Search NASA⌕ Search

SEARCH · Search NASA

Results for “MSE Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spectral Effects on Fast Wave Core Heating and Current Drive

Recent results obtained with high harmonic fast wave (HHFW) heating and current drive (CD) on NSTX strongly support the hypothesis that the onset of perpendicular fast wave propagation right at or very near the launcher is a primary cause for a reduction in core heating efficiency at long wavelengths that is also observed in ICRF heating experiments in numerous tokamaks. A dramatic increase in core heating efficiency was first achieved in NSTX L-mode helium majority plasmas when the onset for perpendicular wave propagation was moved away from the antenna and nearby vessel structures. Efficient core heating in deuterium majority L mode and H mode discharges, in which the edge density is typically higher than in comparable helium majority plasmas, was then accomplished by reducing the edge density in front of the launcher with lithium conditioning and avoiding operational points prone to instabilities. These results indicate that careful tailoring of the edge density profiles in ITER should be considered to limit rf power losses to the antenna and plasma facing materials. Finally, in plasmas with reduced rf power losses in the edge regions, the first direct measurements of high harmonic fast wave current drive were obtained with the motional Stark effect (MSE) diagnostic. The location and radial dependence of HHFW CD measured by MSE are in reasonable agreement with predictions from both full wave and ray tracing simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and validation of a critical gradient energetic particle driven Alfven eigenmode transport model for DIII-D tilted neutral beam experiments

Recent experiments with the DIII-D tilted neutral beam injection (NBI) varying the beam energetic particle (EP) source profiles have provided strong evidence that unstable Alfven eigenmodes (AE) drive stiff EP transport at a critical EP density gradient. Here the critical gradient is identified by the local AE growth rate being equal to the local ITG/TEM growth rate at the same low toroidal mode number. The growth rates are taken from the gyrokinetic code GYRO. Simulation show that the slowing down beam-like EP distribution has a slightly lower critical gradient than the Maxwellian. The ALPHA EP density transport code, used to validate the model, combines the low-n stiff EP critical density gradient AE mid-core transport with the energy independent high-n ITG/TEM density transport model controling the central core EP density profile. For the on-axis NBI heated DIII-D shot 146102, while the net loss to the edge is small, about half the birth fast ions are transported from the central core r/a < 0.5 and the central density is about half the slowing down density. Lastly, these results are in good agreement with experimental fast ion pressure profiles inferred from MSE constrained EFIT equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the internal magnetic field on DIII-D using intensity and spacing of the motional Stark multiplet

We describe a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of Stark split D{sub {alpha}} emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the ratio of the intensities of the {pi}{sub 3} and {sigma}{sub 1} lines. These lines originate from the same upper level and so are not dependent on the level populations. In future devices, such as ITER, this technique may have advantages over diagnostics based on MSE polarimetry. We have done an optimization of the viewing direction for the available ports on DIII-D to choose the installation location. With this placement, we have a near optimal viewing angle of 59.6 deg. from the vertical direction. All hardware has been installed for one chord, and we have been routinely taking data since January 2007. We fit the spectra using a simple Stark model in which the upper level populations of the D{sub {alpha}} transition are treated as free variables. The magnitude and direction of the magnetic field obtained using this diagnostic technique compare well with measurements from MSE polarimetry and EFIT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robotic calibration of the motional Stark effect diagnostic on Alcator C-Mod

The capability to calibrate diagnostics, such as the Motional Stark Effect (MSE) diagnostic, without using plasma or beam-into-gas discharges will become increasingly important on next step fusion facilities due to machine availability and operational constraints. A robotic calibration system consisting of a motorized three-axis positioning system and a polarization light source capable of generating arbitrary polarization states with a linear polarization angle accuracy of <0.05° has been constructed and has been used to calibrate the MSE diagnostic deployed on Alcator C-Mod. The polarization response of the complex diagnostic is shown to be fully captured using a Fourier expansion of the detector signals in terms of even harmonics of the input polarization angle. The system's high precision robotic control of position and orientation allow it to be used also to calibrate the geometry of the instrument's view. Combined with careful measurements of the narrow bandpass spectral filters, this system fully calibrates the diagnostic without any plasma discharges. The system's high repeatability, flexibility, and speed has been exploited to quantify several systematics in the MSE diagnostic response, providing a more complete understanding of the diagnostic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of DIII-D plasmas for Future Measurements of the Driven Current Density in the DIII-D High Field Side Lower Hybrid Experiment

High field side (HFS) lower hybrid current drive (LHCD) is a promising method for efficiently driving off-axis current in steady state tokamak power plants. The first test of this technology is underway at the DIII-D tokamak. The initial physics goal is to measure the LH-driven current density profile in order to validate the ray-tracing/Fokker-Plank codes GENRAY/CQL3D and gain confidence in their ability to predict LH deposition in future DIII-D experiments and fusion power plants. DIII-D’s motional Stark effect (MSE) diagnostic will be used to constrain the magnetic equilibrium reconstructions. From these reconstructions, the ohmic, bootstrap, and driven non-inductive components of the current density profile can be extracted. Several recent DIII-D plasmas have been identified in which GENRAY/CQL3D predict measurable amounts of current with only 100 kW of coupled power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Geothermal Drilling: Oil and Gas Technology Transfer

