Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Novel miniaturised wideband baluns for MIC and MMIC applications

Very compact novel planar broadband baluns are described. Each balun consists of two Lange couplers. Less than 0.3 dB and 2.5 deg for the amplitude and phase balances, respectively, have been measured over the 1.0-2.2 GHz bandwidth for a microstrip balun. As compared with other reported baluns, these baluns are simpler, more compact, easier to design, and fabricated on only one side of the substrate. They are thus very attractive for microwave integrated and monolithic integrated circuit applications.

Nguyen, C.↗

Stability of Non-Neutral Plasma Cylinder Consisting of Magnetized Cold Electrons and of Small Density Fraction of Ions Born at Rest: Non-Local Analysis

The non-local stability problem of the plasma cylinder, filled with 'cold' magnetized rigidly rotating electrons, and a small density fraction of ions, is solved. The ions are supposed to be born at rest by ionization of background gas. The study is based on the kinetic description of ions. The equilibrium distribution function, taking into account the peculiarity of ions birth, is used. The radial electric field is caused by space charge of non-neutral plasma. The dispersion equation for plasma eigen frequencies is obtained analytically. It is valid within the total admissible range of values of electric and magnetic fields. Normalized eigen frequencies {omega}'/{omega}{sub i} are calculated for the basic azimuth mode m = 1({omega}' {omega}-m{omega}{sub i}{sup +}, {omega}{sub +} = (-{omega}{sub ci}+{omega}{sub i})/2, {omega}{sub i} ({omega}{sub ci}{sup 2}-4eE{sub r}/m{sub i}r){sup 1/2} is called the 'modified' ion cyclotron (MIC) frequency), for the density fraction of ions of atomic nitrogen f N{sub i}/n{sub e} = 0,01 and are presented in graphic form versus parameter 2{omega}{sub pe}{sup 2}/{omega}{sub ce}{sup 2}. The spectra of oscillations {omega}'/{omega}{sub i} consist of the family of electron Trivel-piece--Gould (TG) modes and of the families of MIC modes. The frequencies of MIC modes are located in a small vicinity of harmonics of the MIC frequency {omega}{sub i} above and below the harmonic. The TG modes in non-neutral plasma fall in the region of MIC frequencies {omega}{sub i} and interact strongly with MIC modes. The slow TG modes become unstable near the crossings with non-negative harmonics of MIC frequencies. The instabilities have a resonant character. The lowest radial TG mode has a maximum growth rate at crossing with a zero harmonic of {omega}{sub i} ((Im {omega}'/{omega}{sub i}){sub max}{approx_equal}0,074). The growth rates of MIC modes are much lower ((Im {omega}'/{omega}{sub i}){sub max} < or approx. 0,002). Their instability has a threshold character. The instabilities of TG and MIC modes take place mainly at the values of parameter 2{omega}{sub pe}{sup 2}/{omega}{sub ce}{sup 2}, corresponding to strong radial electric fields ({omega}{sub ci}{sup 2}<<|eE{sub r}/m{sub i}r|), in which the ions are unmagnetized. The oscillations of small amplitude are seen on some frequency dependencies of MIC modes. They are similar to oscillations on dispersion curves of electron waves in metals and are caused by the similarity between the ion equilibrium distribution function and the degenerate Fermi--Dirac one. The results obtained give the solution to the stability problem discussed by R.H. Levy, J.D. Daugherty and O. Buneman [Phys. Fl. 12, 2616-2629 (1969)] for a special case of plasma bounding directly with metal casing and possessing the volumetric eigen modes only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solvent-Cast Solid Electrolyte Membranes Based on a Charged Rigid-Rod Polymer and Ionic Liquids

Solid-state electrolytes are attractive for use in electrochemical devices because they remove the need for a flammable liquid electrolyte while contributing to the structural integrity of the device. We have recently developed a class of solid electrolytes, termed molecular ionic composites (MICs), composed of ionic liquids (ILs) and a rigid-rod polyelectrolyte, poly(2,2'-disulfonyl-4,4'-benzidine terephthalamide) (PBDT). MIC materials, originally obtained through an ion-exchange process between IL and PBDT aqueous solution, possess an unprecedented combination of high ionic conductivity, high thermal stability, low flammability and widely tunable tensile storage moduli. Here we present a facile solvent casting method for preparing MIC membranes. These membranes are uniform, flexible, and tough, with tunable composition and thickness (≥ 40 μm). Unlike the previous ion-exchange method, which only allowed incorporation of hydrophilic ILs, we can now incorporate hydrophobic ILs to prepare MIC membranes for, e.g. battery electrolytes. A sodium (Na) metal symmetric cell constructed with a PBDT-Pyr 14 TFSI membrane as the solid electrolyte shows long-term stable cycling (> 500 h.) at 60 °C. Furthermore, the ability to prepare MICs using both hydrophilic and hydrophobic ILs initiates a wider range of MIC materials and broadens the array of applications accessible by MIC membranes.

