Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory [Nucl. Instr. and Meth. A 616, 212-223 (2010)]. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

47 OTHER INSTRUMENTATION↗

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

42 ENGINEERING↗

Measurement and Instrumentation

This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

instrument technology↗

A high precision instrument to measure angular and binocular deviation introduced by aircraft windscreens by using a shadow casting technique

Objects viewed through transparent sheets with residual non-parallelism and irregularity appear shifted and distorted. This distortion is measured in terms of angular and binocular deviation of an object viewed through the transparent sheet. The angular and binocular deviations introduced are particularly important in the context of aircraft windscreens and canopies as they can interfere with decision making of pilots especially while landing, leading to accidents. In this work, we have developed an instrument to measure both the angular and binocular deviations introduced by transparent sheets. This instrument is especially useful in the qualification of aircraft windscreens and canopies. It measures the deviation in the geometrical shadow cast by a periodic dot pattern trans-illuminated by the distorted light beam from the transparent test specimen compared to the reference pattern. Accurate quantification of the shift in the pattern is obtained by cross-correlating the reference shadow pattern with the specimen shadow pattern and measuring the location of the correlation peak. The developed instrument is handy to use and computes both angular and binocular deviation with an accuracy of less than {+-}0.1 mrad ( Almost-Equal-To 0.036 mrad) and has an excellent repeatability with an error of less than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision instrument for measuring the surface tension, viscosity and surface viscoelasticity of liquids using ripplon surface laser-light scattering with tunable wavelength selection

Here we describe our new high-precision instrument that simultaneously measures the surface tension, viscosity, and surface viscoelasticity of liquids. The instrument works on the ripplon surface-laser light scattering principle and operates with an automatically tunable selection of ripplon wavelength from 4 to 1500 μm, which corresponds to the frequency range of observing surface phenomena from approximately 400 Hz to 3 MHz in the case of water. The heterodyne technique instrument uses a reference laser beam which intersects at an arbitrarily adjustable angle with a vertically directed probing beam. For the determination of the wavelength of selected ripplons we substituted with the interference fringe spacing, measured using a high-resolution beam profiler. To extract reliable surface tension and viscosity data from the experimentally obtained spectrum shape for a selected wavelength of ripplon, we developed an algorithm to calculate the exact solution of the dispersion equation. The uncertainties of surface tension and viscosity measurement were confirmed through the measurement of seven pure Newtonian liquids at 25 °C measured with the selected wavelength of ripplon from 40 μm to 467 μm. To verify the genuine capability of the tunable wavelength selection of ripplon, we measured the surface elasticity of soluble surface molecular layers spread on pentanoic acid solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler

A new low budget slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought to operation at the ALS Optical Metrology Laboratory. The design, instrumental control and data acquisition system, initial alignment and calibration procedures, as well as the developed experimental precautions and procedures are described in detail. The capability of the DLTP to achieve sub-microradian surface slope metrology is verified via cross-comparison measurements with other high performance slope measuring instruments when measuring the same high quality test optics. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.

47 OTHER INSTRUMENTATION↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring the activity of BioBrick promoters using an in vivo reference standard

The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101) to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU) in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement conditions and instruments. Furthermore, these improvements are sufficient to begin to support the measurement of promoter activities across many laboratories. Additional in vivo reference standards for other types of biological functions would seem likely to have similar utility, and could thus improve research on the design, production, and reuse of standard biological parts.

59 BASIC BIOLOGICAL SCIENCES↗

Framework Application for Core Edge Transport Simulations (FACETS) Performance Analysis (Final Report)

