Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Optimization of 3D controlled ELM-free state with recovered global confinement for KSTAR with n = 1 resonant magnetic field perturbation

Mitigation of deleterious heat flux from edge-localized modes (ELMs) on fusion reactors is often attempted with 3D perturbations of the confining magnetic fields. However, the established technique of resonant magnetic perturbations (RMPs) also degrades plasma performance, complicating implementation on future fusion reactors. Here, we introduce an adaptive real-time control scheme on the KSTAR tokamak as a viable approach to achieve an ELM-free state and simultaneously recover high-confinement (βN ~ 1.91, β p ~ 1.53, and H 98 ~ 0.9), demonstrating successful handling of a volatile complex system through adaptive measures. We show that, by exploiting a salient hysteresis process to adaptively minimize the RMP strength, stable ELM suppression can be achieved while actively encouraging confinement recovery. This is made possible by a self-organized transport response in the plasma edge which reinforces the confinement improvement through a widening of the ion temperature pedestal and promotes control stability, in contrast to the deteriorating effect on performance observed in standard RMP experiments. These results establish the real-time approach as an up-and-coming solution toward an optimized ELM-free state, which is an important step for the operation of ITER and reactor-grade tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods and systems for low to ultra-low magnetic field nuclear magnetic resonance for detecting chemical nerve agents

A nuclear magnetic resonance (NMR) system is configured to detect chemical threat material. The system comprises a magnet configured to generate a magnetic field of about 300 millitesla or less; and a probe configured to detect nuclear relaxation of at least two nuclei selected from the group consisting of 1H, 19F, 31P and 14N, and detect the spin density of nuclei selected from the group consisting of 1H, 19F, 31P and 14N, following excitation.

Williams, Robert F.↗

A Telomerase-Activated Magnetic Resonance Imaging Probe for Consecutively Monitoring Tumor Growth Kinetics and In Situ Screening Inhibitors

Telomerase has long been considered as a biomarker for cancer diagnosis and a therapeutic target for drug discovery. Detecting telomerase activity in vivo could provide more direct information of tumor progression and response to drug treatment, which, however, is hampered by the lack of an effective probe that can generate an output signal without a tissue penetration depth limit. Here in this study, using the principle of distance-dependent magnetic resonance tuning, we constructed a telomerase-activated magnetic resonance imaging probe (TAMP) by connecting superparamagnetic ferroferric oxide nanoparticles (SPFONs) and paramagnetic Gd-DOTA (Gd(III) 1,4,7,10- tetraazacyclododecane-1,4,7,10-tetraazacyclododecane-1,4,7,10-tet-raacetic acid) complexes via telomerase-responsive DNA motifs. Upon telomerase-catalyzed extension of the primer in TAMP, Gd-DOTA-conjugated oligonucleotides can be liberated from the surface of SPFONs through a DNA strand displacement reaction, restoring the T 1 signal of the Gd-DOTA for a direct readout of the telomerase activity. Here we show that, by tracking telomerase activity, this probe provides consistent monitoring of tumor growth kinetics during progression and in response to drug treatment and enables in situ screening of telomerase inhibitors in whole-animal models. This study provides an alternative toolkit for cancer diagnosis, treatment response assessment, and anticancer drug screening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The onset of rare earth metallosis begins with renal gadolinium-rich nanoparticles from magnetic resonance imaging contrast agent exposure

The leitmotifs of magnetic resonance imaging (MRI) contrast agent-induced complications range from acute kidney injury, symptoms associated with gadolinium exposure (SAGE)/gadolinium deposition disease, potentially fatal gadolinium encephalopathy, and irreversible systemic fibrosis. Gadolinium is the active ingredient of these contrast agents, a non-physiologic lanthanide metal. The mechanisms of MRI contrast agent-induced diseases are unknown. Mice were treated with a MRI contrast agent. Human kidney tissues from contrast-naïve and MRI contrast agent-treated patients were obtained and analyzed. Kidneys (human and mouse) were assessed with transmission electron microscopy and scanning transmission electron microscopy with X-ray energy-dispersive spectroscopy. MRI contrast agent treatment resulted in unilamellar vesicles and mitochondriopathy in renal epithelium. Electron-dense intracellular precipitates and the outer rim of lipid droplets were rich in gadolinium and phosphorus. We conclude that MRI contrast agents are not physiologically inert. The long-term safety of these synthetic metal–ligand complexes, especially with repeated use, should be studied further.

