Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

UV-POSIT: Web-Based Tools for Rapid and Facile Structural Interpretation of Ultraviolet Photodissociation (UVPD) Mass Spectra

UV-POSIT (Ultraviolet Photodissociation Online Structure Interrogation Tools) is a suite of web-based tools designed to facilitate the rapid interpretation of data from native mass spectrometry experiments making use of 193 nm ultraviolet photodissociation (UVPD). The suite includes four separate utilities which assist in the calculation of fragment ion abundances as a function of backbone cleavage sites and sequence position; the localization of charge sites in intact proteins; the calculation of hydrogen elimination propensity for a-type fragment ions; and mass-offset searching of UVPD spectra to identify unknown modifications and assess false positive fragment identifications. UV-POSIT is implemented as a Python/Flask web application hosted at http://uv-posit.cm.utexas.edu . UV-POSIT is available under the MIT license, and the source code is available at https://github.com/jarosenb/UV-POSIT . .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIMILE enables alignment of tandem mass spectra with statistical significance

Abstract Interrelating small molecules according to their aligned fragmentation spectra is central to tandem mass spectrometry-based untargeted metabolomics. Current alignment algorithms do not provide statistical significance and compounds that have multiple delocalized structural differences and therefore often fail to have their fragment ions aligned. Here we align fragmentation spectra with both statistical significance and allowance for multiple chemical differences using Significant Interrelation of MS/MS Ions via Laplacian Embedding (SIMILE). SIMILE yields spectral alignment inferred structural connections in molecular networks that are not found with cosine-based scoring algorithms. In addition, it is now possible to rank spectral alignments based on p-values in the exploration of structural relationships between compounds and enhance the chemical connectivity that can be obtained with molecular networking.

59 BASIC BIOLOGICAL SCIENCES↗

Mass spectra of the particle-antiparticle system with a Dirac oscillator interaction

The present view about the structure of mesons is that they are a quark-antiquark system. The mass spectrum corresponding to this system should, in principle, be given by chromodynamics, but this turns out to be a complex affair. Thus it is of some interest to consider relativistic systems of particle-antiparticle, with a simple type of interaction, which could give some insight on the spectra we can expect for mesons. This analysis is carried out when the interaction is of the Dirac oscillator type. It is shown that the Dirac equation of the antiparticle can be obtained from that of the particle by just changing the frequency omega into -omega. Following a procedure suggested by Barut, the equation for the particle-antiparticle system is derived and it is solved by a perturbation procedure. Thus, explicit expressions for the square of the mass spectra are obtained and its implications in the meson case is discussed.

Moshinsky, M.↗

SpectraCodec: A Hilbert curve-based method for encoding metadata in mass spectra for machine learning applications (SpectraCodec) v1

Machine learning approaches to mass spectrometry (MS) data analysis require structured metadata for optimal performance. However, current MS file formats necessitate external metadata sources, creating integration challenges that impede analytical workflows. Here, we present a novel approach for encoding metadata directly within mzML files using one-hot encoding of ASCII characters mapped via Hilbert space-filling curves. This strategy embeds metadata in the first spectrum's m/z-intensity space, ensuring persistence with the primary data, eliminating the need for external metadata files, and maintaining compatibility with existing MS software. We demonstrate that the Hilbert curve mapping efficiently utilizes the two-dimensional spectral space while maintaining robust data recovery. This method offers a practical solution for machine learning applications in mass spectrometry by ensuring metadata and spectral data remain unified through all stages of analysis.

Bowen, Benjamin [Lawrence Berkeley National Labora↗

Pyrolysis_Molecular_Beam_Mass_Spectra_for_Standard_Biomass_Samples_and_Natural_Variants_of_Switchgrass_Grown_Under_Different_Conditions

This data consists of total ion chromatogram (TIC) normalized Pyrolysis-Molecular Beam Mass Spectrometry (py-MBMS) spectra collected to predict lignin content and lignin monomeric ratios for “Variation in Biomass Yield and Cell Wall Composition in Switchgrass Natural Variants Under Two Nitrogen Regimes” (https://doi.org/10.1007/s12155-025-10838-8).

09 BIOMASS FUELS↗

Analysis of steranes and triterpanes in geolipid extracts by automatic classification of mass spectra

A computer method is described for the automatic classification of triterpanes and steranes into gross structural type from their mass spectral characteristics. The method has been applied to the spectra obtained by gas-chromatographic/mass-spectroscopic analysis of two mixtures of standards and of hydrocarbon fractions isolated from Green River and Messel oil shales. Almost all of the steranes and triterpanes identified previously in both shales were classified, in addition to a number of new components. The results indicate that classification of such alkanes is possible with a laboratory computer system. The method has application to diagenesis and maturation studies as well as to oil/oil and oil/source rock correlations in which rapid screening of large numbers of samples is required.

