In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and DigitalFluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, LosAngeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since thesuccessful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the groundcalibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluatetwelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers usingalgorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF,UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tonesand harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA.IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolutegains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS andgive examples of the quality of the resulting calibrations.

Electromagnetic field Measurements

Assessing and Ensuring GOES-R Magnetometer Accuracy

The GOES-R magnetometer subsystem accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. Error comes both from outside the magnetometers, e.g. spacecraft fields and misalignments, as well as inside, e.g. zero offset and scale factor errors. Because zero offset and scale factor drift over time, it will be necessary to perform annual calibration maneuvers. To predict performance before launch, we have used Monte Carlo simulations and covariance analysis. Both behave as expected, and their accuracy predictions agree within 30%. With the proposed calibration regimen, both suggest that the GOES-R magnetometer subsystem will meet its accuracy requirements.

Magnetometer

GOES-17 Magnetometer On-Orbit Calibration Design and Results

The Geostationary Operational Environmental Satellite-R (GOES-R) is a series of four NOAA weather satellites. Each spacecraft flies a Magnetometer instrument which includes two boom mounted fluxgate sensors located 6.3 and 8.5 meters from the spacecraft. Sensor readings are corrupted by both internal (bias and scale factor) and external (spacecraft emitted fields and misalignments) error sources. In order to estimate the bias, an on-orbit calibration is performed, slewing the spacecraft about multiple axes and then performing a fit of the data to determine zero offset and misalignment terms. The first satellite in the series, GOES-16 was launched in November 2016. Its magnetometer calibration maneuver was found to be inadequate providing insufficient rotation about orthogonal axes. The uncertainty in the estimated biases was found to be in the 3-5 nanotesla range, exceeding the magnetometer accuracy requirement of 1.0 nanotesla. Based on lessons learned, the maneuver was redesigned to provide multiple 360 degree rotations about two orthogonal axes, providing optimal visibility into bias and misalignment. Varying ambient fields over the duration of the calibration maneuvers, corrupts the ability to accurately determine parameters of interest. To address this issue, rather than assuming a constant field for the duration of the maneuver, a non-linear least squares filter was employed that uses a series of spline functions to better fit the ambient field. The number of splines can be varied to minimize the least squares filter residuals. Simulations were performed using 360 days of GOES-16 data to bound the uncertainty in the biases for given residuals of the fit to the ambient field. Following the launch of the second satellite in the series, GOES-17 in March 2018, the new calibration maneuver and enhanced bias estimation algorithm were exercised twice. Based on the residuals of the fit, the uncertainty of the estimated zero offset was reduced by an order of magnitude from 3-5 nanotesla to approximately 0.4 nanotesla per axis. This paper provides details of the maneuver design and the innovative algorithm used to estimate the GOES-17 biases and misalignments.

GOES-17

Lunar surface magnetometer experiment

The Apollo 15 lunar-surface magnetometer (LSM) is one of a network of magnetometers that have been deployed on the moon to study intrinsic remanent magnetic fields and global magnetic response of the moon to large-scale solar and terrestrial magnetic fields. From these field measurements, properties of the lunar interior such as magnetic permeability, electrical conductivity, and temperature can be calculated. In addition, correlation with solar-wind-spectrometer data allows study of the the solar-wind plasma interaction with the moon and, in turn, investigation of the resulting absorption of gases and accretion of an ionosphere. These physical parameters and processes determined from magnetometer measurements must be accounted for by comprehensive theories of origin and evolution of the moon and solar system.

Dyal, P.

The use of magnetometers on balloon-borne X-ray astronomy experiments.

The use of magnetometers for azimuth determination of balloon-borne X-ray astronomy payloads is examined, with special emphasis placed on the experiments of the University of Adelaide Cosmic Ray Group. A critical evaluation is made of the effectiveness of the magnetometers, including discussion of effects due to geomagnetic field variations, magnetometer misorientation and spurious contaminant magnetic fields. Calibration techniques and details of in-flight performance are also presented.

Thomas, R. M.

A note on signal enhancement for dual magnetometer systems.

