Search NASA⌕ Search

SEARCH · Search NASA

Results for “Metal insulator transition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Metallic Vs Inflatable Primary Structure: A Comprehensive Trade for a Mars Transit Habitat

Large diameter inflatable habitat solutions are hypothesized to have an advantage over traditional metallic habitats of equal volume and functional requirements in terms of minimizing mass. A fair and comprehensive trade of metallic primary structure versus inflatable softgoods primary structure for a Mars Transit Habitat was conducted by The Boeing Company under the NASA Next Space Technologies for Exploration Partnerships-2 (NextSTEP-2)Appendix A contract in order to determine the minimum mass option from a system level. A Mars Transit Habitat is a major system mass driver because small increases in the mass can create large mass changes in the propulsive stage, adding complexity and cost to the mission. Three different vehicle configurations were traded using a fixed volume constraint and the same Ground Rules and Assumptions(GR&A)provided by NASA. The configurations were 1) 5.5 m diameter metallic habitat, 2) 7.0 m diameter metallic habitat, and 3) 7.63 m diameter inflatable habitat. In order to complete the trade, each configuration was analyzed and sized, but a system level approach had to be taken to ensure other aspects and subsystems besides the structure were captured. The primary functions (i.e. restraint layer, bladder, multilayer insulation [MLI], micro-meteoroid orbital debris [MMOD]) and strength advantages of softgoods are well understood, but there were other system level impacts that were discovered or addressed that are unique to softgoods. For the metallic structure, a modern and mass optimal material and manufacturing process was adopted to ensure the lightest weight options were evaluated. Two different aluminium lithium structures were evaluated, a longer length 5.5 m diameter and a shorter length 7 m diameter structure. The trade demonstrates that each configuration is feasible and close to the target dry mass for the Mars Transit Habitat Trans-Martian Injection burn. System level mass was the primary consideration, but since the three concepts were close in total mass, a clear winner did not arise. Secondary factors were evaluated such as architecture habitability (human factors), development considerations, on-orbit activation and outfitting, extensibility to other applications, and configuration flexibility. The aggregation of the lowest mass, most benefits, and fewest challenges resulted in the 5.5m diameter metallic configuration being the most favorable.

Matthew Ziglar↗

Critical Issues for Cu(InGa)Se2 Solar Cells on Flexible Polymer Web

Elemental in-line evaporation on glass substrates has been a viable process for the large-area manufacture of CuInSe2-based photovoltaics, with module efficiencies as high as 12.7% [1]. However, lightweight, flexible CuInSe2-based modules are attractive in a number of applications, such as space power sources. In addition, flexible substrates have an inherent advantage in manufacturability in that they can be deposited in a roll-to-roll configuration allowing continuous, high yield, and ultimately lower cost production. As a result, high-temperature polymers have been used as substrates in depositing CuInSe2 films [2]. Recently, efficiency of 14.1% has been reported for a Cu(InGa)Se2-based solar cell on a polyimide substrate [3]. Both metal foil and polymer webs have been used as substrates for Cu(InGa)Se2-based photovoltaics in a roll-to-roll configuration with reasonable success [4,5]. Both of these substrates do not allow, readily, the incorporation of Na into the Cu(InGa)Se2 film which is necessary for high efficiency devices [3]. In addition, polymer substrates, can not be used at temperatures that are optimum for Cu(InGa)Se2 deposition. However, unlike metal foils, they are electrically insulating, simplifying monolithically-integrated module fabrication and are not a source of impurities diffusing into the growing film. The Institute of Energy Conversion (IEC) has modified its in-line evaporation system [6] from deposition onto glass substrates to roll-to-roll deposition onto polyimide (PI) film in order to investigate key issues in the deposition of large-area Cu(InGa)Se2 films on flexible polymer substrates. This transition presented unexpected challenges that had to be resolved. In this paper, two major problems, spitting from the Cu source and the cracking of Mo back contact film, will be discussed and the solution to each will be presented.