25 ENERGY STORAGE↗

Delayed Gamma Measurements in Different Nuclear Research Reactors Bringing Out the Importance of the Delayed Contribution in Gamma Flux Calculations

Neutron and gamma flux levels are key parameters in nuclear research reactors. In Material Testing Reactors, such as the future Jules Horowitz Reactor, under construction at the French Alternative Energies and Atomic Energy Commission (CEA Cadarache, France), the expected gamma flux levels are very high (nuclear heating is of the order of 20 W/g at 100 MWth). As gamma rays deposit their energy in the reactor structures and structural materials it is important to take them into account when designing irradiation devices. There are only a few sensors which allow measurements of the nuclear heating ; a recent development at the CEA Cadarache allows measurements of the gamma flux using a miniature ionization chamber (MIC). The measured MIC response is often compared with calculation using modern Monte Carlo (MC) neutron and photon transport codes, such as TRIPOLI-4 and MCNP6. In these calculations only the production of prompt gamma rays in the reactor is usually modelled thus neglecting the delayed gamma rays. Hence calculations and measurements are usually in better accordance for the neutron flux than for the gamma flux. In this paper we study the contribution of delayed gamma rays to the total MIC signal in order to estimate the systematic error in gamma flux MC calculations. In order to experimentally determine the delayed gamma flux contributions to the MIC response, we performed gamma flux measurements with CEA developed MIC at three different research reactors: the OSIRIS reactor (MTR - 70 MWth at CEA Saclay, France), the TRIGA MARK II reactor (TRIGA - 250 kWth at the Jozef Stefan Institute, Slovenia) and the MARIA reactor (MTR - 30 MWth at the National Center for Nuclear Research, Poland). In order to experimentally assess the delayed gamma flux contribution to the total gamma flux, several reactor shut down (scram) experiments were performed specifically for the purpose of the measurements. Results show that on average about 30 % of the MIC signal is due to the delayed gamma rays. In this paper we describe experiments in each of the three reactors and how we estimate delayed gamma rays with MIC measurements. The results and perspectives are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oscillation spectrum of an electron gas with a small density fraction of ions

The problem is solved of the stability of a nonneutral plasma that completely fills a waveguide and consists of magnetized cold electrons and a small density fraction of ions produced by ionization of the atoms of the background gas. The ions are described by an anisotropic distribution function that takes into account the characteristic features of their production in crossed electric and magnetic fields. By solving a set of Vlasov-Poisson equations analytically, a dispersion equation is obtained that is valid over the entire range of allowable electric and magnetic field strengths. The solutions to the dispersion equation for the m = +1 main azimuthal mode are found numerically. The plasma oscillation spectrum consists of the families of Trivelpiece-Gould modes at frequencies equal to the frequencies of oblique Langmuir oscillations Doppler shifted by the electron rotation and also of the families of 'modified' ion cyclotron (MIC) modes at frequencies close to the harmonics of the MIC frequency (the frequencies of radial ion oscillations in crossed fields). It is shown that, over a wide range of electric and magnetic field strengths, Trivelpiece-Gould modes have low frequencies and interact with MIC modes. Trivelpiece-Gould modes at frequencies close to the harmonics of the MIC frequency with nonnegative numbers are unstable. The lowest radial Trivelpiece-Gould mode at a frequency close to the zeroth harmonic of the MIC frequency has the fastest growth rate. MIC modes are unstable over a wide range of electric and magnetic field strengths and grow at far slower rates. For a low ion density, a simplified dispersion equation is derived perturbatively that accounts for the nonlocal ion contribution, but, at the same time, has the form of a local dispersion equation for a plasma with a transverse current and anisotropic ions. The solutions to the simplified dispersion equation are obtained analytically. The growth rates of the Trivelpiece-Gould modes and the behavior of the MIC modes agree with those obtained by numerical simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transit Timing Variations for AU Microscopii b and c

