Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mars samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In-Situ phase and texture characterization of solution deposited PZT thin films during crystallization.

Ferroelectric lead zirconate titanate (PZT) thin films are used for integrated capacitors, ferroelectric memory, and piezoelectric actuators. Solution deposition is routinely used to fabricate these thin films. During the solution deposition process, the precursor solutions are spin coated onto the substrate and then pyrolyzed to form an amorphous film. The amorphous film is then heated at a higher temperature (650-700 C) to crystallize the film into the desired perovskite phase. Phase purity is critical in achieving high ferroelectric properties. Moreover, due to the anisotropy in the structure and properties of PZT, it is desirable to control the texture obtained in these thin films. The heating rate during crystallization process is known to affect the sequence of phase evolution and texture obtained in these thin films. However, to date, a comprehensive understanding of how phase and texture evolution takes place is still lacking. To understand the effects of heating rate on phase and texture evolution, in-situ diffraction experiments during the crystallization of solution deposited PZT thin films were carried out at beamline 6-ID-B, Advanced Photon Source (APS). The high X-ray flux coupled with the sophisticated detectors available at the APS synchrotron source allow for in-situ characterization of phase and texture evolution at the high ramp rates that are commonly used during processing of PZT thin films. A PZT solution of nominal composition 52/48 (Zr/Ti) was spin coated onto a platinum-coated Si substrate (Pt//TiO{sub x}//SiO{sub 2}//Si). The films were crystallized using an infrared lamp, similar to a rapid thermal annealing furnace. The ramp rate was adjusted by controlling the voltage applied to the infrared lamp and increasing the voltage by a constant step with every acquisition. Four different ramp rates, ranging from {approx}1000 C/s to {approx}1 C/s, were investigated. The sample was aligned in grazing incidence to maximize the signal from the thin films. Successive diffraction patterns were acquired with a 1s acquisition time using a MAR SX-165 CCD detector during crystallization. The sample to detector distance and the tilt rotations of the detector were determined in Fit2D{copyright} by using Al{sub 2}O{sub 3} as the calibrant. These corrections were applied to the patterns when binning the data into radial (2{theta}) and azimuthal bins. The texture observed in the thin film was qualitatively analyzed by fitting the intensity peaks along the azimuthal direction with a gaussian profile function to obtain the integrated intensity of the peaks. Data analysis and peak fitting was done using the curve fitting toolbox in MATLAB{copyright}. A fluorite-type phase was observed to form before the perovskite phase for all ramp rates. PtxPb is a transient intermetallic formed due to the interaction of the thin film and the bottom electrode during crystallization. Ramp rate was observed to significantly affect the amount of PtxPb observed in the thin films during crystallization. Ramp rate was also observed to affect the final texture obtained in the thin films. These results will be discussed in the poster in view of the current understanding of these materials.

43 PARTICLE ACCELERATORS↗

Characterizing K2 Candidate Planetary Systems Orbiting Low-mass Stars. II. Planetary Systems Observed During Campaigns 1–7

We recently used near-infrared spectroscopy to improve the characterization of 76 low-mass stars around which K2 had detected 79 candidate transiting planets. 29 of these worlds were new discoveries that had not previously been published. We calculate the false positive probabilities that the transit-like signals are actually caused by non-planetary astrophysical phenomena and reject five new transit-like events and three previously reported events as false positives. We also statistically validate 17 planets (7 of which were previously unpublished), confirm the earlier validation of 22 planets, and announce 17 newly discovered planet candidates. Revising the properties of the associated planet candidates based on the updated host star characteristics and refitting the transit photometry, we find that our sample contains 21 planets or planet candidates with radii smaller than 1.25 R {sub ⊕}, 18 super-Earths (1.25–2 R {sub ⊕}), 21 small Neptunes (2–4 R {sub ⊕}), three large Neptunes (4–6 R {sub ⊕}), and eight giant planets (>6 R {sub ⊕}). Most of these planets are highly irradiated, but EPIC 206209135.04 (K2-72e, 1.29{sub −0.13}{sup +0.14} R{sub ⊕}), EPIC 211988320.01 (R{sub p}=2.86{sub −0.15}{sup +0.16} R{sub ⊕}), and EPIC 212690867.01 (2.20{sub −0.18}{sup +0.19} R{sub ⊕}) orbit within optimistic habitable zone boundaries set by the “recent Venus” inner limit and the “early Mars” outer limit. In total, our planet sample includes eight moderately irradiated 1.5–3 R {sub ⊕} planet candidates (F {sub p} ≲ 20 F {sub ⊕}) orbiting brighter stars (Ks < 11) that are well-suited for atmospheric investigations with the Hubble, Spitzer, and/or James Webb Space Telescopes. Five validated planets orbit relatively bright stars (Kp < 12.5) and are expected to yield radial velocity semi-amplitudes of at least 2 m s{sup −1}. Accordingly, they are possible targets for radial velocity mass measurement with current facilities or the upcoming generation of red optical and near-infrared high-precision RV spectrographs.

