Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Photo-z optimization for measurements of the BAO radial scale

Baryon Acoustic Oscillations (BAO) in the radial direction offer a method to directly measure the Universe expansion history, and to set limits to space curvature when combined to the angular BAO signal. In addition to spectroscopic surveys, radial BAO might be measured from accurate enough photometric redshifts obtained with narrow-band filters. We explore the requirements for a photometric survey using Luminous Red Galaxies (LRG) to competitively measure the radial BAO signal and discuss the possible systematic errors of this approach. Using the LRG spectra obtained from SDSS, we find that the optimal system consists of {approx} 30 filters of width {Delta}{lambda}/{lambda} {approx} 0.02. A S/N>20 is generally necessary at the filters on the red side of the Balmer-break to reach the target photometric accuracy {sigma}{sub z} = 0.003(1+z) for measuring radial BAO. The presence of outliers can significantly degrade this: in any practical application, being able to efficiently remove outliers may require ancillary observations. We estimate that a 5-year survey in a dedicated telescope with etendue in excess of 60 m{sup 2} deg{sup 2} would be necessary to obtain a high enough density of galaxies to measure the radial BAO with shot noise smaller than cosmic variance up to z = 0.85. We conclude that spectroscopic surveys have a superior performance than photometric ones for measuring BAO in the radial direction.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum Metrology of Noisy Spreading Channels

We provide the optimal measurement strategy for a class of noisy channels that reduce to the identity channel for a specific value of a parameter (spreading channels). We provide an example that is physically relevant: the estimation of the absolute value of the displacement in the presence of phase randomizing noise. Surprisingly, this noise does not affect the effectiveness of the optimal measurement. We show that, for small displacement, a squeezed vacuum probe field is optimal among strategies with same average energy. A squeezer followed by photodetection is the optimal detection strategy that attains the quantum Fisher information, whereas the customarily used homodyne detection becomes useless in the limit of small displacements, due to the same effect that gives Rayleigh’s curse in optical superresolution. There is a quantum advantage: a squeezed or a Fock state with N average photons allow to asymptotically estimate the parameter with a N better precision than classical states with same energy.

Górecki, Wojciech↗

Automated suppression of errors in LTP-II slope measurements of x-ray optics. Part 2: Specification for automated rotating/flipping/aligning system

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. With this series of LSBL Notes, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We provide details of the system?s design, operational control and data acquisition. The high performance of the system is demonstrated via the results of high precision measurements with a spherical test mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated suppression of errors in LTP-II slope measurements with x-ray optics. Part1: Review of LTP errors and methods for the error reduction

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. With this series of LSBL Notes, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We provide details of the system’s design, operational control and data acquisition. The high performance of the system is demonstrated via the results of high precision measurements with a spherical test mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating time in quantum chaotic systems and black holes

We characterize new universal features of the dynamics of chaotic quantum many-body systems, by considering a hypothetical task of "time estimation". Most macroscopic observables in a chaotic system equilibrate to nearly constant late-time values. Intuitively, it should become increasingly difficult to estimate the precise value of time by making measurements on the state. We use a quantity called the Fisher information from quantum metrology to quantify the minimum uncertainty in estimating time. Due to unitarity, the uncertainty in the time estimate does not grow with time if we have access to optimal measurements on the full system. Restricting the measurements to act on a small subsystem or to have low computational complexity leads to results expected from equilibration, where the time uncertainty becomes large at late times. With optimal measurements on a subsystem larger than half of the system, we regain the ability to estimate the time very precisely, even at late times. Hawking's calculation for the reduced density matrix of the black hole radiation in semiclassical gravity contradicts our general predictions for unitary quantum chaotic systems. Hawking's state always has a large uncertainty for attempts to estimate the time using the radiation, whereas our general results imply that the uncertainty should become small after the Page time. This gives a new version of the black hole information loss paradox in terms of the time estimation task. By restricting to simple measurements on the radiation, the time uncertainty becomes large. This indicates from a new perspective that the observations of computationally bounded agents are consistent with the semiclassical effective description of gravity.

