Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An evaluation of the maximum tag burden for implantation of acoustic transmitters in juvenile Chinook salmon

Abstract.—The influence of a surgically implanted acoustic micro-transmitter and passive integrated transponder (PIT) tag on the growth and survival of hatchery-reared juvenile Chinook salmon was examined. Growth and survival were compared between treatment (implanted) and control fish within three fork length (FL) size groups (80-89, 90-99, and 100-109 mm). The acoustic micro-transmitter and PIT tag implanted in our study had a combined weight of 0.74 g. Weights of study fish ranged from 4.7 to 16.3 g for treatment fish and from 5.1 to 16.8 g for control fish. The burden for the combined acoustic and PIT tag experienced by implanted fish ranged from 8.8% to 15.7% for the 80-89 mm FL group, 6.0-10.9% for the 90-99 mm FL group, and 4.5-8.6% for the 100-109 mm FL group. Results indicated that growth and survival were size-dependent among implanted juvenile Chinook salmon. Significant differences in growth rate and survival were observed between treatment and control fish in the 80-89 mm FL group. Within this group, growth of fish smaller than 88.5 mm FL (tag burden > 10.0%) was negatively affected by the implantation or presence of an acoustic micro-transmitter and PIT tag. Survival of fish in the 90-99 mm FL group did not differ between treatment and control fish. However, survival of implanted fish within this size group that were smaller than 97.2 mm FL (tag burden > 7.4%) was negatively influenced. These results indicate that the burden of an acoustic micro-transmitter and PIT tag should be maintained at or below about 7.0% for studies that use hatchery-reared juvenile Chinook salmon.

54 ENVIRONMENTAL SCIENCES↗

Maximum thrust mode evaluation

Measured reductions in acceleration times which resulted from the application of the F-15 performance seeking control (PSC) maximum thrust mode during the dual-engine test phase is presented as a function of power setting and flight condition. Data were collected at altitudes of 30,000 and 45,000 feet at military and maximum afterburning power settings. The time savings for the supersonic acceleration is less than at subsonic Mach numbers because of the increased modeling and control complexity. In addition, the propulsion system was designed to be optimized at the mid supersonic Mach number range. Recall that even though the engine is at maximum afterburner, PSC does not trim the afterburner for the maximum thrust mode. Subsonically at military power, time to accelerate from Mach 0.6 to 0.95 was cut by between 6 and 8 percent with a single engine application of PSC, and over 14 percent when both engines were optimized. At maximum afterburner, the level of thrust increases were similar in magnitude to the military power results, but because of higher thrust levels at maximum afterburner and higher aircraft drag at supersonic Mach numbers the percentage thrust increase and time to accelerate was less than for the supersonic accelerations. Savings in time to accelerate supersonically at maximum afterburner ranged from 4 to 7 percent. In general, the maximum thrust mode has performed well, demonstrating significant thrust increases at military and maximum afterburner power. Increases of up to 15 percent at typical combat-type flight conditions were identified. Thrust increases of this magnitude could be useful in a combat situation.

Orme, John S.↗

Atmosphere Entries with Vehicle Lift-Drag Ratio Modulated to Limit Deceleration and Rate of Deceleration: Vehicles with Maximum Lift-Drag Ratio of 0.5

An analysis has been made of atmosphere entries for which the vehicle lift-drag ratio was modulated to maintain specified maximum decelerations and/or maximum deceleration rates. The part of the vehicle drag polar used during modulation was from maximum lift coefficient to minimum drag coefficient. The entries were at parabolic velocity and the vehicle maximum lift-drag ratio was 0.5. Two-dimensional trajectory calculations were made for a nonrotating, spherical earth with an exponential atmosphere. The results of the analysis indicate that for a given initial flight-path angle, modulation generally resulted in a reduction of the maximum deceleration to 60 percent of the unmodulated value or a reduction of maximum deceleration rate to less than 50 percent of the unmodulated rate. These results were equivalent, for a maximum deceleration of 10 g, to lowering the undershoot boundary 24 miles with a resulting decrease in total convective heating to the stagnation point of 22 percent. However, the maximum convective heating rate was increased 18 percent; the maximum radiative heating rate and total radiative heating were each increased about 10 percent.

