Search NASA⌕ Search

SEARCH · Search NASA

Results for “MERLIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sizing comingled CF/PA 6 fibers with cellulose nanofibrils for enhanced performance properties

Compatibility between the reinforcing phase and the polymer matrix is critical to achieving the desired mechanical and thermal performance of composite materials. Several mechanisms can enhance this interfacial interaction, including surface treatments (e.g., oxidation, plasma, or irradiation), in-situ nanoparticle deposition, and fiber sizing. Here, in this study, cellulose nanofibrils (CNF) were employed as a sustainable sizing agent to modify the interface in commingled carbon fiber (CF)/polyamide 6 (PA 6) yarns, in which CF and PA6 filaments are intimately blended to enable simultaneous consolidation. A 0.25 wt% CNF aqueous suspension was applied under bath sonication to ensure uniform dispersion and minimize agglomeration. CNF-sized and unsized yarns were used to fabricate unidirectional composite plates via filament winding on a flat mandrel, followed by compression molding. Scanning electron microscopy confirmed CNF presence on both CF and PA6 filaments. CNF-sized composites exhibited increments in interlaminar shear strength (ILSS) by 50%, flexural strength by 11%, and tensile strength by 2.5% compared to unsized composites. Thermal analysis showed minimal changes in degradation temperature and crystallinity. These findings demonstrate that CNF sizing enhances interfacial bonding and mechanical performance, offering a scalable and environmentally friendly strategy for thermoplastic composite manufacturing along with yarn/tow handleability.

Cellulose nanofibrils (CNF)↗

Low cost textile-grade carbon-fiber epoxy composites for automotive and wind energy applications

Carbon fiber reinforced polymer composites are highly desirable for automotive and wind energy applications due to advantages associated with weight reduction, high stiffness and strength, durability, and recyclability. The high cost of carbon fiber has been a limiting factor in its widespread adoption in non-aerospace applications. A low cost (estimated < $11 per kg) wide tow (450-600k) carbon fiber derived from textile grade polyacrylonitirile precursor, and hence called Textile Grade Carbon Fiber (TCF) is introduced in this paper. Fundamental aspects of the TCF are discussed along with a detailed characterization of its mechanical properties. Two manufacturing processes relevant to automotive and wind energy applications are considered, namely-compression molding and resin infusion. Furthermore, at various stages the TCF has been compared to commercial non-aerospace 50k carbon fiber composite. Detailed physical and mechanical properties including tensile, flexural, compression, and interlaminar shear properties are reported and compared to non-aerospace carbon fiber composite. The results provide a means for designers and end-users in the automotive and wind energy sector to consider different forms of economical non-aerospace carbon fibers.

42 ENGINEERING↗

Enhanced through-thickness electrical conductivity and lightning strike damage response of interleaved vertically aligned short carbon fiber composites

Through-thickness electrical conductivity of carbon fiber reinforced polymers (CFRPs) is a key characteristic that determines the severity of lighting strike-induced damage. Carbon Fibers (CFs) are inherently electrically conductive and therefore provide high conductivity in the direction of the fiber orientation. However, electrical conductivities through the thickness and orthogonal to the CF orientation in CFRPs are governed by the insulating polymer matrix present between CFs. Here, in this work, through the thickness alignment of short CFs in between layers of CFRP laminates is demonstrated to improve the through-thickness electrical conductivity. Composites with interleaved vertically aligned short CF fibers (<150 μm) will be referred as V-fiber composites hereafter. The effect of the V-fiber on the lightning strike damage is evaluated against an artificial lightning strike of 100 kA (modified waveform A of SAE ARP-5412B standard). The improved through-thickness electrical conductivity of CFRP laminates (1.15 S/cm) through vertical alignment of short CFs was compared to reference CFRP laminates (0.13 S/cm) and was found to dissipate the artificial lightning strike current more efficiently. The surface damage after the artificial lightning strike in the V-fiber composites was reduced to 12.69 cm 2 compared to the reference CFRP surface damage of 57.67 cm 2 , a 78% reduction. It was also demonstrated that Joule heat generated due to lightning strike on the composites was significantly less than the reference sample using infrared (IR) thermography. A high retention (up to 78%) of flexural properties (modulus and strength) was observed in V-fiber composites post lightning strike impact as compared to only 47% retention in the reference panel.

