Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Using CUBIT to Create Unstructured Mesh Models for MCNP Simulations

The Monte Carlo N-Particle (MCNP) transport code version 6 (also known as MCNP6) has the capability for tracking particles on unstructured mesh (UM) geometry models embedded into constructive solid geometry (CSG) cells. This feature has been developed for performing calculations of complex geometry models because creating CSG models is a time-consuming and error-prone process as the complexities of geometries increase. An MCNP UM calculation requires UM geometry input files. The UM capability was originally designed to work with UM models created with the Abaqus/CAE software and ASCII input files that it generates. The Abaqus-formatted input files needed for MCNP UM calculations must have the correct Abaqus syntax and meet the additional MCNP requirements. Several software packages can generate a UM model formatted as an Abaqus input file. Cubit, the Sandia National Laboratory automated mesh generation toolkit, can generate a UM model formatted as an Abaqus input file. However, the Abaqus input files created by Cubit cannot be used for MCNP simulations. A Python script has been developed to convert an Abaqus file created by Cubit to an Abaqus file that the MCNP code can process. This report describes the process of using Cubit to create UM models for MCNP calculations.

97 MATHEMATICS AND COMPUTING↗

Development of a Scale Model for High Flux Isotope Reactor Cycle 400

The development of a comprehensive SCALE computational model for the High Flux Isotope Reactor (HFIR) is documented and discussed in this report. The SCALE model has equivalent features and functionality as the reference MCNP model for Cycle 400 that has been used extensively for HFIR safety analyses and for HFIR experiment design and analyses. Numerical comparisons of the SCALE and MCNP models for the multiplication constant, power density distribution in the fuel, and neutron fluxes at several locations in HFIR indicate excellent agreement between the results predicted with the two models. The SCALE HFIR model is presented in sufficient detail to provide the users of the model with a tool that can be easily customized for various safety analysis or experiment design requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of the Pulsed Radiation Environment in FREC-II at the ACRR

Ongoing tests at the Annular Core Research Reactor (ACRR) at Sandia National Laboratories aim to measure temperature and strain in materials exposed to a transient neutron-photon environment. Radiation transport and finite element analysis codes are used to predict the thermal-structural response of test articles exposed in the reactor. Strain and temperature sensors fielded on test articles provide validation data for finite element models, while active and passive radiation dosimetry provides data for MCNP models. The ACRR is able to provide pulse energies of 40 - 300 MJ per pulse with pulse times of 7 - 100 milliseconds. The pulse power is higher than many of the other research reactors due to its unique high heat capacity UO{sub 2}-BeO fuel in the central reactor. Additionally, the Fuel Ringed External Cavity (FREC-II) contains U-ZrH fuel. Future tests at the ACRR plan to field test assemblies in the Fuel Ringed External Cavity (FREC-II) and expose the test articles to the transient anisotropic radiation field experienced in the cavity. The FREC-II is coupled with the ACRR core and is used to test larger specimens, and the radiation environment can be shaped/modified to the needs of the experiment. The FREC-II was designed to provide an irradiation cavity with a strong flux gradient favoring the central cavity side. Neutron fluence also varies by height in the cavity, with a peak level slightly below the fuel rod vertical centerline. Tests were conducted in 2014 to measure the thermal-structural response of test articles exposed in the central cavity. Those tests in the central cavity fielded Nickel activation foils to record the neutron fluence at various locations around the test assembly. Foil data was later used to highlight uncertainties between thermo-structural response models and the measured temperature and strain. Studies performed in 2015 exposed large arrays of activation foils and thermo-luminescent dosimeters (TLD) in the FREC-II cavity in order to map out the neutron and photon spectrum at many locations. This type of passive measurement was shown to be too simple for performing thermo-structural simulations of a test article in response to multiple pulsed-reactor exposures. The Depleted Uranium Strain and Temperature - Enhanced Response (DUSTER-II) experiments will expose test assemblies to reactor pulses in the FREC-II cavity. To prepare for these experiments, the MCNP model will be compared with June 2016 experimental results from the pulses with the FREC-II coupled with the ACRR. These comparisons will provide an accurate model to be implemented in further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling and Simulations for the High Flux Isotope Reactor Cycle 400

A concerted effort over the past few years has been focused on enhancing the core model for the High Flux Isotope Reactor (HFIR), as part of a comprehensive study for HFIR conversion from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuel. At this time, the core model used to perform analyses in support of HFIR operation is an MCNP model for the beginning of Cycle 400, which was documented in detail in a 2005 technical report. A HFIR core depletion model that is based on current state-of-the-art methods and nuclear data was needed to serve as reference for the design of an LEU fuel for HFIR. The recent enhancements in modeling and simulations for HFIR that are discussed in the present report include: (1) revision of the 2005 MCNP model for the beginning of Cycle 400 to improve the modeling data and assumptions as necessary based on appropriate primary reference sources HFIR drawings and reports; (2) improvement of the fuel region model, including an explicit representation for the involute fuel plate geometry that is characteristic to HFIR fuel; and (3) revision of the Monte Carlo-based depletion model for HFIR in use since 2009 but never documented in detail, with the development of a new depletion model for the HFIR explicit fuel plate representation. The new HFIR models for Cycle 400 are used to determine various metrics of relevance to reactor performance and safety assessments. The calculated metrics are compared, where possible, with measurement data from preconstruction critical experiments at HFIR, data included in the current HFIR safety analysis report, and/or data from previous calculations performed with different methods or codes. The results of the analyses show that the models presented in this report provide a robust and reliable basis for HFIR analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MCNP TREAT Core Model with Big-BUSTER