Black holes↗

Optimal Cosmological Measurements with Weak Gravitational Lensing

The goal of the research carried out under this DOE award was to develop methodology to ensure that the upcoming Large Synoptic Survey Telescope (LSST) survey achieves its goals of robustly constraining dark energy using weak gravitational lensing. This included developing more optimal ways to use the data on its own or in combination with other surveys, better ways of detecting and reducing the impact of systematic errors, and demonstrating that methodology on existing data.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-DE-201-01: BEST IN PHYSICS (THERAPY): A Fast Multi-Target Inverse Treatment Planning Strategy Optimizing Dosimetric Measures for High-Dose-Rate (HDR) Brachytherapy

Purpose: Inverse treatment planning (ITP) for interstitial HDR brachytherapy of gynecologic cancers seeks to maximize coverage of the clinical target volumes (tumor and vagina) while respecting dose-volume-histogram related dosimetric measures (DMs) for organs at risk (OARs). Commercially available ITP tools do not support DM-based planning because it is computationally too expensive to solve. In this study we present a novel approach that allows fast ITP for gynecologic cancers based on DMs for the first time. Methods: This novel strategy is an optimization model based on a smooth DM-based objective function. The smooth approximation is achieved by utilizing a logistic function for the evaluation of DMs. The resulting nonconvex and constrained optimization problem is then optimized with a BFGS algorithm. The model was evaluated using the implant geometry extracted from 20 patient treatment plans under an IRB-approved retrospective study. For each plan, the final DMs were evaluated and compared to the original clinical plans. The CTVs were the contoured tumor volume and the contoured surface of the vagina. Statistical significance was evaluated with a one-sided paired Wilcoxon signed-rank test. Results: As did the clinical plans, all generated plans fulfilled the defined DMs for OARs. The proposed strategy showed a statistically significant improvement (p<0.001) in coverage of the tumor and vagina, with absolute improvements of related DMs of (6.9 +/− 7.9)% and (28.2 +/− 12.0)%, respectively. This was achieved with a statistically significant (p<0.01) decrease of the high-dose-related DM for the tumor. The runtime of the optimization was (2.3 +/− 2.0) seconds. Conclusion: We demonstrated using clinical data that our novel approach allows rapid DM-based optimization with improved coverage of CTVs with fewer hot spots. Being up to three orders of magnitude faster than the current clinical practice, the method dramatically shortens planning time.

60 APPLIED LIFE SCIENCES↗

Optimal Energy Measurement in Nonlinear Systems: An Application of Differential Geometry

Design of TES microcalorimeters requires a tradeoff between resolution and dynamic range. Often, experimenters will require linearity for the highest energy signals, which requires additional heat capacity be added to the detector. This results in a reduction of low energy resolution in the detector. We derive and demonstrate an algorithm that allows operation far into the nonlinear regime with little loss in spectral resolution. We use a least squares optimal filter that varies with photon energy to accommodate the nonlinearity of the detector and the non-stationarity of the noise. The fitting process we use can be seen as an application of differential geometry. This recognition provides a set of well-developed tools to extend our work to more complex situations. The proper calibration of a nonlinear microcalorimeter requires a source with densely spaced narrow lines. A pulsed laser multi-photon source is used here, and is seen to be a powerful tool for allowing us to develop practical systems with significant detector nonlinearity. The combination of our analysis techniques and the multi-photon laser source create a powerful tool for increasing the performance of future TES microcalorimeters.

Nonlinear response↗

Optimal Transport as a Tool for Scientific Discovery in Radiation Biology

This report summarizes findings from research conducted for the “Exploration of the Poten tial for Artificial Intelligence and Machine Learning to Advance Low-Dose Radiation Biology Re search” (RadBio-AI) program, supported by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research, under Awards KP1601011/FWP CC121 and KP1601017/FWP CC121. The research reported here was undertaken in an effort to assess the potential of optimal measure transport methods as components within the larger scope of a com putational framework envisioned to support research in the radiation biology domain. Within this effort, our interest centered on enabling a unified generic framework where probabilistic modeling, inference, and statistical learning can be carried out for a wide range of data distributions. As described next in Section 1 (and in more detail in our original publication), optimal measure transport offers the possibility of such unified approach.

