Search NASASearch

SEARCH · Search NASA

Results for “MPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore

Isolated galaxies, pairs, and groups of galaxies

The authors searched for isolated galaxies, pairs and groups of galaxies in the CfA survey (Huchra et al. 1983). It was assumed that the distances to galaxies are given by R = V/H sub o, where H sub o = 100 km s(exp -1) Mpc(exp -1) and R greater than 6 Mpc. The searching procedure is close to those, applied to find superclusters of galaxies (Kalinkov and Kuneva 1985, 1986). A sphere with fixed radius r (asterisk) is described around each galaxy. The mean spatial density in the sphere is m. Let G (sup 1) be any galaxy and G (sup 2) be its nearest neighbor at a distance R sub 2. If R sub 2 exceeds the 95 percent quintile in the distribution of the distances of the second neighbors, then G (sup 1) is an isolated galaxy. Let the midpoint of G (sup 1) and G (sup 2) be O sub 2 and r sub 2=R sub 2/2. For the volume V sub 2, defined with the radius r sub 2, the density D sub 2 less than k mu, the galaxy G (sup 2) is a single one and the procedure for searching for pairs and groups, beginning with this object is over and we have to pass to another object. Here the authors present the groups - isolated and nonisolated - with n greater than 3, found in the CfA survey in the Northern galactic hemisphere. The parameters used are k = 10 and r (asterisk) = 5 Mpc. Table 1 contains: (1) the group number, (2) the galaxy, nearest to the multiplet center, (3) multiplicity n, (4) the brightest galaxy if it is not listed in (2); (5) and (6) are R.A. and Dec. (1950), (7) - mean distance D in Mpc. Further there are the mean density rho (8) of the multiplet (galaxies Mpc (exp -3), (9) the density rho (asterisk) for r (asterisk) = 5 Mpc and (10) the density rho sub g for the group with its nearest neighbor. The parenthesized digits for densities in the last three columns are powers of ten.

Kuneva, I.

An adaptive identification and control scheme for large space structures

A unified identification and control scheme capable of achieving space at form performance objectives under nominal or failure conditions is described. Preliminary results are also presented, showing that the methodology offers much promise for effective robust control of large space structures. The control method is a multivariable, adaptive, output predictive controller called Model Predictive Control (MPC). MPC uses a state space model and input reference trajectories of set or tracking points to adaptively generate optimum commands. For a fixed model, MPC processes commands with great efficiency, and is also highly robust. A key feature of MPC is its ability to control either nonminimum phase or open loop unstable systems. As an output controller, MPC does not explicitly require full state feedback, as do most multivariable (e.g., Linear Quadratic) methods. Its features are very useful in LSS operations, as they allow non-collocated actuators and sensors. The identification scheme is based on canonical variate analysis (CVA) of input and output data. The CVA technique is particularly suited for the measurement and identification of structural dynamic processes - that is, unsteady transient or dynamically interacting processes such as between aerodynamics and structural deformation - from short, noisy data. CVA is structured so that the identification can be done in real or near real time, using computationally stable algorithms. Modeling LSS dynamics in 1-g laboratories has always been a major impediment not only to understanding their behavior in orbit, but also to controlling it. In cases where the theoretical model is not confirmed, current methods provide few clues concerning additional dynamical relationships that are not included in the theoretical models. CVA needs no a priori model data, or structure; all statistically significant dynamical states are determined using natural, entropy-based methods. Heretofore, a major limitation in applying adaptive controllers to LSS problems has been the requirement for accurate models. We feel that MPC coupled with the CVA identification scheme will resolve this limitation. The results are based on research performed under an SBIR grant, administered by the Air Force Office of Scientific Research.

Carroll, J. V.

Power spectrum, correlation function, and tests for luminosity bias in the CfA redshift survey

