Search NASA⌕ Search

SEARCH · Search NASA

Results for “Membrane resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Pentiptycene-based ladder polymers with configurational free volume for enhanced gas separation performance and physical aging resistance

Significance Gas separation membranes are an emerging energy-efficient alternative toward conventional, energy-intensive separation technologies such as cryogenic distillation. Ladder polymers with intrinsic microporosity show exceptional promise toward redefining state-of-the-art gas separation membranes due to their high permeability (throughput) and selectivity (separation efficiency). However, they are typically inhibited by major reductions in permeability over time due to collapsing membrane free volume (open space between polymer chains), forfeiting their greatest asset. This work explores a route toward enhanced aging resistance and overall separation performance by incorporating pentiptycene (an H-shaped scaffold containing five fused arene rings) into ladder-like polymers to incorporate natural, more permanent “micropores” that aren’t susceptible to densification of polymer chains that occurs over time in traditional microporous polymers.

36 MATERIALS SCIENCE↗

Proton Conducting Silicon Oxide Membranes as a Fluorine Free Alternative to Nafion for Low Temperature Water Electrolysis

Driven by environmental and health concerns related to per- and polyfluoroalkyl substances (PFAS), there has been growing interest in developing fluorine-free proton (H + ) exchange membrane (PEM) materials for fuel cells and water electrolyzers. In this study, we present a side-by-side comparison of the key transport properties of submicron thick, PFAS-free amorphous silicon dioxide (SiO 2 ) membranes to Nafion, a fluorinated polymer electrolyte membrane that represents the industry standard for PEM fuel cells and electrolyzers. Here, measurements of proton (H + ) conductivity (σ H + ), hydrogen (H 2 ) permeability (P H 2 ), and electrical resistivity (ρ e – ) were conducted using model thin films comprised of SiO 2 membranes deposited by atomic layer deposition (ALD). Although the H + conductivity of the SiO 2 membranes is 2–3 orders of magnitude lower than Nafion, the addition of phosphorus dopants (PO x ) improves H + conductivity such that the area specific membrane resistance of thin (<50 nm) PO x -doped SiO 2 membranes is more than an order of magnitude lower than Nafion-117. Importantly, the safe operation of such nanoscale membranes within a PEM electrolyzer is feasible thanks to the low H 2 permeability of dense SiO 2 -based membranes, which are predicted to limit H 2 crossover rates to acceptable levels for pressures up to ≈ 100 bar. As a proof-of-principle demonstration, a chip-scale water electrolyzer based on 100 nm thick PO x -SiO 2 membrane is shown to achieve a current density of 2 A cm –2 at a potential of 2.5 V. If this technology can be successfully scaled up, H + conducting oxide membranes offer an attractive PFAS-free alternative to Nafion for efficient and durable water electrolysis and fuel cell technologies.

Nafion↗

Polyamide-Based Ion Exchange Membranes: Cation-Selective Transport through Water Purification Membranes

Ion-selective membranes are necessary components of many electrochemical systems including fuel cells, electrolyzers, redox flow batteries, and electrodialyzers. Perfluorinated sulfonated membranes (PFSMs) dominate these applications due to their excellent combination of fast ion transport, stability, and processability. However, perfluorinated cation exchange membranes (CEMs) are expensive, and their production process involves chemistry that generates toxic perfluorinated chemicals. The development of affordable, nonfluorinated membranes with a competitive combination of high ion selectivity, transport, and stability could help enable the widespread use of the technologies listed above while hastening the development of emerging electrochemical systems, including aqueous alkaline CO 2 sorbent regeneration. To this end, we pursue the use of thin-film composite polyamide (PA-TFCs) membranes–those that typically find application in reverse osmosis and nanofiltration desalination–as cation-selective exchange membranes. Given their negative surface charge under neutral-to-alkaline conditions, PA-TFCs can serve as effective CEMs in these pH regimes. We prepared a series of PA-TFCs from traditional monomers (trimesoyl chloride and piperazine) and compared their thicknesses, charge densities, water transport properties, ion transport properties, and long-term stability in a high pH environment to traditional CEMs (Nafion and FKE) and commercial nanofiltration and reverse osmosis membranes. We find that some of the best-performing PA-TFC membranes have similar resistances and Na + transference numbers compared to Nafion 117 in Na 2 SO 4 and NaHCO 3 -containing solutions. This proof-of-principle study suggests that further optimization of PA-TFCs could enable cost-effective ion exchange membrane alternatives to PFSMs.

