Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Millimeter Wave Synthetic Aperture Imaging System with a Unique Rotary Scanning System

In recent years, millimeter wave imaging techniques, using synthetic aperture focusing and holographical approaches, have shown tremendous potential for nondestructive testing applications, involving materials and structures used in space vehicles, including the space shuttle external fuel tank spray on foam insulation and its acreage heat tiles. The ability of signals at millimeter wave frequencies (30 - 300 GHz) to easily penetrate inside of low loss dielectric materials, their relatively small wavelengths, and the possibility of detecting coherent (magnitude and phase) reflections make them suitable for high resolution synthetic aperture focused imaging the interior of such materials and structures. To accommodate imaging requirements, commonly a scanning system is employed that provides for a raster scan of the desired structure. However, most such scanners, although simple in design and construction, are inherently slow primarily due to the need to stop and start at the beginning and end of each scan line. To this end, a millimeter wave synthetic aperture focusing system including a custom-designed transceiver operating at 35 - 45 GHz (Q-band) and unique and complex rotary scanner was designed and developed. The rotary scanner is capable of scanning an area with approximately 80 cm in diameter in less than 10 minutes at step sizes of 3 mm and smaller. The transceiver is capable of producing accurate magnitude and phase of reflected signal from the structure under test. Finally, a synthetic aperture focusing algorithm was developed that translates this rotary-obtained magnitude and phase into a synthetic aperture focusing image of inspected structures. This paper presents the design of the transceiver and the rotary scanning system along with showing several images obtained with this system from various complicated structures.

Ghasr, M. T.↗

Design optimization of sinusoidal glass honeycomb for flat plate solar collectors

The design of honeycomb made of sinusoidally corrugated glass strips was optimized for use in water-cooled, single-glazed flat plate solar collectors with non-selective black absorbers. Cell diameter (d), cell height (L), and pitch/diameter ratio (P/d) maximizing solar collector performance and cost effectiveness for given cell wall thickness (t sub w) and optical properties of glass were determined from radiative and convective honeycomb characteristics and collector performance all calculated with experimentally validated algorithms. Relative lifetime values were estimated from present materials costs and postulated production methods for corrugated glass honeycomb cover assemblies. A honeycomb with P/d = 1.05, d = 17.4 mm, L = 146 mm and t sub w = 0.15 mm would provide near-optimal performance over the range delta T sub C greater than or equal to 0 C and less than or equal to 80 C and be superior in performance and cost effectiveness to a non-honeycomb collector with a 0.92/0.12 selective black absorber.

Mcmurrin, J. C.↗

Data acquisition and path selection decision making for an autonomous roving vehicle

The feasibility of using range/pointing angle data such as might be obtained by a laser rangefinder for the purpose of terrain evaluation in the 10-40 meter range on which to base the guidance of an autonomous rover was investigated. The decision procedure of the rapid estimation scheme for the detection of discrete obstacles has been modified to reinforce the detection ability. With the introduction of the logarithmic scanning scheme and obstacle identification scheme, previously developed algorithms are combined to demonstrate the overall performance of the intergrated route designation system using laser rangefinder. In an attempt to cover a greater range, 30 m to 100 mm, the problem estimating gradients in the presence of positioning angle noise at middle range is investigated.

Shen, C. N.↗

Ground-based microwave monitoring of stratospheric ozone

A microwave instrument developed for operational measurements of ozone for the Network for Detection of Stratospheric Change is discussed. The instrument observes two spectral lines near 3-mm wavelength with a bandwidth of 630 MHz, allowing profile retrieval from 20 to 70 km. The observing technique and calibration procedures are described. The measurement forward model and retrieval algorithm are formulated. Preliminary comparisons with a colocated ground-based lidar and the SAGE II instrument are presented. The measurements are shown to typically agree to within 5 to 10 percent.

Parrish, A.↗

An implementation of a chemical and thermal nonequilibrium flow solver on unstructured meshes and application to blunt bodies

This paper presents a nonequilibrium flow solver, implementation of the algorithm on unstructured meshes, and application to hypersonic flow past blunt bodies. Air is modeled as a mixture of five chemical species, namely O2, N2, O, NO, and N, having two temperatures namely translational and vibrational. The solution algorithm is a cell centered, point implicit upwind scheme that employs Roe's flux difference splitting technique. Implementation of this algorithm on unstructured meshes is described. The computer code is applied to solve Mach 15 flow with and without a Type IV shock interference on a cylindrical body of 2.5mm radius representing a cowl lip. Adaptively generated meshes are employed, and the meshes are refined several times until the solution exhibits detailed flow features and surface pressure and heat flux distributions. Effects of a catalytic wall on surface heat flux distribution are studied. For the Mach 15 Type IV shock interference flow, present results showed a peak heat flux of 544 MW/m2 for a fully catalytic wall and 431 MW/m(exp 2) for a noncatalytic wall. Some of the results are compared with available computational data.

