Phase Identification in Synchrotron X-ray Diffraction Patterns of Ti–6Al–4V Using Computer Vision and Deep Learning

X-ray diffraction patterns contain information about the atomistic structure and microstructure (defect population) of materials, extracting detailed information from diffraction patterns is complex, demanding and relies on prior knowledge. Here, we hypothesize that deep-learning techniques can help to perform an effective and accurate analysis with high throughput rates. To demonstrate this concept, we applied a novel deep learning framework to determine the evolution of the β-phase volume fraction in a Ti–6Al–4V alloy during heat-treatment from video sequences of 2D diffraction patterns recorded in transmission and with highly monochromatic radiation in a synchrotron beamline. In particular, we studied the impact of network design on prediction reliability and computational performance. Networks of different architectures were trained using 3008 experimental 2D patterns. A well-tuned model was found to reproduce the phase fractions of another experimental data set, consisting of 1100 diffraction patterns, with a mean-square error as small as 2.6 x 10 -4 . The average prediction error of β-phase volume fraction was within 1.6 x 10 -2 (in each diffraction pattern) of the values obtained by conventional methods. Our work demonstrates that convolutional neural networks can evaluate high energy X-ray diffraction patterns with a remarkable level of reliability. Furthermore, it demonstrates the significance of network design on the reliability of predictions and computational performance. The most complex models do not necessarily result in highest accuracy and may even fail to learn from the data.

36 MATERIALS SCIENCE↗

Pink-beam serial crystallography

Serial X-ray crystallography allows macromolecular structure determination at both X-ray free electron lasers (XFELs) and, more recently, synchrotron sources. The time resolution for serial synchrotron crystallography experiments has been limited to millisecond timescales with monochromatic beams. The polychromatic, “pink”, beam provides a more than two orders of magnitude increased photon flux and hence allows accessing much shorter timescales in diffraction experiments at synchrotron sources. Here we report the structure determination of two different protein samples by merging pink-beam diffraction patterns from many crystals, each collected with a single 100 ps X-ray pulse exposure per crystal using a setup optimized for very low scattering background. In contrast to experiments with monochromatic radiation, data from only 50 crystals were required to obtain complete datasets. The high quality of the diffraction data highlights the potential of this method for studying irreversible reactions at sub-microsecond timescales using high-brightness X-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Laser-Electron-Interaction Region for Compact High Repetition-Rate Mono-Energetic Laser Based Gamma Sources

Inverse-Compton scattering (ICS) is a well-established technique capable of producing monochromatic radiation over a large range of the electromagnetic spectrum. Most recently, ICS has attracted attention, owing to its compactness and possible coupling with novel acceleration methods to yield compact X- and 𝛄-ray sources. Under this award, we carried out a systematic optimization of the ICS and demonstrate via numerical simulation that combining ICS with a conventional superconducting linac could produce Watt-level average-power 𝛄 rays with high spectral brightness. The study is performed with idealized laser and electron-beam distributions and confirmed with the realistic distributions simulated from start-to-end numerical modeling of the electron accelerator. The studies led to the design and engineering design of an ICS interaction point for the FAST facility along with some beam measurement. Due to the cancellation of the program in Year 3 long with delay in the commissioning of the FAST facility, we were not able to demonstrate the generation of 𝛄 rays, we, however, procured some of the hardware, installed some of the required infrastructures and plan to eventually generate 𝛄 ray pending future interest on the topics and availability of funding.

43 PARTICLE ACCELERATORS↗

Wide angle lenses with aspheric correcting surfaces

Refracting elements having aspheric correcting surfaces near the center of curvature are analyzed. As in the case of the Schmidt reflector, such systems can have a wide aperture and a wide field of view; in addition, they are free from obstructing surfaces. Being uncorrected for dispersion, however, the refracting systems are restricted to nearly monochromatic radiation. Typical forms of the correcting surfaces have been determined, both by third order theory and by numerical integration of exact equations.

Jones, R. T.↗

Dust-contamination monitor

Compact instrument gives instantaneous reading of accumulation of small particles on glass plate. Instrument is sensitive to particles as small as one hundred microns and should be adaptable to monitoring particulate air pollution or dust levels in semiconductor clean rooms. Dual collimated light sources produce highly monochromatic radiation direct at grazing single angle onto glass plate.

