use by the International Atomic Energy Agency. Non-ideal behavior ofthese boards was identified during a detector characterization, using list mode data acquisition, of a CanberraIndustries JCC-71 Neutron Coincidence Collar implementing four JAB-01 boards. List mode data acquisition andanalysis reveals features that have commonly been overlooked by historic timing gate selection while using shiftregister data acquisition methods, which are routinely adopted in international safeguards. It has been shownthat double pulsing effects are not fully captured within the predelay setting; therefore, they may influencethe response of the system within the standard operating regime. We set out to identify and correct for doublepulsing in our post analysis of neutron pulse trains, while isolating this behavior to the relevant system. Tounderstand and potentially address these concerns, the responses of two different JAB-01 board systems – theJCC-71 Neutron Coincidence Collar and a modified JCC-51 Active Well Neutron Coincidence Counter – arecompared with the responses of an AnTech Inc. N2071 Neutron Coincidence Collar that also uses an amplifierbuilt on the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip, and a JCC-71 that employs custompreamplifiers designed at Oak Ridge National Laboratory

42 ENGINEERING↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TListSpectrum

TListSpectrum is a C++ class developed inside the CERN high-energy physics analysis C++ framework ROOT. This class structure was developed to assist in the processing, visualization, and analysis of list-mode or time-stamped radiation spectroscopy data. The class structure currently contains parsing and functionality to synthesize list-mode data from CAEN and Mirion Lynx radiation spectroscopy digital acquisition systems along with feature functionality to post-process data sets and build coincident data sets from the instrument.

Pierson, Bruce↗

Utilization of the Differential Die-Away Self-Interrogation Technique for Characterization and Verification of Spent Nuclear Fuel

New nondestructive assay techniques are sought to better characterize spent nuclear fuel. One of the NDA instruments selected for possible deployment is differential die-away self-interrogation (DDSI). The proposed DDSI approach for spent fuel assembly assay utilizes primarily the spontaneous fission and (α, n) neutrons in the assemblies as an internal interrogating radiation source. The neutrons released in spontaneous fission or (α,n) reactions are thermalized in the surrounding water and induce fission in fissile isotopes, thereby creating a measurable signal from isotopes of interest that would be otherwise difficult to measure. The DDSI instrument employs neutron coincidence counting with 3He tubes and list-mode-based data acquisition to allow for production of Rossi-alpha distributions (RADs) in post-processing. The list-mode approach to data collection and subsequent construction of RADs has expanded the analytical possibilities, as will be demonstrated throughout this thesis. One of the primary advantages is that the measured signal in the form of a RAD can be analyzed in its entirety including determination of die-away times in different time domains. This capability led to the development of the early die-away method, a novel leakage multiplication determination method which is tested throughout the thesis on different sources in simulation space and fresh fuel experiments. The early die-away method is a robust, accurate, improved method of determining multiplication without the need for knowledge of the (α,n) source term. The DDSI technique and instrument are presented along with the many novel capabilities enabled by and discovered through RAD analysis. Among the new capabilities presented are the early die-away method, total plutonium content determination, and highly sensitive missing pin detection. Simulation of hundreds of different spent and fresh fuel assemblies were used to develop the analysis algorithms and the techniques were tested on a variety of spontaneous fission-driven fresh fuel assemblies at Los Alamos National Laboratory and the BeRP ball at the Nevada National Security Site. The development of the new, improved analysis and characterization methods with the DDSI instrument makes it a viable technique for implementation in a facility to meet material control and safeguards needs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Data Acquisition Development

This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muon tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the NPOD3 Detectors in MCNP5 and MCNP6

