Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

The 40 Ar(d,p) 41 Ar cross section between 3–7 MeV

To determine the safety of using argon as a deuteron beam stopping material, the 40 Ar(d,p) 41 Ar cross section was measured at average deuteron energies of 3.6 MeV, 5.5 MeV, and 7.0 MeV using an activation method. A 16-MeV deuteron beam produced by Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron was degraded to each energy by nickel foils and the front wall of an aluminum gas chamber. The reduced-energy deuterons were used to activate a sample of nat Ar gas. After each irradiation, the gas chamber’s 41 Ar activation was measured with a high-purity germanium detector. The cross sections measured were larger than a previous measurement by ~40%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmarking GEANT4 and PHITS for 14.8-MeV neutron transport in polyethylene and graphite materials

The feasibility of GEANT4 and PHITS with ENDF/B-VIII.0, JEFF-3.3 and JENDL-4.0 evaluated nuclear data libraries in 14.8-MeV neutron transport simulation are verified by comparing with the MCNP calculations and the experimental data. Here the measured data are from neutron integral experiments including graphite and polyethylene samples. For 6 cm-thick polyethylene and 20 cm-thick graphite samples, the results from GEANT4 and PHITS with three evaluated nuclear data libraries agree well with the MCNP calculations. For a 2 cm-thick graphite sample, the simulated results from GEANT4 and PHITS agree with the MCNP calculations, and they all underestimate the experiment data in below 3 MeV and overestimate them in the energy range of 5–7 MeV. The difference between the simulation results and the experimental data depends on the evaluated nuclear data libraries. In overall, GEANT4 and PHITS are performing reasonable jobs for 14.8-MeV neutron transport simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

Neutron elastic and inelastic cross section measurements on silicon from 0.8--8 MeV

Neutron elastic and inelastic scattering differential cross sections were measured at angles between 30° and 155° with incident neutron energies between 0.8 and 8 MeV. The measured differential scattering cross sections are compared to existing measurements and the ENDF/B-VIII.0, the JEFF-3.3, and the JENDL-4.0 data evaluations, as well as theoretical calculations from the TALYS-1.95 nuclear reaction code. Our results are reasonably well described by values from the ENDF/B-VIII.0 and JEFF-3.3 compilations. However, below 4 MeV, our backward-angle elastic scattering results tend to be lower than database/calculated values, suggesting that less recoil damage would occur than expected. Above 6 MeV, larger backward-angle cross sections are observed suggesting the opposite. Deexcitation γ rays produced in the inelastic scattering process were also studied for neutron energies between 1.9 and 4.5 MeV. Inelastic neutron scattering cross sections deduced from 28 Si(n,n1γ) γ-ray projection cross sections confirm our 28 Si(n,n1) results. To the extent that data from GELINA and our experimental results can be compared, we have excellent agreement between the inelastic neutron scattering cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Sub-MeV EMIC-Driven Trapped Electron Flux Dropouts From GPS Observations

We report that for many years, it was believed that resonant interactions between electromagnetic ion cyclotron (EMIC) waves and radiation belt electrons were restricted to electron energies >1–2 MeV. In recent years, however, a growing body of experimental evidence has shown that EMIC waves can cause the scattering loss of electrons down to sub-MeV energies. Using measurements of trapped electron flux from the Global Positioning System satellite constellation, we investigate the ability of EMIC waves to cause significant depletions of radiation belt electron populations between 4 ≤ L* ≤ 5. For the first time, we present statistical evidence demonstrating global decreases in sub-MeV trapped electron flux in response to EMIC wave activity. Although we find that electron losses extend down to sub-MeV energies, we also show strong statistical support for the ability of EMIC waves to preferentially cause substantial depletions of ultra-relativistic electrons in the radiation belts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on MeV dark matter and primordial black holes: Inverse Compton signals at the SKA

Here we investigate the possibilities for probing MeV dark matter (DM) particles and primordial black holes (PBHs) (for masses ~ 10 15 –10 17 g) at the upcoming radio telescope SKA, using photon signals from the Inverse Compton (IC) effect within a galactic halo. Pair-annihilation or decay of MeV DM particles (into e + e - pairs) or Hawking radiation from a population of PBHs generates mildly relativistic e ± which can lead to radio signals through the IC scattering on low energy cosmic microwave background (CMB) photons. We study the ability of SKA to detect such signals coming from nearby ultra-faint dwarf galaxies Segue I and Ursa Major II as well as the globular cluster ω-cen and the Coma cluster. We find that with ~ 100 hours of observation, the SKA improves the Planck constraints on the DM annihilation/decay rate and the PBH abundance for masses in the range ~ 1 to few tens of MeV and above 10 15 to 10 17 g, respectively. Importantly, the SKA limits are independent of the assumed magnetic fields within the galaxies. Previously allowed regions of diffusion parameters of MeV electrons inside a dwarf galaxy that give rise to observable signals at the SKA are also excluded. For objects like dwarf galaxies, predicted SKA constraints depend on both the DM and diffusion parameters. Independent observations in different frequency bands, e.g., radio and γ-ray frequencies, may break this degeneracy and thus enable one to constrain the combined parameter space of DM and diffusion. However, the constraints are independent of diffusion parameters for galaxy clusters such as Coma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonmonotonic-potential description of polarization effects, fusion, and nuclear rainbows in elastic scattering of 6 Li + 12 C at 4.5–600 MeV