Eser, Erten↗

Thermal Field Imaging Using Ultrasound

It is often desirable to be able to determine the temperature field in the interiors of opaque fluids forced into convection by externally imposed temperature gradients. To measure the temperature at a point in an opaque fluid in the usual fashion requires insertion of a probe, and to determine the full field therefore requires either the ability to move this probe or the introduction of multiple probes. Neither of these solutions is particularly satisfactory, although they can lead to quite accurate measurements. As an alternative we have investigated the use of ultrasound as a relatively non-intrusive probe of the temperature field in convecting opaque fluids. The temperature dependence of the sound velocity can be sufficiently great to permit a determination of the temperature from timing the traversal of an ultrasound pulse across a chamber. In this paper we will present our results on convecting flows of transparent and opaque fluids. Our experimental cells consist of relatively narrow rectangular cavities made of thermally insulating materials on the sides, and metal top and bottom plates. The ultrasound transducer is powered by a pulser/receiver, the signal output of which goes to a very high speed signal averager. The average of several hundred to several thousand signals is then sent to a computer for storage and analysis. The experimental procedure is to establish a convective flow by imposing a vertical temperature gradient on the chamber, and then to measure, at several regularly spaced locations, the transit time for an ultrasound pulse to traverse the chamber horizontally (parallel to the convecting rolls) and return to the transducer. The transit time is related to the temperature of the fluid through which the sound pulse travels. Knowing the relationship between transit time and temperature (determined in a separate experiment), we can extract the average temperature across the chamber at that location. By changing the location of the transducer it is then possible to find the average temperature at different locations along the chamber, thereby determining the temperature profile along the system. (In the future we will construct an array of transducers. This will give us the capability to determine the temperature profile much more rapidly than at present, an important consideration if time-dependent phenomena are to be studied.) To validate our procedure we introduced encapsulated liquid crystal particles into glycerol. The liquid crystal particles' color varies depending on the temperature of the fluid. A photograph of the fluid through transparent sidewalls therefore gives a picture of the temperature field of the convecting fluid, independent of our ultrasound imaging. A representative result is shown in the Figure 1, which reveals a very satisfying correspondence between the two techniques. Therefore we have a great deal of confidence that the ultrasound imaging approach is indeed measuring the actual temperature profile of the fluid. The technique has also been applied to convecting liquid metal flows, and representative data will be presented from those experiments as well.

Andereck, D.↗

Fabrication of Compact Superconducting Lowpass Filters for Ultrasensitive Detectors

It is extremely important for current and future far-infrared and sub-millimeter ultrasensitive detectors, which include transition edge sensors (TES) and microwave kinetic inductance detectors, to be adequately filtered from stray electromagnetic radiation in order to achieve their optimal performance. One means of filtering stray radiation is to block leakage associated with electrical connections in the detector environment. Here we discuss a fabrication methodology for realizing non-dissipative planar filters imbedded in the wall of the detector enclosure to limit wave propagation modes up to far-infrared frequencies. Our methodology consists of fabricating a boxed stripline transmission line, in which a superconducting (Nb, Mo, or Al) transmission line is encased in a silicon dioxide dielectric insulator coated with a metallic shell. We report on achieved attenuation and return loss and find that it replicates the simulated data to a high degree.

Brown, Ari↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Variable Conductance Heat Pipe Cooling of Stirling Convertor and General Purpose Heat Source

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Radioisotope Power System↗

Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Convertor↗

Variable Conductance Heat Pipe Cooling of Stirling Convertor and General Purpose Heat Source

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Tarau, Calin↗

Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 C temperature increase from the nominal vapor temperature. The 19 C temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Schwendeman, Carl↗

Mechanical Testing of PMCs under Simulated Rapid Heat-Up Propulsion Environments: In-Plane Compressive Behavior - II