Claysmith, C. R.↗

Investigation of the effect of atmospheric dust on the determination of total ozone from the earth's ultraviolet reflectivity measurements, 1

Two computer algorithms are described. These algorithms were used for computing the aximuth-independent component of the intensity of the monochromatic radiation emerging at the top of a pseudo-spherical atmosphere with arbitrary vertical distribution of ozone, and with any arbitrary height distribution of up to two different kinds of aerosol. This atmospheric model was assumed to rest on a surface obeying Lambert's law of reflection.

Dave, J. V.↗

Measurement of the fundamental vibration-rotation spectrum of ClO

The ClO fundamental absorption band near 850/cm is observed, with a tunable PbSnTe diode laser used as a source of monochromatic radiation. The chlorine monoxide concentration in the absorption tube was measured indirectly via a UV transmission technique. Frequencies and assignments for the ClO lines, and band centers and rotational constants for the ClO fundamental vibration, are tabulated. Diatomic vibration-rotation transitions within and between electronic substates are discussed. The tunable diode laser is valuable for studying the hyperfine structure. The IR spectroscopic technique is developed in order to monitor chlorine monoxide concentration in the stratosphere, since the short-lived ClO is a crucial intermediate participant in reactions involving destruction of stratospheric ozone.

Menzies, R. T.↗

Solar-powered alkali metal vapor lasers

The emission spectrum of the A(1 Sigma u +) - X(1 Sigma g +) band of Na2 has been recorded following excitation by monochromatic radiation in the region of X-A and X-B absorption. The spectral profile has been investigated as a function of excitation wavelength, sodium vapor temperature and buffer gas pressure. Additionally, gain measurements were made for the satellite of the A-X band as a function of the sodium vapor temperature and buffer gas pressure.

Blount, Charles E.↗

The coherent backscattering opposition effect

We have measured the opposition effect, the nonlinear surge in reflectance seen in particulate materials as phase angle approaches zero degrees, in a suite of materials of varying particle size and reflectance. These samples were illuminated by linearly and circularly polarized monochromatic radiation at two wavelengths, 0.442 and 0.633 microns. By measuring the linear and circular polarization ratios for each sample, we have found that in highly reflective materials the behavior of the reflected radiation is consistent with the coherent backscattering process which has recently been proposed to explain the opposition surge that is seen in such media. The size and width of the coherent backscattering opposition peak vary as a function of reflectance of the sample. The opposition effect has been observed in particulate materials studied in the laboratory and it is also observed in the radiation reflected from solar system bodies which present a regolith to the earth based observer. The traditional explanation of the opposition effect, the shadow-hiding hypothesis, is that it was caused by the elimination of mutual shadows cast between the regolith grains as the phase angle of the observation became smaller. This shadow-hiding hypothesis, however, is unable to explain the opposition effect seen in highly reflective materials such as magnesium oxide and barium sulfate powders. This is because highly reflective media will multiply scatter the incident radiation between the regolith grains. This causes the shadows to be eliminated. We have measured the angular scattering properties of a suite of materials of different reflectivity. We have observed polarization ratios in reflective particulates that are consistent with coherent backscattering as the principal process which causes the opposition surge.

Nelson, R. M.↗

Accretion disk coronae in high-luminosity systems

We present the results of self-consistent models of Compton-heated accretion disk coronae. The models are calculated using a new method for computing monochromatic radiative transfer n two dimensions. The method splits the radiation into direct and scattered components. The direct radiation is computed by calculating the optical depth along rays, while transfer of the scattered radiation is approximated by flux-limited diffusion. The resulting code agrees with more accurate treatments to within 50%, and is highly efficient, making it practical for use in large hydrodynamic simulations. The coronal models are used to confirm the results of earlier work, and to extend it to higher luminosities. In contrast to earlier work, which found the outer disks to be shadowed by the inner corona at high luminosities, we find our results to form an almost continuous extension of the models at lower luminosities. This is due to the presence of multiply scattered radiation, which acts to partially offset the loss of direct radiation from the central source. Although the analytic methods derived at lower luminosities cannot be used to derive the coronal structure for L/L(sub Edd) approx. greater than 0.1, the results of the models are amenable to semiempirical fits. We also discuss possible observational consequences of the results for coronal veiling and line fluorescence from the disk.