36 MATERIALS SCIENCE↗

Coupled Interfacial Kinetics and Transport Resistances Govern High-Current Behavior in Bipolar Membranes

Bipolar membranes (BPMs) enable electrochemical systems that operate across large pH gradients; however, high-current operation is often limited by voltage losses whose origins remain difficult to resolve in membrane−electrode assemblies. Here, we combine electrochemical impedance spectroscopy with distribution of relaxation times (EIS–DRT) analysis and operando synchrotron X-ray diffraction to examine interfacial polarization, membrane hydration, and transport in commercial and synthesized BPMs. EIS–DRT isolates the BPM-associated interfacial contribution and shows that the commercial BPM exhibits larger water-dissociation-associated overpotentials than the synthesized BPM. Operando hydration mapping shows that both membranes retain water at the bipolar junction during high-current operation, while anode-adjacent hydration gradients are more pronounced in the commercial membrane. These results indicate that high-current voltage losses are not governed by junction water starvation alone but by coupled interfacial polarization and transport resistances.

36 MATERIALS SCIENCE↗

Solvent-induced membrane stress in biofuel production: molecular insights from small-angle scattering and all-atom molecular dynamics simulations

The disruptive effect of organic solvents on microbial membranes represents a significant challenge to the economical production of green fuels and value-added chemicals from lignocellulosic feedstocks. One route to overcoming this challenge is to engineer microbes with membranes capable of resisting organic solvent stresses. In this regard, it is useful to understand the mechanisms by which organic solvents disrupt typical biomembranes. In this study, molecular dynamics (MD) simulation, complemented by small-angle X-ray and neutron scattering (SANS/SAXS), provide a molecular-scale view of the disruption of a microbial model membrane by 1-butanol and tetrahydrofuran (THF), two common water–organic cosolvent mixtures of importance in biofuel production. Solvent interactions at the interface between the head-group and fatty acid tail regions lead to more dramatic membrane changes than interactions solely at the head-groups or tails. Although both organic solvents are found to partition into the membrane, the depth of solvent penetration into the membrane is quite different. Specifically, 1-butanol localizes near the interface between the lipid heads and tails at low concentrations, but partitions into both the head and tail regions at high concentrations. In contrast, THF, overall, partitions less than 1-butanol and prefers the lipid tail regions. Importantly, the presence of 1-butanol near the head/tail interface introduces drastic membrane changes not seen with THF. The organic solvent interactions with the lipids lead to membrane thinning and fluidization, but more so for 1-butanol than for THF. These results suggest that an aim for the future engineering of robust membranes could be to design lipid head groups that reduce the accumulation of organic solvents at the head–tail interface and that rational designs need also be cognizant of the different solvent-specific mechanisms responsible for membrane disruption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance

Many solid-state devices, especially those requiring anion conduction, often add a supporting electrolyte to enable efficient operation. The prototypical case is that of anion-exchange-membrane water electrolyzers (AEMWEs), where addition of an alkali metal solution improves performance. However, the specific mechanism of this performance improvement is currently unknown. This work investigates the functionality of the alkali metal solution in AEMWEs using experiments and mathematical models. The results show that additional hydroxide plays a key role not only in ohmic resistance of the membrane and catalyst layer but also in the reaction kinetics. The modeling suggests that the added liquid electrolyte creates an additional electrochemical interface with the electrocatalyst that provides ion-transport pathways and distributes product gas bubbles; the total effective electrochemical active surface area in the cell with 1 M KOH is 5 times higher than that of the cell with DI water. In the cell with 1 M KOH, more than 80% of the reaction current is associate with the liquid electrolyte. These results indicate the importance of high pH of electrolyte and catalyst/electrolyte interface in AEMWEs. The understanding of the functionality of the alkali metal solution presented in this study should help guide the design and optimization of AEMWEs.

25 ENERGY STORAGE↗

Integrated Ion-Exchange Membrane Resin Wafer Assemblies for Aromatic Organic Acid Separations Using Electrodeionization

Aromatic acids, such as p-coumaric acid, are valuable chemical intermediates that are used in the specialty chemical industries because they are precursors to phenylpropanoid compounds. The separation of p-coumaric acid from fermentation broths is a critical step in the biochemical production process and more broadly the circular carbon economy. Electrodeionization (EDI) has been applied toward separations of low-carbon chain acids, but purifying p-coumaric acid has been challenging due to fouling and irreversible binding with ion-exchange membranes and resins. Here, we report a new membrane wafer assembly (MWA) consisting of laminated ion exchange membranes to porous ionomer-binder resin wafers for EDI. The MWAs in an EDI stack showed a 7-fold increase in p-coumaric acid capture while also using 70% less specific energy consumption when benchmarked against state-of-the-art resin wafer EDI modules. The more efficient p-coumaric acid recovery was ascribed to (i) the 38% reduction in interfacial transport resistance between the membrane and resin wafer and (ii) using imidazolium anion exchange membranes and ionomer binders in the MWA. MD simulations revealed enhanced transport rates for p-coumarate in imidazolium ionomers through π–π interactions. As a result, adopting the new MWA significantly reduced the amount of ion-exchange membranes in EDI and may lead to drastic capital cost savings.