We describe and apply a method for directly computing the power spectrum for the galaxy distribution in the extension of the Center for Astrophysics Redshift Survey. Tests show that our technique accurately reproduces the true power spectrum for k greater than 0.03 h Mpc(exp -1). The dense sampling and large spatial coverage of this survey allow accurate measurement of the redshift-space power spectrum on scales from 5 to approximately 200 h(exp -1) Mpc. The power spectrum has slope n approximately equal -2.1 on small scales (lambda less than or equal 25 h(exp -1) Mpc) and n approximately -1.1 on scales 30 less than lambda less than 120 h(exp -1) Mpc. On larger scales the power spectrum flattens somewhat, but we do not detect a turnover. Comparison with N-body simulations of cosmological models shows that an unbiased, open universe CDM model (OMEGA h = 0.2) and a nonzero cosmological constant (CDM) model (OMEGA h = 0.24, lambda(sub zero) = 0.6, b = 1.3) match the CfA power spectrum over the wavelength range we explore. The standard biased CDM model (OMEGA h = 0.5, b = 1.5) fails (99% significance level) because it has insufficient power on scales lambda greater than 30 h(exp -1) Mpc. Biased CDM with a normalization that matches the Cosmic Microwave Background (CMB) anisotropy (OMEGA h = 0.5, b = 1.4, sigma(sub 8) (mass) = 1) has too much power on small scales to match the observed galaxy power spectrum. This model with b = 1 matches both Cosmic Background Explorer Satellite (COBE) and the small-scale power spect rum but has insufficient power on scales lambda approximately 100 h(exp -1) Mpc. We derive a formula for the effect of small-scale peculiar velocities on the power spectrum and combine this formula with the linear-regime amplification described by Kaiser to compute an estimate of the real-space power spectrum. Two tests reveal luminosity bias in the galaxy distribution: First, the amplitude of the pwer spectrum is approximately 40% larger for the brightest 50% of galaxies in volume-limited samples that have M(sub lim) greater than M*. This bias in the power spectrum is independent of scale, consistent with the peaks-bias paradigm for galaxy formation. Second, the distribution of local density around galaxies shows that regions of moderate and high density contain both very bright (M less than M* = -19.2 + 5 log h) and fainter galaxies, but that voids preferentially harbor fainter galaxies (approximately 2 sigma significance level).

Park, Changbom

Velocity correlations of galaxy clusters

We determine the velocity correlation function, pairwise peculiar velocity difference, and rms pairwise peculiar velocity dispersion of rich clusters of galaxies, as a function of pair separation, for three cosmological models: Omega = 1 and Omega = 0.3 cold dark matter (CDM), and Omega = 0.3 primeval baryonic isocurvature (PBI) models (all flat and Cosmic Background Explorer (COBE)-normalized). We find that close cluster pairs, with separation r is less than or equal to 10/h Mpc, exhibit strong attractive peculiar velocities in all models; the cluster pairwise velocities depend sensitively on the model. The mean pairwise attractive velocity of clusters on 5/h Mpc scale ranges from approximately 1700 km/s for Omega = 1 CDM to approximately 1000 km/s for PBI to approximately 700 km/s for Omega = 0.3 CDM. The small-scale pairwise velocities depend also on cluster mass: richer, more massive clusters exhibit stronger attractive velocities than less massive clusters. On large scales, from approximately 20 to 200/h Mpc, the cluster peculiar velocities are increasingly dominated by bulk and random motions; they are independent of cluster mass. The cluster velocity correlation function is negative on small scales for Omega = 1 and Omega = 0.3 CDM, indicating strong pairwise motion relative to bulk motion on small scales; PBI exhibits relatively larger bulk motions. The cluster velocity correlation function is positive on very large scales, from r approximately 10/h Mpc to r approximately 200/h Mpc, for all models. These positive correlations, which decrease monotonically with scale, indicate significant bulk motions of clusters up to approximately 200/h Mpc. The strong dependence of the cluster velocity functions on models, especially at small separations, makes them useful tools in constraining cosmological models when compared with observations.

Cen, Renyue

Intelligent Engine Systems: Adaptive Control

We have studied the application of the baseline Model Predictive Control (MPC) algorithm to the control of main fuel flow rate (WF36), variable bleed valve (AE24) and variable stator vane (STP25) control of a simulated high-bypass turbofan engine. Using reference trajectories for thrust and turbine inlet temperature (T41) generated by a simulated new engine, we have examined MPC for tracking these two reference outputs while controlling a deteriorated engine. We have examined the results of MPC control for six different transients: two idle-to-takeoff transients at sea level static (SLS) conditions, one takeoff-to-idle transient at SLS, a Bode power command and reverse Bode power command at 20,000 ft/Mach 0.5, and a reverse Bode transient at 35,000 ft/Mach 0.84. For all cases, our primary focus was on the computational effort required by MPC for varying MPC update rates, control horizons, and prediction horizons. We have also considered the effects of these MPC parameters on the performance of the control, with special emphasis on the thrust tracking error, the peak T41, and the sizes of violations of the constraints on the problem, primarily the booster stall margin limit, which for most cases is the lone constraint that is violated with any frequency.