36 MATERIALS SCIENCE↗

Optical readout of singlet fission biexcitons in a heteroacene with photoluminescence detected magnetic resonance

Molecular spin systems based on photoexcited triplet pairs formed via singlet fission (SF) are attractive as carriers of quantum information because of their potentially pure and controllable spin polarization, but developing systems that offer optical routes to readout as well as initialization is challenging. Herein, we characterize the electron spin magnetic resonance change in the photoluminescence intensity for a tailored organic molecular crystal while sweeping a microwave drive up to 10 GHz in a broadband loop structure. We observe resonant transitions for both triplet and quintet spin sublevel populations showing their optical sensitivity and revealing the zero-field parameters for each. We map the evolution of these spectra in both microwave frequency and magnetic field, producing a pattern of optically detected magnetic resonance (ODMR) peaks. Fits to these data using a suitable model suggest significant spin polarization in this system with orientation selectivity. Unusual excitation intensity dependence is also observed, which inverts the sign of the ODMR signal for the triplet features, but not for the quintet. These observations demonstrate optical detection of the spin sublevel population dictated by SF and intermolecular geometry, and highlight anisotropic and multi-scale dynamics of triplet pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neoclassical transport due to resonant magnetic perturbations in DIII-D

In this work, the role of neoclassical physics in the particle and energy transport during the application of resonant magnetic perturbations (RMPs) to suppress the edge localised modes in a tokamak is analysed. The neoclassical fluxes in non-axisymmetric DIII-D equilibria with applied RMPs are calculated using the NEO code. The magnetic field provided to NEO as an input is calculated using M3D-C1 and includes the nonlinear one-fluid plasma response. Neoclassical fluxes obtained in this study are found to dramatically increase in the presence of applied resonant magnetic perturbations, and are in same range as the total radial particle fluxes calculated in comparable RMP discharges in DIII-D. This suggests that neoclassical transport plays a significant role in edge transport when RMPs are present. An increase in neoclassical fluxes during the ELM suppressed phase in DIII-D plasmas is calculated and is strongly correlated with the observation of density pump-out in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytical model for quasi-linear flow response to resonant magnetic perturbation in resistive-inertial and viscous-resistive regimes

In this work, a quasi-linear model for plasma flow response to the resonant magnetic perturbation (RMP) in a tokamak has been rigorously developed in the resistive-inertial (RI) and viscousresistive (VR) regimes purely from the two-field reduced MHD model. Models for plasma response to RMP are commonly composed of equations for the resonant magnetic field response (i.e. the magnetic island) and the torque balance of plasma flow. However, in previous plasma response models, the magnetic island and the torque balance equations are often derived separately from reduced MHD and full MHD equations, respectively. By contrast, in this work we derive both the magnetic island response and the torque balance equations in a quasi-linear model for plasma flow response entirely from a set of two-field reduced MHD equations. Such a quasi-linear model can recover previous plasma flow response models within certain limits and approximations. Furthermore, the physical origins of quasi-linear forces and moments in the flow response equation are also accurately calculated and clarified self-consistently.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of nematic susceptibility with phase sensitive nuclear magnetic resonance in pulsed strain fields

Here, we present nuclear magnetic resonance data in BaFe 2 As 2 in the presence of pulsed strain fields that are interleaved in time with the radio frequency excitation pulses. In this approach, the preceding nuclear magnetization acquires a phase shift that is proportional to the strain and pulse time. The sensitivity of this approach is limited by the homogeneous decoherence time, T 2 , rather than the inhomogeneous linewidth. We measure the nematic susceptibility as a function of temperature and demonstrate a three orders of magnitude improvement in sensitivity. This approach will enable studies of the strain response in a broad range of materials that previously were inaccessible due to inhomogeneous broadening.

36 MATERIALS SCIENCE↗

Resonant mode effects on rotation braking induced by n = 1 resonant magnetic perturbations in the EAST tokamak

Abstract The spectrum effects on toroidal rotation braking, induced by n = 1 resonant magnetic perturbations (RMPs) in the discharges with q 95 = 4.1 and q 95 = 5.1 , are studied in the EAST tokamak. Here n is the toroidal mode number, RMP spectrum is varied by scanning δ ϕ U L , the phase difference between the upper and lower rows of RMP coils. The toroidal rotation changes periodically with the periodic δ ϕ U L scanning and such an effect is stronger in the discharge with lower q 95 = 4.1 . The spectrum dependence of the neoclassical toroidal viscosity (NTV) torque, modeled by NTVTOK based on the magnetic perturbation obtained from MARS-F calculation, agrees well with that of the experimentally observed braking torques in both discharges. The modeled NTV torque is stronger in the discharge with lower q 95 , which also agrees with the observations. The comparisons between the spectrum dependence of the NTV and magnetic perturbations show that the resonant mode of magnetic perturbations near the plasma edge mainly contribute the NTV torque. These agreements between modeling and experiments highlight the capability of NTV theory in explaining the experimental observation in the EAST tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The safety of magnetic resonance imaging contrast agents

