Search NASA⌕ Search

SEARCH · Search NASA

Results for “MERCURY VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Internal erosion rates of a 10-kW xenon ion thruster

A 30 cm diameter divergent magnetic field ion thruster, developed for mercury operation at 2.7 kW, was modified and operated with xenon propellant at a power level of 10 kW for 567 h to evaluate thruster performance and lifetime. The major differences between this thruster and its baseline configuration were elimination of the three mercury vaporizers, use of a main discharge cathode with a larger orifice, reduction in discharge baffle diameter, and use of an ion accelerating system with larger acceleration grid holes. Grid thickness measurement uncertainties, combined with estimates of the effects of reactive residual facility background gases gave a minimum screen grid lifetime of 7000 h. Discharge cathode orifice erosion rates were measured with three different cathodes with different initial orifice diameters. Three potential problems were identified during the wear test: the upstream side of the discharge baffle eroded at an unacceptable rate; two of the main cathode tubes experienced oxidation, deformation, and failure; and the accelerator grid impingement current was more than an order of magnitude higher than that of the baseline mercury thruster. The charge exchange ion erosion was not quantified in this test. There were no measurable changes in the accelerator grid thickness or the accelerator grid hole diameters.

Rawlin, Vincent K.↗

Internal erosion rates of a 10-kW xenon ion thruster

A 30 cm diameter divergent magnetic field ion thruster, developed for mercury operation at 2.7 kW, was modified and operated with xenon propellant at a power level of 10 kW for 567 h to evaluate thruster performance and lifetime. The major differences between this thruster and its baseline configuration were elimination of the three mercury vaporizers, use of a main discharge cathode with a larger orifice, reduction in discharge baffle diameter, and use of an ion accelerating system with larger acceleration grid holes. Grid thickness measurement uncertainties, combined with estimates of the effects of reactive residual facility background gases gave a minimum screen grid lifetime of 7000 h. Discharge cathode orifice erosion rates were measured with three different cathodes with different initial orifice diameters. Three potential problems were identified during the wear test: the upstream side of the discharge baffle eroded at an unacceptable rate; two of the main cathode tubes experienced oxidation, deformation, and failure; and the accelerator grid impingement current was more than an order of magnitude higher than that of the baseline mercury thruster. The charge exchange ion eroison was not quantified in this test. There were no measurable changes in the accelerator grid thickness or the accelerator grid hole diameters.

Rawlin, Vincent K.↗

Thin electrostatically self-focusing electron streams.

Study of 30 to 380 microampere, 50 to 550 V, 1 to 2 mm, electrostatically self-focusing electron streams (50 cm long) drifting through mercury vapor (at 50 microtorr to 2 millitorr) in a tube with a radius of 6.6 cm. The inside surface of the tube is coated with a transparent layer whose resistivity is 50 ohm-cm per centimeter. In order to determine the charged-particle densities and the potential profile in and around the beam without disturbing the system, a multigrid electrostatic charged particle energy analyzer was used to study separately the energy distributions of both ions and electrons ejected radially from the beam. The results show two energy groupings for electrons. The energy distribution of the high-energy group is produced by ionizing collisions between beam electrons and neutral gas atoms; a group of flow-energy electrons becomes trapped in the potential well within and around the beam, subsequently escaping by collisional mechanisms.

Mccorkle, R. A.↗

Cathode effects on thrust subsystem performance predictability.

Development of a model of mercury vapor electron bombardment thrustor hollow cathode operation. The proposed model predicts that the primary electron emission mechanism is thermionic when sufficient low work function material is present, that the cathode is heated by power extracted from the plasma to a temperature sufficient to emit the current demanded by the external circuit; that for a given total arc current, attempts to reduce cathode temperature by changes in the external thermal coupling will affect only the amount of power extracted from the plasma; and that depletion of low work function material in the cathode results in higher cathode temperature.

Goldstein, R.↗

Theory of a steady-state nonisothermal positive column in a magnetic field.

