Search NASA⌕ Search

SEARCH · Search NASA

Results for “MTV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

The Exploration of Mars Launch and Assembly Simulation

Advancing human exploration of space beyond Low Earth Orbit, and ultimately to Mars, is of great interest to NASA, other organizations, and space exploration advocates. Various strategies for getting to Mars have been proposed. These include NASA's Design Reference Architecture 5.0, a near-term flyby of Mars advocated by the group Inspiration Mars, and potential options developed for NASA's Evolvable Mars Campaign. Regardless of which approach is used to get to Mars, they all share a need to visualize and analyze their proposed campaign and evaluate the feasibility of the launch and on-orbit assembly segment of the campaign. The launch and assembly segment starts with flight hardware manufacturing and ends with final departure of a Mars Transfer Vehicle (MTV), or set of MTVs, from an assembly orbit near Earth. This paper describes a discrete event simulation based strategic visualization and analysis tool that can be used to evaluate the launch campaign reliability of any proposed strategy for exploration beyond low Earth orbit. The input to the simulation can be any manifest of multiple launches and their associated transit operations between Earth and the exploration destinations, including Earth orbit, lunar orbit, asteroids, moons of Mars, and ultimately Mars. The simulation output includes expected launch dates and ascent outcomes i.e., success or failure. Running 1,000 replications of the simulation provides the capability to perform launch campaign reliability analysis to determine the probability that all launches occur in a timely manner to support departure opportunities and to deliver their payloads to the intended orbit. This allows for quantitative comparisons between alternative scenarios, as well as the capability to analyze options for improving launch campaign reliability. Results are presented for representative strategies.

Cates, Grant↗

Development of Hydroxyl Tagging Velocimetry for Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging technique that relies on the photo-dissociation of water vapor into OH radicals and their subsequent tracking using laser induced fluorescence. Velocities are then obtained from time-of-flight calculations. At ambient temperature in air, the OH species lifetime is relatively short (<50 μs), making it suited for high speed flows. Lifetime and radicals formation increases with temperature, which allows HTV to also probe low-velocity, high-temperature flows or reacting flows such as flames. The present work aims at extending the domain of applicability of HTV, particularly towards low-speed (<10 m/s) and moderate (<500 K) temperature flows. Results are compared to particle image velocimetry (PIV) measurements recorded in identical conditions. Single shot and averaged velocity profiles are obtained in an air jet at room temperature. By modestly raising the temperature (100-200 degC) the OH production increases, resulting in an improvement of the signal-to-noise ratio (SNR). Use of nitrogen - a non-reactive gas with minimal collisional quenching - extends the OH species lifetime (to over 500 μs), which allows probing of slower flows or, alternately, increases the measurement precision at the expense of spatial resolution. Instantaneous velocity profiles are resolved in a 100degC nitrogen jet (maximum jet-center velocity of 6.5 m/s) with an uncertainty down to 0.10 m/s (1.5%) at 68% confidence level. MTV measurements are compared with particle image velocimetry and show agreement within 2%.

Andre, Matthieu A.↗

Development of a Molecular Tagging Velocimetry Technique for Non-Intrusive Velocity Measurements in Low-Speed Gas Flows

N2O molecular tagging velocimetry (N2O-MTV) is developed for use in very-high-temperature reactor environments. Tests were carried out to determine the optimum excitation wavelength, tracer concentration, and timing parameters for the laser system. Using NO tracers obtained from photo-dissociation of N2O, velocity profiles are successfully obtained in air, nitrogen, and helium for a large range of parameters: temperature from 295 to 781 K, pressure from 1 to 3 bars, with a velocity precision of 0.01 m/s. Furthermore, by using two read pulses at adjustable time delays, the velocity dynamic range can be increased. An unprecedented dynamic range of 5,000 has been obtained to successfully resolve the flow during a helium blowdown from 1000 m/s down to 0.2 m/s. This technique is also applied to the high-temperature test facility (HTTF) at Oregon State University (OSU) during a depressurized condition cooldown (DCC) event. Details of these measurements are presented in a companion paper. This technique shows a strong potential for fundamental understanding of gas flows in nuclear reactors and to provide benchmark experimental data to validate numerical simulations.

Andre, M. A.↗

TPSAS-NF1676L-32869-DND

Three unseeded molecular tagging velocimetry (MTV) techniques have been demonstrated in NASA Langley’s 0.3-meter Transonic Cryogenic Tunnel (TCT). High pressure, cryogenic gaseous N2 is used to produce high Reynolds number transonic flow in TCTs, allowing small aircraft and space vehicles to be tested at flight Reynolds numbers. These facilities generally cannot be seeded with particles or toxic gases so unseeded velocimetry methods are needed. Three Laser Electronic Excitation and Tagging (LEET) techniques were tested: Femtosecond LEET (FLEET), Picosecond LEET (PLEET) and Selective Two-photon Absorptive Resonance Femtosecond LEET (STARFLEET). All three techniques were used over a range of pressures (124 to 517 kPa), temperatures (100-300 K) and Mach numbers (0.2-0.8) to measure freestream conditions and were then compared to conditions determined by the facility data system using conventional wall pressures and probes. Measurement precision and accuracy are presented, as are signal intensity and lifetimes which impact measurement uncertainties and are useful for understanding and modelling the various LEET processes.

P Danehy↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