NIMBUS INTEGRATION AND TEST PROGRAM PLAN
Nimbus satellite - integration and test program plan
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nimbus satellite - integration and test program plan
The DAHCS (pronounced “Dax”) MC is a 7-year, $\$$45 million research portfolio within Sandia’s Laboratory Directed Research and Development program. The DAHCS MC arose in response to a great need: to ensure that the use of digital technologies does not weaken our nation’s high consequence systems. Digital technologies offer many benefits in speed, cost, and flexibility, and we seek to reap those benefits without introducing new system failures. However, digital technologies cannot be evaluated the same way as analog technologies. Initiatives across the nation highlight the capability gap that prevents efficient, effective digital assurance. The Challenge Today’s digital assurance tools, techniques, and methods are inadequate to confidently characterize, assess, and manage digital risk; they are ad hoc, slow, costly, and rarely scalable to increasingly complex digital technologies. The rapidly evolving cyber threat landscape exacerbates this problem because digital assurance now must secure against digital risks now and in the future, including those introduced by rapidly evolving technologies, adversaries, and systems.
The Nevada Test Site (NTS) began operating Material Control and Accountability (MC&A) under the Safeguards First Principle Initiative (SFPI), a risk-based and cost-effective program, in December 2006. The NTS SFPI Comprehensive Assessment of Safeguards Systems (COMPASS) Model is made up of specific elements (MC&A plan, graded safeguards, accounting systems, measurements, containment, surveillance, physical inventories, shipper/receiver differences, assessments/performance tests) and various sub-elements, which are each assigned effectiveness and contribution factors that when weighted and rated reflect the health of the MC&A program. The MC&A Cost Model, using an Excel workbook, calculates budget and/or actual costs using these same elements/sub-elements resulting in total costs and effectiveness costs per element/sub-element. These calculations allow management to identify how costs are distributed for each element/sub-element. The Cost Model, as part of the SFPI program review process, enables management to determine if spending is appropriate for each element/sub-element.
Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for table attenuation, obese patient geometry, and differences between the anthropomorphic phantom and MC mathematical phantom.
Uncertainty complicates the development optimization of oil and gas exploration and production projects, but methods have been devised to analyze uncertainty and its impact on optimal decision-making. This paper compares two methods for development optimization and uncertainty analysis: Monte Carlo (MC) simulation and stochastic programming. Two example problems for a gas field development and an oilfield development are solved and discussed to elaborate the advantages and disadvantages of each method. Development optimization involves decisions regarding the configuration of initial capital investment and subsequent operational decisions. Uncertainty analysis involves the quantification of the impact of uncertain parameters on the optimum design concept. The gas field development problem is designed to highlight the differences in the implementation of the two methods and to show that both methods yield the exact same optimum design. The results show that both MC optimization and stochastic programming provide unique benefits, and that the choice of method depends on the goal of the analysis. While the MC method generates more useful information, along with the optimum design configuration, the stochastic programming method is more computationally efficient in determining the optimal solution. Reservoirs comprise multiple compartments and layers with multiphase flow of oil, water, and gas. We present a workflow for development optimization under uncertainty for these reservoirs, and solve an example on the design optimization of a multicompartment, multilayer oilfield development.
The Nuclear Material Management & Storage (NMM&S) program at the Nevada National Security Site (NNSS) have the responsibility for the life-cycle management of accountable nuclear materials (NM) in accordance with Department of Energy (DOE) Order 410.2, “Management of Nuclear Materials” and for ensuring workers are protected from exposure to nuclear materials stored outside of an authorized shipping package under DOE Manual 441.1-1. To ensure these responsibilities were addressed in an effective, concise, and secure manner the development of NMM&S databases was undertaken. Using the existing database server structure and data acquired from the official Material Control & Accountability (MC&A) accounting program development of two separate applications, one for O 410.2 inventory requirements (NMIA) and one for M441, were begun in September 2015. The databases were deployed onto the production server in January 2017. The inventory database allows for entering NM characterization data, production of O 410.2 reports, and the ability to retain history files. The M441 database screens NM to determine if it is subject to the manual's requirements, ability to pull in unclassified RadCon materials, and provide reports as required by NMM&S, NM owners, and headquarters programs. These two databases provide NMM&S the ability to better ensure safe and secure packaging, storage, stabilization, consolidation, or disposition of NM and achieve life-cycle management goals.
Tamper Indicating Device (TID): Initial Training, course #50112, covers Los Alamos National Laboratory (LANL) Material Control & Accountability (MC&A) TID Program procedures for the application and removal of TIDs. LANL’s policy is to comply with Department of Energy (DOE) requirements for the use of TIDs consistent with the graded safeguards described in DOE Manual DOE O 474.2, Nuclear Material Control and Accountability. When you have completed this course, you will: recognize standard practices and procedures of the LANL TID Program; have hands-on experience in the application and removal of LANL TIDs, and; verify the application and removal of LANL TIDs.