There is a significant amount of financial risk associated with geothermal drilling. This study of drilling operations seeks opportunities to improve upon current practices and technologies. The scope of this study included analyzing 21 geothermal wells and 21 oil and gas wells. The goal was to determine a 'Perfect Well' using historical data to compare the best oil and gas well to the best geothermal well. Unfortunately, limitations encountered in the study included missing data (bit records, mud information, etc.) and poor data collection practices An online software database was used to format drilling data to IADC coded daily drilling reports and generate figures for analysis. Six major issues have been found in geothermal drilling operations. These problems include lost circulation, rig/ equipment selection, cementing, penetration rate, drilling program, and time management. As a result of these issues, geothermal drilling averaged 56.4 days longer than drilling comparable oil and gas wells in the wells in this study. Roughly $13.9 million was spent on non-productive time in the 21 geothermal wells, compared with only $1.3 million in the oil and gas wells, assuming a cost of $50,000 per day. Comparable events such as drilling the same sized hole, tripping in/out, cementing, and running the same size casing took substantially less time in the oil and gas wells. Geothermal wells were drilled using older and/or less advanced technology to depths less than 10,000 feet, while oil and gas wells reached 12,500 feet faster with purpose built rigs. A new approach is now underway that will optimize drilling programs throughout the drilling industry using Mechanical Specific Energy (MSE) as a tool to realize efficient drilling processes. Potential improvements for current geothermal operations are: the use of electronic records, real time services, and official glossary terms to describe rig operations, and advanced drilling rigs/technology.

15 GEOTHERMAL ENERGY↗

Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR

A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1–3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Geothermal Drilling: Oil and Gas Technology Transfer

There is a significant amount of financial risk associated with geothermal drilling; however, there are opportunities to improve upon current practices and technologies used. The scope of this drilling operational study included 21 geothermal wells and 21 oil and gas wells. The goal was to determine a 'perfect well' using historical data to compare the best oil and gas well to the best geothermal well. Unfortunately, limitations encountered in the study included missing data (bit records, mud information, etc.), poor data collection, and difficult to ascertain handwriting. An online software database was used to format drilling data to IADC coded daily drilling reports and generate analysis figures. Six major issues have been found in geothermal drilling operations. These problems include lost circulation, rig/equipment selection, cementing, penetration rate, drilling program, and time management. As a result of these issues, geothermal drilling averages 56.4 days longer than drilling comparable oil and gas wells in the wells in this study. Roughly $13.9 million would be lost due to non-productive time in the 21 geothermal wells and only $1.3 million in the oil and gas wells, assuming a cost of $50,000 per day. Comparable events such as drilling the same sized hole, tripping in/out, cementing, and running the same size casing took substantially less time in the oil and gas wells. Geothermal wells were drilled using older and/or less advanced technology to depths less than 10,000 feet, while oil and gas wells reached 12,500 feet faster with purpose built rigs. A new approach is now underway that will optimize drilling programs throughout the drilling industry. It is the use of Mechanical Specific Energy (MSE) as a tool to realize efficient drilling processes. However, a work-flow must also be established in order for there to be an efficient drilling program. Potential improvements for current geothermal operations are: the use of electronic records, real time services, and official glossary terms to describe rig operations, and advanced drilling rigs/technology.

15 GEOTHERMAL ENERGY↗

The motional Stark effect diagnostic on NSTX

This work describes the implementation and recent results from the motional Stark effect (MSE) collisionally induced fluorescence diagnostic on NSTX. Due to the low magnetic field on NSTX the MSE diagnostic requires a new approach for the viewing optics and spectral filter. This has been accomplished with a novel optical design that reduces the geometric Doppler broadening, and a high throughput, high resolution spectral filter to optimize signal-to-noise ratio. With these improvements the polarization fraction is {approx}30%-40% and, combined with the large throughput, a time resolution of {approx}5 ms. The MSE diagnostic presently has 16 sight lines operating, providing measurements of the magnetic field line pitch from the plasma center to near the outboard edge of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities. (2016-06-06)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of tokamak plasma safety factor profile using deep learning

Abstract The motional Stark effect (MSE) diagnostic has been a standard measurement for the magnetic field line pitch angle in tokamaks that are equipped with neutral beams. However, the MSE data are not always available due to experimental constraints, especially in future devices without neutral beams. Here we develop a deep-learning based model (SGTC-QR) that can reconstruct the safety factor profile without the MSE diagnostic to mimic the traditional equilibrium reconstruction with the MSE constraint. The model demonstrates promising performance, and the sub-millisecond inference time is compatible with the real-time plasma control system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of the q and p profiles in ITER from external and internal measurements

A method is developed for calculating uncertainties in reconstructing the equilibrium profiles of the safety factor q and plasma pressure p in the ITER device from external magnetic measurements and from motional Stark effect line polarization (MSE-LP) and motional Stark effect line shift (MSE-LS) signals from excited NBI atoms inside the plasma core. It is shown that, with MSE-LP signals, as well as with MSE-LS signals (the use of which was recently proposed by Nova Photonics, Inc.), it is possible to substantially improve the reconstruction of the profiles that determine the plasma magnetic configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of the q and p profiles in ITER from external and internal measurements

A method is developed for calculating uncertainties in reconstructing the equilibrium profiles of the safety factor q and plasma pressure p in the ITER device from external magnetic measurements and from motional Stark effect line polarization (MSE-LP) and motional Stark effect line shift (MSE-LS) signals from excited NBI atoms inside the plasma core. It is shown that, with MSE-LP signals, as well as with MSE-LS signals (the use of which was recently proposed by Nova Photonics, Inc.), it is possible to substantially improve the reconstruction of the profiles that determine the plasma magnetic configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