Prabhu, Ramadas K.↗

Quantifying Water Storage Change and Land Subsidence Induced by Reservoir Impoundment Using GRACE, Landsat, and GPS Data

The construction of hydropower dams is a common strategy to support a country's increasing need for electricity and river water management for industry and agriculture. Although the hydrological and geophysical impacts of water relocation are usually assessed prior to impoundment, their accuracy is generally limited due to the lack of in situ observations, especially in a remote area. This study presents a workflow to quantify the terrestrial water storage change (TWS) and land subsidence induced by a reservoir's water impoundment using multiple satellite observations (GRACE, Landsat), land surface models (CABLE, GLDAS, NCEP, ECMWF), and GPS data. The study site is the Bakun Dam, located in Sarawak, Malaysia, which is the largest hydropower dam in Southeast Asia. Commencing operation in late 2010, the dam induced a change of water mass and lake surface area that was clearly observed by GRACE and Landsat observations, respectively. During the 17-month impounding period (from August 2010 to December 2011), GRACE observed a dramatic increase of approximately 200 mm equivalent water height, while Landsat detected an increased lake extent of around 600 km2. In this paper, a forward model is developed to determine the increased water surface level corresponding to GRACE observations, estimated to be about 120 m. In contrast to GRACE, the TWS derived from land surface models cannot capture the increased TWS, due to the lack of reservoir routing algorithms in the models. In addition, the land subsidence was calculated using the disk load model constructed based on the GRACE-derived lake level and Landsat-derived lake extent; the result is validated with the GPS data from BIN1 station, located at the western coast of Borneo. The commencement stage of the Bakun Dam induces the large-scale land subsidence, which causes the GPS-BIN1 station to subside by ~9 mm, and move toward the Bakun Lake by ~4 mm. Computation of the surface displacements directly from GRACE spherical harmonic coefficient data fails to capture the subsidence feature, mainly due to the truncation error. Overall, this study demonstrates that evaluating GRACE in conjunction with Landsat, LSMs, and GPS data allows the exploitation of the gravity signal at a much smaller spatial scale than its intrinsic resolution. Benefiting from global coverage, the newly developed satellite-based algorithm is a valuable tool for assessing the impacts of reservoir operation on hydrological and geophysical changes from local to regional scales.

Natthachet Tangdamrongsub↗

Validation of a New NIRS Method for Measuring Muscle Oxygenation During Rhythmic Handgrip Exercise

Near infrared spectroscopy (NIRS) is commonly used to measure muscle oxygenation during exercise and recovery. Current NIRS algorithms do not account for variation in water content and optical pathlength during exercise. The current effort attempts to validate a newly developed NIRS algorithm during rhythmic handgrip exercise and recovery. Six female subjects, aver age 28 +/- 6 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space. A NIRS sensor with 30 mm source-detector separation was placed on the flexor digitorum profundus. Subjects performed two 5-min bouts of rhythmic handgrip exercise (2 s contraction/1 s relaxation) at 15% and 30% of maximal voluntary contraction. Venous blood was sampled before each bout, during the last minute of exercise, and after 5 minutes of recovery. Venous oxygen saturation (SvO2) was measured with a I-stat CG-4+ cartridge. Spectra were collected between 700-900 nm. A modified Beer's Law formula was used to calculate the absolute concentration of oxyhemoglobin (HbO2), deoxyhemoglobin (Hb) and water, as well as effective pathlength for each spectrum. Muscle oxygen saturation (SmO2) was calculated from the HbO2 and Hb results. The correlation between SvO2 and SmO2 was determined. Optical pathlength and water varied significantly during each exercise bout, with pathlength increasing approximately 20% and water increasing about 2%. R2 between blood and muscle SO2 was found to be 0.74, the figure shows the relationship over SvO2 values between 22% and 82%. The NIRS measurement was, on average, 6% lower than the blood measurement. It was concluded that pathlength changes during exercise because muscle contraction causes variation in optical scattering. Water concentration also changes, but only slightly. A new NIRS algorithm which accounts for exercise-induced variation in water and pathlength provided an accurate assessment of muscle oxygen saturation before, during and after exercise.