Pyroprocessing flowsheets have been designed that have efficient actinide recovery, meet nonproliferation objectives, minimize waste, and are commercially viable. The analysis of safeguards of pyrochemical recycle systems for the treatment of used fast reactor metal fuel can be greatly enhanced with the employment of robust dynamic models. Electrochemical process modeling also contributes to broader objectives of the MPACT program by supporting MC&A, options screening, and safeguards analysis and can inform development of sensor systems for a used fuel recycle facility. Modeling can also provide a method for defining metrics and requirements on advanced analysis techniques.
N/A
The purpose of this report is to provide molten salt reactor (MSR) developers and future US Nuclear Regulatory Commission (NRC) license applicants with recommendations for developing an effective and practical material control and accounting (MC&A) plan, focused primarily on MSR designs that use circulating liquid fuel. Because of the breadth of MSR designs, there is no single, generic, detailed MC&A plan that will work for every design. The wide variation of fresh fuel salts, the method and frequency of loading fresh fuel, the reactor system design components (e.g., tanks, filtration systems, chemical processing streams), and waste streams will determine the specific measurement locations and instrumentation that can best meet MC&A objectives throughout an MSR facility. Additionally, MSR designs are rapidly evolving, and new design features and deployment scenarios that will affect MC&A are being explored and pursued. This report defines a generic MC&A approach that was developed for terrestrial (as opposed to maritime) deployments to meet the intent of NRC domestic safeguards and MC&A. MSR license applicants should consider nuclear safeguards (both domestic and international) and security throughout the design, as early as the preconceptual design phase. MC&A of special nuclear material (SNM) is an aspect of the NRC’s domestic safeguards program, alongside physical protection. Because liquid-fueled MSRs are reactors with SNM in nondiscrete (or item) form, it is likely that the NRC may require liquid-fueled MSR license applicants to submit a formal MC&A plan as a part of their license application. Currently, the NRC licensing protocol presents a challenge because the NRC MC&A regulations have not been updated to accommodate advanced reactors, including types of MSRs. Because no liquid-fueled MSR has been licensed for operation at the time of this report, no template or precedence for a successfully licensed MSR MC&A plan exists. However, the MSR license applicant can take advantage of the NRC’s published commitments to performance-based regulations. The authors recommend that the license applicant, or MSR designers, develop an MC&A plan throughout the design lifecycle and plan to submit a detailed MC&A program description, or MC&A plan, to the NRC as a part of a license application. No MC&A plan template or guidance exists that is specific to liquid-fueled MSRs. The authors recommend that license applicants discuss the topic of MC&A during preapplication engagement. Because of the uniqueness of MC&A for liquid fueled MSRs, the authors recommend that liquid fueled MSR developers engage with the NRC on the topic of MC&A in the early phases of its design development and follow up any time there are significant modifications in design plans that would affect MC&A. For example, topics like modifications in fuel handling processes, changes in uranium enrichment, or additional chemical processing streams added to the design could be discussed with the NRC specifically on the topic of MC&A.
The George Kuzmycz Training Center (GKTC) for Physical Protection, Control and Accounting of Nuclear Materials was established in 1998 at the Kyiv Institute of Nuclear Research of the Ukrainian Academy of Sciences through the collaborative efforts of the United States and Ukraine. Later the European Commission (EC) joined the US in assisting with the Material Control and Accounting (MC&A) part of the GKTC training program. The Government of Ukraine designated the GKTC as the National Center responsible for providing training and methodological support for nuclear facilities and nuclear specialists in the Material Protection, Control and Accounting (MPC&A) area. To increase the efficiency of the State MC&A system an essential number of new regulations, norms and rules have been developed; some of them mandate regular and more intensive training of MC&A specialists in the industry - from those working at the Nuclear Regulatory Authority of Ukraine to the personnel of nuclear facilities. To meet such regulations GKTC plans to develop next year a number of training courses under the EC contract; such courses will reflect both the specifics of Ukrainian nuclear facilities and the level of expertise of the facilities’ personnel. The NDA training laboratory, established in 2003 with US DOE financial support and technical and methodological assistance, considerably expanded the GKTC’s training capabilities for MC&A programs. Next year that lab will be supplemented with a new NM Surveillance and Containment laboratory as current plans call for under the EC contract. The US DOE is also providing funding to support that project. Under the EC contract the laboratory will be equipped with state-of-the-art, advanced surveillance and containment equipment which will strengthen and expand even further the GKTC’s training capabilities and potential. This will allow GKTC to train Ukrainian nuclear industry specialists in practically all MC&A topics. Furthermore, GKTC is planning to offer already this year and to continue offering in the future, on a regular basis, the courses that have already been developed, while continuing to develop new ones. This paper briefly describes the work done to upgrade the Ukrainian MC&A system, both at the State and at the facilities’ levels, as well as the results of efforts to develop the National System for training MC&A personnel at the GKTC. It also describes problems encountered and their solution; it includes comments, suggestions and recommendations for future activities to promote and improve the nuclear material management culture in Ukraine.
