Search NASASearch

SEARCH · Search NASA

Results for “MAGNETIC TAPE RECORDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

DSIF FR-900 video recorders

Deep Space Instrumentation Facility FR-900 ROTARY head magnetic tape recorders for acquiring video data from lunar orbiter

MAGNETIC TAPE RECORDER

Radiometric images on IR reststrahlen emission from rock surfaces

In order to test the feasibility of remote sensing of the reststrahlen effect, a two-channel radiometer was constructed that sensed radiance in two channels simultaneously. The channels selected were 8.3 to 9.3 and 10.2 to 11.2 micrometers. The instrument had an instantaneous geometric field of view of 2 deg x 2 deg and a rotating mirror scan mechanism designed to produce contiguous scans from a DC-3 aircraft at approximately 10,000 ft. altitude. Signals were recorded on a magnetic tape recorder and subsequently converted to equivalent black body temperature for both channels. Results of measurements made over a number of rock types in the Maryland-Pennsylvania region are briefly discussed.

Hovis, W. A.

A high data rate recorder for astronomy

A magnetic tape recorder developed for the special requirements of radio astronomy and geodesy is described. These requirements include a high bit packing density and long record times. The current version of this longitudinal recorder used by the Very Long Baseline Array (VLBA) records 5.5 Terabits on a 14-in diameter reel of inch-wide tape. A maximum record rate of 256 Mb/s is achieved in the VLBA configuration with one recorder operating at 4 ms and utilizing 32 of the heads in a single stack. The VLBA recorders have been tested using a longitudinal density of 2.25 fr/micron; 448 data + 56 system tracks are recorded in 14 passes, each lasting 50 min, for a total record time (at 128 Mb/s) of 12 h on 14-in diameter reel of inch-wide 13-microns-thick D1-equivalent tape.

Hinteregger, H. F.

Fracture behavior of large-scale thin-sheet aluminum alloy

A series of fracture tests on large-scale, pre-cracked, aluminum alloy panels is being carried out to examine and to characterize the process by which cracks propagate and link up in this material. Extended grips and test fixtures were specially designed to enable the panel specimens to be loaded in tension, in a 1780-kN-capacity universal testing machine. Twelve panel specimens, each consisting of a single sheet of bare 2024-T3 aluminum alloy, 3988 mm high, 2286 mm wide, and 1.016 mm thick are being fabricated with simulated through-cracks oriented horizontally at mid-height. Using existing information, a test matrix has been set up that explores regions of failure that are controlled by fracture mechanics, with additional tests near the boundary between plastic collapse and fracture. In addition, a variety of multiple site damage (MSD) configurations have been included to distinguish between various proposed linkage mechanisms. All tests but one use anti-buckling guides. At this writing seven specimens have been tested. Three were fabricated with a single central crack, three others had multiple cracks on each side of the central crack, and one had a single crack but no anti-buckling guides. Each fracture event was recorded on film, video, computer, magnetic tape, and occasionally optical microscopy. The visual showed the crack tip with a load meter in the field of view, using motion picture film for one tip and SVHS video tape for the other. The computer recorded the output of the testing machine load cell, the stroke, and twelve strain gages at 1.5 second intervals. A wideband FM magnetic tape recorder was used to record data from the same sources. The data were analyzed by two different procedures: (1) the plastic zone model based on the residual strength diagram; and (2) the R-curve. The first three tests were used to determine the basic material properties, and these results were then used in the analysis of the two subsequent tests with MSD cracks. There is good agreement between measured values and results obtained from the model.

Dewit, Roland

Instrumentation and control system for an F-15 stall/spin

An instrumentation and control system is described that was used for radio-controlled F-15 airplane model stall/spin research at the NASA-Langley Research Center. This stall/spin research technique, using scale model aircraft, provides information on the post-stall and spin-entry characteristics of full-scale aircraft. The instrumentation described provides measurements of flight parameters such as angle of attack and sideslip, airspeed, control-surface position, and three-axis rotation rates; these data are recorded on an onboard magnetic tape recorder. The proportional radio control system, which utilizes analog potentiometric signals generated from ground-based pilot inputs, and the ground-based system used in the flight operation are also described.

Pitts, F. L.

In-flight jet engine noise measurement system

An instrumentation system in flight tests for noise research is described which utilizes miniature transducers to measure low-amplitude, high-frequency fluctuating pressures in a jet engine mounted under the wing of a turboprop aircraft. The system employs a rotor-mounted FM telemeter to acquire data from eight fan-blade-mounted transducers which are subjected to up to 75,000 g's of loading. Data is transmitted from the rotor to an antenna mounted in the inlet-duct wall using a low-power, close-coupled RF link. The blade pressures and other inlet and stator-vane fluctuating pressures are recorded on airborne, magnetic-tape recorders. The flight instrumentation described also includes PCM techniques to encode and record a variety of quasi-static measurements to provide engine and aircraft performance data. The instrumentation and experimental measurements are of value to an improved understanding of noise sources in jet engines and for the advancement of jet-engine ground noise testing techniques.

Knight, V. H., Jr.

Ultra-high density recording technologies

The Engineering Research Center in Data Storage Systems at Carnegie Mellon University in cooperation with the National Storage Industry Consortium has selected goals of achieving 10 Gbit/sq in. recording density in magnetic and magneto-optic disk recording and 1 terabyte/cubic in. magnetic tape recording technologies. This talk describes the approaches being taken and the status of research leading to these goals.

Kryder, Mark H.

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 3

The following subjects were covered: (1) ASM80 manual, (2) signal preprocessing as an aid to on-line EKG analysis, and (3) high speed evaluation of magnetic tape recordings of electrocardiograms. A description of the ASM80 symbolic assembly program for the INTEL 8080 microprocessor and a user's manual were presented. The capability of three redundancy reduction algorithms to produce adequate representations of electrocardiographic data was examined. A hardware device was constructed which carried out zero order interpolation on a signal. Examination of the zero order interpolators reconstructed signal indicated that this representation was adequate for analysis of rhythm. A system to analyze magnetic tapes of electrocardiograms recorded over 24 hour intervals was designed. The recordings are sampled 200 times per second using a Nova computer and a special interface system. This system was tested on several recordings of clinical data, containing over 75 premature ventricular contractions, each one of which was flagged.

Mark, R. G.