Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spectral characteristics of the iron oxides with application to the Martian bright region mineralogy

Reflectance spectra of eight polymorphs of FeOOH and Fe2O3 are determined in order to clarify the nature and significance of the iron oxide mineralogy on Mars. The effect of other components that might interfere with iron oxide absorption features is qualitatively constrained through the use of the Kebulka-Munk theory. It is found that the effect of temperature complicates the identification of a given Fe(3+) phase based on the position of the 6A1-4T1 absorption feature. While the Fe(3+) crystal field transitions are spin forbidden, most of the iron oxide polymorphs exhibit anomalously intense crystal field absorption features due to magnetic coupling between adjacent FeO6 octahedra. It is suggested that the resulting deviations from observed remotely sensed reflectance spectra of Mars may provide a basis for the exclusion of many iron oxide phases as significant components of the Martian Fe(3+) mineralogy. A comparison of these results with the visible region spectra of Martian bright regions indicates that the predominant Fe(3+)-bearing phase may be a magnetically disordered material, such as amorphous gels, some ferric sulphates, and other minerals in which Fe(3+) ions in the crystal structure are not magnetically coupled.

Sherman, D. M.↗

Future Development Trajectories for Imaging X-rays Spectrometers Based on Microcalorimeters

Future development trajectories for imaging x-ray spectrometers based on microcalorimeters. Since their invention 30 years ago, the capability of X-ray microcalorimeters has increased steadily, with continual improvements in energy resolution, speed, and array size. Arrays of up to 1024 pixels have been produced, and resolution better than 1 eV at 1.5 keV has been achieved. These detectors can be optimized for the highest priority science, such as designing for the highest resolving power at low energies at the expense of dynamic range, or the greatest focal-plane coverage at the expense of speed. Three types of X-ray microcalorimeters presently dominate the field, each characterized by the thermometer technology. The first two types use temperature-sensitive resistors: semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a magnetically coupled thermometer, and is at an earlier stage of development than the other two. The Soft X-ray Spectrometer (SXS) on Astro-H, expected to launch in 2015, will use an array of silicon thermistors with HgTe X-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays. Kilopixel arrays of the superconducting calorimeters are being produced, and much larger arrays may require the non-dissipative advantage of magnetically coupled thermometers. I will project the development trajectories of these detectors and their read-out technologies and assess what their capabilities and limitations will be 10 - 20 years from now.

Kilbourne, Caroline A.↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrodynamic coupling in magnetically confined X-ray plasmas of astrophysical origin

Explicitly magnetic field-independent relationships that quantitatively connect the thermodynamic state of the confined beta-less-than-one X-ray plasma to the confining magnetic loop characteristics and the stressing velocity at beta greater than about one are presented. The derived relations fall into two categories: (1) diffuse heating resulting from efficient transport of energy throughout the magnetic loop volume, and (2) isolated heating within the electrodynamic dissipation shell. For each of these cases the Joule dissipation, shear viscous dissipation, and compressional dissipation are considered. Each of these models is characterized by three thermodynamic scalings that are parametrized by the magnetic loop properties and by the stressing velocity. Eliminating the magnetic field intermediary from these relations and normalizing the inverse aspect ratio and the magnetic expansion factor with respect to solar conditions results in a single, unique velocity scaling law for each model.

Ionson, J. A.↗

A Multiphysics Thermoelastoviscoplastic Damage Internal State Variable Constitutive Model including Magnetism

We present a macroscale constitutive model that couples magnetism with thermal, elastic, plastic, and damage effects in an Internal State Variable (ISV) theory. Previous constitutive models did not include an interdependence between the internal magnetic (magnetostriction and magnetic flux) and mechanical fields. Although constitutive models explaining the mechanisms behind mechanical deformations caused by magnetization changes have been presented in the literature, they mainly focus on nanoscale structure–property relations. A fully coupled multiphysics macroscale ISV model presented herein admits lower length scale information from the nanoscale and microscale descriptions of the multiphysics behavior, thus capturing the effects of magnetic field forces with isotropic and anisotropic magnetization terms and moments under thermomechanical deformations. For the first time, this ISV modeling framework internally coheres to the kinematic, thermodynamic, and kinetic relationships of deformation using the evolving ISV histories. For the kinematics, a multiplicative decomposition of deformation gradient is employed including a magnetization term; hence, the Jacobian represents the conservation of mass and conservation of momentum including magnetism. The first and second laws of thermodynamics are used to constrain the appropriate constitutive relations through the Clausius–Duhem inequality. The kinetic framework employs a stress–strain relationship with a flow rule that couples the thermal, mechanical, and magnetic terms. Experimental data from the literature for three different materials (iron, nickel, and cobalt) are used to compare with the model’s results showing good correlations.