Carbon fiber thermoset polymer matrix composites (PMC) with high temperature polyimide based in-situ polymerized monomer reactant (PMR) resin has been used for some time in applications which can see temperatures up to 550 F. Currently, graphite fiber PMR based composites are used in several aircraft engine components including the outer bypass duct for the GE F-404, exit flaps for the P&W F-100-229, and the core cowl for the GE/Snecma CF6-80A3. Newer formulations, including PMR-II-50 are being investigated as potential weight reduction replacements of various metallic components in next generation high performance propulsion rocket engines that can see temperatures which exceed 550 F. Extensive FEM thermal modeling indicates that these components are exposed to rapid heat-up rates (up to -200 F/sec) and to a maximum temperature of around 600 F. Even though the predicted maximum part temperatures were within the capability of PW-II-50, the rapid heat-up causes significant through-thickness thermal gradients in the composite part and even more unstable states when combined with moisture. Designing composite parts for such extreme service environments will require accurate measurement of intrinsic and transient mechanical properties and the hygrothermal performance of these materials under more realistic use conditions. The mechanical properties of polymers degrade when exposed to elevated temperatures even in the absence of gaseous oxygen. Accurate mechanical characterization of the material is necessary in order to reduce system weight while providing sufficient factors of safety. Historically, the testing of PMCs at elevated temperatures has been plagued by the antagonism between two factors. First, moisture has been shown to profoundly affect the mechanical response of these materials at temperatures above their glass transition temperature while concurrently lowering the material's Tg. Moisture phenomena is due to one or a combination of three effects, i.e., plastization of polymeric material by water, the internal pressure generated by the volatilization of water at elevated temperatures, and hydrolytic chemical decomposition. However, moisture is lost from the material at increasing rates as temperature increases. Second, because PMCs are good thermal insulators, when they are externally heated at even mild rates large thermal gradients can develop within the material. At temperatures where a material property changes rapidly with temperature the presence of a large thermal gradient is unacceptable for intrinsic property characterization purposes. Therefore, long hold times are required to establish isothermal conditions. However, in the service environments high-heating-rates, high temperatures, high-loading rates are simultaneous present along with residual moisture. In order to capture the effects of moisture on the material, holding at- temperature until isothermal conditions are reached is unacceptable particularly in materials with small physical dimensions. Thus, the effects due to moisture on the composite's mechanical characteristics, ie., their so-called analog response, may be instructive. One approach employed in this program was rapid heat-up (approx. 200 F/sec.) and loading of both dry and wet in-plane compressive specimens to examine the effects of moisture on this resin dominated mechanical property of the material.

Stokes, Eric H.↗

Electron Beam Induced Luminescence of SiO2 Optical Coatings

Optical coatings of disordered thin film SiO,/SiO, samples undergoing electron beam bombardment exhibited a cathodoluminescence effect. Measurements were made of the absolute illuminance and emission spectra as functions of incident electron energy (0.2 keV to 30 keV). flux (approx. 0.1 nA/sq cm to > 100 nA/sq cm) and power (<50 nW/sq cm to > 3mW/sq cm) for coatings (approx.60 nm to approx.200 nm thick) on reflective metal substrates over a range of sample temperatures (approx.40 K to approx.400 K) and emission wavelengths (approx.260 nm to approx.5000 nm). Illuminance reached a plateau saturation intensity I(sub sat) approx. 10(exp -4)W/sq cm. scaling as [I(sub mc)/(I + I(sub mc)/I(sub sat)] as incident power I(sub mc) approached I(sub sat). Well below I(sub sat), illuminance scaled linearly with incident power for lower-energy non-penetrating radiation that deposited all of its energy in the dielectric film. At higher incident energies (> 1-5 keV) electrons penetrate the dielectric, depositing only a fraction of their energy in the dielectric film, where deposited energy scales as the ratio of film thickness to penetration range. Since electron range exhibits a peak below approx. 1 keV, the illuminance decreased with increasing energy for penetrating radiation. The temperature dependence of the illuminance. in general, increased with decreasing temperature. Changes in apparent color with temperature were also observed. Four bands in the UV/VIS/NIR range from 300 nm to 1000 nm were observed in spectral measurements; no significant luminescence was detected in a range from approx. 1000 nm to approx. 5000 nm. These different bands either increased or decreased in intensity and shifted slightly in energy with decreasing temperature. Our measurements are explained in terms of simple disordered band theory models based on atomic-scale stochastic transport of electrons in highly disordered insulating materials. The theoretical models provide a fundamental basis for understanding the dependence of cathodoluminescence on irradiation time, incident flux and energy. and sample thickness and temperature. The observed luminescence occurs when an incident high energy electron excites a valence band electron into the conduction band. Following the excitation. a complex series of transitions take place between the extended conduction states and the long-lived localized trapped states (or chromophores) associated with structural or compositional defects in the dielectric materials. Thc transport equations and models of thc spatial and energy distribution of the trapped states below the mobility edge, their occupancy, and transitions provide microscopic scale insights into this macroscopic phenomenon. Our observations and theoretical models are also compared with similar previous room temperature studies of similar SiO2 films.

