Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Temperature Microgravity Space ISS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 records · Page 3

Processing of Packing Foams Using Heat Melt Compaction

Foam is used extensively as packing material for items sent to the International Space Station (ISS). Although lightweight, foam is bulky and can occupy a large fraction of the limited ISS volume. Four chemically distinct foams have been used on the ISS. In descending order of current usage, these are Plastazote Zotek Minicel Pyrell. Processing foam with the Heat Melt Compactor (HMC), a solid waste treatment system, has been proposed to reduce the volume of foams stored on spacecraft. Prior to HMC testing, Thermogravimetric Analyses were conducted on the four foams as a precaution to ensure that the thermal decomposition temperatures were not within range of HMC operation (180C). Pyrell was not tested with the HMC because it is known to release toxic compounds and comprises less than 1.5 of total foam usage on ISS resupply flights. Zotek, Minicel, Plastazote LD24FR (low density), and Plastazote LD45FR (high density) were processed with the HMC at 130, 150 and 170C. Volume was reduced by 82.6 on average (n19; std dev4.88). Hydrocarbons and several other compounds emitted during foam processing were measured using a Total Hydrocarbon Analyzer and FTIR. Effects of process temperature and foam type on exhaust composition are discussed. Feeding of foams into the limited size opening of the HMC compaction chamber is likely to be a challenge, particularly in microgravity. Some suggestions are proposed to facilitate feeding foam into the HMC. Processing packing foam with the HMC has been shown to substantially reduce foam volume, and also has the potential benefit of producing radiation-shielding foam tiles.

Harris, Linden↗

Vapor Growth of ZnSe-based Compound Semiconductors in Low Gravity environment on International Space Station

Six low-gravity experiments of crystal growth of ZnSe-based compound semiconductors by physical vapor transport (PVT) are scheduled to be processed inside Low Gradient Furnace (LGF) on Materials Science Research Rack (MSRR) in Material Science Laboratory (MSL) on International Space Station (ISS) starting from February 27th, 2023. The flight samples consist of three unseeded growths of ZnSe, Cr-doped ZnSe and ZnSeTe as well as growth of ZnSe on top of three single crystal ZnSe seeds with orientation of (100), (110) and (111). The main scientific objective of the flight experiments is to establish the effects of gravity-driven fluid flows on Earth to (i) the non-uniform incorporation of impurities and defects and (ii) the deviation from stoichiometry observed in the grown crystals caused by growth interface fluctuations and evolution as the results of buoyancy-driven convection and irregular fluid-flows. The investigation will also evaluate the effects of gravity on the PVT process by examining (i) the growth kinetics on various seed orientations, (ii) the dopant segregation and distribution in the Cr doped ZnSe, and (iii) the compositional segregation and distribution in the ternary ZnSeTe crystal grown by PVT. Additionally, from X-ray diffraction/topography and by measuring the density and distribution of various crystalline defects it will assess the self-induced strain effects developed during processing at elevated temperatures caused by the weight of the crystals. During the ground-based preparations, the following tasks have been accomplished: • Establish the thermodynamic properties of the ZnSe binary and related ternary systems by measuring the partial pressures of the vapor phase coexisting with the condensed phases and perform phase diagram calculations for comparison. • Evaluate the effects of gravity-driven convection in the growth process by performing experiments under various vapor transport orientations relative to gravity vector, i.e., horizontal, vertically stabilized and destabilized configurations. • Establish a quantitative correlation between growth parameters and the characteristics and properties of the grown crystals by characterizing the crystals using a variety of techniques. • Evaluate the fundamentals of the current theories on vapor transport and crystal growth kinetics by performing in-situ and real-time monitoring techniques during growth. • Develop a one-dimensional diffusion limited theory of mass transport and two- and three-dimensional numerical simulations of both mass transport and heat transfer and thus establish the microgravity requirements for the flight experiments and to predict the characteristics of the grown crystals such as the solid-vapor interface shapes… etc. and establish a fundamental understanding of the crystal growth process from the comparison with experimental results.

