Search NASA⌕ Search

SEARCH · Search NASA

Results for “MCNP6.2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Release Notes for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015-2016, Whisper was updated to version 1.1 [9] and is to be included with the upcoming release of MCNP6.2. This document describes the Whisper-1.1 package that will be included with the MCNP6.2 release during 2017. Specific details are provided on the computer systems supported, the software quality assurance (SQA) procedures, installation, and testing. This document does not address other important topics, such as the importance of sensitivity-uncertainty (SU) methods to NCS validation, the theory underlying SU methodology, tutorials on the usage of MCNP-Whisper, practical approaches to using SU methodology to support and extend traditional validation, etc. There are over 50 documents included with Whisper-1.1 and available in the MCNP Reference Collection on the MCNP website (mcnp.lanl.gov) that address all of those topics and more. In this document, however, a complete bibliography of relevant MCNP-Whisper references is provided.

97 MATHEMATICS AND COMPUTING↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools Case Studies of Benchmarks and Applications

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP ® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. The initial comparison involves four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been: 1. modeled independently by LANL, IRSN, and ORNL based upon information provided in the ICSBEP Handbook, 2. are common in S/U libraries for LANL, IRSN, and ORNL, 3. span a range of energy spectrum and fissile material, and 4. taken as applications for the purposes of this study and therefore excluded from use as a benchmark for calculating the upper subcritical limit. Results presented in this paper have been computed using covariance data for all isotopes in ENDF/BVII.0 using a 44-group energy structure. Benchmarks in the Whisper library were run in MCNP6.2 using 100,000 neutrons per cycle, skipping 100 cycles for 500 active cycles. Reference 10 also compares the results for baseline USL with an order of magnitude greater neutrons, using the same total number of cycles with 1,000,000 neutrons per cycle. Subsequent to the results presented in Reference 10 changes were made to the benchmark library, as discussed in Reference 11. Newer results using the revised benchmark library are presented herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MITR & NBSR DDE Irradiations in BR2 – Fluence in LEU Cladding and Structural Materials

The BR2 nuclear reactor is a material testing reactor (MTR) located in Mol, Belgium, and operated by the Belgian Nuclear Research Centre (SCK CEN) since 1963. The reactor is highly versatile as the number and location of fuel elements and control rods can change significantly from cycle to cycle to accommodate different needs. Argonne National Laboratory (ANL or Argonne) Reactor Conversion (RC) team has collaborated with SCK CEN for over a decade on the conversion of domestic and international research reactors from highly enriched uranium (HEU, ≥20 wt.% of 235 U) to low enriched uranium (LEU, <20 wt.% of 235 U) fuel. The U.S. High-Performance Research Reactor (USHPRR) project within the M3 Reactor Conversion Program aims at converting five U.S. high performance research reactors (MITR, MURR, NBSR, HFIR, and ATR) and one critical facility (ATR-C) to LEU fuel. These USHPRRs still use and regularly refuel with HEU fuel. Each facility has a unique reactor design, operating conditions, and fuel element design to accomplish its mission. The goal of the USHPRR project is to convert the USHPRRs and the critical facility to LEU fuel while maintaining experimental performance and ensuring safe facility operation. The current technical report focuses on two reactors requiring very high-density LEU fuel: the Massachusetts Institute of Technology Reactor (MITR) and the National Bureau of Standards Reactor (NBSR). To support the conversion of these reactors, so-called design demonstration elements (DDE) are planned to be irradiated in the BR2 reactor under conditions similar to the targeted reactors and using a prototypic geometry. In support of this experiment, SCK CEN studied and modeled the DDE irradiations using MCNP6.2 to investigate the feasibility of irradiating the MITR DDE and NBSR DDE in BR2. Argonne reviewed and confirmed the conclusions of this study. Structural analysis is another step toward converting USHPRR to LEU fuel. The objective of the current report is to provide information useful to the structural analysis of the NBSR & MITR DDEs to support its irradiation in BR2. Specifically, the goal is to provide the fast neutron (E>0.1MeV) fluence in the cladding of the fuel plates in BR2 for the whole period of irradiation (8 cycles for MITR DDE and 10 cycles for NBSR DDE). Additionally, fast neutron fluences in the side plates and in the NBSR DDE’s outside plates were calculated and reported. Neutronic calculations were performed using MCNP6.2 on the RTRHPC cluster.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