79 ASTRONOMY AND ASTROPHYSICS↗

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Degradation of Adenine on the Martian Surface in the Presence of Perchlorates and Ionizing Radiation: A Reflectron Time-of-flight Mass Spectrometric Study

The aim of the present work is to unravel the radiolytic decomposition of adenine (C{sub 5}H{sub 5}N{sub 5}) under conditions relevant to the Martian surface. Being the fundamental building block of (deoxy)ribonucleic acids, the possibility of survival of this biomolecule on the Martian surface is of primary importance to the astrobiology community. Here, neat adenine and adenine–magnesium perchlorate mixtures were prepared and irradiated with energetic electrons that simulate the secondary electrons originating from the interaction of the galactic cosmic rays with the Martian surface. Perchlorates were added to the samples since they are abundant—and therefore relevant oxidizers on the surface of Mars—and they have been previously shown to facilitate the radiolysis of organics such as glycine. The degradation of the samples were monitored in situ via Fourier transformation infrared spectroscopy and the electron ionization quadruple mass spectrometric method; temperature-programmed desorption profiles were then collected by means of the state-of-the-art single photon photoionization reflectron time-of-flight mass spectrometry (PI-ReTOF-MS), allowing for the detection of the species subliming from the sample. The results showed that perchlorates do increase the destruction rate of adenine by opening alternative reaction channels, including the concurrent radiolysis/oxidation of the sample. This new pathway provides a plethora of different radiolysis products that were identified for the first time. These are carbon dioxide (CO{sub 2}), isocyanic acid (HNCO), isocyanate (OCN{sup −}), carbon monoxide (CO), and nitrogen monoxide (NO); an oxidation product containing carbonyl groups (R{sub 1}R{sub 2}–C=O) with a constrained five-membered cyclic structure could also be observed. Cyanamide (H{sub 2}N–C≡N) was detected in both irradiated samples as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the Elemental Composition of Phobos: The Mars-moon Exploration with GAmma rays and NEutrons (MEGANE) Investigation for the Martian Moons eXploration (MMX) Mission

The Mars-moon Exploration with GAmma rays and NEutrons (MEGANE) investigation will use gamma-ray and neutron spectroscopy to measure the elemental composition of Mars' moon Phobos. MEGANE is part of the Japanese Martian Moons eXploration (MMX) mission that will make comprehensive remote sensing measurements of both of Mars' moons Phobos and Deimos. MMX will also return to Earth regolith samples of Phobos. The science goals of the MEGANE investigation mirror those of the MMX mission. MEGANE will use elemental composition measurements to determine if Phobos is a captured asteroid or the end result of a giant impact event on Mars, study Phobos surface processes, provide reconnaissance to support the sample site selection, and supply compositional context for the returned samples. To accomplish its measurements, MEGANE will use a high-purity Ge gamma-ray spectrometer (GRS), and a neutron spectrometer (NS) that consists of two 3He gas proportional neutron sensors. The GRS derives heritage from similar instruments from NASA's MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission and the Psyche mission that is currently in development; the NS is based on similar instruments used for NASA's Lunar Prospector and Psyche missions.