42 ENGINEERING↗

Silicon carbide fiber manufacturing: Cost and technology

Significant advances have been made in the past decade concerning silicon carbide fiber manufacturing methods resulting in near-stoichiometric small-diameter fibers that meet the property requirements for most of the ceramic matrix composites (CMC) and nuclear applications. The manufacturing cost, however, remained prohibitively high, preventing the use of it in different applications requiring much lower cost. Silicon carbide (SiC) fiber reinforced CMC is dominated by the cost of SiC fiber which comprises more than 50 % of the finished part cost. Here, this article provides insight into the SiC fiber manufacturing costs and highlights the need for an alternative SiC fiber precursor and manufacturing method. Analysis of the existing polycarbosilane (PCS)-based SiC fiber manufacturing shows that the crosslinking (curing) and raw material preparation steps are high-cost steps that need lower cost options. Alternative SiC fiber precursor should be sought for lowering the cost of SiC fibers.

36 MATERIALS SCIENCE↗

Internal arcing and lightning strike damage in short carbon fiber reinforced thermoplastic composites

Short carbon fiber reinforced thermoplastic composites (S-CFRTP) are currently used in interior parts of aircraft such as electronic circuitry and assemblies, and their usage in aircraft's exterior is also being studied. In this paper, we present a lightning strike study on S-CFRTPs. High performance thermoplastics such as a polyphenylene sulfide (PPS) reinforced with 50% weight (wt.) short carbon fiber (CF), a polyphenyl sulfone (PPSU) reinforced with 25 % wt. Short CF and a acrylonitrile butadiene styrene (ABS) with 20 % wt. short CF were tested against artificial lightning strikes. All samples were prepared using an extrusion compression molding (ECM) technique. A modified component A (100 kA) of lightning waveform, as defined by SAE ARP 5412-B, was applied. High speed imaging, thermography, scanning electron microscopy (SEM) and ultrasonic non-destructive evaluation were performed to understand the effect of lightning strikes on the thermoplastic panels. The results show that electrical conductivity of the composite, thermal stability of the polymers, and CF orientation significantly affected the damage from artificial lightning strikes. PPS composite had the highest resilience against lightning strike damage, retaining 95% and 89% residual flexural strength and modulus, respectively. CF exfoliation due to internal arcing was observed in the carbon fiber-reinforced ABS polymer (CF-ABS) composite. CF exfoliation damage has been reported for the first time.

36 MATERIALS SCIENCE↗

Moderate pH changes alter the fluxes, selectivities and limiting currents in ion transport through polyelectrolyte multilayers deposited on membranes

Layer-by-layer (LBL) polyelectrolyte coatings on membranes are attractive for their high selectivities between monovalent and divalent ions. However, deposition of poly(4-styrenesulfonate) (PSS)/protonated poly(allylamine) (PAH) films on ion-exchange membranes leads to low ion fluxes that restrict productivity or current efficiency. This study shows that increasing the solution pH from 6.5 to 8.3 enhances cation fluxes and limiting currents through (PAH/PSS) 5 PAH-coated cation-exchange membranes while still achieving order of magnitude selectivity increases compared to bare membranes. In Donnan dialysis through (PAH/PSS) 5 PAH-coated Nafion, at pH 8.3 the K + /Mg 2+ selectivity is 100, and the K + flux is 22 times that at pH 6.5. Moreover, at the higher pH the electrodialysis limiting current through these membranes increases ~5-fold. This enables electrodialysis separation of K + and Mg 2+ with a current efficiency around 0.75, a selectivity of 18, and 50% K + recovery from the source phase. Transmembrane potential measurements and increases in Cl - /SO 4 2- selectivities (from 9.5 at pH 6.5 to ~70 at pH 8.3) for porous alumina membranes coated with (PSS/PAH) 5 PSS films suggest that the coating becomes cation-permselective at higher pH. Increased cation transference numbers in polyelectrolyte coatings likely lead to the enhanced limiting currents for coated Nafion at higher pH. Lastly, (PAH/PSS) 5 PAH-coated Nafion shows a Li + /Mg 2+ Donnan dialysis selectivity >700 at neutral pH and a selectivity of 10 at pH 8.3. However, the Li + flux is 6 times greater at pH 8.3, which might make operation at the higher pH desirable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electro-osmo-dialysis through nanoporous layers physically conjugated to micro-perforated ion-exchange membranes: Highly selective accumulation of trace coions