Researchers performed a series of measurements in May 2012 to characterize the NPOD3 detector systems. The detectors were placed in varying states of disassembly to determine the effect of individual components on detection efficiency. A 4.5 kg α-phase Pu sphere known as the Los Alamos BeRP Ball was used as the SNM source in both a bare configuration and reflected by varying thicknesses of polyethylene. A set of simulations matching the experimental setups were run and the data were compared to the measured data. The total and leakage multiplication and the inferred k values were determined for both the simulations and the measurements. Table 3 shows a comparison of the results from MCNP6 and MCNP5 with the list-mode patch to the measured results. The count rates for the calculated results were obtained by dividing the total line count in the list-mode file (equivalent to the total number of absorptions in the NPOD detectors) by the total run time. The count rates are identical for both codes, and they both produce the same multiplicity and inferred k values regardless of measurement time as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Limits on Subcritical Reactivity Determination using Rossi-α and Related Methods

The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/ 235 U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$\$$ and 70$\$$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (KCODE) mode in MCNP®6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossi-α method. The measurements are taken using a 3 He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is -199:4±4:4 s -1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be -8:5 x 10 -5 s -1 . The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when k eff > 0:80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Momentum Users Guide

Momentum is software, written Mark Smith-Nelson, to analyze neutron list-mode data. It contains some features specific to the MC-15 and NPOD neutron multiplicity counters. The MC-15 contains 15 3 He tubes and electronics for recording, in list mode, the time and tube number for each neutron detection. The data depends on many different parameters, including the source material type, source mass and enrichment, alpha ratio, detection efficiency, and multiplication. If some minimum number of these parameters is known, then Momentum can be used to calculate the remaining parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of HEU Measurements Using Measured and Simulated Data [Slides]

Correlated neutron data analyzed using the Feynman Variance-to-Mean method can be used to assess the multiplication and mass of special nuclear material (SNM) systems. After list-mode data are acquired, the multiplication and mass can be determined using detector parameters. This work compares data sets that were measured to simulated data using recent MCNP list-mode modifications. In addition, both sets of data are analyzed using both measured and simulated parameters to infer the system multiplication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

A Comparison of Amplitude-Based and Phase-Based Positron Emission Tomography Gating Algorithms for Segmentation of Internal Target Volumes of Tumors Subject to Respiratory Motion

Purpose: To quantitatively compare the accuracy of tumor volume segmentation in amplitude-based and phase-based respiratory gating algorithms in respiratory-correlated positron emission tomography (PET). Methods and Materials: List-mode fluorodeoxyglucose-PET data was acquired for 10 patients with a total of 12 fluorodeoxyglucose-avid tumors and 9 lymph nodes. Additionally, a phantom experiment was performed in which 4 plastic butyrate spheres with inner diameters ranging from 1 to 4 cm were imaged as they underwent 1-dimensional motion based on 2 measured patient breathing trajectories. PET list-mode data were gated into 8 bins using 2 amplitude-based (equal amplitude bins [A1] and equal counts per bin [A2]) and 2 temporal phase-based gating algorithms. Gated images were segmented using a commercially available gradient-based technique and a fixed 40% threshold of maximum uptake. Internal target volumes (ITVs) were generated by taking the union of all 8 contours per gated image. Segmented phantom ITVs were compared with their respective ground-truth ITVs, defined as the volume subtended by the tumor model positions covering 99% of breathing amplitude. Superior-inferior distances between sphere centroids in the end-inhale and end-exhale phases were also calculated. Results: Tumor ITVs from amplitude-based methods were significantly larger than those from temporal-based techniques (P=.002). For lymph nodes, A2 resulted in ITVs that were significantly larger than either of the temporal-based techniques (P<.0323). A1 produced the largest and most accurate ITVs for spheres with diameters of ≥2 cm (P=.002). No significant difference was shown between algorithms in the 1-cm sphere data set. For phantom spheres, amplitude-based methods recovered an average of 9.5% more motion displacement than temporal-based methods under regular breathing conditions and an average of 45.7% more in the presence of baseline drift (P<.001). Conclusions: Target volumes in images generated from amplitude-based gating are larger and more accurate, at levels that are potentially clinically significant, compared with those from temporal phase-based gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