79 ASTRONOMY AND ASTROPHYSICS↗

The Ricor K508 cryocooler operational experience on Mars

The Mars Science Laboratory (Curiosity) landed successfully on Mars on August 5, 2012, eight months after launch. The chosen landing site of Gale Crater, located at 4.5 degrees south latitude, 137.4 degrees east longitude, has provided a much more benign environment than was originally planned for during the critical design and integration phases of the MSL Project when all possible landing sites were still being considered. The expected near-surface atmospheric temperatures at the Gale Crater landing site during Curiosity's primary mission (1 Martian year or 687 Earth days) are from −90°C to 0°C. However, enclosed within Curiosity's thermal control fluid loops the Chemistry and Mineralogy (CheMin) instrument is maintained at approximately +20°C. The CheMin instrument uses X-ray diffraction spectroscopy to make precise measurements of mineral constituents of Mars rocks and soil. The instrument incorporated the commercially available Ricor K508 Stirling cycle cryocooler to cool the CCD detector. After several months of brushing itself off, stretching and testing out its subsystems, Curiosity began the exploration of the Mars surface in October 2012. The CheMin instrument on the Mars Science Laboratory (MSL) received its first soil sample from Curiosity on October 24, and successfully analyzed its first soil sample. After a brief review of the rigorous Ricor K508 cooler qualification tests and life tests based on the original MSL environmental requirements this paper presents final pre-launch instrument integration and testing results, and details the operational data of the CheMin cryocooler, providing a snapshot of the resulting CheMin instrument analytical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Petrographic and spectral study of hydrothermal mineralization in drill core from Hawaii: A potential analog to alteration in the martian subsurface

Abstract Continuous rock core was collected for 1764 m (5786’) on the Pohakuloa Army Training base near the center of the big island of Hawaii. The core traverses basaltic lava flows from the volcano's shield-building phase, and perched aquifers and higher temperature groundwaters were encountered. The collected samples record water-rock interactions of basaltic materials in a setting that may be a model for groundwater interactions on Mars. We collected visible and infrared point spectra of materials in the lowest portion of the core, where alteration was noted to become more prominent. We identified three types of phyllosilicate spectral signatures and three types of zeolites. The phyllosilicates show similarity to those identified on Mars using data from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM). Based on the field survey, 25 depths were selected for sampling and petrographic analysis of thin sections. The spectral data and thin section work have a strong agreement in the types of materials identified by the two different techniques. Both the spectral and petrographic data indicate low to moderate temperature geothermal alteration occurred in the lower half of the core. The field spectra are a useful reconnaissance tool for selecting mineralogic diversity for subsequent higher resolution and more time-consuming laboratory analysis.

Geochemistry & Geophysics↗

LANL Researcher Roger Wiens Discusses ChemCam

Discussion of the ChemCam instrument on the Curiosity Rover that occurred during the NASA press conference prior to launch of the Mars Science Laboratory. The ChemCam instrument was developed by Los Alamos National Laboratory and the French Space Institute. Los Alamos National Laboratory researcher Roger Wiens discusses the instrument on this video. ChemCam uses a laser to "zap" features of the Martian landscape and then uses a spectrometer to gather information about the composition of the sample. ChemCam will help the Curiosity Rover determine whether Mars is or was habitable. The Rover is expected to touch down on the Red Planet on August 5, 2012.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantification of water content by laser induced breakdown spectroscopy on Mars

Laser induced breakdown spectroscopy (LIBS), as performed by the ChemCam instrument, provides a new technique to measure hydrogen at the surface of Mars. Using a laboratory replica of the LIBS instrument onboard the Curiosity rover, different types of hydrated samples (basalts, calcium and magnesium sulfates, opals and apatites) covering a range of targets observed on Mars have been characterized and analyzed in this paper. A number of factors related to laser parameters, atmospheric conditions and differences in targets properties can affect the standoff LIBS signal, and in particular the hydrogen emission peak. Dedicated laboratory tests were run to identify a normalization of the hydrogen signal which could best compensate for these effects and enable the application of the laboratory calibration to Mars data. We check that the hydrogen signal increases linearly with water content; and normalization of the hydrogen emission peak using to oxygen and carbon emission peaks (related to the breakdown of atmospheric carbon dioxide) constitutes a robust approach. Finally, moreover, the calibration curve obtained is relatively independent of the samples types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alteration of immature sedimentary rocks on Earth and Mars. Recording Aqueous and Surface-atmosphere Processes