42 ENGINEERING↗

Combined electrocoagulation-microfiltration-membrane distillation for treatment of hydraulic fracturing produced water

Hydraulic fracturing flowback and produced water is a highly impaired wastewater containing dissolved salts polar and non-polar organic compounds, oil and surfactants. Here a combined electrocoagulation - microfiltration – membrane distillation process has been used to treat this wastewater. Electrocoagulation followed by microfiltration was used to pretreat the wastewater prior membrane distillation. The initial total dissolved solids (TDS) concentration was extremely high being 245,300 mg L -1 . After electrocoagulation, the total organic carbon (TOC) was reduced from 120 mg L -1 to 64 mg L -1 . Tangential flow microfiltration using a 0.1 μm pore size polyethersulfone membrane was used to separate the particulate matter after electrocoagulation and to further reduce the TOC to 44 mg L -1 . Membrane distillation was used to desalinate the pretreated produced water resulting in a high quality treated water (TDS of 56 mg L -1 and TOC 1 mg L -1 ). Three membranes with very different surface morphology were used: commercially available polyvinylidene fluoride, electrospun poly(vinylidene fluoride-co-hexafluoropropylene) nanofibers and multiwalled carbon nanotube coated polytetrafluoroethylene. The TDS in the retentate increased to over 350,000 mg L -1 . During membrane distillation, the temperature of the feed tank was maintained at 36 °C while the feed entered the module at 60 °C in order to minimize scaling on the membrane. The surface properties of an ideal membrane that is resistant to wetting and provides high flux is likely to depend on the TDS and properties of the wastewater.

42 ENGINEERING↗

Leveraging microfluidic dielectrophoresis to distinguish compositional variations of lipopolysaccharide in E. coli

Lipopolysaccharide (LPS) is the unique feature that composes the outer leaflet of the Gram-negative bacterial cell envelope. Variations in LPS structures affect a number of physiological processes, including outer membrane permeability, antimicrobial resistance, recognition by the host immune system, biofilm formation, and interbacterial competition. Rapid characterization of LPS properties is crucial for studying the relationship between these LPS structural changes and bacterial physiology. However, current assessments of LPS structures require LPS extraction and purification followed by cumbersome proteomic analysis. This paper demonstrates one of the first high-throughput and non-invasive strategies to directly distinguish Escherichia coli with different LPS structures. Using a combination of three-dimensional insulator-based dielectrophoresis (3DiDEP) and cell tracking in a linear electrokinetics assay, we elucidate the effect of structural changes in E. coli LPS oligosaccharides on electrokinetic mobility and polarizability. We show that our platform is sufficiently sensitive to detect LPS structural variations at the molecular level. To correlate electrokinetic properties of LPS with the outer membrane permeability, we further examined effects of LPS structural variations on bacterial susceptibility to colistin, an antibiotic known to disrupt the outer membrane by targeting LPS. Our results suggest that microfluidic electrokinetic platforms employing 3DiDEP can be a useful tool for isolating and selecting bacteria based on their LPS glycoforms. Future iterations of these platforms could be leveraged for rapid profiling of pathogens based on their surface LPS structural identity.

59 BASIC BIOLOGICAL SCIENCES↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Editors’ Choice—Necessity to Avoid Titanium Oxide as Electrocatalyst Support in PEM Fuel Cells: A Membrane Durability Study

Pt/TiO 2 as electrocatalyst was found to significantly increase the rate of the membrane chemical degradation in a polymer electrolyte membrane (PEM) fuel cell. The increased degradation was proved to be due to TiO x (TiO 2 or Ti 4 O 7 ), which is widely recognized as a promising corrosion-resistant electrocatalyst support. The membrane degradation (thinning) appears to be preferentially in the side facing anode electrode. Migrated Ti species as a result of TiO x dissolution during fuel cell operation in an acidic environment was quantified by electron probe microanalysis (EPMA). Total fluorine inventory loss of the membrane strongly depends on the quantity of migrated Ti species (likely Ti 3+ and/or Ti 4+ ). The membrane chemical degradation induced by TiO x is proposed to be due to dissolved ionic Ti species reacting with H 2 O 2 through a Fenton reaction. TiO x is determined to be inviable as electrocatalyst support for PEM fuel cells, and future research is suggested to be directed toward alternative oxides with similar corrosion-resistance.