As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).
Purpose Uncertainty in the Relative Biological Effectiveness (RBE) of heavy charged particles compared to photons remains one of the major uncertainties in particle therapy. As RBEs depend strongly on clinical variables such as tissue type, dose, and radiation quality, more accurate individualised models are needed to fully optimise treatments. MethodsWe have developed a model of DNA damage and repair following X-ray irradiation in a number of settings, incorporating mechanistic descriptions of DNA repair pathways, geometric effects on DNA repair, cell cycle effects and cell death. Our model has previously been shown to accurately predict a range of biological endpoints including chromosome aberrations, mutations, and cell death. This model was combined with nanodosimetric models of individual ion tracks to calculate the additional probability of lethal damage forming within a single track. These lethal damage probabilities can be used to predict survival and RBE for cells irradiated with ions of different Linear Energy Transfer (LET). ResultsBy combining the X-ray response model with nanodosimetry information, predictions of RBE can be made without cell-line specific fitting. The model’s RBE predictions were found to agree well with empirical proton RBE models (Mean absolute difference between models of 1.9% and 1.8% for cells with α/β ratios of 9 and 1.4, respectively, for LETs between 0 and 15 keV/µm). The model also accurately recovers the impact of high-LET carbon ion exposures, showing both the reduced efficacy of ions at extremely high LET, as well as the impact of defects in non-homologous end joining on RBE values in Chinese Hamster Ovary cells.ConclusionOur model is predicts RBE without the inclusion of empirical LET fitting parameters for a range of experimental conditions. This approach has the potential to deliver improved personalisation of particle therapy, with future developments allowing for the calculation of individualised RBEs. SJM is supported by a Marie Curie International Outgoing Fellowship from the European Commission’s FP7 program (EC FP7 MC-IOF-623630)
The Apollo 16 electrophoresis experiment was analyzed, demonstrating that the separation of the two different-size monodisperse latexes did indeed take place, but that the separation was obscured by the pronounced electroosmotic flow of the liquid medium. The results of this experiment, however, were dramatic since it is impossible to carry out a similar separation on earth. It can be stated unequivocally from this experiment that any electrophoretic separation will be enhanced under microgravity conditions. The only question is the degree of this enhancement, which can be expected to vary from one experimental technique to another. The low-electroosmotic-mobility coating (Z6040-MC) developed under this program was found to be suitable for a free-fluid electrophoretic separation such as the experiment designed for the ASTP flight. The problem with this coating, however, is that its permanency is limited because of the slow desorption of the methylcellulose from the coated surface.
In the past, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site has been performed by the Radiological Health Instrumentation Department. Calibration and performance tests on the PM-700 personnel portal monitor were performed but there was no test program for the VM-250 vehicle portal monitor because it had never been put into service. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no program in place to test them quarterly. In April of 2007, the Material Control and Accountability (MC&A) Manager at the time decided that the program needed to be strengthened and MC&A took over performance testing of all SNM portal monitoring equipment. This paper will discuss the following activities associated with creating a performance testing program: changing the culture, learning the systems, writing procedures, troubleshooting/repairing, validating the process, control of equipment, acquisition of new systems, and running the program.
This report summarizes the key activities of the Material Protection, Accounting, and Control Technologies (MPACT) program’s safeguards training work package for FY25. The work focused on two main areas: domestic safeguards training and the development of new technologies for nuclear material accounting and control (NMAC). A key development during this FY was the delivery of NMAC statistics for US Nuclear Regulatory Commission requirements refresher course. The course objective was to assist industry in meeting the MC&A program requirements for fuel cycle facilities; this training focused on front-end bulk fuel cycle processes. At the same time, a report was prepared on the research output of an effort that focused on the benefits of commercial fuel debundling for NMAC and waste management. The MPACT team evaluated various technologies and proposed a fuel debundling detector that integrates gamma spectroscopy and neutron detection as the most practical solution. The scope of activities under this work package for FY26 focuses on developing a fundamental nuclear material control plan, also known as MC&A plan, for tristructural isotropic (TRISO) fuel fabrication facilities. This plan will address the various NMAC requirements for facilities that handle Category II.
This report covers the application of the TRi-structural ISOtropic (TRISO) fuel fabrication facility material control & accounting (MC&A) modeling capability developed by Sandia National Laboratories (SNL) under the U.S. Department of Energy (DOE) Materials Protection, Accounting, and Control Technologies (MPACT) program to support the development of MC&A approaches for the Low Enriched Fuel Fabrication Facility (LEFFF) at Los Alamos National Laboratory (LANL).