Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Microchannel reactive distillation for the conversion of aqueous ethanol to ethylene

Here we demonstrate the proof-of-concept for microchannel reactive distillation for alcohol-to-jet application: combining ethanol/water separation and ethanol dehydration in one unit operation. Ethanol is first distilled into the vapor phase, converted to ethylene and water, and then the water co-product is condensed to shift the reaction equilibrium. Process intensification is achieved through rapid mass transfer—ethanol stripping from thin wicks using novel microchannel architectures—leading to lower residence time and improved separation efficiency. Energy savings are realized with integration of unit operations. For example, heat of condensing water can offset vaporizing ethanol. Furthermore, the dehydration reaction equilibrium shifts towards completion by immediate removal of the water byproduct upon formation while maintaining aqueous feedstock in the condensed phase. For aqueous ethanol feedstock (40% w ), 71% ethanol conversion with 91% selectivity to ethylene was demonstrated at 220 °C, 600 psig, and 0.28 h -1 wt hour space velocity. 2.7 stages of separation were also demonstrated, under these conditions, using a device length of 8.3 cm. This provides a height equivalent of a theoretical plate (HETP), a measure of separation efficiency, of ~3.3 cm. By comparison, conventional distillation packing provides an HETP of ~30 cm. Thus, 9.1× reduction in HETP was demonstrated over conventional technology, providing a means for significant energy savings and an example of process intensification. Finally, preliminary process economic analysis indicates that by using microchannel reactive distillation technology, the operating and capital costs for the ethanol separation and dehydration portion of an envisioned alcohol-to-jet process could be reduced by at least 35% and 55%, respectively, relative to the incumbent technology, provided future improvements to microchannel reactive distillation design and operability are made.

10 SYNTHETIC FUELS↗

Validation of Manufacturing Process Designs for Stamped Microchannel Recuperators

Microchannel recuperators can achieve high-efficiency power cycles and chemical reactions by recovering waste heat from hot turbine exhaust and chemical reaction streams. However, the industrial application of microchannel recuperators are restricted by the high cost of patterning and bonding. The objective of this study was thus to investigate new methods for producing microchannel recuperators for emerging markets. Based on greenfield cost estimates, process designs based on stamping, laser welding and vacuum brazing of 316L stainless steel laminae were found to be more economical than conventional photochemical machining and diffusion bonding. Subsequently, validation experiments were conducted to produce stamped microchannel components using cost model parameters. At a mass flow rate of 0.99 g/s, the test article made with laser welding was found to provide higher effectiveness than the test article produced using vacuum brazing. Preliminary investigations showed that residual stresses during laser welding of the laminae led to significant warpage, collapsing channels and making lamina-to-lamina fit up challenging. In contrast, the test article produced by vacuum brazing of stamped laminae showed no clogging and 4.6% and 10.5% channel height standard deviation for the cold and hot channels, respectively. Channel variation in the vacuum brazing sample was determined to be caused by misregistration of laminae during brazing. In future work, efforts are needed to choose cheaper, more ductile brazing foils as well as design a brazing fixture to improve lamina-to-lamina registration.

42 ENGINEERING↗

Atmospheric pressure plasmas interacting with wet and dry microchannels: reverse surface ionization waves

Atmospheric pressure plasma jets (APPJs) are increasingly being used to functionalize polymers and dielectric materials for biomedical and biotechnology applications. Once such application is microfluidic labs-on-a-chip consisting of dielectric slabs with microchannel grooves hundreds of microns in width and depth. The periodic channels, an example of a complex surface, present challenges in terms of directly and uniformly exposing the surface to the plasma. In this paper, we discuss results from computational and experimental investigations of negative APPJs sustained in Ar/N 2 mixtures flowing into ambient air and incident onto a series of microchannels. Results from two-dimensional plasma hydrodynamics modeling are compared to experimental measurements of electric field and fast-camera imaging. The propagation of the plasma across dry microchannels largely consists of a sequence of surface ionization waves (SIWs) on the top ridges of the channels and bulk ionization waves (IWs) crossing over the channels. The IWs are directed into electric field enhanced vertices of the next ridge. The charging of these ridges produce reverse IWs responsible for the majority of the ionization. The propagation of the plasma across water filled microchannels evolve into hopping SIWs between the leading edges of the water channels, regions of electric enhancement due to polarization of the water. Positive, reverse IWs follow the pre-ionized path of the initial negative waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

