Psychology of computer use: IX. A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests which may have application in screening for fitness-for-duty or for persons who may be exposed to environmental stress, toxic agents, or disease. 16 subjects self-administered 18 microcomputer-based tests (13 new, 5 "core"), without proctors, over 10 sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the tests from the "core" battery were comparable to those obtained previously under more controlled experimental conditions. Eight of the new tests exceeded minimum criteria for metric and practical requirements and can be recommended as additions to the menu. Although the average retest reliability was high, cross-correlations between tests were low, implying factorial diversity. The menu can be used to form batteries with flexible total testing time which are likely to tap different mental processes and functions.

NASA Discipline Neuroscience↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

A proposed microcomputer implementation of an Omega navigation processor

A microprocessor navigation systems using the Omega process is discussed. Several methods for correcting incoming sky waves are presented along with the hardware design which depends on a microcomputer. The control program is discussed, and block diagrams of the Omega processor and interface systems are presented.

Abel, J. D.↗

A microcomputer-based low-cost Omega navigation system

The application of a low cost, commercially available microcomputer as the navigation processor for a simplified OMEGA navigation system is an area of current research. The interface of a low cost front end OMEGA sensor is described and an example of the phase processing software and navigation routines is given. Emphasis is placed on the description of results obtained with the software version of the OMEGA burst filter known as the memory aided phase locked loop.

Lilley, R. W.↗

Demonstration program for Omega receiver prototype microcomputer data processing

The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.

Lilley, R. W.↗

A microcomputer-based low-cost Omega sensor processor

The engineering approach used in the design of a low cost Omega sensor processor is discussed. The processor and its operations are described, as well as the system hardware and software. Circuit details of the hardware modules and program listings for the FORTRAN and microcomputer software are included.

Salter, R. J., Jr.↗

A programmable microcomputer for real time speech processing

The implementation of a programmable microprocessor for real time speech processing is described. The design of a fast special-purpose computer operating at 150 nsec per instruction time reduces the problem of speech encoding and decoding to a software problem. Each instruction is a twelve-bit word, and the information conveyed by a word is explained. The microprocessor is controlled by two clocks - the A/D clock, or input sampling clock, which loads the digital input into the input register and presets the counter to a value set by the external switches; and the instruction clock, or system clock, which operates at 6 MHz. At this system clock rate and a sampling clock rate of 30 KHz, 200 instructions can be executed between samples, and for many speech encoding and decoding algorithms, 200 instructions are more than enough. The microcomputer is being used to test various delta modulator encoding algorithms.

Apelewicz, T.↗

Microcomputer helps evaluate skin burns

Microcomputer analysis of multispectral imaging of burn area aids production of display map of field and partial thickness burns making more effective clinical treatment possible.

Anselmo, V. J.↗

The current status of microcomputer arrays

Some research projects on microcomputer arrays are at the stage of constructing hardware, while others are at the design and planning stages. A general overview of the topic is followed by a more detailed discussion of three projects whose purposes are specifically scientific computation.

Knight, J. C.↗

A user oriented microcomputer facility for designing linear quadratic Gaussian feedback compensators

A laboratory design facility for digital microprocessor implementation of linear-quadratic-Gaussian feedback compensators is described. Outputs from user interactive programs for solving infinite time horizon LQ regulator and Kalman filter problems were conditioned for implementation on the laboratory microcomputer system. The software consisted of two parts: an offline high-level program for solving the LQ Ricatti equations and generating associated feedback and filter gains and a cross compiler/macro assembler which generates object code for the target microprocessor system. A PDP 11/70 with a UNIX operating system was used for all high level program and data management, and the target microprocessor system is an Intel MDS (8080-based processor). Application to the control of a two dimensional inverted pendulum is presented and issues in expanding the design/prototyping system to other target machine architectures are discussed.

Houpt, P. K.↗

A distributed microcomputer telemetry system for spacecraft applications

Distributed microcomputer telemetry system design difficulties are examined and solutions to these difficulties are discussed. In the telemetry system being considered, the data gathering is actually distributed among a number of computers, each with its own commutation cycle, data storage buffers, and specified set of measurements to be sampled. A computer based high level module controls the formation of the final telemetry stream by accessing individual computer's data storage buffers at the appropriate time and inserting them into the telemetry stream. Attention is given to the precise time tagging of data samples, the interconnection of several computers, the autonomous operation of science instruments, and reliability considerations.

Lord, D. D.↗

Microcomputer-based doppler systems for weather monitoring

Ground-based microcomputer determines geographical positions of beacons using Doppler data from weather satellites. System requires onnly 7 W and incorporates least-squares iteration to compute positions. Results are printed out in alphanumerics either on CRT or on teletype. 6502 CPU was used, although equivalent processor could be substituted (with appropriate modifications to hardware).

Schmid, P. E.↗

A user oriented microcomputer facility for designing linear quadratic Gaussian feedback compensators

The paper describes a laboratory design facility for digital microprocessor implementation of Linear-Quadratic-Gaussian feedback compensators. Outputs from user interactive programs for solving infinite time horizon LQ regulator and Kalman filter problems are conditioned for implementation on a laboratory microcomputer system. The software consists of two parts: (1) an off-line high-level program for solving the LQ Ricatti equations and generating associated feedback and filter gains, and (2) a cross compiler/macro assembler which generates object code for the target microprocessor system. Application to the control of a two dimensional inverted pendulum and expanding the design/prototyping system to other target machine architectures are discussed.

Houpt, P. K.↗

Microcomputer array processor system

The microcomputer array system is discussed with specific attention given to its electronic warware applications. Several aspects of the system architecture are described as well as some of its distinctive characteristics.

Slezak, K. D.↗

Interactive display of molecular models using a microcomputer system

A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.

Egan, J. T.↗

The Ruggedized STD Bus Microcomputer - A low cost computer suitable for Space Shuttle experiments

Previous space flight computers have been costly in terms of both hardware and software. The Ruggedized STD Bus Microcomputer is based on the commercial Mostek/Pro-Log STD Bus. Ruggedized PC cards can be based on commercial cards from more than 60 manufacturers, reducing hardware cost and design time. Software costs are minimized by using standard 8-bit microprocessors and by debugging code using commercial versions of the ruggedized flight boards while the flight hardware is being fabricated.

Budney, T. J.↗