The experimental differential cross-section (CS) and analyzing power (AP) data of the 6 Li + 12 C elastic scattering over a wide laboratory energy scale (4.5MeV≤𝐸 lab ≤600MeV) are analyzed within the framework of the optical model (OPM) using nonmonotonic (NM) nucleus–nucleus potentials. The real part of the NM potentials is derived from the Pauli-embodied energy density-functional (EDF) formalism with the sudden approximation. The real part of the noncentral spin-orbit and tensor terms, as well as the imaginary parts, are treated phenomenologically. The effect of the radius of sensitivity on the CS and AP data is found to be more important at lower energies. The diffractive and refractive scattering with Airy structures in the whole angular region of the elastic scattering across the studied energy range is successfully described within the OPM using the NM 6 Li + 12 C potential. The near- and far-side (N and F) decomposition of the total elastic-scattering amplitudes has also been studied using our NM potentials. The evolution of the Airy minima in the angular distributions, coupled with the fitting of the AP data, provides an accurate description of Airy minima of different orders. The OPM calculations with the NM potentials describe exceptionally well the CS, vector analyzing power (VAP), and tensor analyzing power data at 𝐸 lab =9.0,19.24,20,30, and 50MeV. In agreement with our past successful descriptions of CS and the opposite signs of the VAP data for the 6 Li and 7 Li elastic scattering using NM potentials in OPM, the present results appear to provide a better fit, so far, than those obtained from the coupled-channels method. The fusion cross sections of 6 Li + 12 C have been predicted in the energy range (4.5MeV≤𝐸 lab ≤20MeV), fitting the experimental data well in the range 𝐸 lab =2.97–11.77MeV. The EDF potential without any energy dependence and renormalization is also found to describe satisfactorily the experimental CS and AP data at energies up to several hundreds of MeV.

6 ≤ A ≤ 19↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Mini Astrophysical MeV Background Observatory (MAMBO) CubeSat mission

The origin of the cosmic diffuse gamma-ray (CDG) background in the 0.3 – 30 MeV energy range is a mystery that has persisted for over 40 years. The Mini Astrophysical MeV Background Observatory (MAMBO) is a CubeSat mission concept motivated by the fact that, since the MeV CDG is relatively bright, only a small detector is required to make highquality measurements of it. Indeed, the sensitivity of space-based gamma-ray instruments to the CDG is limited not by size, but by the locally generated instrumental background produced by interactions of energetic particles in spacecraft materials. Comparatively tiny CubeSat platforms provide a uniquely quiet environment relative to previous gamma-ray science missions. The MAMBO mission will provide the best measurements ever made of the MeV CDG spectrum and angular distribution, utilizing two key innovations: 1) low instrumental background on a 12U CubeSat platform; and 2) an innovative shielded spectrometer design that simultaneously measures signal and background. We describe the MAMBO instrument and mission concept in detail, including simulations and laboratory measurements demonstrating the key measurement concept.

Astronomy and astrophysics↗

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of 208-Tl decays

A proper understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in LArTPCs. This poster will present an analysis resulting in the first-ever demonstration of LArTPC energy resolution in the MeV regime. A measurement of the resolution of energy reconstruction in the MicroBooNE LArTPC at ~1.5 MeV was performed using monoenergetic signals generated by 208Tl decay gamma-rays pair-producing in the detector. This study provides a pathway for MeV-scale monoenergetic energy calibrations in future LArTPC experiments.

Manuel Alves, Maria Gabriela [IIT, Chicago] (ORCID↗

MeV Gamma Rays from Fission: A Distinct Signature of Actinide Production in Neutron Star Mergers

Neutron star mergers (NSMs) are the first verified sites of rapid neutron capture (r-process) nucleosynthesis, and could emit gamma rays from the radioactive isotopes synthesized in the neutron-rich ejecta. These MeV gamma rays may provide a unique and direct probe of the NSM environment as well as insight into the nature of the r process, just as observed gammas from the 56 Ni radioactive decay chain provide a window into supernova nucleosynthesis. In this work, we include the photons from fission processes for the first time in estimates of the MeV gamma-ray signal expected from an NSM event. We consider NSM ejecta compositions with a range of neutron richness and find a dramatic difference in the predicted signal depending on whether or not fissioning nuclei are produced. The difference is most striking at photon energies above ~3.5 MeV and at a relatively late time, several days after the merger event, when the ejecta is optically thin. We estimate that a Galactic NSM could be detectable by a next generation gamma-ray detector such as AMEGO in the MeV range, up to ~104 days after the merger, if fissioning nuclei are robustly produced in the event.

79 ASTRONOMY AND ASTROPHYSICS↗