This study explores theoretically and numerically the phenomenon of counter-flow accumulation of trace coions during electro-osmo-dialysis through composite membranes containing nanoporous and perforated ion-exchange layers. The combination of charged nanopores and perforations allows electroosmosis, and ion concentration polarization appears near the ion-exchange layer. Accumulation of trace coions occurs because their advective and electromigration flow velocity components have opposite signs and are locally compensating in depletion regions where electric fields are high. This local compensation of flow components can give rise to high accumulation factors (>1000 in some cases) for trace coions at some distance from the interface between the nanoporous and ion-exchange layers. Moreover, the extent of this accumulation depends on the trace-coion diffusion coefficient. The resulting selectivity between different coions might serve as a basis for environmentally friendly separation of ionic species such as synthetic peptides or rare-earth elements. For example, a periodic process might include accumulation followed by species release into smaller volumes of solution. For both rare-earth ions and peptide-like species, the accumulation selectivity between ions with small differences in mobilities depends on system parameters such as nanoporous-layer thickness, distance between the perforations, and the zeta potential of the nanopore surface. Here, the use of optimal values of these membrane parameters may enable tuning of the electro-osmo-dialysis system for separation of specific ions. Modelling reveals that despite inhomogeneous patterns of fluid and ion flows close to the nanoporous/perforated ion-exchange interface, at relatively short distances from this interface (less than half the distance between the perforations) all the flows become practically one-dimensional (1D). Similarly, the concentration profiles of trace coions also become 1D. The flow one-dimensionality at short distances from the current-polarized interface enables a simple 1D approximation that is useful for an approximate analysis of trends in this multi-parameter system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly selective ion separations based on counter-flow electromigration in nanoporous membranes

Highly selective ion separations are vital for recovering important salts, and membrane-based techniques may enable environmentally friendly ion separations that operate continuously. This study demonstrates that simply opposing convective flow with electromigration in track-etched membranes leads to remarkable selectivities among monovalent ions. Because the membrane-pore diameters are orders of magnitude larger than the ion diameters, advection moves all ions at the same velocity, whereas electrophoretic velocities are proportional to ion mobilities. Thus during counter-flow cation electromigration, less mobile cations have lower electromigration velocity components and pass through porous membranes more rapidly than more mobile cations. Using membranes with 400 nm pores, counter-flow electromigration gives Li + /K + selectivities of 100 and Li + /Na + selectivities around 30 in mixed-salt studies. In this work, numerical simulations based on the extended Nernst-Planck equation agree with trends in experimental data and highlight the importance of high Péclet numbers, high current-to-flow ratios, and uniform current distributions for achieving high selectivities. Importantly, experimental separations give high selectivities at 0.3 M ionic strength and low Li + /K + ratios, which suggest these methods may also work in brine solutions. Nevertheless, energy costs for such separations are high.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrodialysis through nafion membranes coated with polyelectrolyte multilayers yields >99% pure monovalent ions at high recoveries

Separation of monovalent and multivalent ions is important in processes ranging from water softening to recycling of Li. Previous studies show that cation-exchange membranes coated with multilayer polyelectrolyte films exhibit monovalent/divalent ion selectivities as high as 1000 in electrodialysis (ED) under ideal conditions with low ion recoveries. This work shows that even at 60-80% monovalent-ion recoveries, ED through Nafion membranes coated with protonated poly(allylamine)/poly(4-styrenesulfonate) multilayers can separate equimolar K + and Mg 2+ or Li + and Mg 2+ to give 99.5% pure monovalent ion. Moreover, the use of a low-volume receiving phase allows ED to concentrate the monovalent ion. Typical current efficiencies are around 70% for these separations. Selectivities appear to increase when the membrane-coating procedure uses a higher polyelectrolyte concentration in the deposition solution. Because the limiting current declines with ED time due to depletion of the monovalent ion in the source phase, use of a gradually decreasing applied current enhances current efficiency compared to ED at a constant high current. Further, the membranes also show Li + /Mg 2+ selectivities around 100 when Mg 2+ is in a 20-fold excess in the source phase at an ionic strength of 0.6 M, but selectivity decreases at even higher ionic strengths.

15 GEOTHERMAL ENERGY↗

Selective concentration of multivalent cations via electrodialysis through tandem membranes

Selective electrodialysis is attractive for recovering and recycling valuable ions. However, most studies in this field focus on membranes that are selective for monovalent ions. Multivalent cations preferentially partition into cation-exchange membranes, but low mobilities and concentration polarization limit electrodialysis selectivities for these cations. This work employs electrodialysis through an “in-series” combination of a Nafion membrane and a multilayer polyelectrolyte film (MPF)-coated Nafion membrane to concentrate and isolate La 3+ or Mg 2+ from monovalent ions. The bare Nafion membrane gives a La 3+ /Na + selectivity up to 4 (depending on conditions), which enables concentration of La 3+ with a high current efficiency. The MPF-coated membrane allows selective passage of Na + while rejecting La 3+ to increase the purity of the concentrated multivalent cation. For example, the concentration of La 3+ in the accumulation solution can reach 9 times its original concentration in the feed solution with a purity of 93 mol% (99 wt%) when starting with equimolar mixtures of NaNO 3 and La(NO 3 ) 3 . This study examines how the separation varies with the type of polyelectrolyte, the applied voltage, and the composition of feed, accumulation, and cathode solutions. Here, a high nitric acid concentration (0.5 M) in the cathode compartment allows monovalent anions to pass through the MPF-coated Nafion membrane to maintain the electroneutrality of the accumulation solution. With a low acid concentration (0.04 M) in the cathode chamber, water splitting occurs at the MPF-coated membrane and La(OH) 3 precipitates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective antiviral coatings for deactivating SARS-CoV-2 virus on N95 respirator masks or filters