The goal of the FACETS project (Framework Application for Core-Edge Transport Simulations) was to provide a multiphysics, parallel framework application (FACETS) that will enable whole-device modeling for the U.S. fusion program, to provide the modeling infrastructure needed for ITER, the next step fusion confinement device. Through use of modern computational methods, including component technology and object oriented design, FACETS is able to switch from one model to another for a given aspect of the physics in a flexible manner. This enables use of simplified models for rapid turnaround or high-fidelity models that can take advantage of the largest supercomputer hardware. FACETS does so in a heterogeneous parallel context, where different parts of the application execute in parallel by utilizing task farming, domain decomposition, and/or pipelining as needed and applicable. ParaTools, Inc. was tasked with supporting the performance analysis and tuning of the FACETS components and framework in order to achieve the parallel scaling goals of the project. The TAU Performance System® was used for instrumentation, measurement, archiving, and profile / tracing analysis. ParaTools, Inc. also assisted in FACETS performance engineering efforts. Through the use of the TAU Performance System, ParaTools provided instrumentation, measurement, analysis and archival support for the FACETS project. Performance optimization of key components has yielded significant performance speedups. TAU was integrated into the FACETS build for both the full coupled application and the UEDGE component. The performance database provided archival storage of the performance regression testing data generated by the project, and helped to track improvements in the software development.

97 MATHEMATICS AND COMPUTING↗

Design and Development of an Automated Instrument for Measuring Radioactivity in an Excavator Bucket - 16246

Increasing interest and emphasis is being given to the presence of radioactive contamination in the environment and the methods by which this contamination can be remediated. Radioactive contamination may arise from industrial process including the operation of nuclear facilities. It may also arise from the enhancement of naturally occurring radioactive material by industrial processes. An area of particular concern is the remediation of soil and rubble with radioactive contamination. Traditional methods of soil remediation involve sampling followed by the excavation of areas where contamination is found. The soil removal process is normally very inefficient and can involve multiple handling of excessive quantities of soil and ultimately an over estimate of the quantity of soil with radioactive contamination. In order to both minimize material handling and to reduce the final volume of contaminated material, which must be handled for disposal, a sensitive instrument has been developed and tested which is designed to measure the radioactive content of an excavator bucket. The instrument detector is positioned automatically just above the open top of the bucket and the measurement employs a high efficiency sodium iodide crystal which has a graded shadow shield to reduce the effect of background radioactivity. The measurement efficiency is enhanced as the detector is located in close proximity to the soil in the bucket and the thick steel shell of the bucket acts as a shield to further reduce the effect of background from the ground below. The method has obvious advantages over methods, which attempt to measure the potentially radioactive soil through the shielding provided by the thick steel bucket shell. As the first stage of the bucket measurement the excavator operator fills the bucket and locates it in a designated position with the open top of the bucket facing upwards, close to the operator cab. A measurement technician, located outside the danger area of the excavator boom, begins the measurement using a tablet computer with a wireless connection to the instrument. The shielded detector is moved from a storage position above the operator cab to the measurement position close to the open surface of the excavator bucket. Once the measurement is completed in typically one to two minutes, the detector is repositioned in its storage location and the measurement data is transmitted to the tablet computer. At this point the measurement technician makes the decision based on the measurement results as to how to disposition the bucket contents. Typically contaminated material will be transferred to a vehicle for off-site disposal. Alternatively, and this is the great advantage of this technique, uncontaminated material may be returned directly to the site of the excavation without the need for further handling. The development, detailed design and preliminary testing of the instrument are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intercomparison of airborne and surface-based measurements during the CLARIFY, ORACLES and LASIC field experiments

Data are presented from intercomparisons between two research aircraft, the FAAM BAe-146 and the NASA Lockheed P3, and between the BAe-146 and the surface-based DOE (Department of Energy) ARM (Atmospheric Radiation Monitoring) Mobile Facility at Ascension Island (8 S, 14.5W, a remote island in the mid-Atlantic). These took place from 17 August to 5 September 2017, during the African biomass burning season. The primary motivation was to give confidence in the use of data from multiple platforms with which to evaluate numerical climate models. The three platforms were involved in the CLouds-Aerosol-Radiation Interaction and Forcing for Year 2017 (CLARIFY-2017), ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES), and Layered Atlantic Smoke and Interactions with Clouds (LASIC) field experiments. Comparisons from flight segments on six days where the BAe-146 flew alongside the ARM facility on Ascension Island are presented, along with comparisons from wing-tip to wing-tip flight of the P3 and BAe-146 on 18 th August 2017. The intercomparison flight sampled a relatively clean atmosphere overlying a moderately polluted boundary layer, while the 6 fly-bys of the ARM site sampled both clean and polluted conditions 2–4 km upwind. We compare and validate characterisations of aerosol physical, chemical, and optical properties, atmospheric radiation, and cloud microphysics between platforms. We assess the performance of measurement instrumentation in the field, under conditions where sampling conditions are not tightly controlled as in laboratory measurements where calibrations are performed. Solar radiation measurements compared well between airborne platforms. Optical absorption coefficient measurements compared well across all three platforms, even though absolute magnitudes were often low (< 10 Mm -1 ) and close to the sensitivity limits of measurement instrumentation thereby confounding assessments of the comparability of absorption Ångström exponent characterisations. Aerosol absorption measurements from airborne platforms were more comparable than aircraft-to-ground observations. Scattering coefficient observations compared well between airborne platforms, but agreement with ground-based measurements was worse, potentially caused by small differences in sampling conditions or actual aerosol population differences. Chemical composition measurements followed a similar pattern, with better comparisons between the airborne platforms. Thermodynamics, aerosol, and cloud microphysical properties generally compared well.