Energy deposition validation results for the evaluated electron data library in FRENSIE - 25357

The Framework for Research in Nuclear Science and Engineering (FRENSIE) is a collection of packages written in C++ that are designed primarily to aid in methods development. A recent development in FRENSIE is the modeling of single scattering electron interactions using the data in the Evaluated Electron Data Library (EEDL) from Lawrence Livermore National Laboratory (LLNL). Preliminary verification and validation (V and V) results using the well-known Lockwood energy deposition experiment and a comparison with MCNP6.2 were performed using several bivariate grid policies (Unit-base, Correlated, Unit-base Correlated), interpolation schemes (lin-lin, log-log, lin-log), and physics options (Coupled and Decoupled Elastic Scattering). The results show an agreement to within 0.5% between MCNP6.2 and FRENSIE when using the same bivariate grid policy (Correlated) and interpolation scheme (log-log). When compared to the experimental results of the Lockwood experiment, it was found that a Unit-base bivariate grid policy, lin-lin interpolation scheme, and lin-log interpolation scheme did not produce accurate results for the energy deposition in test problems. The log-log Correlated and Unit-base Correlated results showed the greatest agreement with the Lockwood experiment. The total energy deposition matched the experimental data to within 3%. Both the Correlated and Unit-base Correlated results had a tendency to estimate a higher energy deposition near the peaks and a lower energy deposition near the tails. The differences between coupled elastic scattering and decoupled scattering models were shown to be more prominent at higher energies with the results of the coupled elastic scattering being more accurate for the peak and less accurate for the tail of the energy deposition profiles. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of Nuclear Data Covariances on Integral Experiment Design with Sensitivity and Uncertainty Analysis

Washington River Protection Solutions (WRPS) uses MCNP6.2 and the Whisper code for criticality safety analyses of the Hanford Tank Farm. Together the codes derive baseline upper subcritical limits (USLs) for the waste models using experimental benchmarks. Whisper returns higher USLs, i.e. , has less of a conservative penalty, when the neutronic similarity of the experimental benchmarks to the application is high. Unfortunately, few critical benchmarks have high similarity to the Hanford tanks. The waste in the tanks is highly dilute in plutonium and contains large masses of weakly neutron-absorbing elements like iron and manganese. Experimental benchmarks typically have low sensitivity to these absorbers because they are present as structural materials. Lacking similar benchmarks, new Thermal Epithermal eXperiment (TEX) configurations with high Pu content and interstitial iron absorbers have been designed for the criticality safety validation. The features of the design have been iterated upon to maximize the similarity between the experiment and different Hanford waste models. The similarity is quantified with sensitivity analysis and uncertainty quantification using the representativity coefficient, or c k . The representativity calculation requires nuclear data covariances, which may differ between nuclear data libraries and between library versions. Because of these variations, the optimal design may depend on the nuclear data covariances library. A scenario can be envisioned where an experiment is designed, and c k is maximized, with one set of covariance data. However, when the covariance data is changed, say from ENDF/B-VII.1 to ENDF/B-VIII.0, and the benchmark is used in a criticality safety evaluation, the experiment becomes suboptimal with respect to c k . In this paper, we present how the optimal design of the new TEX experiments varied depending on the nuclear data covariances used to calculate c k . We compare ENDF/B-VII.1 and ENDF/B-VIII.0, as if the library had been updated since the design of the experiment. Additionally, we use JEFF3.3 to simulate if the covariance data of a different library had been used. The results show that the covariances do have an important effect on the designs, less so for thermal systems (where the data are more consistent between evaluations) and more so for epithermal systems where more differences exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PMT-004 Validation Testing for Thermal Scattering Laws and Some Interesting Temperature-Dependent Implications [Slides]