We explore the transit timing variations (TTVs) of the young (22 Myr) nearby AU Mic planetary system. For AU Mic b, we introduce three Spitzer (4.5 μm) transits, five TESS transits, 11 LCO transits, one PEST transit, one Brierfield transit, and two transit timing measurements from Rossiter–McLaughlin observations; for AU Mic c, we introduce three TESS transits. We present two independent TTV analyses. First, we use EXOFASTv2 to jointly model the Spitzer and ground-based transits and obtain the midpoint transit times. We then construct an O − C diagram and model the TTVs with Exo-Striker. Second, we reproduce our results with an independent photodynamical analysis. We recover a TTV mass for AU Mic c of -10.8+2.22.3 M⊕. We compare the TTV-derived constraints to a recent radial velocity (RV) mass determination. We also observe excess TTVs that do not appear to be consistent with the dynamical interactions of b and c alone or due to spots or flares. Thus, we present a hypothetical nontransiting “middle-d” candidate exoplanet that is consistent with the observed TTVs and candidate RV signal and would establish the AU Mic system as a compact resonant multiplanet chain in a 4:6:9 period commensurability. These results demonstrate that the AU Mic planetary system is dynamically interacting, producing detectable TTVs, and the implied orbital dynamics may inform the formation mechanisms for this young system. We recommend future RV and TTV observations of AU Mic b and c to further constrain the masses and confirm the existence of possible additional planet(s).

Justin M Wittrock↗

Subinhibitory Concentrations of Amoxicillin, Lincomycin, and Oxytetracycline Commonly Used to Treat Swine Increase Streptococcus suis Biofilm Formation

Streptococcus suis is a bacterial swine pathogen with a significant economic burden. It typically colonizes the tonsil and nasal cavity of swine causing a variety of symptoms ranging from asymptomatic carriage to lethal systemic disease. A key barrier toward the development of improved vaccines or interventions for S. suis infections is a gap in our understanding of the mechanisms contributing to persistence in the host, in which colonized pigs continue to shed and transmit S. suis . We hypothesized that exposure to sub-MICs of antibiotics commonly used by the swine industry would increase the biofilm capacity of S. suis strains. Using a 96-well plate MIC protocol, we experimentally determined the MIC for each of 12 antibiotics for a virulent strain of S. suis strain that consistently formed biofilms using a standard crystal violet assay. Using this static biofilm assay, we demonstrated that sub-MICs of bacitracin, carbadox, chlortetracycline, enrofloxacin, gentamicin, neomycin, sulfadimethoxine, tiamulin, and tylosin did not increase S. suis biofilms. In contrast, we demonstrated that sub-MICs of amoxicillin, lincomycin, and oxytetracycline increased overall biofilm formation under both static and flow conditions. The biofilm formation of 11 additional clinical isolates were measured using the relevant concentrations of amoxicillin, lincomycin, and oxytetracycline. Here, eight of the eleven strains increased the biofilm formation with lincomycin, seven with amoxicillin, and three with oxytetracycline. Collectively, our data demonstrate that exposure to sub-MICs of these commonly used antibiotics contributes to increased biofilm formation of S. suis , thereby potentially increasing survival and persistence within the respiratory tract of swine.

59 BASIC BIOLOGICAL SCIENCES↗

Fault Diagnosis of Hybrid Computing Systems Using Chaotic-Map Method

Computing systems are becoming increasingly complex with nodes consisting of a combination of multi-core central processing units (CPUs), many integrated core (MIC) and graphics processing unit (GPU) accelerators. These computing units and their interconnections are subject to different classes of hardware and software faults, which should be detected to support mitigation measures. We present the chaotic-map method that uses the exponential divergence and wide Fourier properties of the trajectories, combined with memory allocations and assignments to diagnose component-level faults in these hybrid computing systems. We propose lightweight codes that utilize highly parallel chaotic-map computations tailored to isolate faults in arithmetic units, memory elements and interconnects. The diagnosis module on a node utilizes pthreads to place chaotic-map threads on CPU and MIC cores, and CUDA C and OpenCL kernels on GPU blocks. We present experimental diagnosis results on five multi-core CPUs; one MIC; and, seven GPUs with typical diagnosis run-times under a minute.