Katzen, Elliott D.↗

Gauging the Nearness and Size of Cycle Maximum

A simple method for monitoring the nearness and size of conventional cycle maximum for an ongoing sunspot cycle is examined. The method uses the observed maximum daily value and the maximum monthly mean value of international sunspot number and the maximum value of the 2-mo moving average of monthly mean sunspot number to effect the estimation. For cycle 23, a maximum daily value of 246, a maximum monthly mean of 170.1, and a maximum 2-mo moving average of 148.9 were each observed in July 2000. Taken together, these values strongly suggest that conventional maximum amplitude for cycle 23 would be approx. 124.5, occurring near July 2002 +/-5 mo, very close to the now well-established conventional maximum amplitude and occurrence date for cycle 23-120.8 in April 2000.

Wilson, Robert M.↗

Modeling Validation of Mechanical and Thermal Borehole Breakouts From Polyaxial Laboratory Tests to Determine Maximum Horizontal in Situ Stress

To accurately assess rock behavior in the deep subsurface, it is necessary to measure the in situ stress directions and magnitudes. The current methods for measuring the in situ stress state in the deep subsurface primarily include hydraulic fracturing tests (i.e., the minimum horizontal stress) or occasionally observing existing compressive borehole breakouts (i.e., the maximum horizontal stress) that have occurred naturally from drilling. If there are no existing compressive breakouts in a borehole, the maximum horizontal in situ stress cannot be estimated with much confidence. In response to this data gap, a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. In support of developing the thermal breakout technology, polyaxial laboratory tests have been performed on small-scale boreholes within rock blocks where mechanically- and thermally-induced borehole breakouts have been created. Numerical models along with the principal of superposition were created and used to analyze the polyaxial laboratory tests to predict the maximum horizontal stress, given the same data that would be obtained in an actual subsurface borehole thermal breakout test. Multiple failure criteria were used to evaluate the best prediction of the breakout onset and maximum horizontal stress. The maximum horizontal stress predictions were compared to the actual maximum horizontal stress applied at breakout using acoustic events recorded from emission sensors in the polyaxial tests. The results showed consistent results that could be used to refine the modeling approach and failure criterion that are used to make the maximum horizontal stress predictions. This study provided insight and validation for the thermal breakout stress measurement concept.

Jones, Matt↗

Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy of protons, immediately prior to entry into the patient, that must be reached by the treatment system. The commonly used value for the maximum kinetic energy required for a medical proton accelerator is 250 MeV, but it has not been demonstrated that this energy is indeed necessary to treat all or most patients eligible for proton therapy. This article quantifies the maximum kinetic energy of protons, immediately prior to entry into the patient, necessary to treat a given percentage of patients with rotational proton therapy, and examines the impact of this energy threshold on the cost and feasibility of a compact, gantry-mounted proton accelerator treatment system. One hundred randomized treatment plans from patients treated with IMRT were analyzed. The maximum radiological pathlength from the surface of the patient to the distal edge of the treatment volume was obtained for 180 deg. continuous arc proton therapy and for 180 deg. split arc proton therapy (two 90 degree sign arcs) using CT profiles from the Pinnacle (Philips Medical Systems, Madison, WI) treatment planning system. In each case, the maximum kinetic energy of protons, immediately prior to entry into the patient, that would be necessary to treat the patient was calculated using proton range tables for various media. In addition, Monte Carlo simulations were performed to quantify neutron production in a water phantom representing a patient as a function of the maximum proton kinetic energy achievable by a proton treatment system. Protons with a kinetic energy of 240 MeV, immediately prior to entry into the patient, were needed to treat 100% of patients in this study. However, it was shown that 90% of patients could be treated at 198 MeV, and 95% of patients could be treated at 207 MeV. Decreasing the proton kinetic energy from 250 to 200 MeV decreases the total neutron energy fluence produced by stopping a monoenergetic pencil beam in a water phantom by a factor of 2.3. It is possible to significantly lower the requirements on the maximum kinetic energy of a compact proton accelerator if the ability to treat a small percentage of patients with rotational therapy is sacrificed. This decrease in maximum kinetic energy, along with the corresponding decrease in neutron production, could lower the cost and ease the engineering constraints on a compact proton accelerator treatment facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of non-premixed oxygen-enhanced combustion: I. The presence of appreciable oxygen at the location of maximum temperature