This MCNP model contains the Big-BUSTER experiment containment system within the TREAT core in a half slot configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MCNP TREAT Core Model with MIMIC-N

This MCNP model contains the MIMIC-N materials and instrumentation test and the BUSTER containment system within the TREAT core in a full slot configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Beam Characterization at the Neutron Radiography Facility

The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of Moderated Highly Enriched Uranium Slabs

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with HEU-MET-FAST-007, “Uranium Metal Slabs Moderated with Polyethylene, Plexiglas, and Teflon”. The Monte Carlo n-Particle (MCNP) models were compared to the second revision of HEU-MET-FAST-007. The experiment considered critical configurations of highly enriched uranium (HEU) metal slabs and various moderators in 43 unique cases. The slabs of uranium were separated by layers of moderating material, forming an assembly. The assembly was separated in two halves with one half placed on a stationary table and the other attached to a moveable table that could be raised and lowered via pulleys connected to the ceiling of the shielded room. To reach criticality, the two halves were brought together with a negligible gap between the assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Modeling of Z1: Validation of a Novel Radioisotope System

This paper presents the development of a radiation model for a novel strontium-90 (Sr-90) radioisotope heat source developed by Zeno Power Systems (Zeno), which demonstrates a groundbreaking fuel and shielding design that significantly reduces weight compared to traditional concepts. A Monte Carlo N-Particle (MCNP) model has been created to assess the effectiveness of this fuel and shielding design, however validation of the MCNP model is desired. Zeno has developed a prototype device (Z1) to aid in this model validation effort. This project is a collaborative effort between Zeno, the University of Dayton Research Institute (UDRI) and Pacific Northwest National Laboratory (PNNL), where the Z1 prototype was constructed and characterized.

RTG↗

Beam characterization at the Neutron Radiography Reactor

The quality of a neutron-imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam's effective length-to-diameter ratio, neutron flux profile, energy spectrum, potential image quality, and beam divergence, is vital for producing quality radiographic images. This paper provides a characterization of the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam's effective length-to-diameter ratio and potential image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. The NRAD has an effective collimation ratio greater than 125, a beam divergence of 0.3 +_ 0.1 degrees, and a gold foil cadmium ratio of 2.7. The flux profile has been quantified and the facility is an ASTM Category 1 radiographic facility. Based on bare and cadmium covered foil activation results, the neutron energy spectrum used in the current MCNP model of the radiography beamline over-samples the thermal region of the neutron energy spectrum.

99 GENERAL AND MISCELLANEOUS↗

Characterization of the Contaminated Soil Under the Hanford 324 Building B Cell, Washington, USA - 12182

The 324 Building on the Hanford site played a key role in radiochemical and metallurgical research programs conducted by DOE. The B hot cell in the 324 Building was the site of high-level waste vitrification research. During clean-out operations in November 2009, a tear was noted in the stainless steel liner on the floor of B Cell. Exposure rate readings taken at various locations in the soil about 0.5 meters below B Cell reached 8,900 Roentgen (R) per hour, confirming the existence of a significant soil contamination field. The source of the radioactive material was likely a 510 L spill from the Canister Fabrication Project, consisting of purified, concentrated Cs-137 and Sr-90 solutions totaling 48,000 TBq (1.3 MCi). MCNP modeling was used to estimate that the measured exposure rates were caused by 5,900 TBq (160 kCi) of Sr- 90 and Cs-137, although additional contamination was thought to exist deeper in the soil column. Two physical soil samples were obtained at different depths, which helped verify the contamination estimates. A detailed exposure rate survey inside B Cell was combined with additional MCNP modeling to estimate that an additional 1,700 TBq (460 kCi) is present just below the floor. Based on the results of the sampling campaign, it is likely that the radioactive material below B Cell is primarily consists of feed solutions from the FRG Canister Fabrication Project, and that it contains purified Sr-90 and Cs-137 with enough actinide carryover to make some of the soil transuranic. The close agreement between the Geoprobe calculations and the physical samples adds confidence that there are more than 3700 TBq (100,000 Ci) of Sr-90 and Cs-137 in the soil approximately 1 meter below the cell floor. The majority of the Cs-137 is contained in the first meter of soil, while significant Sr-90 contamination extends to 10 meters below the cell floor. It is also likely that an additional 15,000 TBq (400,000 Ci) of Cs-137 and Sr-90 activity is present directly below the floor of the cell, and that the residual activity inside the cell is only half of the previous estimates. However, the partitioning of activity between residuals in the cell and in the soil below the floor is much more uncertain than the activity calculations associated with the Geoprobe measurements. Taken together, the calculated soil activities represent about half of the spill associated with the FRG Canister Fabrication project. The remainder of the spill is believed to have remained in the cell, where the majority has been removed as part of cell cleanup activities. The magnitude of the soil contamination below 324 B Cell is sobering, and it represents one of the most challenging remediation activities in the DOE complex. Of course, safe remediation begins with a good understanding of the magnitude of the problem. As a result, additional modeling and cross-comparison efforts are planned for 2012. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