An Analytical-Numerical Model for Two-Phase Slug Flow through a Sudden Area Change in Microchannels

In this article, two new analytical models have been developed to calculate two-phase slug flow pressure drop in microchannels through a sudden contraction. Even though many studies have been reported on two-phase flow in microchannels, considerable discrepancies still exist, mainly due to the difficulties in experimental setup and measurements. Numerical simulations were performed to support the new analytical models and to explore in more detail the physics of the flow in microchannels with a sudden contraction. Both analytical and numerical results were compared to the available experimental data and other empirical correlations. Results show that models, which were developed based on the slug and semi-slug assumptions, agree well with experiments in microchannels. Moreover, in contrast to the previous empirical correlations which were tuned for a specific geometry, the new analytical models are capable of taking geometrical parameters as well as flow conditions into account.

42 ENGINEERING↗

Monte Carlo simulations of microchannel plate detectors I: steady-state voltage bias results

X-ray detectors based on straight-channel microchannel plates (MCPs) are a powerful diagnostic tool for two-dimensional, time-resolved imaging and timeresolved x-ray spectroscopy in the fields of laser-driven inertial confinement fusion and fast z-pinch experiments. Understanding the behavior of microchannel plates as used in such detectors is critical to understanding the data obtained. The subject of this paper is a Monte Carlo computer code we have developed to simulate the electron cascade in a microchannel plate under a static applied voltage. Also included in the simulation is elastic reflection of low-energy electrons from the channel wall, which is important at lower voltages. When model results were compared to measured microchannel plate sensitivities, good agreement was found. Spatial resolution simulations of MCP-based detectors were also presented and found to agree with experimental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport Measurements of Surface Electrons in 200-nm-Deep Helium-Filled Microchannels Above Amorphous Metallic Electrodes

We report transport measurements of electrons on helium in a microchannel device where the channels are 200 nm deep and 3μm wide. The channels are fabricated above amorphous metallic Ta 40 W 40 Si 20 , which has surface roughness below 1 nm and minimal variations in work function across the surface due to the absence of polycrystalline grains. We are able to set the electron density in the channels using a ground plane. We estimate a mobility of 300cm 2 /Vs and electron densities as high as 2.56×10 9 cm -2 . We demonstrate control of the transport using a barrier which enables pinch-off at a central microchannel connecting two reservoirs. The conductance through the central microchannel is measured to be 10 nS for an electron density of 1.58×10 9 cm -2 . Lastly, our work extends transport measurements of surface electrons to thin helium films in microchannel devices above metallic substrates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Microchannel Reactor for Ethanol to Butene: CRADA 503 [Abstract only]

A key challenge facing most bioprocessing operations is that multiple unit operations are required, thereby resulting in complex, energy-intensive, and expensive processes. Further, biomass transportation costs drive the need for smaller, distributed processing plants. To incorporate the smaller scales desirable for biomass, novel processes must be developed with reduced capital costs. With over 20 years of experience in the development and commercialization of microchannel reactor technology, Oregon State University will partner with Pacific Northwest National Laboratory to demonstrate a microchannel reactor with lower capital costs for an alcohol-to-jet (ATJ) process technology that is currently being commercialized by LanzaTech. Ethanol can be produced from biomass feedstocks such as LanzaTech’s proprietary biochemical process using carbon from a number of possible feedstocks; syngas generated from biomass resources (e.g., MSW, organic industrial waste, agriculture waste) or reformed biogas, or from other biomass feedstocks such as corn kernel fiber. Ethanol then undergoes catalytic dehydration to form ethylene followed by a two-step oligomerization, hydrogenation, and fractionation to control the hydrocarbon product slate to the jet-range. Successful process development aided by a market pull for low carbon aviation fuel has spurred scale-up and commercial demonstration. However, Sustainable Aviation Fuel is a very price sensitive market and improved economics through process intensification will make the current ATJ process even more attractive. Recent efforts at PNNL have culminated in the development of a new catalyst technology for the conversion of ethanol to n-butene-rich olefins. A greater than 90% conversion, total olefin selectivity of 80-90% (n-butene selectivity ~60%), and good stability over a 100 hour test duration has been demonstrated at the bench scale. Producing butene-rich olefins directly from ethanol with high yield is new and impactful because the higher olefins can be selectively oligomerized to distillate-range hydrocarbons, thus eliminating one process step from the current ATJ process. Further, coupling the severely endothermic ethanol dehydration with exothermic C-C bond formation results in more energy efficient processing. Additional intensification and energy savings will stem from incorporating this new ethanol to n-butene catalyst technology within the ATJ process implemented using a microchannel reactor platform. Due to recent advances in microchannel manufacturing methods and associated cost reductions we believe the time is right to adapt this technology toward new commercial bioconversion applications.

