Search NASA⌕ Search

SEARCH · Search NASA

Results for “MC-ICP-MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Characterizing the Uncertainty of Measurement of Traceable Isotope Ratios with Bayesian Statistical Techniques

Analytical techniques such as multicollector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) are routinely employed at SRNL, other National Laboratories, and in academia to determine the precise isotopic composition of diverse natural and anthropogenic samples (e.g., rocks and nuclear materials). Quantifying and reporting uncertainty in such analyses, while regularly performed, have a rigorous statistical foundation. The Guide to the Expression of Uncertainty in Measurement 4 (GUM) outlines conventional techniques used to assess such uncertainty. As the accessibility and speed of statistical computing increase, there is a need to modernize conventional techniques. For example, Supplement 1 to the 3rd to the GUM suggests the use of approximation methods as an updated approach to the GUM.

McLarty, Ellis C.↗

Iron-Isotopic Fractionation Studies Using Multiple Collector Inductively Coupled Plasma Mass Spectrometry

The importance of Fe biogeochemistry has stimulated interest in Fe isotope fractionation. Recent studies using thermal ionization mass spectrometry (TIMS) and a "double spike" demonstrate the existence of biogenic Fe isotope effects. Here, we assess the utility of multiple-collector inductively-coupled plasma mass spectrometry(MC-ICP-MS) with a desolvating sample introduction system for Fe isotope studies, and present data on Fe biominerals produced by a thermophilic bacterium. Additional information is contained in the original extended abstract.

Anbar, A. D.↗

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

C136A and C138A Report of Analysis

In this work the isotopic ratios and weight percentages of 238 Pu, 239 Pu, 240 Pu, 241 Pu and 242 Pu were determined using Isotope Dilution Mass Spectrometry. Two samples of C136A and C138A were sent to the Analytical Research laboratories by the National Nuclear Security Administration Nuclear Reference Material Program. The four samples were dissolved in concentrated hydrochloric acid. From the parent solutions, eight aliquots were taken, diluted, spiked with 244 Pu and submitted to separations. After the samples were separated, they were analyzed using Multicollector Inductively Coupled Plasma Mass Spectrometry. Along with the samples, two C126A Quality Control Samples were analyzed each day. Mass bias standards were also analyzed at the beginning, during and at the end of the analysis. GUM Workbench Pro software Version 2.4.1.406 was used to calculate the isotopic ratios relative to 239 Pu, and total Pu mass and the correlated expanded uncertainties.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