This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). Additionally discovered was that the PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff likely due to the lack of integral benchmarks sensitive to PMMA. The NCSU ENDF/B-VIII.1 PMMA TSL is an improvement over VIII.0. This was Accepted at last ICSBEP meeting pending comment resolution, should be published in 2024 version of the Handbook. It was found that temperature had a large impact on reactivity of the critical configuration. This has Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to add in data testing and benchmark adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission Reaction Event Yield Algorithm FREYA 2.0.2

The purpose of this paper is to present the main differences between FREYA versions 1.0 and 2.0.2. FREYA (Fission Reaction Event Yield Algorithm) is a fission event generator which models complete fission events. As such, it automatically includes fluctuations as well as correlations between observables, resulting from conservation of energy and momentum. The main differences between the two versions are: additional fissionable isotopes, angular momentum conservation, Giant Dipole Resonance form factor for the statistical emission of photons, improved treatment of fission photon emission using RIPL database, and dependence on the incident neutron direction. FREYA 2.0.2 has been integrated into the LLNL Fission Library 2.0.2, which has itself been integrated into MCNP6.2, TRIPOLI-4.10, and can be called from Geant4.10.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Lastly, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the Second Target Station cold source moderators using an automated workflow

The Second Target Station (STS) at the US Department of Energy’s Oak Ridge National Laboratory is designed to become the world’s highest peak-brightness spallation source of cold neutrons. Successful completion of the STS, which is currently in the preliminary design phase, will provide transformative new capabilities to examine novel materials for future technologies. At STS, neutrons will be generated by spallation reactions in a solid tungsten target. They will be moderated and thermalized in two cold (20 K) para-hydrogen moderators. Careful optimization of these moderators is essential to the project’s success. To find optimal moderator designs, an advanced optimization workflow integrates high-fidelity neutronics calculations using the Monte Carlo N-Particle (MCNP) transport code MCNP6.2 with state-of-the-art optimization algorithms in the Dakota optimization toolkit. For each design iteration, a parametrized solid CAD geometry is generated in Creo and automatically converted into an unstructured mesh geometry by Attila 4MC for the neutronics calculation with MCNP. Iterations repeat until optimal designs are found. Herein this paper presents the results of a sensitivity and optimization study for the cylindrical and tube moderators. Both moderators can be optimized for maximum peak brightness, maximum time-integrated brightness, or any combination between these extremes. Maximum peak brightness is achieved by using smaller optimal dimensions of the moderators, whereas maximum time-integrated brightness is achieved by using larger dimensions. A Pareto front details the designs that optimally balance both brightness metrics. The Pareto front can be found in only 40–110 iterations with 4–5 design parameters when using the efficient global and Pareto-set optimization algorithms in Dakota. Additionally, important engineering constraints can be taken into account, such as the coupling between the cylindrical moderator radius and aluminum vessel wall thicknesses required to ensure structural integrity of the vessels. This interaction has a significant impact on the resulting optimal designs. Our new, highly efficient, fully automated optimization workflow will be used to optimize additional STS components in the future and can be adopted for design and optimization studies at other experimental neutron and accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled beam-target-moderator optimization for the Second Target Station

To support the design of the Second Target Station, that aims to provide the world’s highest peak brightness of cold neutrons, studies that optimize the dimensions of the target and moderators are invaluable. In this work, we investigate the influence of the target dimensions and beam profile on the performance and optimal size of the moderators. We perform optimization runs with detailed MCNP6.2 simulations using high-fidelity unstructured mesh geometries generated from parametrized CAD models. We demonstrate that small changes in target height do not influence the moderator performance if the beam dimensions are chosen adequately. We quantify the effect of beam footprint and target width on the moderator performance and show that the optimal moderator dimensions are insensitive to limited changes in target and beam profile.

Dakota↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