The application of antiviral coatings to masks and respirators is a potential mitigating step toward reducing viral transmission during the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) pandemic. The use of appropriate masks, social distancing, and vaccines is the immediate solution for limiting the viral spread and protecting people from this virus. N95 respirator masks are effective in filtering the virus particles, but they cannot kill or deactivate the virus. We report a possible approach to deactivating SARS-CoV-2 by applying an antimicrobial coating (Goldshield 75) to masks and respirators, rendering them suitable for repeated use. Masks coated with Goldshield 75 demonstrated continuous inactivation of the Alpha and Beta variants of the SARS-CoV-2 over a 3-day period and no loss of inactivation when stored at temperatures at 50 °C.

36 MATERIALS SCIENCE↗

Improvement of interfacial adhesion of unidirectional textile grade carbon fiber (TCF) with unsized, epoxy and urethane sizing reinforced in thermoset urethane composites

This work considers a unique wide tow (450k filaments) form of low-cost carbon fiber intended for non-aerospace applications. TCF is currently produced in epoxy and urethane sizing, and there is a need to understand its resulting composite properties. In this work, the interfacial adhesion of sized TCF reinforced in thermoset urethane (TSU) composites are examined through the surface, thermal and mechanical characterization techniques. Atomic force microscopy (AFM) results showed an increase in surface roughness for urethane (276%) and epoxy sized (78%) versus unsized TCF. XPS results showed 531% increase in O in epoxy sized TCF and 250% N content in urethane sized TCF compared to unsized TCF. The surface energy of epoxy and urethane sized TCF is enhanced by 78% and 96%, respectively compared to unsized TCF. The storage modulus showed improvement for urethane (23%) and epoxy (21%) sized than unsized TCF-TSU composites. The flexural, interlaminar shear strength (ILSS), and impact properties of urethane sized TCF increase by 24%, 50%, and 273%, respectively, than unsized TCF. The results demonstrate that the surface and thermal properties correlate with the mechanical properties of TCF-TSU composites and sizing enhances the wettability of the composites.

36 MATERIALS SCIENCE↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Rectifying Fluidic Diodes Based on Asymmetric Layer-by-Layer Nanofilms on Nanochannel Membranes

Nanochannel-based fluidic diodes display ion selectivity and ion-current rectification (ICR), which may prove important in energy harvesting and biosensors. This paper reports asymmetric functionalization of the outer surface of a flexible nanochannel polymer membrane to create fluidic diodes that give ICR. Layer-by-layer (LbL) adsorption with cross-linking of only the underlying part of the polyelectrolyte nanofilm leads to a porosity step across the film. The combination of a high effective surface-charge density and the porosity step in the film leads to a remarkable maximum ICR factor of ~200 with a pH gradient across the film. Incorporation of pH-sensitive polyelectrolyte components enables the ICR factor to increase an order of magnitude on going from pH 8 to pH 3. Furthermore, the coated membrane shows excellent anion-selectivity. Thus, LbL adsorption with partial cross-linking provides a simple method for creating coated nanochannel membranes that serve as pH-responsive ionic diodes for potential chemical/biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Textile-Grade Carbon Fiber-Reinforced Polycarbonate Composites: Effect of Epoxy Sizing

In this work, epoxy-sized textile-grade polyacrylonitrile (PAN) carbon fiber (TCF) with 450 K filaments (CFTF, ORNL) was reinforced in the polycarbonate (PC) matrix using a compression molding technique. The epoxy sizing effect on the surface, thermal, and mechanical properties of TCF–PC was investigated. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy results of the TCF–PC composite show the absence of an oxirane group (epoxy-sized TCF), which suggests a covalent bond formation between the oxirane ring and carbonyl groups from TCF and PC. Dynamic mechanical analysis results confirm a strong immobilized interface (b > 1) present between TCF and PC. The tensile, flexure, compression, and interlaminar shear strength of TCF–PC composites were 323 ± 53, 371 ± 31, 397 ± 87, and 36 ± 3 MPa, correspondingly. The fracture analysis through scanning electron microscopy shows good wettability between TCF and the PC matrix which validates the results obtained from surface and thermal characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