ZnSe↗

Experimental Heat Transfer Results and Flow Visualization of Vertical Upflow Boiling in Earth Gravity with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.

flow boiling↗

Flow Visualization, Heat Transfer, and Critical Heat Flux of Flow Boiling in Earth Gravity with Saturated Liquid-Vapor Mixture Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

This study investigates flow boiling of n-Perfluorohexane with saturated two-phase mixture inlet in a rectangular channel of dimensions 114.6-mm heated length, 2.5-mm width, and 5 mm-height. The experiments were performed as part of the Mission Sequence Testing of the Flow Boiling and Condensation Experiment’s (FBCE) Flow Boiling Module (FBM) in the vertical upflow configuration in Earth gravity using the same experimental system that was launched to the International Space Station (ISS) in August 2021. The operating parameters varied are heating configuration (single- and double-sided), mass velocity (380 – 2400 kg/m2s), inlet quality (0.011 – 0.519), and inlet pressure (120 – 179 kPa). High-speed video photographs are presented to explain the two-phase flow patterns within the channel’s heated length. Flow patterns are constituted by low-density and high-density fronts moving along the channel, with the high-density fronts gradually reducing in length due to evaporation. Heat transfer results in terms of flow boiling curves, streamwise wall temperature profiles, streamwise heat transfer coefficient profiles, and average heat transfer coefficients are presented and trends discussed. CHF data from the present experiments are combined with prior databases to compile a consolidated FBCE-CHF database for saturated inlet to expand the ranges of operating conditions and include other flow orientations in Earth gravity. Experimental CHF trends are also discussed. The interfacial lift-off model shows a good CHF predictive accuracy evidenced by a mean absolute error of 11.97% for this consolidated database after constraining it to mass velocities greater than or equal to 500 kg/m2s. Finally, this study confirmed reliability of the upcoming ISS experiments for saturated inlet conditions and the collected Earth-gravity data will be compared to ISS microgravity data.

Flow boiling↗

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Computed Tomography (CT) has advanced considerably since being responsible for such dramatic advances in diagnostics within the medical field. It has become a major tool in non destructive evaluation (NDE), and is used in many fields as diverse as coal-mining to metal solidification to examination of rock cores. A review of industrial applications has been written by Dennis. It is only recently that the technique has been seriously used to determine composition through precise measurement of density. While such applications are restricted to cases when there is no ambiguity in the relationship of composition to density. Thus alloy solid solutions lend themselves to compositional analysis provided there is a large change in density with composition. The technique is most useful when rapid non-destructive evaluation is needed. Such cases will occur with samples returning from the International Space Station (ISS) when knowledge of the results could affect future strategies for processing of on-board samples. Experiments from those Principal Investigators (PI) that are most likely to benefit from early CT scanning are discussed. With a dearth of samples, the major emphasis in the first part of this project has been on preparing suitable standards, optimizing the CT technique for these applications, and using the CT system to determine density variations with temperature. An interesting application of CT has been in the examination of meteorites, which can be classified as space-grown materials and will certainly have solidified in a low gravity environment.

Gillies, Donald C.↗

Design of Experiment for the Measurement of Aerosol Droplet Size Distribution of Temperature-Controlled Thermally Atomized Printed Electronic Inks

In-Space Manufacturing (ISM) centers around NASA’s growing need and ability to produce space technologies on demand in space. As the future of long term presence in space and deep space exploration approach, fundamental questions of our dependence on earth resupply to Low Earth Orbit (LEO) remain unanswered. ISM is leading various effort to evaluate the feasibility of producing essential spares and redundant parts on demand to enable a sustainable space-based supply chain model for part resupply. Among the parts and systems being considered, Avionics form the neural network of modern day aircraft and space vehicles providing a wealth of information ranging from Guidance, Navigation, and Control (GN&C) systems to on board Environmental Control and Life Support (ECLS) systems. Recent advances in the use of Aerosol Jet Technology to print Avionics components ranging from electrical traces on a circuit board to complex transistors and sensors raise the possibility of using such technology to reproduce or recreate electronic parts on demand with the help of custom electronics 3D printers. The challenge herein lies within the ability of such printers to generate and deposit an aerosol of electronic material utilizing processes independent of or enhanced by gravity to ensure controllably identical or improved behavior of the aerosol in an International Space Station (ISS) laboratory and on the ground. The behavior as well as the hazards and properties associated with such aerosols in a microgravity environment must be understood well in order to merit a feasible approach to utilizing them for manufacturing in space. In this report, we outline the experimental setup of a modified conventional vaping device to be used as the ideal gravity independent thermal atomization mechanism to generate aerosol. Our objective is to identify the ideal mass, density, and volume of our aerosolized droplets of ink to conclude that there exist a threshold of aerosolized ink droplet sizes that are indeed independent of the effects of gravity and remain stable after atomization. We use a Malvern Spraytec® Spray Particle Size Analyzer to perform real-time laser diffraction measurement of our ink droplets during atomization. The droplet size between conductive ink, dielectric ink and vegetable glycerin have been measured and contrasted. Furthermore, the mechanism of thermal atomization versus traditional pneumatic and ultrasonic atomization for operation in microgravity have been explored.

