Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oro-Nasal Mask Versus Two-Way Non-Rebreathing Valves for Maximal Aerobic Capacity Testing in Astronauts

Astronauts complete maximal aerobic capacity (VO2pk) testing as part of their annual fitness assessment (AFA) as well as several times once assigned to an International Space Station mission. Historically, the 2-Way T-Shape Non-Rebreathing valve with a mouthpiece and nose clip (“Mouthpiece”) has been used in these tests. The testing procedure was updated to use the oro-nasal mask (“Mask”) for the AFA starting in June 2017. Astronauts who used the mask during their AFA requested it be certified to be used for all mission associated tests. Considering the criticality of the data and the schedule constraints of astronauts, it is imperative that the requested hardware change provide data with equivalent reliability and repeatability as provided by the mouthpiece. PURPOSE: To assess the reliability and validity of mask vs. mouthpiece by comparing submaximal and VO2pkdata within subjects (approximately 1 year apart). METHODS: Each of 17 active astronauts completed a VO (sub 2pk) test with the mouthpiece (first) and the mask (second) for their AFA. The VO (sub 2pk) test was conducted on a cycle ergometer with a metabolic cart. The nominal protocol started with a 3-minute warm-up at 50 Watts (W) and increased 25W every minute until volitional fatigue (Light: 45W start; 15W increase). The VO (sub 2pk)s were compared between tests and the expected day-to-day variation (plus or minus 5 percent) was used as the threshold for determining agreement between tests. Submaximal values were plotted and evaluated visually for deviations between mask and mouthpiece. RESULTS: VO (sub 2pk) values were more than 5 percent different, despite similar test times, between mouthpiece and mask in 6 of 17 comparisons, 3 of which were higher with the mask (9.0 plus or minus 5.9 percent) while 3 were lower (minus10.8 plus or minus 2.0 percent) with the mask. The submaximal data did not indicate a leak in either apparatus during these tests. An Astronaut Strength & Conditioning Rehabilitation specialist confirmed that the measured differences in VO (sub 2pk) of these 6 astronauts was consistent with observed changes in exercise habits during the year that separated the two tests. CONCLUSION: After being presented with the results of this data mining effort the mask was accepted for use in all tests, excepting that, if a leak is detected without resolve, the test will be repeated (if schedule allows) and remaining tests will be completed with the mouthpiece.

Buxton, R.↗

Time-Varying Ice Sheet Mask: Implications on Ice-Sheet Mass Balance and Crustal Uplift

Mass-balance estimates of the polar ice sheets presently rely on static ice masks to identify the area under investigation. However, the vintage of available ice masks can differ by more than a decade and the resolution of the imagery used to delineate ice extent can differ by an order of magnitude, despite evidence of ongoing ice-sheet retreat. We show that using a fine resolution, time-varying ice mask significantly improves mass-balance estimates of the northwestern sector of the Greenland Ice Sheet and affects interpretation of local crustal uplift. Accounting for ice margin retreat using a time-varying ice mask between 2003–2015 results in 1.0–6.8% less ice-sheet mass loss relative to assuming one of several existing static ice masks. This indicates that mass-balance estimates that use a static ice mask will progressively overestimate mass loss where the ice sheet is predominantly retreating, meaning a negative bias on mass-balance. This trend is anticipated to be amplified in a future warming scenario unless updated ice masks are incorporated. For altimetry-derived mass-balance estimates, this ice-mask induced bias approaches the magnitude of the ice-sheet-wide uncertainty presently associated with spatiotemporal variability in modeled firn compaction. Further, at five GNET stations, the ice-mask-induced bias is equivalent to 5–15% of the modeled uplift due to elastic deformation. Given present and projected negative trends in Greenland Ice Sheet mass-balance and areal extent, we conclude that studies of its mass-balance should begin incorporating dynamic, periodically updated, fine-resolution ice masks. This methodological refinement will reduce bias in estimates of both ice-sheet mass-balance and crustal uplift.

Kristian K. Kjeldsen↗

ScAIN etch mask for highly selective etching

A fabrication process employing the use of ScAlN as an etch mask is disclosed. The ScAlN etch mask is chemically nonvolatile in fluorine-based etch chemistries and has a low sputter yield, resulting in greater etch mask selectivity and reduced surface roughness for silicon and other semiconductor materials. The ScAlN etch mask has an etch mask selectivity of greater than 200,000:1 relative to silicon compared to an etch mask selectivity of less than 40,000:1 for a prior art AlN etch mask relative to silicon. Further, due to reduced sputtering of the ScAlN etch mask, and thus reduced micromasking, the ScAlN etch mask yielded a surface roughness of 0.6 μm compared to a surface roughness of 2.8 μm for an AlN etch mask.