Gadolinium-based contrast agents are increasingly used in clinical practice. While these pharmaceuticals are verified causal agents in nephrogenic systemic fibrosis, there is a growing body of literature supporting their role as causal agents in symptoms associated with gadolinium exposure after intravenous use and encephalopathy following intrathecal administration. Gadolinium-based contrast agents are multidentate organic ligands that strongly bind the metal ion to reduce the toxicity of the metal. The notion that cationic gadolinium dissociates from these chelates and causes the disease is prevalent among patients and providers. We hypothesize that non-ligand-bound (soluble) gadolinium will be exceedingly low in patients. Soluble, ionic gadolinium is not likely to be the initial step in mediating any disease. The Kidney Institute of New Mexico was the first to identify gadolinium-rich nanoparticles in skin and kidney tissues from magnetic resonance imaging contrast agents in rodents. In 2023, they found similar nanoparticles in the kidney cells of humans with normal renal function, likely from contrast agents. We suspect these nanoparticles are the mediators of chronic toxicity from magnetic resonance imaging contrast agents. This article explores associations between gadolinium contrast and adverse health outcomes supported by clinical reports and rodent models.

59 BASIC BIOLOGICAL SCIENCES↗

Impurity transport in the pedestal of H-mode plasmas with resonant magnetic perturbations

Experiments on DIII-D show that resonant magnetic perturbations (RMPs) reduce the impurity confinement time in the H-mode pedestal below that of naturally ELMy plasmas. STRAHL modeling of discharges with aluminum laser blow off (LBO) injection show increased diffusion in the pedestal of H-mode discharges with RMPs. The increased diffusion from the RMPs provides improved impurity control compared to the naturally ELMy discharges and prevents the buildup of impurities near the edge of the plasma. Tungsten LBO injection into discharges with and without RMPs led to striking differences in the evolution of the discharge. The naturally ELMy discharge became ELM free and showed an increase in edge radiation, leading to the eventual radiative collapse of the plasma. Injecting a similar number ofWparticles into discharges with RMPs, either with or without ELMs, led to a measurable accumulation of core W but did not significantly impact the evolution of the discharge. Furthermore, these results indicate that RMPs are beneficial for controlling the buildup of impurities in the pedestal region of the plasma.

60 APPLIED LIFE SCIENCES↗

Nuclear Magnetic Resonance Relaxation Pathways in Electrolytes for Energy Storage

Nuclear Magnetic Resonance (NMR) spin relaxation times have been an instrumental tool in deciphering the local environment of ionic species, the various interactions they engender and the effect of these interactions on their dynamics in conducting media. Of particular importance has been their application in studying the wide range of electrolytes for energy storage, on which this review is based. Here we highlight some of the research carried out on electrolytes in recent years using NMR relaxometry techniques. Specifically, we highlight studies on liquid electrolytes, such as ionic liquids and organic solvents; on semi-solid-state electrolytes, such as ionogels and polymer gels; and on solid electrolytes such as glasses, glass ceramics and polymers. Although this review focuses on a small selection of materials, we believe they demonstrate the breadth of application and the invaluable nature of NMR relaxometry.

25 ENERGY STORAGE↗

Molecular Modes Elucidate the Nuclear Magnetic Resonance Relaxation of Viscous Fluids

The Bloembergen, Purcell, and Pound (BPP) theory of nuclear magnetic resonance (NMR) relaxation in fluids dating back to 1948 continues to be the linchpin in interpreting NMR relaxation data in applications ranging from characterizing fluids in porous media to medical imaging (MRI). The BPP theory is founded on assuming molecules are hard spheres with 1 H– 1 H dipole pairs reorienting randomly; assumptions that are severe in light of modern understanding of liquids. Nevertheless, it is intriguing to this day that the BPP theory was consistent with the original experimental data for glycerol, a hydrogen-bonding molecular fluid for which the hard-sphere-rigid-dipole assumption is inapplicable. To better understand this incongruity, atomistic molecular simulations are used to compute 1 H NMR T 1 relaxation dispersion (i.e., frequency dependence) in two contrasting cases: glycerol, and a (non hydrogen-bonding) viscosity standard. At high viscosities, simulations predict distinct functional forms of T 1 for glycerol compared to the viscosity standard, in agreement with modern measurements, yet both in contrast to BPP theory. The cause of these departures from BPP theory is elucidated, without assuming any relaxation models and without any free parameters, by decomposing the simulated T 1 response into dynamic molecular modes for both intramolecular and intermolecular interactions. The decomposition into dynamic molecular modes provides an alternative framework to understand the physics of NMR relaxation for viscous fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic resonance control of spin-correlated radical pair dynamics in vivo

