Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Leak Detection Technologies for Low Global Warming Potential (GWP), Flammable Refrigerants

Current commercial refrigeration systems use refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The emergence of low GWP alternatives (GWP <150) is expected to significantly reduce direct emissions in this sector, playing a crucial role in the ongoing electrification and decarbonization initiatives. However, many of these low GWP alternatives pose a flammability risk, necessitating robust sensing solutions to ensure the reliable and safe operation of the equipment. This paper examines various sensing mechanisms suitable for potential applications in systems that employ flammable refrigerants, specifically those designated as A2L class. It provides a summary of A2L refrigerants and their properties, followed by a comprehensive review of sensor classes, covering their working principles, features, advantages, and limitations. Additionally, the article delves into key performance characteristics such as accuracy, selectivity, sensitivity, dynamic characteristics, and durability, among other properties. The article discusses areas for improvement and suggests corresponding approaches for potential sensors in facilitating the successful adoption of flammable refrigerants. Finally, this paper presents the latest findings from experimental evaluation of 5 different sensing principles in detecting the composition variation as a result of various operational conditions. Reliability and sensitivity of the sensor in responding to shifts in true composition and the resultant LFL value is also discussed.

Reshniak, Viktor↗

Dynamic model-based feature extraction for fault detection and diagnosis of a supermarket refrigeration system

With the increasing concerns over climate change and carbon emissions, fault detection and diagnostics (FDD) of low–global warming potential (GWP) refrigerant supermarket refrigeration systems has gained great attention from academic and industrial sectors. Various FDD approaches have been developed to detect, identify, and diagnose faults to save energy, improve food quality, and protect the environment. Here, to mitigate the difficulty of collecting high-quality steady-state operational data in field operations faced by most model-based FDD methods, this study developed dynamic models of a low–GWP refrigerant (CO 2 ) supermarket refrigeration system. The model accuracy was validated using manufacturer data and experimental data. Simulations were conducted to predict the system dynamic response under two common operational faults—evaporator air path blockage fault and the display case door open fault—to identify fault patterns and define key dynamic behavior indexes for supporting FDD algorithm development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated fault detection and diagnosis deployment Internet of Things solution for building energy system

The building sector is the highest energy consumer and ranks first in terms of carbon emissions among all sectors. To address these issues, decarbonization and electrification in the building energy sector are two critical missions of the new US administration. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50–52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostic (AFDD) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. Here, this study reviews existing IoT solutions developed for building energy–related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

42 ENGINEERING↗

Decarbonizing HVAC and Water Heating in Commercial Buildings

This report is intended to provide building owners and facilities engineers with heating electrification options and design considerations, as well as additional resources on key topics. The document focuses on the electrification of space heating and water heating loads using electric heat pump systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration

A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigation of safety and environmental challenges posed by refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of mildly and highly flammable refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants. A method to mitigate the safety risk in a flammable refrigerant based heating, ventilation, air-conditioning, and refrigeration (HVACR) system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Quantitative analysis reveals the adsorbent's effectiveness in reducing leak potential in the range of 40 %–100 % for various refrigerants. Strategic placement and active leak management with negative pressure offer promising avenues for capturing leaked refrigerants, enhancing overall safety.

42 ENGINEERING↗

In tube condensation of low global warming potential refrigerants in an axial micro-fin aluminum tube

Environmental regulations have driven the development of refrigerants with low global warming potential (GWP). To design heat exchangers using these new refrigerants, data are needed concerning the heat transfer coefficient and pressure drop in two-phase flow. Another change is the increasing use of aluminum tubes rather than copper tubes to reduce heat exchanger cost. Hence, this study presents an experimental investigation of flow condensation using an expanded axial micro-fin aluminum tube with a fin-tip diameter of 5.96 mm. Here, the experiments included single compounds R-32, R-1234yf, and R-1234ze(E), zeotropic mixtures with low glide (R-454B), and zeotropic mixtures with high-glide (R-454C and R-455A). Experiments were conducted at condensation temperatures ranging from 40 °C to 50 °C, reduced pressures ranging from 0.21 to 0.55, and mass fluxes ranging from 150 to 350 kg/(m 2 s). Data obtained for these refrigerants constitute one of the first reports for high-glide refrigerants using axial micro-fin aluminum tubes. An evaluation of heat transfer degradation of zeotropic mixtures due to mass transfer resistance at the liquid/vapor interface is presented. This information can be used to design heat exchangers for next generation air conditioning and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Technologies Office 03.02.02.38 Milestone Report—Compressor Technology Development for Refrigerants with <150 Global Warming Potential

The major purpose of this project is to enable the development of compressors specifically designed for compatibility with low–global warming potential (GWP) refrigerants (with GWP values below 150). These compressors are intended for applications in residential and light commercial air-conditioning and heat pump systems. This report contains an exhaustive review of the existing literature with the intention of discerning the most efficacious methodologies currently in use for compressor modeling. This fundamental stage was designed to foster a comprehensive understanding of the intricate dynamics and mechanics of compressors. As a result, a model (PDSim) was selected to simulate scroll, rotary and linear compressor technologies.

42 ENGINEERING↗