97 MATHEMATICS AND COMPUTING↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimal phase estimation with arbitrary a priori knowledge

The optimal-phase estimation strategy is derived when partial a priori knowledge on the estimated phase is available. The solution is found with the help of the most famous result from the entanglement theory: the positive partial transpose criterion. The structure of the optimal measurements, estimators, and the optimal probe states is analyzed. This Rapid Communication provides a unified framework bridging the gap in the literature on the subject which until now dealt almost exclusively with two extreme cases: almost perfect knowledge (local approach based on Fisher information) and no a priori knowledge (global approach based on covariant measurements). Special attention is paid to a natural a priori probability distribution arising from a diffusion process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing BAO measurements with non-linear transformations of the Lyman-α forest

We explore the effect of applying a non-linear transformation to the Lyman-α forest transmitted flux F=e{sup −τ} and the ability of analytic models to predict the resulting clustering amplitude. Both the large-scale bias of the transformed field (signal) and the amplitude of small scale fluctuations (noise) can be arbitrarily modified, but we were unable to find a transformation that increases significantly the signal-to-noise ratio on large scales using Taylor expansion up to the third order. In particular, however, we achieve a 33% improvement in signal to noise for Gaussianized field in transverse direction. On the other hand, we explore an analytic model for the large-scale biasing of the Lyα forest, and present an extension of this model to describe the biasing of the transformed fields. Using hydrodynamic simulations we show that the model works best to describe the biasing with respect to velocity gradients, but is less successful in predicting the biasing with respect to large-scale density fluctuations, especially for very nonlinear transformations.

79 ASTRONOMY AND ASTROPHYSICS↗

Frhodo: A program for simulating chemical kinetic measurements and optimizing kinetic mechanisms

Chemical kinetic simulations are frequently used to extract kinetic and mechanistic information from experimental data by fitting simulations to the data. For simple systems of consecutive single channel reactions this is a relatively straightforward task. However, as the complexity of the system increases and particularly for systems involving competitive multi-channel reactions manually optimizing a mechanism to obtain the best fits to a range of experimental data quickly becomes a time-intensive and challenging process, especially when rate coefficients have pressure and temperature dependencies. There is considerable potential for exploiting automated optimization methods to rapidly screen reaction mechanisms and optimize the fit by adjusting rate coefficients within well-defined constraints. A new chemical kinetics simulation program, Frhodo, has been developed for this purpose. The program allows either manual simulation of individual experiments or fully automated optimization against a range of experimental data by adjusting user selected reactions within user defined constraints. Frhodo incorporates machine learning-based optimization routines that work by either minimizing standardized residuals or through Bayesian parameter estimation. Frhodo's optimization capabilities are demonstrated by reexamining two previously studied systems of relevance to combustion. Dissociation of diacetyl followed by recombination of methyl radicals is an example of a sequence of single channel, consecutive reactions. Pyrolysis of 2-methyl furan exemplifies multi-channel, unimolecular reactions that are often encountered and have temperature and pressure dependencies in the rate coefficients of the channels and branching ratios between them. For both systems the optimization routines resulted in solutions similar to the original studies. Finally, comments are made on the strengths and limitations of the approach.

0D simulation↗

Optimization of measurements with pressure sensitive paints

Use of luminescent paints for the measurement of global pressures on wind tunnel model surfaces requires a full understanding of the inherent accuracy of the technique. Theoretical emission of the paint luminophor follows the well known Stern-Volmer relation. Inherent in this relation are fundamental limits to achievable sensitivity and accuracy. Equations for relative error in pressure as a function of relative signal intensity (emittance), relative error in pressure as a function of pressure, and the relationship between sensitivity and pressure are derived and represented graphically.

Oglesby, Donald M.↗