36 MATERIALS SCIENCE↗

A Multiphysics Thermoelastoviscoplastic Damage Internal State Variable Constitutive Model including Magnetism

We present a macroscale constitutive model that couples magnetism with thermal, elastic, plastic, and damage effects in an Internal State Variable (ISV) theory. Previous constitutive models did not include an interdependence between the internal magnetic (magnetostriction and magnetic flux) and mechanical fields. Although constitutive models explaining the mechanisms behind mechanical deformations caused by magnetization changes have been presented in the literature, they mainly focus on nanoscale structure–property relations. A fully coupled multiphysics macroscale ISV model presented herein admits lower length scale information from the nanoscale and microscale descriptions of the multiphysics behavior, thus capturing the effects of magnetic field forces with isotropic and anisotropic magnetization terms and moments under thermomechanical deformations. For the first time, this ISV modeling framework internally coheres to the kinematic, thermodynamic, and kinetic relationships of deformation using the evolving ISV histories. For the kinematics, a multiplicative decomposition of deformation gradient is employed including a magnetization term; hence, the Jacobian represents the conservation of mass and conservation of momentum including magnetism. The first and second laws of thermodynamics are used to constrain the appropriate constitutive relations through the Clausius–Duhem inequality. The kinetic framework employs a stress–strain relationship with a flow rule that couples the thermal, mechanical, and magnetic terms. Experimental data from the literature for three different materials (iron, nickel, and cobalt) are used to compare with the model’s results showing good correlations.

36 MATERIALS SCIENCE↗

Unraveling the origin of antiferromagnetic coupling at YIG/permalloy interface

We investigate the structural and electronic origin of antiferromagnetic (AFM) coupling in the yttrium iron garnet (YIG) and permalloy (Ni 80 ⁢Fe 20 , Py) bilayer system at the atomic level. Ferromagnetic resonance (FMR) spectra reveal unique hybrid modes in samples prepared with surface ion milling, indicative of antiferromagnetic exchange coupling at the YIG/Py interface. Using atomic resolution scanning transmission electron microscopy (STEM), we found that AFM coupling appears at the YIG/Py interface of the tetrahedral YIG surface formed with ion milling. Here, the STEM measurements suggest that the interfacial AFM coupling is predominantly driven by an oxygen-mediated superexchange coupling mechanism, which is confirmed by the density-functional theory (DFT) calculations to be energetically favorable. Thus, the combined experimental and theoretical results reveal the critical role of interfacial atomic structure in determining the type of magnetic coupling in a YIG/ferromagnet heterostructure, and prove that the interfacial structure can be experimentally tuned by surface ion milling.

36 MATERIALS SCIENCE↗

Magnetic circuitry mutual coupling probe

Development of magnetic probe for nondestructive testing of multilayer printed circuit boards to determine existence of opens or shorts is reported. Components of probe are described and procedures for operation are discussed. Two illustrations are provided to show magnetic circuits and principles of operation.

Anthony, P. L.↗

A remotely interrogatable sensor for chemical monitoring

A new type of continuously operating, in-situ, remotely monitored sensor is presented. The sensor is comprised of a thin film array of magnetostatically coupled, magnetically soft ferromagnetic thin film structures, adhered to or encased within a thin polymer layer. The polymer is made so that it swells or shrinks in response to the chemical analyte of interest, which in this case is pH. As the polymer swells or shrinks, the magnetostatic coupling between the magnetic elements changes, resulting in changes in the magnetic switching characteristics of the sensor. Placed within a sinusoidal magnetic field the magnetization vector of the coupled sensor elements periodically reverses directions, generating magnetic flux that can be remotely detected as a series of voltage spikes in appropriately placed pickup coils. one preliminary sensor design consists of four triangles, initially spaced approximately 50 micrometers apart, arranged to form a 12 mm x 12 mm square with the triangle tips centered at a common origin. Our preliminary work has focused on monitoring of pH using a lightly crosslinked pH sensitive polymer layer of hydroxyethylmethacrylate and 2-(dimethylamino) ethylmethacrylate. As the polymer swells or shrinks the magnetostatic coupling between the triangles changes, resulting in measurable changes in the amplitude of the detected voltage spirits.