02 PETROLEUM↗

Methods for forming small-volume electrical contacts and material manipulations with fluidic microchannels

A microfabricated device employing a bridging membrane and methods for electrokinetic transport of a liquid phase biological or chemical material using the same are described. The bridging membrane is deployed in or adjacent to a microchannel and permits either ionic current flow or the transport of gas species, while inhibiting the bulk flow of material. The use of bridging membranes in accordance with this invention is applicable to a variety of processes, including electrokinetically induced pressure flow in a region of a microchannel that is not influenced by an electric field, sample concentration enhancement and injection, as well as improving the analysis of materials where it is desired to eliminate electrophoretic bias. Other applications of the bridging membranes according to this invention include the separation of species from a sample material, valving of fluids in a microchannel network, mixing of different materials in a microchannel, and the pumping of fluids.

42 ENGINEERING↗

Methods for forming small-volume electrical contacts and material manipulations with fluid microchannels

A microfabricated device employing a bridging membrane and methods for electrokinetic transport of a liquid phase biological or chemical material using the same are described. The bridging membrane is deployed in or adjacent to a microchannel and permits either ionic current flow or the transport of gas species, while inhibiting the bulk flow of material. The use of bridging membranes in accordance with this invention is applicable to a variety of processes, including electrokinetically induced pressure flow in a region of a microchannel that is not influenced by an electric field, sample concentration enhancement and injection, as well as improving the analysis of materials where it is desired to eliminate electrophoretic bias. Other applications of the bridging membranes according to this invention include the separation of species from a sample material, valving of fluids in a microchannel network, mixing of different materials in a microchannel, and the pumping of fluids.

47 OTHER INSTRUMENTATION↗

Separation process using microchannel technology

The disclosed invention relates to a process and apparatus for separating a first fluid from a fluid mixture comprising the first fluid. The process comprises: (A) flowing the fluid mixture into a microchannel separator in contact with a sorption medium, the fluid mixture being maintained in the microchannel separator until at least part of the first fluid is sorbed by the sorption medium, removing non-sorbed parts of the fluid mixture from the microchannel separator; and (B) desorbing first fluid from the sorption medium and removing desorbed first fluid from the microchannel separator. The process and apparatus are suitable for separating nitrogen or methane from a fluid mixture comprising nitrogen and methane. The process and apparatus may be used for rejecting nitrogen in the upgrading of sub-quality methane.

47 OTHER INSTRUMENTATION↗

Laminar drag reduction in microchannels with liquid infused textured surfaces

Liquid infused surfaces (LIS) achieve non-wetting properties through asperity structures containing pockets of a lubricating liquid rather than air. Although studies have demonstrated several potential applications of LIS, the effect of liquid infused texture on the flow of liquid in microchannels has not been systematically addressed. The present work focuses on the effect of liquid-infused texture geometry and the infused liquid properties on the flow characteristics of a bulk fluid in rectangular and round microchannel geometries. Considering four different textured geometries of transverse ridges, longitudinal ridges, in-lined square posts and staggered squares, a detailed parametric study is presented to assess the resulting drag reduction and friction factor, expressed in terms of the Poiseuille number, on the flow in microchannels. The effect of geometrical parameters is investigated for different asperity solid fraction (Φ s ), asperity height (h s ) and channel thickness (H) or tube diameter (D), while the effect of the infused fluid is studied in terms of a ratio of its viscosity relative to the viscosity of the flowing bulk fluid. Based on the results of the parametric study an extension of the conventional Moody diagram for non-wetting surfaces is developed. Finally, a design of experiments study is conducted to relate the drag reduction and Poiseuille number to the various governing parameters, using which conditions that maximize drag reduction are identified.