The rock alteration and rind formation in analog environments like Antarctica may provide clues to rock alteration and therefore paleoclimates on Mars. Clastic sedimentary rocks derived from basaltic sources have been studied in situ by martian rovers and are likely abundant on the surface of Mars. Moreover, how such rock types undergo alteration when exposed to different environmental conditions is poorly understood compared with alteration of intact basaltic flows. Here we characterize alteration in the chemically immature Carapace Sandstone from Antarctica, a terrestrial analog for martian sedimentary rocks. We employ a variety of measurements similar to those used on previous and current Mars missions. Laboratory techniques included bulk chemistry, powder X-ray diffraction (XRD), hyperspectral imaging and X-ray absorption spectroscopy. Through these methods we find that primary basaltic material in the Carapace Sandstone is pervasively altered to hydrated clay minerals and palagonite as a result of water–rock interaction. A thick orange rind is forming in current Antarctic conditions, superimposing this previous aqueous alteration signature. The rind exhibits a higher reflectance at visible-near infrared wavelengths than the rock interior, with an enhanced ferric absorption edge likely due to an increase in Fe 3+ of existing phases or the formation of minor iron (oxy)hydroxides. This alteration sequence in the Carapace Sandstone results from decreased water–rock interaction over time, and weathering in a cold, dry environment, mimicking a similar transition early in martian history. This transition may be recorded in sedimentary rocks on Mars through a similar superimposition mechanism, capturing past climate changes at the hand sample scale. These results also suggest that basalt-derived sediments could have sourced significant volumes of hydrated minerals on early Mars due to their greater permeability compared with intact igneous rocks.

58 GEOSCIENCES↗

Germanium Detectors in Homeland Security at PNNL

Neutron and gamma-ray detection is used for non-proliferation and national security applications. While lower energy resolution detectors such as NaI(Tl) have their place, high purity germanium (HPGe) also has a role to play. A detection with HPGe is often a characterization due to the very high energy resolution. However, HPGe crystals remain small and expensive leaving arrays of smaller crystals as an excellent solution. PNNL has developed two similar HPGe arrays for two very different applications. One array, the Multisensor Aerial Radiation Survey (MARS) detector is a fieldable array that has been tested on trucks, boats, and helicopters. The CASCADES HPGe array is an array designed to assay samples in a low background environment. The history of HPGe arrays at PNNL and the development of MARS and CASCADES will be detailed in this paper along with some of the other applications of HPGe at PNNL.

arrays↗

Laser Mass Spectrometry in Planetary Science

Knowing the chemical, elemental, and isotopic composition of planetary objects allows the study of their origin and evolution within the context of our solar system. Exploration plans in planetary research of several space agencies consider landing spacecraft for future missions. Although there have been successful landers in the past, more landers are foreseen for Mars and its moons, Venus, the jovian moons, and asteroids. Furthermore, a mass spectrometer on a landed spacecraft can assist in the sample selection in a sample-return mission and provide mineralogical context, or identify possible toxic soils on Mars for manned Mars exploration. Given the resources available on landed spacecraft mass spectrometers, as well as any other instrument, have to be highly miniaturised.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SuperCam One Step Closer to Mars

The SuperCam instrument -- designed, built and tested at Los Alamos National Laboratory in partnership with the French Space Agency -- and destined for the exploration of Mars has completed testing and evaluation at Los Alamos and is on its way to the Jet Propulsion Laboratory in California for full system integration. SuperCam will be one of two Los Alamos instruments on the next rover, called Mars 2020, an upgraded version of the current rover on Mars, Curiosity. SuperCam consists of a "mast unit" and "body unit, the mast unit, mounted on a mast on the exterior of the rover, is essentially a telescope with a laser, an extremely advanced version of Laser Induced Breakdown Spectroscopy, or LIBS, a technology invented at Los Alamos. The laser blasts a tiny portion of a geological formation, both rocks and soils on Mars, creating a plasma. The telescope then captures the spectra of the light emitted by the plasma. The body unit, mounted inside the body of the rover, is essentially a sophisticated spectrometer, and uses the light spectra to determine both the elemental and molecular composition of the sample, along with physical properties like hardness. Launch of the Mars 2020 mission is scheduled for late July, 2020, followed by the landing on Mars in February of 2021.