Demonstration of the value of cross-correlation signal enhancement achieved by means of a dual magnetometer system. A unique feature of a dual magnetometer system is, as pointed out by Ness et al. (1971), the opportunity it allows for signal enhancement by using cross-correlation techniques developed in statistical communication theory. Their use is shown to make it possible to overcome the limitations that the intrinsic sensor ambient noise and the measurement-contaminating spacecraft field fluctuations impose upon the signal detection performance of a single magnetometer.

Ness, N. F.

Ground magnetometer survey in the Valley of Ten Thousand Smokes, Alaska

A reconnaissance magnetometer survey was conducted with both total- and vertical-field magnetometers. The large, sharp, narrow total magnetic anomalies observed over a zone of relict fumaroles in Broken Mountain Valley showed spectacular agreement with the surficial geology. Such a correlation is a strong indication that accumulations of magnetic minerals have been preserved along these fissure vents at shallow depths. Since large magnetic anomalies were measured near fumarolic markings along all of the traverses, it is proposed that the retention of sublimates along fumarolic vents is common throughout the Valley. The generally concentric contours of the vertical magnetic anomaly at the head of the Valley suggest that the dome of Novarupta is merely the surficial expression of a very massive conical-shaped intrusive centered just northeast of the dome. The magnetometer survey indicates that the pyroclastics in the Valley may be over 150 meters thick. Such an estimate is compatible with the volume of eruptive material needed to compensate for the subsidence surrounding Novarupta as well as a sizable amount of other regional subsidence.

Trible, M. C.

Lunar electrical conductivity, permeability,and temperature from Apollo magnetometer experiments

Magnetometers were deployed at four Apollo sites on the moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments were used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, were analyzed to calculate and electrical conductivity profile for the moon, and those profiles were used to calculate the lunar temperature for an assumed lunar material of olivine. Simultaneous measurements by magnetometers on the lunar surface and in orbit around the moon were use to construct a whole-moon hysteresis curve, from which the global lunar magnetic permeability is determined. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) was calculated for two assumed compositional models of the lunar interior. Other lunar models with an iron core and with a shallow iron-rich layer also discussed in light of the measured global lunar permeability. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Velocities and thicknesses of the earth's magnetopause and bow shock were also estimated from simultaneous magnetometer measurements.

Dyal, P.

Lunar magnetic permeability studies and magnetometer sensitivity

A regression of quiet magnetic field components simultaneously measured by the two Explorer 35 magnetometers reveals uncertainties in effective sensitivity factors of up to a few percent in one or both of these instruments. Given this, the validity of previous lunar permeability studies based on Explorer 35/ALSEP regressions, wherein inferences are drawn from regression line slopes differing from unity by the order of one percent, is called into question. We emphasize the need to critically address the question of small deviations in magnetometer sensitivity factors from nominal values as a part of any two-magnetometer lunar permeability study.

King, J. H.

Magnetometer with a miniature transducer and automatic scanning

The magnetometer is based on the time variation of the magnetic permeability in the magnetic material of its transducer; however, its operation is substantially different from the ordinary flux-gate magnetometer. The transducer uses 0.05 mm diameter plated magnetic wire and is made flat enabling it to make measurements of transverse magnetic fields as close as 0.08 mm from the surface, and it has very good spatial resolution because of its small active region of approximately 0.64 mm by 0.76 mm. The magnetometer uses an inexpensive clip-on millimeter for driving and processing the electrical signals and readout. It also utilizes an automatic scanning technique which is made possible by a specially designed transducer holding mechanism that replaces the ink pen on an X-Y recorder.

Debnam, W. J. J.

The ISEE-C vector helium magnetometer

The ISEE-C magnetometer will make continuous observations of the interplanetary magnetic field near 1 AU. This paper describes the scientific objectives of the magnetometer experiment and gives attention to instrument design (sensor, electronics, and operating principles). A functional block diagram of the system is presented and attention is given to minor modifications required by the ISEE mission (the magnetometer is essentially one that served as the spare unit for the Pioneer 10 and 11 missions to Jupiter).

Frandsen, A. M. A.