Wu, Chih-Hao↗

Heat Transfer and Interfacial Flow Physics of Microgravity Flow Boiling in Single-Side-Heated Rectangular Channel with Subcooled Inlet Conditions – Experiments Onboard the International Space Station

This study is the culmination of a long-term collaborative effort between researchers from the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center to investigate gravitational effects on flow boiling and flow condensation. The science and design concepts for this large-scale effort were initiated in 2011 and included several studies detailing various aspects of two-phase fluid physics in both Earth gravity and microgravity, culminating in construction of the large-scale experimental facility named “Flow Boiling and Condensation Experiment (FBCE)”. The experiment was launched to the International Space Station (ISS) in August 2021. Following the successful installation of FBCE, equipped with the Flow Boiling Module (FBM), onboard the ISS and completion of several safety checks, flow boiling experiments were performed for five months from February 2022 until July 2022. This resulted in a large flow boiling database covering broad ranges of operating parameters and heating configurations spanning several research objectives. This study investigates microgravity flow boiling of n-perfluorohexane with subcooled inlet in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m 2 s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Images and image sequences acquired via high-speed-video are presented to elucidate the interfacial flow physics. To analyze and explain the effects of various parameters in microgravity, heat transfer results are presented as flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient. Mass velocity and inlet subcooling significantly influenced most of the aforementioned aspects of flow boiling, whereas effects of inlet pressure were comparatively insignificant. Although the data and observed flow physics might be different, the parametric effects and trends in microgravity are similar to vertical upflow in Earth gravity. Some cases, especially low mass velocities, high heat fluxes, and large degrees of inlet subcooling, experienced temporally anomalous flow behaviors caused by two-phase flow instabilities manifesting as flow reversals and resulted in deviations in overall trends. Severe thermodynamic non-equilibrium is observed throughout the channel. Overall, FBCE’s ISS experiments were successful for subcooled inlet with single-sided heating of rectangular channel, and the collected data well established the various effects on flow boiling physics in highly controlled long-term microgravity conditions.

flow boiling↗

The Fast Alternative Cryogenic Experiment Testbed

One of the challenges in the area of cryogenics for space exploration in the next millennium is providing the capability for inexpensive, frequent, access to space. Faced with this challenge during the International Space Station (ISS) build era, when other Space Shuttle manifesting opportunities are unavailable, a "proof of concept" cryostat has been developed to demonstrate the ability to accommodate low temperature science investigations within the constraints of the Hitchhiker siderail carrier. The Hitchhiker siderail carrier is available on a "mass available" basis during the ISS build era. In fact, several hitchhiker payloads flew with the deployment of the Unity module. Hitchhiker siderail carrier payloads have historically flown an average of about four times a year. A hybrid Solid Neon - Superfluid Helium cryostat has been developed with Janis Research Company to accommodate instruments of 16.5 cm diameter and 30 cm. length. This hybrid approach was taken in part to provide adequate on-orbit lifetime for instruments with high (conducted) heat loads from the instrumentation wiring. Mass, volume, lifetime and the launch hold scenario were all design drivers. In addition, with Ball Aerospace and Technologies Corporation, a multichannel VME architecture Germanium Resistance Thermometer (GRT) readout and heater control servo system has been developed. In a flight system, the cryostat and electronics payloads would be umbilically attached in a paired Hitchhiker siderail mount, and permit on-orbit command and telemetry capability. The results of performance tests of both the cryostat, and a helium sample instrument will be presented. The instrument features a self contained, miniaturized, nano-Kelvin resolution High Resolution Thermometer (HRT). This high level of thermal resolution is achieved through the utilization of a dc Superconducting Quantum Interference Device (SQUID). Although developed for the Low Temperature Microgravity Fundamental Physics investigator community, many design features are applicable in fields such as infrared and x-ray astronomy.