2020↗

A comprehensive evaluation of various sensitivity analysis methods: A case study with a hydrological model

Sensitivity analysis (SA) is a commonly used approach for identifying important parameters that dominate model behaviors. We use a newly developed software package, a Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), to evaluate the effectiveness and efficiency of ten widely used SA methods, including seven qualitative and three quantitative ones. All SA methods are tested using a variety of sampling techniques to screen out the most sensitive (i.e., important) parameters from the insensitive ones. The Sacramento Soil Moisture Accounting (SAC-SMA) model, which has thirteen tunable parameters, is used for illustration. The South Branch Potomac River basin near Springfield, West Virginia in the U.S. is chosen as the study area. The key findings from this study are: (1) For qualitative SA methods, Correlation Analysis (CA), Regression Analysis (RA), and Gaussian Process (GP) screening methods are shown to be not effective in this example. Morris One-At-a-Time (MOAT) screening is the most efficient, needing only 280 samples to identify the most important parameters, but it is the least robust method. Multivariate Adaptive Regression Splines (MARS), Delta Test (DT) and Sum-Of-Trees (SOT) screening methods need about 400–600 samples for the same purpose. Monte Carlo (MC), Orthogonal Array (OA) and Orthogonal Array based Latin Hypercube (OALH) are appropriate sampling techniques for them; (2) For quantitative SA methods, at least 2777 samples are needed for Fourier Amplitude Sensitivity Test (FAST) to identity parameter main effect. McKay method needs about 360 samples to evaluate the main effect, more than 1000 samples to assess the two-way interaction effect. OALH and LPτ (LPTAU) sampling techniques are more appropriate for McKay method. For the Sobol' method, the minimum samples needed are 1050 to compute the first-order and total sensitivity indices correctly. These comparisons show that qualitative SA methods are more efficient but less accurate and robust than quantitative ones.

58 GEOSCIENCES↗

Evidence of feasible hardness test on Mars using ratio of ionic/neutral emission intensities measured with laser-induced breakdown spectroscopy in low pressure CO{sub 2} ambient gas

An experimental study is conducted on the possibility and viability of performing hardness measurement of the various stone and chert samples in low pressure (600 Pa) CO{sub 2} ambient gas, a condition that is encountered in the Mars atmosphere. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from the samples with different degrees of hardness. This technique is developed in light of the role of the shock wave in the generation of a laser-induced plasma. It was previously shown that the speed of the shock front depends on the hardness of the sample, and a positive relationship was found between the speed of the shock front and the ionization rate of the ablated atoms. Hence, the ratio of the intensity between the Mg II 279.5 nm and Mg I 285.2 nm emission lines detected from the laser-induced plasma can be used to estimate the hardness of a material. In fact, it is shown that the ratio changes linearly with respect to changes of sample hardness. The result has thus demonstrated the feasibility and viability of using LIBS for non contact hardness measurement on Mars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ensemble methods for quantification of potassium oxide in ChemCam Mars and laboratory spectra