The presence of appreciable molecular oxygen at the location of maximum temperature has been observed in non-premixed oxygen-enhanced combustion (OEC) processes, specifically in flames having a high stoichiometric mixture fraction (Z{sub st}) produced with diluted fuel and oxygen-enrichment. For conventional fuel-air flames, key features of the flame are consistent with the flame sheet approximation (FSA). In particular, the depletion of O{sub 2} at the location of maximum temperature predicted by the FSA correlates well with the near-zero O{sub 2} concentration measured at this location for conventional fuel-air flames. In contradistinction, computational analysis with detailed kinetics demonstrates that for OEC flames at high Z{sub st}: (1) there is an appreciable concentration of O{sub 2} at the location of maximum temperature and (2) the maximum temperature is not coincident with the location of global stoichiometry, O{sub 2} depletion, or maximum heat release. We investigate these phenomena computationally in three non-premixed ethylene flames at low, moderate, and high Z{sub st}, but with equivalent adiabatic flame temperatures. Results demonstrate that the location of O{sub 2} depletion occurs in the vicinity of global stoichiometry for flames of any Z{sub st} and that the presence of appreciable O{sub 2} at the location of maximum temperature for high Z{sub st} flames is caused by a shift in the location of maximum temperature relative to the location of O{sub 2} depletion. This shifting is attributed to: (1) finite-rate multi-step chemistry resulting in exothermic heat release that is displaced from the location of O{sub 2} depletion and (2) the relative location of the heat release region with respect to the fuel and oxidizer boundaries in mixture fraction space. A method of superposition involving a variation of the flame sheet approximation with two heat sources is shown to be sufficient in explaining this phenomenon. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of maximum strain of steel beam structures based on average strains from vibrating wire strain gages

In structural health monitoring, the safety of steel beam structures can be assessed by comparing the measured maximum stress and the allowable stress of the beam calculated by a design code. For the case of a steel beam subjected to variable lateral loadings, many difficulties exist in measuring the maximum stress in a beam with point sensors that can measure the strain only at a local point of a beam since the location and magnitude of the maximum stress induced in a beam by the loading change. Although traditional strain sensors can measure the strain only at a local point, a vibrating wire strain gage (VWSG) that measures integrated strains over its gage length can consider the variation of strains due to variable loadings. This paper presents an estimation model to determine the maximum strains or stresses in a steel beam based on average strains measured using VWSGs. The model is derived by defining the relation between the average strains measured using VWSGs and the maximum strains of beams. The model is experimentally tested by comparing the maximum strain directly obtained from electrical strain gages and the estimated maximum strain based on the average strain from VWSGs.

42 ENGINEERING↗

On the horizontal distribution of the equatorial thermospheric midnight temperature maximum and its seasonal variation

The temperature measurements taken with the NATE experiment on the Atmosphere Explorer-E satellite during 1977 and 1978 are used to obtain the horizontal two-dimensional distribution of the thermospheric nighttime temperature maximum between latitudes 19.8 deg. south and 19.8 deg. north in the altitude range from 250 to about 370 km. The data are used to generate temperature maps for the four seasons. The maps show that the nighttime temperature maximum often occurs first at the geographic equator, and shows a tendency to be largest there. A seasonal rotation of the distribution of the maximum is observed in which the maximum occurs in the summer hemisphere before it occurs in winter. The summer maximum is significantly larger than the winter maximum. The local time of occurrence of the maximum in either hemisphere shows an annual oscillation about local midnight with an amplitude of about 3 hours. The observations indicate that the nighttime temperature oscillates with higher frequencies and amplitudes in the summer hemisphere, thus suggesting that the semidiurnal and higher order tidal modes are stronger in that hemisphere.

