Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low threshold detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Superconducting quasiparticle-amplifying transmon: A qubit-based sensor for meV-scale phonons and single terahertz photons

With great interest from the quantum computing community, an immense amount of R&D effort has been invested into improving superconducting qubits. The technologies developed for the design and fabrication of these qubits can be directly applied to applications for ultralow-threshold particle detectors, e.g., low-mass dark matter and far-infrared photon sensing. We propose a novel energy-resolving sensor based on the transmon qubit architecture combined with a signal-enhancing superconducting quasiparticle amplification stage. We refer to these sensors as SQUATs: superconducting quasiparticle-amplifying transmons. We detail the operating principle and design of this new sensor and predict that, with minimal R&D effort, solid-state-based detectors patterned with these sensors can achieve sensitivity to single terahertz photons, and sensitivity to 1 meV phonons in the detector absorber substrate on the microsecond timescale. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Land altimetry using satellite data from the GEOSAT sea altimeter

Several techniques are proposed or assessed from the GEOSAT sea altimeter, and changes are recommended in future RADAR altimeters. The first technique tried was to cross-correlate each waveform with the preceding one. Then the position giving the maximum correlation was taken as the correct placement of the new waveform in its data window. The resulting altitude profile was slightly more variable than that of the on-board tracker over flat rock (Salar de Uyuni), so apparently successive waveforms are too dissimilar to correlate. When cross-correlation failed, compensation was made for averaging. Raw waveforms are averaged in groups of 100 and it is these average waveforms which are available for ground processing. But while the 100 are being received, the window position is moved in time, at different constant rates for the first 50 and last 50. Assuming an unchanging waveform and a single window rate for the 100, first and last waveforms were obtained. Averaging their half-height arrival times gave an altitude profile similar to the median and centroid methods. The variability of this altitude profile suggests that even raw waveforms in a group of 100 may be too dissimilar to correlate. In other techniques, the pulse was judged to have arrived when one of these criteria was met: the wave amplitude meets a certain absolute threshold; wave amplitude meets a certain relative threshold; certain fraction of the area of the waveform has passed; and centroid of the waveform has passed. All methods gave altitude profiles at least as variable as the on-board tracker, and all were biased at least 0.5 meter to low altitudes, except the threshold detector. The threshold detector can be filtered spatially to resemble the on-board tracker, and perhaps it could be implemented without feedback. For operating over land, these changes are recommended in future altimeters: The window should not move while raw waveforms are being averaged; some of the raw waveforms should be telemetered to earth for study, placing the waveform in the window should allow for shape variety; and some form of threshold detector might be used to find the signal and place it.

Luft, Philip E.↗

Pursuing the Ultimate Power of Xenon Dark Matter Detectors (Annual Progress Report)

Liquid xenon-based experiments have been leading direct searches for dark matter – a cornerstone of modern cosmology and particle physics. Despite rapid improvement of experimental sensitivities in the past two decades, no definitive dark matter interactions have been observed. This project aims to expand the physics reach of existing and future xenon dark matter experiments, especially for low-mass dark matter interactions that would fall below the energy thresholds of current detectors. The main approach is to thoroughly characterize and to suppress the low-energy electron background observed in dual-phase xenon Time Projection Chambers (TPCs), which has so far prevented these detectors from achieving lower energy thresholds. Per recent discussion with and approval from the program manager, we have added a new task of experimentally measuring the Migdal effect to this project. The Migdal effect predicts that ultra-low energy dark matter interactions may produce detectable electron recoil signals in liquid xenon at the keV level in addition to much lower energy nuclear recoils. If this effect is experimentally measured, it will drastically improve xenon detectors’ sensitivity to subGeV dark matter interactions. This new task shares strong synergy with the original project goal of pursuing the ultimate power of xenon dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The physics potential of a reactor neutrino experiment with Skipper-CCDs: searching for new physics with light mediators

In this work, we explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of models which benefit from the very low energy recoil threshold of these detectors, namely neutrino magnetic moments and light mediators coupled to neutrinos and quarks or electrons. We find that this experimental setup is very sensitive to light, weakly coupled new physics, and in particular that it could probe potential explanations of the event excess observed in XENON1T. We also provide a detailed study on the dependence of the sensitivity on the experimental setup assumptions and on the neutrino flux systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE experiment physics

The Deep Underground Neutrino Experiment (DUNE) will feature a 40-kton liquid argon TPC detector situated a mile below the surface at the Sanford Underground Research Facility. A new broadband high-intensity neutrino source and Near Detector complex will be located at Fermilab, 1300 kilometers away. This arrangement will provide unprecedented sensitivity in the search for neutrino CP violation, determination of the neutrino mass ordering, and precision measurements of neutrino mixing parameters. The underground Far Detector also allows for low background, low threshold observations of supernova neutrinos, with a unique sensitivity to the electron neutrino flux. Further, DUNE will conduct a wide range of searches for physics beyond the Standard Model, including baryon number violation, rare scattering processes, and non-standard flavor transitions. In this poster, we review DUNE's extensive physics program and show updated sensitivities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass2021 Cosmic Frontier White Paper: Puzzling Excesses in Dark Matter Searches and How to Resolve Them

Intriguing signals with excesses over expected backgrounds have been observed in many astrophysical and terrestrial settings, which could potentially have a dark matter origin. Astrophysical excesses include the Galactic Center GeV gamma-ray excess detected by the Fermi Gamma-Ray Space Telescope, the AMS antiproton and positron excesses, and the 511 and 3.5 keV X-ray lines. Direct detection excesses include the DAMA/LIBRA annual modulation signal, the XENON1T excess, and low-threshold excesses in solid state detectors. We discuss avenues to resolve these excesses, with actions the field can take over the next several years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development Status of the KIPM Detector Consortium

A kinetic inductance phonon-mediated detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasi-particle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs. However, due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320 eV. Finally, the current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-T c superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors.

Temples, Dylan J. [Fermi National Accelerator Labo↗

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors

Abstract P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p $$^+$$ + surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the Majorana Demonstrator experiment, a search for neutrinoless double-beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in $$^{76}$$ 76 Ge. $$\alpha $$ α decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $$\alpha $$ α identification, reliably identifying $$\alpha $$ α background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $$\alpha $$ α events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $$0\nu \beta \beta $$ 0 ν β β region of interest window by an order of magnitude in the Majorana Demonstrator and will be used in the upcoming LEGEND-200 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