Wardroper, A. M. K.↗

Venus' Mass Spectra Show Signs of Disequilibria in the Middle Clouds

We present a re‐examination of mass spectral data obtained from the Pioneer Venus Large Probe Neutral Mass Spectrometer. Our interpretations of differing trace chemical species are suggestive of redox disequilibria in Venus' middle clouds. Assignments to the data (at 51.3 km) include phosphine, hydrogen sulfide, nitrous acid, nitric acid, carbon monoxide, hydrochloric acid, hydrogen cyanide, ethane, and potentially ammonia, chlorous acid, and several tentative PxOy species. All parent ions were predicated upon assignment of corresponding fragmentation products, isotopologues, and atomic species. The data reveal parent ions at varying oxidation states, implying the presence of reducing power in the clouds, and illuminating the potential for chemistries yet to be discovered. When considering the hypothetical habitability of Venus' clouds, the assignments reveal a potential signature of anaerobic phosphorus metabolism (phosphine), an electron donor for anoxygenic photosynthesis (nitrite), and major constituents of the nitrogen cycle (nitrate, nitrite, ammonia, and N2).

disequilibria↗

Predicting Catalytic Pyrolysis Aromatic Selectivity from Pyrolysis Vapor Composition Using Mass Spectra Coupled with Statistical Analysis

The behavior of fast pyrolysis (FP) and catalytic FP (CFP) of 20 renewable feedstocks was studied in a microscale reactor with molecular beam mass spectral analysis of products generated. A partial least-squares (PLS) model was constructed based on the FP vapor spectra that predicts the aromatic selectivity when upgrading over a ZSM-5 catalyst. Additionally, principal component analysis of both FP and CFP spectra was performed for comprehensive spectral analysis. This work highlighted the value of vapor-phase mass spectral screening to predict the subsequent feedstock performance and demonstrated that the quantity of coke deposited on the catalyst is not a reliable measure of catalyst deactivation when the feedstock type is varied.

09 BIOMASS FUELS↗

Mass spectra of neutral particles released during electrical breakdown of thin polymer films

A special type of time-of-flight mass spectrometer triggered from the breakdown event was developed to study the composition of the neutral particle flux released during the electrical breakdown of polymer films problem. Charge is fed onto a metal-backed polymer surface by a movable smooth platinum contact. A slowly increasing potential from a high-impedance source is applied to the contact until breakdown occurs. The breakdown characteristics is made similar to those produced by an electron beam charging system operating at similar potentials. The apparatus showed that intense instantaneous fluxes of neutral particles are released from the sites of breakdown events. For Teflon FEP films of 50 and 75 microns thickness the material released consists almost entirely of fluorocarbon fragments, some of them having masses greater than 350 atomic mass units amu, while the material released from a 50 micron Kapton film consists mainly of light hydrocarbons with masses at or below 44 amu, with additional carbon monoxide and carbon dioxide. The apparatus is modified to allow electron beam charging of the samples.

Kendall, B. R. F.↗

Mass spectra stimulated by O+ and Ar+ interacting with a surface.

Beams of O(+) and Ar(+) in the energy range from 100 to 300 eV were directed into an aperture in one face of a copper box. The mass spectrum from a similar aperture in an adjacent face was observed with the aid of a commercial RF quadrupole spectrometer. On the basis of the results obtained it is reported that O(+) beams at about 200 eV may be essentially lost after a few collisions with a surface, in agreement with similar conclusions about atomic oxygen at thermal energies.

Siegel, M. W.↗

An application of artificial intelligence to the interpretation of mass spectra.

Description of the DENDRAL (Dendritic Algorithm) project, the objectives of which were to base the computer program on an alogorithm that generates an exhaustive, nonredundant list of all the structural isomers of a given chemical composition, and to devise a computer program that would perform an organic structure determination, given a molecular formula and a mass spectrum. This program is called 'Heuristic DENDRAL' and it operates by using the known structure/spectrum correlations to constrain the DENDRAL isomer generator to produce a single isomer for that composition. The collaboration of chemists and computer scientists has produced a tool of some practical utility from the chemical viewpoint, and an interesting program from the viewpoint of artificial intelligence.

Buchanan, B. G.↗

Search for resonance in inclusive and b-tagged dijet mass spectra in proton-proton collision at $\sqrt{s}$ = 13 TeV and constraints on dark matter and other models

Two analyses searching for new heavy resonances and interpreting the result with dark matter are presented in this dissertation. The first analysis searches for resonances decaying into dijet final states using the proton-proton collision data at center mass of $\sqrt{s}=13$ TeV with the CMS detector at Large Hadron Collider in2016, corresponding to a total integrated luminosity of 36 fb -1 . No significant evidence for the production of new particles is observed. A simplified model of interactions between quarks and dark matter is used to interpret the result. The second analysis searches for resonances decaying into dijet final states using the proton-proton collision data at center mass of $\sqrt{s}=13$ TeV with the CMS detector at Large Hadron Collider in 2016, 2017, and 2018, corresponding to a total integrated luminosity of 137.5 fb -1 . A b-tagger named DeepJet is used to examine the events with jets containing B hadrons. No evidence of new heavy resonances is observed, as well. The 95% confidence level cross-section upper limit is set on excited b-quark b* and Coloron models. Limits are also set on a simplified model of interactions between b-quarks and dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass spectra of heavy ions near comet Halley

The heavy-ion analyzer, RPA2-PICCA, aboard the Giotto spacecraft, detected the first cometary ions at a distance of about 1.05 million km from the nucleus of comet Halley. In the inner coma the major ions identified are associated with the H2O, CO and CO2 groups. Ions of larger atomic mass unit are also present, corresponding possibly to various hydrocarbons, heavy metals of the iron-group or to sulphur compounds.

Korth, A.↗