Gibson, Nathan

Model Predictive Control Study for an Electrified Turbofan Engine

A control sensitivity study is conducted for electrified aircraft propulsion concepts using a publicly available turbofan engine simulation. A Proportional-Integral (PI) controller serves as a baseline for comparison against an advanced Model Predictive Control (MPC) approach. MPC is used in the control scheme to allow for subsystem coordination of engine and electric power loads. The electrified turbofan engine includes electric machines to augment the amount of torque being applied to the spools of the engine during transient phases of operation. Power augmentation allows for energy to be stored or exhausted in a manner that increases the fuel efficiency of the engine, reducing aircraft emissions and noise. The study compares the fan speed, high pressure compressor stall margin, and low pressure compressor stall margin against the baseline PI control system, an MPC system without electric machines, and an MPC system with electric machines. The MPC system with electric machines is optimized using the sample time, control horizon and prediction horizon. The MPC design provided a stable damped response as desired and allowed operability margins to be maintained

Electrified Aircraft Propulsion

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco

A neural-network-enhanced parameter-varying framework for multi-objective model predictive control applied to buildings

Management of the electrical grid is becoming more complex due to the increased penetration of alternative energy generation technologies and a broadening diversity of electric loads. This complexity creates challenges in balancing demand and generation that can increase the potential for grid instabilities. One effective way to address this issue is to leverage previously unexploited demand flexibility through advanced control strategies. In this work, we propose an advanced control method, called adaptive neural parameter-varying model predictive control (ANPV-MPC), to control the temperature and energy consumption of a building via its Heating, Ventilation, and Air Conditioning system. ANPV-MPC combines key ideas in parameter-varying control, adaptive control, and online learning strategies to bridge the gap between computationally efficient linear model predictive control and more accurate nonlinear model predictive control. The novelty in ANPV-MPC is the use of a physics-inspired Bayesian neural network to estimate the coefficients of the parameter-varying linear control model. The Bayesian neural network additionally provides uncertainty estimates, triggering online training to capture evolving building system conditions. We show that ANPV-MPC can approximate the building system dynamics with a 28.39% higher accuracy than traditional linear model predictive control, resulting in 36.23% better control performance without increasing complexity of the optimal control problem. ANPV-MPC also adapts in real time to previously unseen conditions using online learning, further improving its performance.

24 POWER TRANSMISSION AND DISTRIBUTION

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY

Remaining Life Prediction of SNF Storage Canisters Exposed to CISCC Environments

• DOE Standardized SNF Storage Canisters o DOE designed standard spent nuclear fuel (SNF) storage canisters for storage of DOE SNF. o DOE canisters are significantly different from commercial MultiPurpose Canisters (MPC) in size. o MPC canisters are large, a height = 15.8 ft, OD = 68”, WT = 0.5”. o DOE canisters are small with 18” / 24” diameter, 10’ / 15’ length. • Integrity Evaluation of DOE versus MPC Canisters o Many investigations have been performed for MPC canisters. o Limit investigations were performed for DOE standard canisters. Most were done at Idaho National Lab (INL). o DOE has sponsored integrity studies to evaluate weld integrity using drop tests and FEA simulations. o No evaluation on CISCC/service life of DOE canister in literature. o MPC canister: 4 axial welds, 1 center girth weld, 2 closing welds.

ZHU, Xiankui

Complex QSO absorbers: High-redshift clusters of galaxies?

Using the PSPC instrument on the ROSAT satellite, we have obtained deep exposures of the fields centered on the QSO's 1556+335, 1037-271, and 0854+191 in an effort to search for extended X-ray emission corresponding to complex QSO absorption-line systems (QALS's) that could be indicative of clusters of galaxies at high redshift. The QSO 1556+335 is known to have a pair of complicated C IV absorption systems at z equals 1.610 (Delta v = 988 km/s) and z equals 1.650 (Delta v = 1677 km/s) near the z equals 1.641 QSO redshift. It has been suggested that the absorption may be due to two rich clusters, one containing the QSO itself. The QSO 0854+191 (z(sub em) = 1.89) has 6 strong C IV absorption systems in 2 close groups at z equals 1.2954, 1.2973,1.3019 and z equals 1.3522, 1.3543, 1.3558. Assuming q(sub O) equals 0.5 and H(sub O) equals 50 km/s Mpc(exp -l), the redshift range of this absorption-line cluster corresponds to a radial distance of 44 Mpc. Interestingly, there is a nearby (approximately 30') QSO (0856+189) with a projected separation of 16 Mpc whose redshift (z = 1.29) is similar to that of the absorbing material toward 0854+191. In the case of 1037-271 (Z(sub em) = 2.18), common QALSs have been observed at z equals l.90, 1.96, 2.02, 2.08, and 2.14 (a radial range of 66 Mpc) in its spectrum and that of its neighbor Tol 1038-272 (Z(sub em) = 2.32) whose 18' separation corresponds to a linear distance of 9 Mpc at z approximately equals 2. The length scales implied by the absorbers toward 0854+191 and 1037-271 are interesting in that they suggest structures more akin to superclusters than clusters.