In this paper we test new approaches for predicting the amount of element oxides in rock samples from the ChemCam instrument suite onboard the NASA Curiosity rover by focusing on K 2 O. Using the expanded dataset compiled by Gasda et al. (2021) with and without the Earth to Mars (E2M and NoE2M) transformation discussed in Clegg et al. (2017) we trained blended submodels using the “double blending” technique and compared these to ensemble methods (Random Forest, ExtraTrees, and Gradient Boosting Regression). We found that ensemble methods performed similar to blended submodels when looking at RMSE-P on the laboratory spectra and provided significant advantages when looking at spectra coming from Mars. For the full model, blended submodels achieved an RMSE-P of 0.62 and 0.60 (E2M and NoE2M respectively) while Gradient Boosting Regression resulted in a slightly improved RMSE-P of 0.59 and 0.60. More importantly, by employing a local RMSE-P estimation technique where model performance is evaluated based on nearby test samples we found that using ensemble methods can lower the quantification limit for K 2 O from the current value of ≈0.6 wt% to ≈0.08 wt% using Extra Trees and Random Forest. This would allow for a much larger range of K 2 O values to be quantified on Mars with greater certainty given that most targets seen on Mars tend to have <1 wt% K2O. Finally, we used both Mean Decrease in Impurity (MDI) and permutation importance techniques to investigate the wavelengths used by the ensemble methods and found that they correspond to known potassium emission lines. This suggests that ensemble methods can provide an easier to train and improved alternative to blended submodels for predicting potassium compositions from Laser Induced Breakdown Spectroscopy (LIBS) data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of priority and emerging pollutants from aqueous media by adsorption onto synthetic organo-funtionalized high-charge swelling micas

Highlights: • Adsorption occurs in the interlayer space (C{sub 18}-Mica-4: 49.9 Å). • Pollutants remained sorbed into C{sub 18}-Mica-4 at least 7 days after treatment. • No sample pH adjustment neither NaCl addition is required. • Removal rates from 70% to 100% for most of the 18 pollutants in 24 h. • Applicability to wastewater, surface and tap water samples demonstrated. In this work, the removal of different types of emerging pollutants (four perfluoroalkyl compounds, two preservatives, three surfactants and nine pharmaceutical compounds) from aqueous solution by adsorption onto two novel synthetic clays, a high-charge swelling mica (Na-Mica-4) and an organo-functionalized mica (C{sub 18}-Mica−4), was evaluated. Na-Mica-4 and C{sub 18}-Mica− 4 were prepared and characterized by X-Ray diffraction, Zeta potential, specific surface area, thermogravimetric analysis and transmission electron microscopy, before and after adsorption experiments. The influence of the aqueous sample pH, salt addition and extraction time in the removal were evaluated. The results showed the high adsorption affinity of C{sub 18}-Mica-4 for most of the emerging pollutants analysed after a removal time of 24 h (14 out of 18 pollutants were effectively removed [70–100%]). A high correlation was observed between the log K{sub ow} of the selected emerging pollutants and the adsorption onto C{sub 18}-Mica-4. The results also indicate that adsorption occurs in the interlayer space. While the removal rates with Na-Mica-4 were in the range 8–97% after seven days, some of the compounds, perfluorobutanoic acid and most of pharmaceutically active compounds, were not adsorbed onto the high-charge mica. C{sub 18}-Mica− 4 was effectively used for the removal of contaminants from four types of water samples.

54 ENVIRONMENTAL SCIENCES↗

Imaging of Vanadium in Microfossils: A New Potential Biosignature

Being able to distinguish unambiguously the biogenicity of microfossil-like structures in the ancient rock record is a fundamental predicament facing Archean paleobiologists and astrobiologists. Therefore, novel methods for discriminating biological from non-biological chemistries of microfossil-like structures are of the utmost importance in the search for evidence of early life on Earth. This too, is important for the search for life on Mars; either by in situ analyses via rovers, or sample return missions for future analysis here on Earth. Here, we report the application of synchrotron X-ray fluorescence imaging of vanadium, within thermally altered organic-walled microfossils of bona fide biological origin. From our data, we demonstrate that vanadium is present within microfossils of undisputable biological origin. It is well known in the organic geochemistry literature, that elements such as vanadium are enriched and contained within crude oils, asphalts, and black shales that have been formed by diagensis of biological organic material. It has been demonstrated that the origin of vanadium is due to the diagenetic alteration of precursor chlorophyll and heme porphyrin pigment compounds from living organisms. Here, we propose that taken together, microfossil-like morphology, carbonaceous composition, and the presence of vanadium could be used in tandem as a biosignature to ascertain the biogenecity of putative microfossil-like structures.

59 BASIC BIOLOGICAL SCIENCES↗