The steady state of a nonisothermal cylindrical discharge in a longitudinal magnetic field is described by three moment equations in the plasma approximation for electrons and ions. Volume generation of electron-ion pairs by single-stage ionization, the presence of axial current, and collisions with neutrals are considered. The theory yields radial profiles of the charged particle velocities, density, potential, electron and ion temperatures, and demonstrates similarity laws for the positive column. The results are compared with two-moment theories and with experimental data on helium, argon, and mercury vapor found in the literature for a wide range of pressures.

Ilic, D. B.↗

Accelerated Solar-UV Test Chamber

Medium-pressure mercury-vapor lamps provide high ratio of ultraviolet to total power. Chamber for evaluating solar-ultraviolet (UV) radiation damage permits accelerated testing without overheating test specimens.

Gupta, A.↗

Arc discharge convection studies: A Space Shuttle experiment

Three mercury vapor arc lamps were tested in the microgravity environment of one of NASA's small, self-contained payloads during STS-41B. A description of the payload structural design, photographic and optical systems, and electrical system is provided. Thermal control within the payload is discussed. Examination of digital film data indicates that the 175 watt arc lamp has a significant increase in light output when convection is removed in the gravity-free environment of space.

Bellows, A. H.↗

JPL nuclear electric propulsion task

The development of lithium magnetoplasmadynamic (MPD) thrusters at JPL is discussed. The following topics are presented in vugraph form: mercury vapor mass flow control; porous tungsten vaporizer and housing; the lithium vaporizer experiment; a dry box for handling solid lithium; MPD thruster electrode modeling; engine lifetime definitions; cathode failure modeling; cathode erosion modeling; cathode thermal modeling; near cathode plasma model regions; cathode work function modeling; anode work function modeling; and radiation-cooled anodes.

Pivirotto, Tom↗

Investigation of a laboratory candidate for the carrier of the 4430 A diffuse interstellar band

The 4430 A diffuse interstellar band (DIB) is unique among DIB's in that as one of the strong bands, it is the bluest strong band with no others observed at shorter wavelengths. This position at the edge of the DIF 'forrest' suggests it may be the easiest to replicate in the laboratory. In earlier experiments (Wdowiak 1980) an interesting candidate using a gas discharge followed by cryogenic matrix isolation was produced, and this report details its further investigation. This absorption feature, produced when 1 part CH4 in 200 parts Ar is discharged and frozen out approximately 10 K, is at a wavelength of 4500 A in the argon matrix. Our recent experiments strongly indicate it is due to a carbon-based reactive species that is stable against mercury vapor UV radiation, and not likely to be from a contaminant. The effect of matrix shift can be estimated by considering the blueward shift between Ar and Ne matrices in the cases of the pyrene and C60 cations. This suggests that a shift from 4500 A for an Af matrix to the vicinity of 4300 A for a Ne matrix and the gas phase is not unreasonable. A liquid He cooled Ne matrix isolation experiment was prepared to determine the wavelength of the feature in that matrix. Replacing CH4 with C2H2 results in an equivalent absorption due to C3, greatly diminished absorptions from C2 and Ch, and no observable feature at 4500 A. To date our experiments indicate CH4 is a favored precursor for production of the reactive carrier of the 4500 A feature. Perhaps C2H2 is not suitable because of its tendency to polymerize easily in the discharge.

Wdowiak, Thomas J.↗

An Experimental Study of the Ionization of Low-Density Gas Flows by Induced Discharges

Induced discharges are advantageous for ionizing low-density flows in that they introduce no electrode contamination into the flow and they provide a relatively high degree of ionization with good coupling of power into the gas. In this investigation a 40-megacycle oscillator was used to produce and maintain induced discharges in argon and mercury-vapor flows. Methods for preventing blowout of the discharge were determined, and power measurements were made with an in-line wattmeter. Some results with damped oscillations pulsed at 1,000 pulses per second are also presented.

Barger, R. L.↗

Neon as a Buffer Gas for a Mercury-Ion Clock

A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump is used to maintain the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a buffer gas. Neon was determined to be the best choice for the buffer gas: The pressure-induced frequency pulling by neon was found to be only about two-fifths of that of helium. Furthermore, because neon diffuses through solids much more slowly than does helium, the operational lifetime of a tube backfilled with neon could be considerably longer than that of a tube backfilled with helium.

Prestage, John↗