Herrero, F. A.↗

Water availability modulates maximum canopy heights of low-elevation Amazonian second-growth forests

Tropical second-growth forests of the Amazon sequester large amounts of carbon and are important carbon sinks, contributing substantially to climate change mitigation, biodiversity conservation, and providing crucial ecosystem services. Deforestation due to selective logging and shifting cultivation is expanding second-growth forest areas in tropical forest regions, which if well managed, regenerate rapidly over time. Maximum forest canopy height is an important metric of biomass and carbon accumulation in second-growth forests and is strongly influenced by water availability. The water limitation hypothesis explains the positive influence of water availability on maximum tree heights and has been examined and demonstrated at a small-scale using field data, and at a global scale, with limited accuracy, using remote sensing data in tropical ecosystems. However, this hypothesis concerning maximum canopy height has not been much studied at regional and national scales for tropical second-growth forests. In this study, we leveraged NASA GEDI spaceborne lidar data across the Brazilian Amazon and derived second-growth forest relative height metrics for delineating the influence of water availability, second-growth forest age, and topographic elevation on maximum canopy height. Water availability was found to significantly influence the maximum canopy height of second-growth forest trees, of age range from 30 to 35 years, at elevations less than 500 m and maximum precipitation thresholds of 1500 mm. Our results indicate that changing precipitation patterns or increased drought conditions under different climate change regimes could impact forest structure, plant communities, ecosystem functioning, and carbon sequestration capabilities of tropical second-growth forests in the Amazon.

Carbon sequestration↗

Heterogeneity-corrected vs -uncorrected critical structure maximum point doses in breast balloon brachytherapy

Recent studies have reported potentially clinically meaningful dose differences when heterogeneity correction is used in breast balloon brachytherapy. In this study, we report on the relationship between heterogeneity-corrected and -uncorrected doses for 2 commonly used plan evaluation metrics: maximum point dose to skin surface and maximum point dose to ribs. Maximum point doses to skin surface and ribs were calculated using TG-43 and Varian Acuros for 20 patients treated with breast balloon brachytherapy. The results were plotted against each other and fit with a zero-intercept line. Max skin dose (Acuros) = max skin dose (TG-43) ⁎ 0.930 (R{sup 2} = 0.995). The average magnitude of difference from this relationship was 1.1% (max 2.8%). Max rib dose (Acuros) = max rib dose (TG-43) ⁎ 0.955 (R{sup 2} = 0.9995). The average magnitude of difference from this relationship was 0.7% (max 1.6%). Heterogeneity-corrected maximum point doses to the skin surface and ribs were proportional to TG-43-calculated doses. The average deviation from proportionality was 1%. The proportional relationship suggests that a different metric other than maximum point dose may be needed to obtain a clinical advantage from heterogeneity correction. Alternatively, if maximum point dose continues to be used in recommended limits while incorporating heterogeneity correction, institutions without this capability may be able to accurately estimate these doses by use of a scaling factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

On estimations of maximum and average interfacial temperature rise in sliding elliptical contacts

his study considers the approaches of Blok and Jaeger for the estimation of maximum and average temperatures in sliding elliptical contacts with both uniform and semi-ellipsoidal (Hertzian) heat distributions. The accuracy of each of these methods, which are based on single-point temperature matching between contacting bodies, is assessed relative to a numerical solution of the heat partition problem developed in a previous work, which imposed temperature matching at all nodal points. Comparisons are made for a wide range of Peclet numbers, as well as for moderate ranges of thermal conductivity ratio and elliptical ratio. It is found that the application of Blok's hypothesis yields remarkably accurate predictions of the maximum interfacial temperature, with typical errors less than 3%, whereas the hypothesis of Jaeger leads to predictions of the average interfacial temperature that have typical errors of around 6%. The authors also assess the accuracy of approximate formula developed by Tian and Kennedy to predict the maximum temperature at the interface for the case of sliding circular contacts and find the error to be no more than 2.6% for the full range of Peclet number. Further, the authors of the current study use fundamental heat source solutions developed by Tian and Kennedy to arrive at formulae for average temperature rise for circular contacts that are analogous to the Tian and Kennedy maximum temperature rise formulae. It is found that the formulae for computing the average interfacial temperature rise are also quite accurate, but have slightly more error than the maximum temperature rise formulae. Finally, in the present work, extensions are suggested to the maximum and average temperature rise formulae of Tian and Kennedy to include the effects of elliptical contact geometry. It is found that these formulae are at least 91% accurate for elliptical ratios between 0.4 and 5.0.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-539: Maximum Energy of Helium and Carbon Ions Clinically Needed for Spine, Lung, Prostate and Pancreas Cancer