Dennison, J. R.↗

Remediation Technologies Eliminate Contaminants

All research and development has a story behind it, says Jacqueline Quinn, environmental engineer at Kennedy Space Center. For Quinn, one such story begins with the Saturn 1B launch stand at Kennedy and ends with a unique solution to a challenging environmental problem. Used in a number of Apollo missions and during the Skylab program, the Saturn 1B launch stand was dismantled following the transition to the Space Shuttle Program and stored in an open field at Kennedy. Decades later, the Center s Environmental Program Office discovered evidence of chemicals called polychlorinated biphenyls (PCBs) in the field s soil. The findings were puzzling since PCBs a toxin classified as a probable carcinogen by the Environmental Protection Agency (EPA) have been banned in the United States since 1979. Before the ban, PCBs were commonly used in transformer oils that leached into the ground when the oils were changed out and dumped near transformer sites, but there were no electrical transformers near the dismantled stand. It soon became apparent that the source of the PCBs was the launch stand itself. Prior to the ban, PCBs were used extensively in paints to add elasticity and other desirable characteristics. The PCB-laden paint on the Saturn 1B launch stand was flaking off into the field s soil. Nobody knew there were PCBs in the paint, says Quinn, noting that the ingredient was not monitored carefully when it was in use in 1960s. In fact, she says, the U.S. EPA was not even established until 1970, a year after Neil Armstrong first set foot on the Moon. Nobody knew any better at the time, Quinn says, but today, we have the responsibility to return any natural environmental media to as close to pristine a condition as possible. Quinn, fellow engineer Kathleen Loftin, and other Kennedy colleagues already had experience developing unprecedented solutions for environmental contamination; the team invented the emulsified zero-valent iron (EZVI) technology to safely treat groundwater tainted by chlorinated solvents once used to clean rocket engine components. The award-winning innovation (Spinoff 2010) is now NASA s most licensed technology to date. PCBs in paint presented a new challenge. Removing the launch stand for recycling proved a difficult operation; the toxic paint had to be fully stripped from the steel structure, a lengthy and costly process that required the stripped paint to be treated before disposal. Noting the lack of efficient, environmentally friendly options for dealing with PCBs, Quinn and her colleagues developed the Activated Metal Treatment System (AMTS). AMTS is a paste consisting of a solvent solution containing microscale particles of activated zero-valent metal. When applied to a painted surface, the paste extracts and degrades the PCBs into benign byproducts while leaving the paint on the structure. This provides a superior alternative to other methods for PCB remediation, such as stripping the paint or incinerating the structure, which prevents reuse and can release volatized PCBs into the air. Since its development, AMTS has proven to be a valuable solution for removing PCBs from paint, caulking, and various insulation and filler materials in older buildings, naval ships, and former munitions facilities where the presence of PCBs interferes with methods for removing trace explosive materials. Miles of potentially toxic caulking join sections of runways at airports. Any of these materials installed before 1979 potentially contain PCBs, Quinn says. "This is not just a NASA problem," she says. "It s a global problem."

Source record↗