Magnetic fields can influence reactions involving spin-correlated radical pairs (SCRPs). This provides a mechanism by which both static and time-varying magnetic fields can affect living systems at the biomolecular level. However, an engineered SCRP system conferring magnetic sensitivity to a non-native biochemical process in a multicellular organism has not yet been demonstrated. Here, in this study, we demonstrate control of SCRP dynamics using magnetic resonance in a live transgenic animal. We show that the emission of various red fluorescent proteins (RFPs), in the presence of a flavin cofactor, can be modified by a combination of static and radiofrequency magnetic fields applied near the electron spin resonance frequency. This effect was measured at room temperature both in vitro and in the nematode Caenorhabditis elegans, genetically modified to express the RFP mScarlet. These observations suggest that the magnetic field effects measured in RFP-flavin systems are due to quantum-correlated radical pairs with a coherence time larger than 4 ns. Our experiments demonstrate that radiofrequency magnetic fields can influence dynamics of reactions involving SCRPs in vivo, potentially enabling new methods for remotely controlling biomolecular processes, such as gene expression, and suggest broader potential for quantum tools in biology.

Burd, Shaun C. [Stanford Univ., CA (United States)↗

Nuclear Magnetic Resonance Dynamics of LiTFSI–Pyrazole Eutectic Solvents

Deep Eutectic Solvents (DESs) have emerged as promising candidates to replace conventional organic solvents in various technological applications due to their low vapor pressure, non-flammability, and ease of preparation at low costs. In particular, Type IV DESs, which are composed of metal salts and hydrogen bond donors, are possible replacements for lithium-ion battery electrolytes. In this study, we investigate the molecular dynamics of solvents of lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) and pyrazole (PYR) at varying LiTFSI:PYR molar ratios (1:2, 1:3, 1:4, 1:5) using Nuclear Magnetic Resonance Dispersion (NMRD) and Pulsed Field Gradient (PFG) Nuclear Magnetic Resonance (NMR). PFG NMR reveals composition-dependent diffusion trends, while NMRD provides molecular-level insights into the longitudinal relaxation rate (R 1 = 1/T 1 ). Notably, the LiTFSI:PYR (1:2) sample shows distinct behavior across both techniques, exhibiting enhanced relaxation rates and lower self-diffusion for 1 H compared to the other nuclei ( 19 F and 7 Li), suggestive of stronger and more efficient Li + –pyrazole interactions, as confirmed by the modeling of the relaxation profiles. Our study advances understanding of ion dynamics in azole-based eutectic solvents, supporting their potential use in safer battery electrolytes.

FFC-NMR↗

Probe for operando in situ electrochemical nuclear magnetic resonance spectroscopy

Electrochemical devices with metal casings have been considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. According to the present invention, rf fields can still efficiently penetrate into nonmetallic layers of electrochemical cells (such as a coin cell battery configuration) provided the magnetic field is oriented tangentially to the electrochemical cell electrodes in a “skimming” orientation. As an example, noninvasive high field in situ 7Li and 19F NMR of an unmodified commercial off-the-shelf rechargeable coin cell was demonstrated using a traditional external NMR coil setup. The in operando NMR measurements revealed that irreversible physical changes accumulate at the anode during electrochemical cycling.

Sorte, Eric Glenn↗

Comparison of Machine Learning and Deep Learning for View Identification from Cardiac Magnetic Resonance Images

Background: Artificial intelligence is increasingly utilized to aid in the interpretation of cardiac magnetic resonance (CMR) studies. One of the first steps is the identification of the imaging plane depicted, which can be achieved by both deep learning (DL) and classical machine learning (ML) techniques without user input. We aimed to compare the accuracy of ML and DL for CMR view classification and to identify potential pitfalls during training and testing of the algorithms. Methods: To train our DL and ML algorithms, we first established datasets by retrospectively selecting 200 CMR cases. The models were trained using two different cohorts (passively and actively curated) and applied data augmentation to enhance training. Once trained, the models were validated on an external dataset, consisting of 20 cases acquired at another center. We then compared accuracy metrics and applied class activation mapping (CAM) to visualize DL model performance. Results: The DL and ML models trained with the passively-curated CMR cohort were 99.1% and 99.3% accurate on the validation set, respectively. However, when tested on the CMR cases with complex anatomy, both models performed poorly. After training and testing our models again on all 200 cases (active cohort), validation on the external dataset resulted in 95% and 90% accuracy, respectively. The CAM analysis depicted heat maps that demonstrated the importance of carefully curating the datasets to be used for training. Conclusions: Both DL and ML models can accurately classify CMR images, but DL outperformed ML when classifying images with complex heart anatomy.

artificial intelligence↗