Purpose: Maximum available kinetic energy of accelerated heavy ions is a critical parameter to consider during the establishment of a heavy ion therapy center. It dictates the maximum range in tissue and determines the size and cost of ion gantry. We have started planning our heavy ion therapy center and we report on the needed ion range. Methods: We analyzed 50 of random SBRT-spine, SBRT- lung, prostate and pancreatic cancer patients from our photon clinic. In the isocentric axial CT cut we recorded the maximum water equivalent depth (WED4Field) of PTV’s most distal edge in four cardinal directions and also in a beam direction that required the largest penetration, WEDGantry. These depths were then used to calculate the percentage of our patients we would be able to treat as a function of available maximum carbon and helium beam energy. Based on the Anterior-Posterior WED for lung patients and the maximum available ion energy we estimated the largest possible non-coplanar beam entry angle φ (deviation from vertical) in the isocentric vertical sagittal plane. Results: We found that if 430MeV/u C-12, equivalently 220MeV/u He-4, beams are available, more than 96% (98%) of all patients can be treated without any gantry restrictions (in cardinals angles only) respectively. If the energy is reduced to 400MeV/u C-12, equivalently 205MeV/u He-4, the above fractions reduce to 80% (87%) for prostate and 88% (97%) for other sites. This 7% energy decrease translates to almost 5% gantry size and cost decrease for both ions. These energy limits in combination with the WED in the AP direction for lung patients resulted in average non-coplanar angles of φ430MeV/u = 68°±8° and φ400MeV/u = 65°±10° if nozzle clearance permits them. Conclusion: We found that the two worldwide most common maximum carbon beam energies will treat above 80% of all our patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-remnant and maximum-voxel SPECT/CT dosimetry in {sup 131}I-NaI treatments of differentiated thyroid cancer

Purpose: To investigate the possible differences between SPECT/CT based whole-remnant and maximum-voxel dosimetry in patients receiving radio-iodine ablation treatment of differentiated thyroid cancer (DTC). Methods: Eighteen DTC patients were administered 1.11 GBq of {sup 131}I-NaI after near-total thyroidectomy and rhTSH stimulation. Two patients had two remnants, so in total dosimetry was performed for 20 sites. Three SPECT/CT scans were performed for each patient at 1, 2, and 3–7 days after administration. The activity, the remnant mass, and the maximum-voxel activity were determined from these images and from a recovery-coefficient curve derived from experimental phantom measurements. The cumulated activity was estimated using trapezoidal-exponential integration. Finally, the absorbed dose was calculated using S-values for unit-density spheres in whole-remnant dosimetry and S-values for voxels in maximum-voxel dosimetry. Results: The mean absorbed dose obtained from whole-remnant dosimetry was 40 Gy (range 2–176 Gy) and from maximum-voxel dosimetry 34 Gy (range 2–145 Gy). For any given patient, the activity concentrations for each of the three time-points were approximately the same for the two methods. The effective half-lives varied (R = 0.865), mainly due to discrepancies in estimation of the longer effective half-lives. On average, absorbed doses obtained from whole-remnant dosimetry were 1.2 ± 0.2 (1 SD) higher than for maximum-voxel dosimetry, mainly due to differences in the S-values. The method-related differences were however small in comparison to the wide range of absorbed doses obtained in patients. Conclusions: Simple and consistent procedures for SPECT/CT based whole-volume and maximum-voxel dosimetry have been described, both based on experimentally determined recovery coefficients. Generally the results from the two approaches are consistent, although there is a small, systematic difference in the absorbed dose due to differences in the S-values, and some variability due to differences in the estimated effective half-lives, especially when the effective half-life is long. Irrespective of the method used, the patient absorbed doses obtained span over two orders of magnitude.

60 APPLIED LIFE SCIENCES↗