Nash, Alfred↗

Acoustic Issues in Human Spaceflight

NASA is concerned about acute effect of sound on crew performance on International Space Station (ISS), and is developing strategies to assess and reduce acute, chronic, and delayed effects of sound. High noise levels can cause headaches, irritation, fatigue, impaired sleep, headache, and tinnitus and have resulted in an inability to hear alarms. Speech intelligibility may be more impaired for crew understanding non-native language in a noisy environment. No hearing loss occurred, but significant effects on crew performance and communication occurred. Permanent Threshold Shifts (PTS) have not been observed in the US shuttle program. Russian specification for noise in spacecraft is 60 dBA (awake) and 50 dBA (asleep) while the U.S. noise specification on ISS is NC 50 (awake) and NC 40 (asleep) with a 85 dBA hazard limit. Background noise levels of ISS modules have measured 56-69 dBA. Treadmill exercise operations measure 77 dBA. Alarms are required to be 20 dBA above ambient. Hearing protection is recommended when noise exceeds 60 dB 24 hour Leq. Countermeasures include hearing protection and design/ engineering controls. Advanced composite materials with excellent low frequency attenuation properties could be applied as a barrier protection around noisy equipment, or used on personal protective equipment worn by the crew. Hearing protection countermeasures include foam ear inserts, passive muff headsets, and active noise reduction headsets. Oto-acoustic emissions (OAE) could be used to monitor effectiveness of hearing protection countermeasures and tailor hearing protection countermeasures to individual crewmembers. Micro-gravity, vibration, toxic fumes, air quality/composition, stress, temperature, physical exertion or some combination of the above factors may have interacted with moderate long-term noise exposure to cause significant hearing loss. Longitudinal studies will need to address what co-morbidity factors, such as radiation, toxicology, microgravity effects (fluid shift), aging, are involved with hearing loss.

Clark, Jonathan B.↗

Computed Tomography Support for Microgravity Materials Science Experiments

The accurate measurement of density in both liquid and solid samples is of considerable interest to Principal Investigators with materials science experiments slated for the ISS. The work to be described is an innovative application of a conventional industrial nondestructive evaluation instrument. Traditional applications of industrial computed tomography (CT) rely on reconstructing cross sections of large structures to provide two-dimensional planar views which can identify defects such as porosity, or other material anomalies. This has been done on microgravity materials science experiments to check the integrity of ampoule-cartridge assemblies for safety purposes. With a substantially monoenergetic flux, as can be obtained with a radioactive cobalt source, there will be a direct correlation between absorption and density. Under such conditions it then becomes possible to make accurate measurements of density throughout a sample, and even when the sample itself is enclosed within a furnace and a safety required cartridge. Such a system has been installed at Kennedy Space Center (KSC) and is available to PIs to examine samples before and after flight. The CT system is being used to provide density information for two purposes. Firstly, the determination of density changes from liquid to solid is vital information to the PI for purposes of modeling the solidification behavior of his sample, and to engineers who have to design containment ampoules and must allow for shrinkage and other volume changes that may occur during processing. While such information can be obtained by pycnometric measurements, the possibility of using a furnace installed on the CT system enables one to examine potentially dangerous materials having high vapor pressures, while not needing visible access to the material. In addition, uniform temperature can readily be obtained, and the system can be controlled to ramp up, hold, and ramp down while collecting data over a wide range of parameters automatically. Results of initial tests on low melting point elements such as gallium, indium and tin will be presented, and the intent is to proceed to compounds such as InSb, HgCdTe and CdTe. Alloys such as Pb-Sb (PI - Poirier, U AZ) and Cu-Al (PI - Trivedi, Ames Lab.), which are the subjects of flight experiments, will also be examined. The second application is the conversion of measured density values directly to composition. This was successfully done with the mercury cadmium telluride alloys grown on the second and fourth United States Microgravity Payload (USMP-2 and USMP-4) missions by Lehoczky. CdTe values along the length of the boules were obtained at KSC prior to cutting the sample, and could have been obtained prior to its removal from the cartridge and ampoule. Examples of the data obtained will be shown. It is anticipated that several of the materials science PIs will avail themselves of the technique described, initially for determining densities prior to flight, and then to acquire early quantitative data on the compositional variation within their samples.

Gillies, Donald C.↗