36 MATERIALS SCIENCE↗

Mask Free OLED Fabrication Process for Non-Tunable and Tunable White OLED Panels

In this program we demonstrated a method for mask free fabrication of OLEDs. Conventional OLEDs use at least 2 shadowmasks during the fabrication process to define the deposition pattern for the organic layers and for the cathode layer. Although effective, the use of masks requires mask handling and mask change equipment which increases the cost of the OLED deposition system. New sets of masks are required for every new product design, and the mask sets require frequent cleaning as organic material builds up on the masks over time and can be a source of particle defects resulting in yield loss. The method investigated in this program uses laser removal of organic material to pattern the organic layers and define a moisture impermeable seal region. This method is digital and can be applied to any new panel design, avoiding the costs of new masks sets and associated yield loss. In addition, we developed a platform technology for producing white color tunable or dim-to-warm white OLEDs and demonstrated patterning of tunable white OLEDs using the low-cost mask free fabrication process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

Focal Plane Mask↗

Spatial and Spatial Frequency Spreads of Masking: Measurements and A Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2, 4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 z 0 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, Joshua A.↗

Spatial and Spatial Frequency Spreads Of Masking: Measurements and a Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2,4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, J. A.↗

Improved Phase-Mask Fabrication of Fiber Bragg Gratings

An improved method of fabrication of Bragg gratings in optical fibers combines the best features of two prior methods: one that involves the use of a phase mask and one that involves interference between the two coherent laser beams. The improved method affords flexibility for tailoring Bragg wavelengths and bandwidths over wide ranges. A Bragg grating in an optical fiber is a periodic longitudinal variation in the index of refraction of the fiber core. The spatial period (Bragg wavelength) is chosen to obtain enhanced reflection of light of a given wavelength that would otherwise propagate relatively unimpeded along the core. Optionally, the spatial period of the index modulation can be made to vary gradually along the grating (such a grating is said to be chirped ) in order to obtain enhanced reflection across a wavelength band, the width of which is determined by the difference between the maximum and minimum Bragg wavelengths. In the present method as in both prior methods, a Bragg grating is formed by exposing an optical fiber to an ultraviolet-light interference field. The Bragg grating coincides with the pattern of exposure of the fiber core to ultraviolet light; in other words, the Bragg grating coincides with the interference fringes. Hence, the problem of tailoring the Bragg wavelength and bandwidth is largely one of tailoring the interference pattern and the placement of the fiber in the interference pattern. In the prior two-beam interferometric method, a single laser beam is split into two beams, which are subsequently recombined to produce an interference pattern at the location of an optical fiber. In the prior phase-mask method, a phase mask is used to diffract a laser beam mainly into two first orders, the interference between which creates the pattern to which an optical fiber is exposed. The prior two-beam interferometric method offers the advantage that the period of the interference pattern can be adjusted to produce gratings over a wide range of Bragg wavelengths, but offers the disadvantage that success depends on precise alignment and high mechanical stability. The prior phase-mask method affords the advantages of compactness of equipment and relative insensitivity to both misalignment and vibration, but does not afford adjustability of the Bragg wavelength. The present method affords both the flexibility of the prior two-beam interferometric method and the compactness and stability of the prior phase-mask method. In this method (see figure), a laser beam propagating along the x axis is normally incident on a phase mask that lies in the (y,z) plane. The phase of light propagating through the mask is modulated with a spatial periodicity, p, along the y axis chosen to diffract the laser light primarily to first order at the angle . (The zero-order laser light propagating along the x axis can be used for alignment and thereafter suppressed during exposure of the fiber.) The diffracted light passes through a concave cylindrical lens, which converts the flat diffracted wave fronts to cylindrical ones, as though the light emanated from a line source. Then two parallel flat mirrors recombine the diffracted beams to form an interference field equivalent to that of two coherent line sources at positions A and B (virtual sources). The interference pattern is a known function of the parameters of the apparatus and of position (x,y) in the interference field. Hence, the tilt, wavelength, and chirp of the Bragg grating can be chosen through suitable adjustments of the apparatus and/or of the position and orientation of the optical fiber. In particular, the Bragg wavelength can be adjusted by moving the fiber along the x axis, and the bandwidth can be modified over a wide range by changing the fiber tilt angle or by moving the phase mask and/or the fiber. Alignment is easy because the zero-order beam defines the x axis. The interference is relatively stable and insensitive to the mechanical vibration because of the gh symmetry and compactness of the apparatus, the fixed positions of the mirrors and lens, and the consequent fixed positions of the two virtual line sources, which are independent of the translations of the phase mask and the laser relative to the lens.