Non-NASA Center↗

First Principles Cable Braid Electromagnetic Penetration Model - Potential Impedance Clarification

In this report the lack of assumed connectivity between braid carriers imposes the need to use the original magnetic vector potential formulas for transfer and self impedances rather than the final simplified results in the magnetic coupling and propagation formulas. Each of the magnetic sections in the previous journal article and Sandia report are addressed with references to the appropriate formulas.

42 ENGINEERING↗

Observational magnetometer calibration with the Hubble Space Telescope's new magnetometers

The two magnetometers recently replaced on the Hubble Space Telescope during the STS-61 Servicing Mission are now being used successfully for Coarse Attitude Determination during spacecraft vehicle safemode recovery operation. The magnetometer alignments relative to the spacecraft's vehicle's reference frame and the magnetic coupling of the sensors to the four magnetic torquer bars were determined. Coarse Attitude determination errors are now reduced to an average of 0.6 deg. Magnetometer Sensing System calibration and Coarse Attitude determination testing with the new calibration parameters is a geometrical problem. Telemetered earth magnetic field data was collected at twenty-six different vehicle attitudes. The spacecraft attitudes selected were distributed as widely apart as possible throughout the Geocentric Inertial Coordinate reference frame. It is also desirable to sample the Earth's magnetic field over as many different locations of the spacecraft's passage over the Earth as possible, within the limitation of the +/- 28.5 deg orbital inclination. A full range of magnetic moment outputs from the torquer bars needs to be sampled, +/- 3600 ampmeters squared, as well as data when the torquer bars have zero current. Graphic utilities were also developed to visually aid in optimizing the data collection process. Finally, a brief discussion of a method for collecting data for future calibrations is suggested.

Broude, Sidney M.↗

Contactless Magnetic Slip Ring

A contactless magnetic slip ring is disclosed having a primary coil and a secondary coil. The primary and secondary coils are preferably magnetically coupled together, in a highly reliable efficient manner, by a magnetic layered core. One of the secondary and primary coils is rotatable and the contactless magnetic slip ring provides a substantially constant output.

Kumagai, Hiroyuki↗

A Vibrational Energy Harvesting Sensor Based on Linear and Rotational Electromechanical Effects

In this investigation, a magnetically coupled double-spring design is presented for harvesting low-level non-stationary random vibrational energy. The sensor relies on multimodal coupling between the translation and rotation of a two-spring magnet and coil system to widen the harvesting bandwidth. Energy methods are used to develop a model to characterize the electromechanical response of the system, the solution of which is obtained using stochastic techniques based on a particle swarm algorithm. This approach provides an efficient method to estimate system parameters that otherwise are difficult or impossible to determine with independent measurements. The experimental results demonstrate agreement with the theoretical predictions over a limited bandwidth. The sensor can effectively harvest non-stationary vibration energy down to 10 -4 g within a limited bandwidth of 130–150 Hz. The sensor prototype has an operational volume of 2.6 cm 3 with a calculated power density of 0.2 W/cm 3 . The sensor’s small size results in a coupling efficiency of approximately 6% across the tested bandwidth.

42 ENGINEERING↗

First-Principles Statistical Mechanics Study of Magnetic Fluctuations and Order–Disorder in the Spinel LiNi 0.5 Mn 1.5 O 4 Cathode

While significant magnetic interactions exist in lithium transition metal oxides, commonly used as Li-ion cathodes, the interplay between magnetic couplings, disorder, and redox processes remains poorly understood. In this work, we focus on the high-voltage spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) cathode as a model system on which to apply a computational framework that uses first principles-based statistical mechanics methods to predict the finite temperature magnetic properties of materials and provide insights into the complex interplay between magnetic and chemical degrees of freedom. Density functional theory calculations on multiple distinct Ni–Mn orderings within the LNMO system, including the ordered ground-state structure (space group P4332), reveal a preference for a ferrimagnetic arrangement of the Ni and Mn sublattices due to strong antiferromagnetic superexchange interactions between neighboring Mn 4+ and Ni 2+ ions and ferromagnetic Mn–Mn and Ni–Ni couplings, as revealed by magnetic cluster expansions. These results are consistent with qualitative predictions using the Goodenough-Kanamori-Anderson rules. Simulations of the finite temperature magnetic properties of LNMO are conducted using Metropolis Monte Carlo. We find that a “semiclassical” Monte Carlo sampling method based on the Heisenberg Hamiltonian accurately predicts experimental magnetic transition temperatures observed in magnetometry measurements. This study highlights the importance of a robust computational toolkit that accurately captures the complex chemomagnetic interactions and predicts finite temperature magnetic behavior to help analyze experimental magnetic and magnetic resonance spectroscopy data acquired ex situ and operando.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