42 ENGINEERING↗

Energy performance augmentation of domestic refrigerators with microchannel condensers

Refrigerators are one of the most extensively used household appliances, accounting for approximately 4% of total household electricity consumption. Enhancing their energy performance can significantly reduce residential energy demand. As a result, this study focuses on reducing the energy consumption of a French-door, bottom-mount refrigerator using isobutane (R600a) as the working fluid. Here, the performance improvement of the refrigerators has been obtained mainly through improving the vapor compression refrigeration cycle, with a particular emphasis on condenser design. This study explores the impact of three-pass serpentine microchannel condenser on energy performance, along with the effects of two distinct fan combinations. Charge optimization experiments were conducted to identify the optimal refrigerant mass for the refrigerator unit with microchannel condenser. Additionally, a comprehensive numerical model was developed to analyze the behavior of vapor compression cycle under various refrigerant charges. The experimental findings revealed that the refrigerator unit with the three-pass microchannel condenser reduces the energy consumption of isobutane-based domestic refrigerators up to 16% while reducing the refrigerant charge by 11% in comparison to the refrigerator unit with conventional wire-and-tube condenser.

Charge optimization↗

Computational examination of two-phase microchannel heat transfer correlations with conjugate heat spreading

Microchannel flow boiling is an attractive thermal management strategy for ever-growing volumetric heat dissipation demands associated with electronic systems. Due to difficulties related to measurement at the microscales, the majority of researchers have chosen to study relatively simple situations with uniform heat flux. However, many applications involve local hotspots which give rise to highly non-uniform heat flux and temperature gradients due to heat spreading. This necessitates the consideration of conjugate heat transfer for accurate analysis. The current work is aimed at investigating conjugate heat transfer in a two-phase microchannel array. Experimental data was collected on R134a flow boiling heat transfer for very small hydraulic diameter (<100 µm) silicon microchannels with very high heat fluxes (>1 kW cm -2 ) applied via platinum strip heaters with a footprint size of 1 cm × 1 mm. The collected experimental data was then combined with detailed computational modeling utilizing finite element modeling with COMSOL Multiphysics and MATLAB to examine the applicability of five published heat transfer correlations for use in determining local heat transfer coefficients. A two-phase correlation from Agostini and Bontemps, developed for markedly different test parameters, provided the best computational agreement with an RMS temperature difference from experiment of 3.3 °C and a predicted peak perimeter-averaged heat transfer coefficient of 116 MW m -2 K -1 . Modeling confirms the presence of highly non-uniform local heat flux and correspondingly non-uniform local heat transfer coefficient. Finally, the results of this study make clear the need for better micro-scale two-phase correlations developed to predict local heat transfer coefficients at these small scales and high local heat fluxes.

42 ENGINEERING↗

Electronic measurement of microchannel plate pulse height distributions

Microchannel plates are a central component of the x-ray framing cameras used as analog imagers in many plasma experiment diagnostic systems. The microchannel plate serves as an amplifying element, increasing the electronic signal from incident radiation by factors of 10{sup 3}-10{sup 5}, with a broad pulse-height distribution. Seeking to optimize the photon-to-electron conversion efficiency and noise distribution of x-ray cameras, we will characterize the pulse-height distribution of the electron output from a single microchannel plate. Replacing the framing camera's phosphor-coated fiber optic screen with a charge-collection plate and coupling to a low-noise multichannel analyzer, we quantified the distribution in the total charge generated per photon event. The electronically measured pulse height distribution is used to estimate the signal-to-noise ratio of radiographic images from framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