Meyer, David M.

Hot gas in the cold dark matter scenario: X-ray clusters from a high-resolution numerical simulation

A new, three-dimensional, shock-capturing hydrodynamic code is utilized to determine the distribution of hot gas in a standard cold dark matter (CDM) model of the universe. Periodic boundary conditions are assumed: a box with size 85 h(exp -1) Mpc having cell size 0.31 h(exp -1) Mpc is followed in a simulation with 270(exp 3) = 10(exp 7.3) cells. Adopting standard parameters determined from COBE and light-element nucleosynthesis, sigma(sub 8) = 1.05, omega(sub b) = 0.06, and assuming h = 0.5, we find the X-ray-emitting clusters and compute the luminosity function at several wavelengths, the temperature distribution, and estimated sizes, as well as the evolution of these quantities with redshift. We find that most of the total X-ray emissivity in our box originates in a relatively small number of identifiable clusters which occupy approximately 10(exp -3) of the box volume. This standard CDM model, normalized to COBE, produces approximately 5 times too much emission from clusters having L(sub x) is greater than 10(exp 43) ergs/s, a not-unexpected result. If all other parameters were unchanged, we would expect adequate agreement for sigma(sub 8) = 0.6. This provides a new and independent argument for lower small-scale power than standard CDM at the 8 h(exp -1) Mpc scale. The background radiation field at 1 keV due to clusters in this model is approximately one-third of the observed background, which, after correction for numerical effects, again indicates approximately 5 times too much emission and the appropriateness of sigma(sub 8) = 0.6. If we have used the observed ratio of gas to total mass in clusters, rather than basing the mean density on light-element nucleosynthesis, then the computed luminosity of each cluster would have increased still further, by a factor of approximately 10. The number density of clusters increases to z approximately 1, but the luminosity per typical cluster decreases, with the result that evolution in the number density of bright clusters is moderate in this redshift range, showing a broad peak near z = 0.7, and then a rapid decline above redshift z = 3. Detailed computations of the luminosity functions in the range L(sub x) = 10(exp 40) - 10(exp 44) ergs/s in various energy bands are presented for both cluster central regions and total luminosities to be used in comparison with ROSAT and other observational data sets. The quantitative results found disagree significantly with those found by other investigators using semianalytic techniques. We find little dependence of core radius on cluster luminosity and a dependence of temperature on luminosity given by log kT(sub x) = A + B log L(sub x), which is slightly steeper (B = 0.38) than is indicated by observations. Computed temperatures are somewhat higher than observed, as expected, in that COBE-normalized CDM has too much power on the relevant scales. A modest average temperature gradient is found, with temperatures dropping to 90% of central values at 0.4 h(exp -1) Mpc and 70% of central values at 0.9 h(exp -1) Mpc. Examining the ratio of gas to total mass in the clusters normalized to Omega(sub B) h(exp 2) = 0.015, and comparing with observations, we conclude, in agreement with White (1991), that the cluster observations argue for an open universe.