Grant, Joseph↗

Coronagraph Focal-Plane Phase Masks Based on Photonic Crystal Technology: Recent Progress and Observational Strategy

Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.

coronagraphy↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

Modeling high-efficiency extreme ultraviolet etched multilayer phase-shift masks

Achieving high-throughput extreme ultraviolet (EUV) patterning remains a major challenge due to low source power; phase-shift masks can help solve this challenge for dense features near the resolution limit by creating brighter images than traditional absorber masks when illuminated with the same source power. We explore applications of etched multilayer phase-shift masks for EUV lithography, both in the current-generation 0.33 NA and next-generation 0.55 NA systems. We derive analytic formulas for the thin-mask throughput gains, which are 2.42× for lines and spaces and 5.86× for contacts compared with an absorber mask with dipole and quadrupole illumination, respectively. Using rigorous finite-difference time-domain simulations, we quantify variations in these gains by pitch and orientation, finding 87% to 113% of the thin-mask value for lines and spaces and a 91% to 99% for contacts. We introduce an edge placement error metric, which accounts for CD errors, relative feature motion, and telecentricity errors, and use this metric both to optimize mask designs for individual features and to explore which features can be printed on the same mask. Furthermore, we find that although partial coherence shrinks the process window, at an achievable sigma of 0.2 we obtain a depth of focus of 340 nm and an exposure latitude of 39.2%, suggesting that partial coherence will not limit the feasibility of this technology. Finally, we show that many problems such as sensitivity to etch uniformity can be greatly mitigated using a central obscuration in the imaging pupil.

42 ENGINEERING↗

SU-E-T-541: Bolus Effect of Thermoplastic Masks in IMRT and VMAT Head and Neck Treatments

Purpose: To quantitatively evaluate the bolus effect of thermoplalstic mask on patient skin dose during multi-field IMRT and VMAT treatment. Methods: The clinically approved target contours for five head and neck patients were deformably registered to an anthropomorphic Rando phantom. Two plans: Multifield IMRT plan with 7-9 beams and VMAT plan with 2-4 arcs were created for each patient following same dose constraints. 3mm skin was excluded from PTVs but not constrained during optimization. The prescription dose was 200-220 cGy/fraction. A thermoplastic head and shoulder mask was customized for the Rando phantom. Each plan was delivered to the phantom twice with and without mask. During each delivery, two rectangular strips of EBT3 films (1cm x 6.8cm) were placed across the anterior upper and lower neck near PTVs to measure the surface dose. For consistency films were positioned at same locations for same patient. A total of 8 film strips were obtained for each patient. Film dose was calibrated in the range of 0-400cGy on the day of plan delivery. For dose comparison 3 regions of interests (ROIs) of 1×1 cm{sup 2} were selected at left, right and middle part of each film, resulting in 6 point doses at each plan delivery. Results: The films without mask show relatively uniform dose distribution while those with mask clearly show mesh pattern of mask, usually indicating an increase in skin dose. On average the increase in skin dose over all ROIs with mask was 31.9%(±14.8%) with a range of 11.4%- 58.4%. There is no statistically significant difference (p=0.44) between skin dose increase in VMAT (30.8%±15.3%) and IMRT delivery (33.0%±14.9%). Conclusion: Thermoplastic immobilization masks increase surface dose for HN patient by around 30%. The magnitude is comparable between multi-field IMRT and VMAT. Radiochromic EBT3 film serves as an effective tool to quantify bolus effect.

60 APPLIED LIFE SCIENCES↗

SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

Masking of a High-Reflectivity Sphere by a Layer with a Random Quasi-Zero Refractive Index

The method of masking of a large-radius sphere made of an arbitrary material by a masking coating with a random quasi-zero refractive index is substantiated theoretically and experimentally. In this method of masking, the sphere is first coated with a mirror layer (e.g., high-reflectivity silver) and then with a masking layer with a thickness much smaller than the radius of the sphere. The fraction of the external radiation intensity bending around the sphere at the points of observation near the surface of the sphere and the extinction cross section of the sphere with the masking coating for points of observation far away from the sphere are calculated. It is shown that extinction cross section Q of the sphere with a masking coating is much smaller than 2D, where D is the geometrical cross section of the sphere; this corresponds to the masking effect for the sphere in the wavelength range of at least 450–1200 nm in the transparency region of the masking coating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bubble masks for time-encoded imaging of fast neutrons.

Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is induced typically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gaps bubbles propagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

Brubaker, Erik↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding

Advanced formation flying occulter designs utilize a large occulter mask flying in formation with an imaging telescope to block and null starlight to allow imaging of faint planets in exosolar systems. A paper describes the utilization of subscale reflective occultation masks to evaluate formation flying occulter designs. The use of a reflective mask allows mounting of the occulter by conventional means and simplifies the test configuration. The innovation alters the test set-up to allow mounting of the mask using standard techniques to eliminate the problems associated with a standard configuration. The modified configuration uses a reflective set-up whereby the star simulator reflects off of a reflective occulting mask and into an evaluation telescope. Since the mask is sized to capture all rays required for the imaging test, it can be mounted directly to a supporting fixture without interfering with the beam. Functionally, the reflective occultation mask reflects light from the star simulator instead of transmitting it, with a highly absorptive carbon nanotube layer simulating the occulter blocking mask. A subscale telescope images the star source and companion dim source that represents a planet. The primary advantage of this is that the occulter can be mounted conventionally instead of using diffractive wires or magnetic levitation.

Hagopian, John↗