Hagan, R. Donald↗

Interannual Variability of Tropical Ocean Evaporation: A Comparison of Microwave Satellite and Assimilation Results

Remote sensing methodologies for turbulent heat fluxes over oceans depend on driving bulk formulations of fluxes with measured surface winds and estimated near surface thermodynamics from microwave sensors of the Special Sensor Microwave Imager (SSM/I) heritage. We will review recent work with a number of SSM/I-based algorithms and investigate the ability of current data sets to document global, tropical ocean-averaged evaporation changes in association with El Nino and La Nina SST changes. We show that in addition to interannual signals, latent heat flux increases over the period since late 1987 range from approx. .1 to .6 mm/ day are present; these represent trends 2 to 3 times larger than the NCEP Reanalysis. Since atmospheric storage cannot account for the difference, and since compensating evapotranspiration changes over land are highly unlikely to be this large, these evaporation estimates cannot be reconciled with ocean precipitation records such as those produced by the Global Precipitation Climatology Project, GPCP. The reasons for the disagreement include less than adequate intercalibration between SSM/I sensors providing winds and water vapor for driving the algorithms, biases due to the assumption that column integrated water vapor mirrors near surface water vapor variations, and other factors as well. The reanalyses have their own problems with spin-up during assimilation, lack of constraining input data at the ocean surface, and amplitude of synoptic transients.

Robertson, Franklin R.↗

Concentration Measurements in Self-Excited Momentum Dominated Low-Density Gas Jets

Flow structure of self-excited, laminar, axisymmetric, momentum-dominated helium jets discharged vertically into ambient air was investigated using high-speed rainbow schlieren deflectometry technique. Measurements were obtained at temporal resolution of 1 ms and spatial resolution of 0.19 mm for two test cases with Richardson number of 0.034 and 0.018. Power spectra revealed that the oscillation frequency was independent of spatial coordinates, suggesting global oscillations in the flow. Abel inversion algorithm was used to reconstruct the concentration field of helium. Instantaneous concentration contours revealed changes in the flow field and evolution of vortical structures during an oscillation cycle. Temporal evolution plots of helium concentration at different axial locations provided detailed information about the instability in the flow field.

Yildirim, B. S.↗

A Portable Electronic Nose For Hydrazine and Monomethyl Hydrazine Detection

The Space Program and military use large quantities Hydrazine (Hz) and monomethyl hydrazine (MMI-I) as rocket propellant. These substances are very toxic and are suspected human carcinogens. The American Conference of Governmental Industrial Hygienist set the threshold limit value to be 10 parts per billion (ppb). Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect 10 ppb concentration. This shortcofriing is not acceptable for many operations. A new prototype instrument using a gas sensor array and pattern recognition software technology (i.e., an electronic nose) has demonstrated the ability to identify either Hz or MM}{ and quantify their concentrations at 10 parts per billion in 90 seconds. This paper describes the design of the portable electronic nose (e-nose) instrument, test equipment setup, test protocol, pattern recognition algorithm, concentration estimation method, and laboratory test results.

Young, Rebecca C.↗

Revision of the Atmospheric Delay Correction for ICESat-2 Laser Altimeter Ranges

In 2001 Herring and Quinn proposed the algorithm for correction for atmospheric delay to ICESat-1 GLAS laser altimeter. The purpose of this document is to provide a revision of the algorithm suitable for processing the data from ICESat-2 mission scheduled for launch in 2016. The goal of the revision is to provide a procedure for atmospheric delay correction that would be precise to 1 mm level. The actual accuracy of delay computation will be somewhat less, but it will be limited only by imperfection of the used numerical weather model.

GLAS↗

A 3D Citizen Science Video Game for NeMO-Net, the NASA Neural Multi-Modal Observation and Training Network for Global Coral Reef Assessment

NeMO-Net, the NASA neural multi-modal observation and training network for global coral reef assessment, is an open-source deep convolutional neural network aimed at accurately assessing the present and past dynamics of coral reef ecosystems through determination of percent living cover and morphology. We present here the active learning component of the project, which consists of an interactive video game prototype for tablet and mobile devices where players are able to intuitively label morphology classifications over mm-scale 3D coral reef imagery. Active learning applications present a novel methodology for engaging the public while efficiently providing large-scale training and test data for increasingly complex and data-intensive machine learning algorithms. NeMO-Net trains players on domain-specific knowledge through interactive tutorials and periodically checks players' input against pre-classified coral imagery to gauge their accuracy and utilize in-game mechanics to provide personalized classification training. Players can rate the classifications of other players, unlock rewards and join a global community as they explore and classify coral reefs and other shallow marine environments.