Kang, Hyesung

The Influence of Mesoscale Particle Structure on the Electrode Degradation and Resultant Electrochemistry of Lithium Ion Cells With Nickel Rich Lithium Nickel Manganese Cobalt Oxide Positive Electrodes

Nickel-rich lithium nickel manganese cobalt oxide, NMC (LiNi x Mn y Co z O 2 ), materials are desirable positive electrodes in lithium ion batteries, providing high capacity and energy density. The mesoscale structure of NMC materials is commonly a polycrystalline aggregate, providing opportunity for short lithium ion transport distance of the small primary particles, yet facile material handling due to the larger secondary particles. On (de)lithiation the NMC unit cell changes volume, where the anisotropic strain can result in secondary particle fracture. This secondary particle fracture process during cycling has been associated with several degradation modes of NMC materials in LIBs. In this work, a milling process was determined whereby the secondary particles could be pre-fractured with retention of the parent primary particle crystallographic structure, crystallite size, and morphology, providing the ability to unambiguously determine the influence of NMC secondary particle size and mesostructure on resultant functional behavior. The bulk and interfacial properties and electrochemistry of as-received commercially obtained polycrystal NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 , PC NMC) and its milled MPC NMC counterpart were compared. The smaller secondary particle size, higher surface area MPC NMC was found to result in 1) greater cathode tortuosity, 2) reduced surface Ni on the cycled MPC cathodes consistent with surface reconstruction, and 3) increased Ni deposition on the anodes from cathode-anode crosstalk. These factors manifested in unfavorable electrochemical behavior of MPC with lower functional capacity at both 1C and C/10 rates and higher impedance over extended moderate voltage (dis)charge cycling.

36 MATERIALS SCIENCE

Influence of zwitterionic amphiphilic copolymers on heterogeneous gypsum formation: A promising approach for scaling resistance

Here, this study aims to investigate the influence of zwitterionic amphiphilic copolymers (ZACs) in the nucleation and growth of heterogeneous CaSO4 at the zwitterion-water interface, which is crucial for the prevention of mineral scaling and consequent downtime or suboptimal performance in industries like membrane desalination, heat exchangers, and pipeline transportation. In situ grazing incidence small angle X-ray Scattering (GISAXS), and quartz crystal microbalance with dissipation (QCM-D) techniques were used to analyze the evolution of CaSO 4 particles on two new ZAC coatings: poly-(trifluoroethyl methacrylate-random-sulfobetaine methacrylate) (PTFEMA-r-SBMA, or PT:SBMA) and poly(trifluoroethyl methacrylate-random-2-methacryloyloxyethyl phosphorylcholine) (PTFEMA-r-MPC, or PT:MPC). The results showed that PT:MPC coatings promoted nucleation but inhibited crystal growth, resulting in slower overall reaction kinetics on PT:MPC coatings compared to PT:SBMA coatings. Interfacial interactions involving the substrates, sulfate minerals, and ions were examined, revealing that calcium ion adsorption, primarily governed by electrostatic attraction, played a crucial role in the nucleation and growth processes on both ZAC coatings. The crystal characterization revealed a phase transition from bassanite to gypsum on both ZAC coatings, suggesting that these zwitterionic materials can influence the mineral phase of heterogeneously formed CaSO 4 crystals. These findings enhance our understanding of the fundamental mechanisms underlying heterogeneous CaSO 4 scaling in the presence of zwitterionic materials.

42 ENGINEERING

The DESI One-Percent Survey: Modelling the clustering and halo occupation of all four DESI tracers with U CHUU

We present results from a set of mock lightcones for the DESI One-Percent Survey, created from the UCHUU simulation. This 8 h −3 Gpc 3 N-body simulation comprises 2.1 trillion particles and provides high-resolution dark matter (sub)haloes in the framework of the Planck-based ΛCDM cosmology. Employing the subhalo abundance matching (SHAM) technique, we populated the UCHUU (sub)haloes with all four DESI tracers – Bright Galaxy Survey (BGS), luminous red galaxies (LRGs), emission line galaxies (ELGs), and quasars (QSOs) – to z = 2.1. Our method accounts for redshift evolution as well as the clustering dependence on luminosity and stellar mass. The two-point clustering statistics of the DESI One-Percent Survey generally agree with predictions from UCHUU across scales ranging from 0.3 h −1 Mpc to 100 h −1 Mpc for the BGS and across scales ranging from 5 h −1 Mpc to 100 h −1 Mpc for the other tracers. We observed some differences in clustering statistics that can be attributed to incompleteness of the massive end of the stellar mass function of LRGs, our use of a simplified galaxy-halo connection model for ELGs and QSOs, and cosmic variance. We find that at the high precision of UCHUU, the shape of the halo occupation distribution (HOD) of the BGS and LRG samples is smaller bias values, likely due to cosmic variance. The bias dependence on absolute magnitude, stellar mass, and redshift aligns with that of previous surveys. These results provide DESI with tools to generate high-fidelity lightcones for the remainder of the survey and enhance our understanding of the galaxy-halo connection.

cosmology