Rao, Nageswara↗

Room Temperature to 150 °C Lithium Metal Batteries Enabled by a Rigid Molecular Ionic Composite Electrolyte

Molecular ionic composites (MICs), made from ionic liquids and a rigid-rod polymer poly(2,2'-disulfonyl-4,4'-benzidine terephthalamide) (PBDT), are a new type of rigid gel electrolyte that combine fast ion transport with high thermal stability and mechanical strength. In this work, a MIC electrolyte membrane is prepared that is composed of PBDT, lithium bis(trifluoromethylsulfonyl)imide (LiTFSI), and 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide (Pyr 14 TFSI) in a mass ratio of 10:10:80. The ionic conductivity at 25 °C is 0.56 mS cm –1 with no added flammable/volatile components. Although the polymer content is only 10 wt%, this MIC membrane is rigid with a tensile modulus of 410 MPa at room temperature. The MIC membrane remains stable and rigid at 200 °C with the shear storage modulus (G') only slightly decreasing by 35%. Li/MIC/LiFePO 4 cells demonstrate stable cycling performance over a wide temperature range from 23 to 150 °C. The specific discharge capacity at 100 and 150 °C at 1 C rate exceeds 160 mAh g –1 . The discharge capacity retention is 99% after 50 cycles at 150 °C. Furthermore, this stable battery performance shows that this low polymer content MIC membrane qualifies for use as a solid electrolyte in lithium metal batteries operating over a wide temperature range.

25 ENERGY STORAGE↗

Novel short antibacterial and antifungal peptides with low cytotoxicity: Efficacy and action mechanisms

Research highlights: {yields} Short antimicrobial peptides with nine and eleven residues were developed. {yields} These peptides show strong bactericidal activity against clinically important bacterial and fungal pathogens. {yields} These peptides exhibit high stability in the presence of salts, and low cytotoxicity. {yields} These peptides exert their action by disrupting membrane lipids. -- Abstract: Short antimicrobial peptides with nine and eleven residues were developed against several clinically important bacterial and fungal pathogens (specifically Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Fusarium solani). Twelve analogues of previously reported peptides BP76 (KKLFKKILKFL) and Pac-525 (KWRRWVRWI) were designed, synthesized, and tested for their antimicrobial activities. Two of our eleven amino acid peptides, P11-5 (GKLFKKILKIL) and P11-6 (KKLIKKILKIL), have very low MICs of 3.1-12.5 {mu}g ml{sup -1} against all five pathogens. The MICs of these two peptides against S. aureus, C. albicans and F. solani are four to ten times lower than the corresponding MICs of the reference peptide BP76. P9-4 (KWRRWIRWL), our newly designed nine-amino acid analogue, also has particularly low MICs of 3.1-6.2 {mu}g ml{sup -1} against four of the tested pathogens; these MICs are two to eight times lower than those reported for Pac-525 (6.2-50 {mu}g ml{sup -1}).These new peptides (P11-5, P11-6 and P9-4) also exhibit improved stability in the presence of salts, and have low cytotoxicity as shown by the hemolysis and MTT assays. From the results of field-emission scanning electron microscopy, membrane depolarization and dye-leakage assays, we propose that these peptides exert their action by disrupting membrane lipids. Molecular dynamics simulation studies confirm that P11-6 peptide maintains relatively stable helical structure and exerts more perturbation action on the order of acyl tail of lipid bilayer.

60 APPLIED LIFE SCIENCES↗

High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

14 SOLAR ENERGY↗

A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

14 SOLAR ENERGY↗

Developing an in silico minimum inhibitory concentration panel test for Klebsiella pneumoniae

Here, antimicrobial resistant infections are a serious public health threat worldwide. Whole genome sequencing approaches to rapidly identify pathogens and predict antibiotic resistance phenotypes are becoming more feasible and may offer a way to reduce clinical test turnaround times compared to conventional culture-based methods, and in turn, improve patient outcomes. In this study, we use whole genome sequence data from 1668 clinical isolates of Klebsiella pneumoniae to develop a XGBoost-based machine learning model that accurately predicts minimum inhibitory concentrations (MICs) for 20 antibiotics. The overall accuracy of the model, within ± 1 two-fold dilution factor, is 92%. Individual accuracies are >= 90% for 15/20 antibiotics. We show that the MICs predicted by the model correlate with known antimicrobial resistance genes. Importantly, the genome-wide approach described in this study offers a way to predict MICs for isolates without knowledge of the underlying gene content. This study shows that machine learning can be used to build a complete in silico MIC prediction panel for K. pneumoniae and provides a framework for building MIC prediction models for other pathogenic bacteria.

60 APPLIED LIFE SCIENCES↗