Murray, Stephen D.↗

Macromolecular Topography Leaps into the Digital Age

A low-cost, real-time digital topography system is under development which will replace x-ray film and nuclear emulsion plates. The imaging system is based on an inexpensive surveillance camera that offers a 1000x1000 array of 8 im square pixels, anti-blooming circuitry, and very quick read out. Currently, the system directly converts x-rays to an image with no phosphor. The system is small and light and can be easily adapted to work with other crystallographic equipment. Preliminary images have been acquired of cubic insulin at the NSLS x26c beam line. NSLS x26c was configured for unfocused monochromatic radiation. Six reflections were collected with stills spaced from 0.002 to 0.001 degrees apart across the entire oscillation range that the reflections were in diffracting condition. All of the reflections were rotated to the vertical to reduce Lorentz and beam related effects. This particular CCD is designed for short exposure applications (much less than 1 sec) and so has a relatively high dark current leading to noisy raw images. The images are processed to remove background and other system noise with a multi-step approach including the use of wavelets, histogram, and mean window filtering. After processing, animations were constructed with the corresponding reflection profile to show the diffraction of the crystal volume vs. the oscillation angle as well as composite images showing the parts of the crystal with the strongest diffraction for each reflection. The final goal is to correlate features seen in reflection profiles captured with fine phi slicing to those seen in the topography images. With this development macromolecular topography finally comes into the digital age.

Lovelace, J.↗

Crystal regularity with high-resolution synchrotron X-radiation diffraction imaging

New, high-resolution sources of X-radiation such as monochromatic synchrotron radiation beams with subarcsec divergence allow observation of regularities in a range of crystals with sufficient clarity for comprehensive analyses, whose results can deepen understanding of the nature of various crystal irregularities, their sources, and their effects on device performance. An account is presented of the results thus achievable with irregularities encountered in lattice orientation and strain, grain and subgrain boundaries, dislocations, domain boundaries, additional phases, and surface scratches. Significant achievements to date encompass the observation of critical anomalies in lead tin telluride, the reconciliation of disparate observations of GaAs, the determination of the performance effects of irregularities in mercuric iodide, and the characterization of the origins of crystal growth in bismuth silicon oxide.

Steiner, Bruce↗

Multiphoton ionization of N2 by the third harmonic of a Nd:YAG laser - A new avenue for air diagnostics

Laser-induced N2 ionization is accomplished using a commercially available Nd:YAG laser, and confirmed by means of ion-collection and spectral measurements. Neutral N2 is excited by six photons of the third harmonic frequency, or 355 nm, and is transformed to an ionized state. The radiation at 355 nm is separated from the fundamental and frequency-doubled Nd:YAG radiation to guarantee monochromatic incident radiation. Intense lines near 391.4 nm are found in the initial laser polarization and for a 90-degree rotation of polarization. The radiation at 391.4 nm is associated with an incoherent laser-induced flourescence process related to an ionized-state transition, and increases quadratically with laser power. A 45-mJ laser pulse focused to a diameter of 17 microns can produce an ion concentration of 3.25 x 10 to the 13th ions/cu cm. The large ion concentration and robust fluorescence signal make this technique an efficient method for time-of-flight velocimetry and in-flight testing.

Laufer, Gabriel↗

Energy scale calibration of the KEDR tagging system

The KEDR detector tagging system is a symmetric focusing magnetic spectrometer of small-angle electrons born in the interaction region of the VEPP-4M collider. Using this system, which is designed for studying the two-photon processes, the scattered electrons and positrons energy is measured with a resolution of ΔE/E{sub 0}= 0.03–0.6% where E{sub 0} is the beam energy. Two different methods are employed for calibrating the tagging system energy scale: the first one involves the electron/positron tagging by the energy of the singlebremsstrahlung photon measured in the BGO calorimeter, and the second one is based on the determination of the recoil electrons spectrum edge in the Compton backscattering of monochromatic laser radiation. The technical implementation and the present status of the calibration system are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