Citizen Science↗

Large aperture high accuracy satellite laser tracking

A satellite laser ranging station has been established in order to range both low and high earth-orbiting satellites with a few-mm accuracy; this entails precision pointing of a 15-ton, azimuth-elevation-mounted coude telescope. Because tracking is performed under open loop computer control with no feedback from laser returns, the initial acquisition data and the algorithms for orbit computation must be accurate enough to maintain the satellite within the narrow laser beam width. The system is currently being used to track the LAGEOS and STARLETTE satellites.

Mcgarry, Jan L. F.↗

A Guideline for the Management of Renal Stones in Astronauts

There are no specific guidelines for the management of renal stones in astronauts. Given the increased risk for bone loss, hypercalcuria, and stone formation due to microgravity, a clinical practice guideline is needed. Methods An extensive review of the literature and current aeromedical standards for the management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. This information was used to create an algorithm for the management of renal stones in astronauts. Results Guidelines are proposed based on accepted standards of care, with consideration to the environment of spaceflight. In a usual medical setting, asymptomatic, small stones less than 7 mm are often observed over time. Given the constraints of schedule, and the risks to crew health and mission, this approach is too liberal. An upper limit of 3 mm stone diameter was adopted before requiring intervention, because this is the largest size that has a significant chance of spontaneous passage on its own. Other specific guidelines were also created. Discussion The spaceflight environment requires more aggressive treatment than would otherwise be found with the usual practice of medicine. A small stone can become a major problem because it may ultimately require medical evacuation from orbit. Thus renal stones are a significant mission threat and should be managed in a systematic way to mitigate risks to crew health and mission success.

Reyes, David↗

Real time thermal imaging for analysis and control of crystal growth by the Czochralski technique

A real time thermal imaging system with temperature resolution better than +/- 0.5 C and spatial resolution of better than 0.5 mm has been developed. It has been applied to the analysis of melt surface thermal field distributions in both Czochralski and liquid encapsulated Czochralski growth configurations. The sensor can provide single/multiple point thermal information; a multi-pixel averaging algorithm has been developed which permits localized, low noise sensing and display of optical intensity variations at any location in the hot zone as a function of time. Temperature distributions are measured by extraction of data along a user selectable linear pixel array and are simultaneously displayed, as a graphic overlay, on the thermal image.

Wargo, M. J.↗

Development of a mobile satellite communication unit

A compact 210(W) x 280(H) x 330(D) mm mobile terminal capable of transmitting voice and data through L-band mobile satellites is described. The Voice Codec can convert an analog voice to or from digital codes at rates of 9.6, 8 and 4.8 kb/s by an MPC algorithm. The terminal functions with a single 12 V power supplied vehicle battery. The equipment can operate at any L-band frequency allocated for mobile uses in a full duplex mode and will soon be put into a field test via Japans's ETS-V satellite.

Suzuki, Ryutaro↗

Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a u~ateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be compared with permittivity values generated from the Kline and Swift relationship. Two methods of calibration will be discussed, The errors that each technique introduces into the measurement resulls will be reviewed. Temperature stability, frequency drift and the effect of increasing cavity transmission loss on the unloaded cavity Q will also be discussed.

Lang, R.↗

Accuracy of relative positioning by interferometry with GPS Double-blind test results

MITES (Miniature Interferometer Terminals for Earth Surveying) observations conducted on December 17 and 29, 1980, are analyzed. It is noted that the time span of the observations used on each day was 78 minutes, during which five satellites were always above 20 deg elevation. The observations are analyzed to determine the intersite position vectors by means of the algorithm described by Couselman and Gourevitch (1981). The average of the MITES results from the two days is presented. The rms differences between the two determinations of the components of the three vectors, which were about 65, 92, and 124 m long, were 8 mm for the north, 3 mm for the east, and 6 mm for the vertical. It is concluded that, at least for short distances, relative positioning by interferometry with GPS can be done reliably with subcentimeter accuracy.

Counselman, C. C., III↗