54 ENVIRONMENTAL SCIENCES↗

PRIMA-X Final Report

The PRIMA-X (Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing) project is the successor of the DOE PRIMA (Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing) project, which addressed the challenge of creating a core measurement infrastructure that would serve as a common platform for both integrating leading parallel performance systems (notably TAU and Scalasca) and developing next-generation scalable performance tools. The PRIMA-X project shifts the focus away from refactorization of robust performance tools towards a re-targeting of the parallel performance measurement and analysis architecture for extreme scales. The massive concurrency, asynchronous execution dynamics, hardware heterogeneity, and multi-objective prerequisites (performance, power, resilience) that identify exascale systems introduce fundamental constraints on the ability to carry forward existing performance methodologies. In particular, there must be a deemphasis of per-thread observation techniques to significantly reduce the otherwise unsustainable flood of redundant performance data. Instead, it will be necessary to assimilate multi-level resource observations into macroscopic performance views, from which resilient performance metrics can be attributed to the computational features of the application. This requires a scalable framework for node-level and system-wide monitoring and runtime analyses of dynamic performance information. Also, the interest in optimizing parallelism parameters with respect to performance and energy drives the integration of tool capabilities in the exascale environment further. Initially, PRIMA-X was a collaborative project between the University of Oregon (lead institution) and the German Research School for Simulation Sciences (GRS). Because Prof. Wolf, the PI at GRS, accepted a position as full professor at Technische Universität Darmstadt (TU Darmstadt) starting February 1st, 2015, the project ended at GRS on January 31st, 2015. This report reflects the work accomplished at GRS until then. The work of GRS is expected to be continued at TU Darmstadt. The first main accomplishment of GRS is the design of different thread-level aggregation techniques. We created a prototype capable of aggregating the thread-level information in performance profiles using these techniques. The next step will be the integration of the most promising techniques into the Score-P measurement system and their evaluation. The second main accomplishment is a substantial increase of Score-P’s scalability, achieved by improving the design of the system-tree representation in Score-P’s profile format. We developed a new representation and a distributed algorithm to create the scalable system tree representation. Finally, we developed a lightweight approach to MPI wait-state profiling. Former algorithms either needed piggy-backing, which can cause significant runtime overhead, or tracing, which comes with its own set of scaling challenges. Our approach works with local data only and, thus, is scalable and has very little overhead.

97 MATHEMATICS AND COMPUTING↗

An in situ tensile test apparatus for polymers in high pressure hydrogen

Degradation of material properties by high-pressure hydrogen is an important factor in determining the safety and reliability of materials used in high-pressure hydrogen storage and delivery. Hydrogen damage mechanisms have a time dependence that is linked to hydrogen outgassing after exposure to the hydrogen atmosphere that makes ex situ measurements of mechanical properties problematic. Designing in situ measurement instruments for high-pressure hydrogen is challenging due to known hydrogen incompatibility with many metals and standard high-power motor materials like Nd. Here we detail the design and operation of a solenoid based in situ tensile tester under high-pressure hydrogen environments up to 5,000 psi. Here, modulus data from high-density polyethylene (HDPE) samples tested under high-pressure hydrogen are also reported as compared to baseline measurements taken in air.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