Magnetometer bias determination and attitude determination for near-earth spacecraft

A simple linear-regression algorithm is used to determine simultaneously magnetometer biases, misalignments, and scale factor corrections, as well as the dependence of the measured magnetic field on magnetic control systems. This algorithm has been applied to data from the Seasat-1 and the Atmosphere Explorer Mission-1/Heat Capacity Mapping Mission (AEM-1/HCMM) spacecraft. Results show that complete inflight calibration as described here can improve significantly the accuracy of attitude solutions obtained from magnetometer measurements. This report discusses the difficulties involved in obtaining attitude information from three-axis magnetometers, briefly derives the calibration algorithm, and presents numerical results for the Seasat-1 and AEM-1/HCMM spacecraft.

Lerner, G. M.

A low energy electron magnetometer

The concept of a highly sensitive magnetometer based on the deflection of low energy electron beams in magnetic fields is analyzed. Because of its extremely low mass and consequently high e/m ratio, a low energy electron is easily deflected in a magnetic field, thus providing a basis for very low field measurement. Calculations for a specific instrument design indicate that a low energy electron magnetometer (LEEM) can measure magnetic fields as low as 1000 nT. The anticipated performance of LEEM is compared with that of the existing high resolution magnetometers in selected applications. The fast response time of LEEM makes it especially attractive as a potential instrument for magnetic signature analysis in large engineering systems.

Singh, J. J.

The Magsat scalar magnetometer

The Magsat scalar magnetometer is derived from optical pumping magnetometers flown on the orbiting geophysical observatories. The basic sensor, a cross-coupled arrangement of absorption cells, photodiodes, and amplifiers, oscillates at the Larmor frequency of atomic moments precessing about the ambient field direction. The Larmor frequency output is accumulated digitally and stored for transfer to the spacecraft telemetry stream. In orbit the instrument has met its principal objective of calibrating the vector magnetometer and providing scalar field data.

Farthing, W. H.

The Magsat precision vector magnetometer

This paper examines the Magsat precision vector magnetometer which is designed to measure projections of the ambient field in three orthogonal directions. The system contains a highly stable and linear triaxial fluxgate magnetometer with a dynamic range of + or - 2000 nT (1 nT = 10 to the -9 weber per sq m). The magnetometer electronics, analog-to-digital converter, and digitally controlled current sources are implemented with redundant designs to avoid a loss of data in case of failures. Measurements are carried out with an accuracy of + or - 1 part in 64,000 in magnitude and 5 arcsec in orientation (1 arcsec = 0.00028 deg).

Acuna, M. H.

International solar polar mission: The vector helium magnetometer

The functional requirements for the vector helium magnetometer (VHM) on the Solar Polar spacecraft are presented. The VHM is one of the two magnetometers on board that will measure the vector magnetic field along the Earth to Jupiter transfer trajectory, as well as in the vicinity of Jupiter and along the solar polar orbit following the Jupiter encounter. The interconnection between these two magnetometers and their shared data processing unit is illustrated.

Source record

The UOSAT magnetometer experiment

The magnetometer aboard the University of Surrey satellite (UOSAT) and its associated electronics are described. The basic fluxgate magnetometer employed has a dynamic range of plus or minus 8000 nT with outputs digitized by a 12-bit successive approximation A-D converter having a resolution of plus or minus 2 nT. Noise in the 3-13 Hz bandwidth is less than 1 nT. A bias field generator extends the dynamic range to plus or minus 64,000 nT with quantization steps of 8000 nT. The magnetometer experiment is expected to provide information on the secular variation of the geomagnetic field, and the decay rate of the dipole term. Special emphasis will be placed on the acquisition of real time and memory data over the poles which can be correlated with that from Magsat.

Acuna, M. H.

A YBCO RF-SQUID magnetometer and its applications

An applicable RF-superconducting quantum interference detector (SQUID) magnetometer was made using a bulk sintered yttrium barium copper oxide (YBCO). The temperature range of the magnetometer is 77 to 300 K and the field range 0 to 0.1T. At 77 K, the equivalent flux noise of the SQUID is 5 x 10 to minus 4 power theta sub o/square root of Hz at the frequency range of 20 to 200 Hz. The experiments show that the SQUID noise at low-frequency end is mainly from 1/f noise. A coil test shows that the magnetic moment sensitivity delta m is 10 to the minus 6th power emu. The RF-SQUID is shielded in a YBCO cylinder with a shielding ability B sub in/B sub ex of about 10 to the minus 6th power when external dc magnetic field is about a few Oe. The magnetometer is successfully used in characterizing superconducting thin films.

Luwei, Zhou