08 HYDROGEN↗

Fouling behavior of zwitterionic membranes compared to polyamide membranes

Membrane fouling remains a critical bottleneck for reverse osmosis (RO) desalination, driving energy consumption and reducing membrane lifetime. Here, we employ all-atom molecular dynamics simulations to investigate the antifouling behavior of random zwitterionic amphiphilic copolymer (r-ZAC) membranes composed of sulfobetaine methacrylate (SBMA) and allyl methacrylate (AMA), benchmarked against conventional polyamide (PA) RO membranes. Structural and dynamical analyses—including radial distribution functions, coordination numbers, tetrahedral order parameters, vector orientation, and residence-time correlation functions—reveal that r-ZAC surfaces sustain tightly bound, long-lived hydration layers with preserved tetrahedrality and anisotropic water orientation, in sharp contrast to the weak and disordered hydration of PA. Steered molecular dynamics simulations demonstrate that r-ZAC membranes impose substantial free-energy barriers to foulant approach (alginate ≈ 90 kcal/mol, sucrose ≈ 35 kcal/mol, humic acid ≈ 15 kcal/mol), whereas PA membranes exhibit negligible barriers (< 1 kcal/mol) and thermodynamically favorable adsorption. Detailed foulant–surface interaction analyses show that zwitterionic hydration and electrostatic heterogeneity in r-ZAC suppress adhesion, except in the case of amphiphilic humic acid, which exploits multiple binding modes. Together, these results establish molecular-level design principles for antifouling membranes: the combination of zwitterionic hydration, structured interfacial water, and controlled amphiphilic balance in r-ZAC membranes provides superior resistance to organic fouling relative to PA.

Cross-linked polyamide↗

Emulsion separation and fouling of electrospun polyacrylonitrile membranes for produced water applications

Produced water (PW) is a complex mixture generated during oil and gas extraction. Membrane fouling by hydrocarbon emulsions (sizes < 10 µm) challenges most PW treatment systems. Electrospinning has the possibility of creating microporous membranes that present unique performance properties, though evaluations of these characteristics are largely restricted to unrealistic dead-end configurations. Three different nanofibrous polyacrylonitrile (PAN) membranes were synthesized by electrospinning and their performances contrasted with a commercially available PAN membrane. Feed solutions included synthetic oil and solvent emulsions and a PW from an operating well-site. Two nanoparticles, polyaniline (PANI) and reduced graphene oxide (RGO), were studied for enhancing the oleophobicity and fouling properties of the electrospun PAN membranes. Electrospun membranes showed higher porosities (68 to 80 %) and water permeance values (9,000 to 10,000 LMH/bar) relative to that for the commercially available PAN membrane (44 % and 8,800 LMH/bar). All electrospun membranes provided superior performance characteristics when treating the emulsions and PW relative to the commercial membrane. Furthermore, the PANI integrated membrane demonstrated the greatest resistance to oil/solvent emulsion fouling and comparable performance to the RGO and PAN membrane treating the PW.

03 NATURAL GAS↗

Monitoring the corrosion resistance of cold-spray coatings with membrane-based sensors

In this presentation, the MBES shows the ability to detect the change in exposed environment even with cold-spray coatings. Corrosion rates from the cold-spray coating were comparable to a 316 stainless steel sample. Defects in the coating did not impact sensor performance in terms of corrosion rate or water content detection. Energy dispersive X-ray spectroscopy was used to document ion migration into the membrane.

Rendon, Arnaldo↗

Corrosion resistance of functionally graded TiN/Ti coatings for proton exchange membrane fuel cells

Bipolar Plates (BPP) are important components of proton exchange membrane fuel cell (PEMFC) stacks. In the development of innovative fuel cell designs, it is advantageous to use aluminum for these applications, however, this material lacks the necessary corrosion resistance. Since the performance of PEMFC stacks depends on BPP properties, in particular, corrosion resistance, depositing titanium nitride (TiN) thin films onto aluminum substrates may improve their efficiency and durability. Present work focuses on improving corrosion resistance and hydrophobicity of TiN/Ti by using N graded films deposited onto aluminum substrates (AA-1100) by grid-assisted magnetron sputtering (GAMS). Electrochemical impedance spectroscopy (EIS) with potentiodynamic and potentiostatic polarization are used to investigate the performance of the substrate/film system at room temperature and 70 oC, thus simulating a prototypic PEMFC electrolyte environment. Electrochemical test results showed that graded TiN films improved corrosion resistance when compared with both the homogeneous films and the AA1100 uncoated substrate. Furthermore, contact angle results reveal improved hydrophobicity for both homogeneous and graded TiN coatings when compared with the AA1100 substrate.

25 ENERGY STORAGE↗