Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microphonics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Condenser Microphone Protective Grid Correction for High Frequency Measurements

Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

Lee, Erik↗

Use of a Microphone Phased Array to Determine Noise Sources in a Rocket Plume

A 70-element microphone phased array was used to identify noise sources in the plume of a solid rocket motor. An environment chamber was built and other precautions were taken to protect the sensitive condenser microphones from rain, thunderstorms and other environmental elements during prolonged stay in the outdoor test stand. A camera mounted at the center of the array was used to photograph the plume. In the first phase of the study the array was placed in an anechoic chamber for calibration, and validation of the indigenous Matlab(R) based beamform software. It was found that the "advanced" beamform methods, such as CLEAN-SC was partially successful in identifying speaker sources placed closer than the Rayleigh criteria. To participate in the field test all equipments were shipped to NASA Marshal Space Flight Center, where the elements of the array hardware were rebuilt around the test stand. The sensitive amplifiers and the data acquisition hardware were placed in a safe basement, and 100m long cables were used to connect the microphones, Kulites and the camera. The array chamber and the microphones were found to withstand the environmental elements as well as the shaking from the rocket plume generated noise. The beamform map was superimposed on a photo of the rocket plume to readily identify the source distribution. It was found that the plume made an exceptionally long, >30 diameter, noise source over a large frequency range. The shock pattern created spatial modulation of the noise source. Interestingly, the concrete pad of the horizontal test stand was found to be a good acoustic reflector: the beamform map showed two distinct source distributions- the plume and its reflection on the pad. The array was found to be most effective in the frequency range of 2kHz to 10kHz. As expected, the classical beamform method excessively smeared the noise sources at lower frequencies and produced excessive side-lobes at higher frequencies. The "advanced" beamform routine CLEAN-SC created a series of lumped sources which may be unphysical. We believe that the present effort is the first-ever attempt to directly measure noise source distribution in a rocket plume.

Panda, J.↗

Evaluation of Methods for In-Situ Calibration of Field-Deployable Microphone Phased Arrays

Current field-deployable microphone phased arrays for aeroacoustic flight testing require the placement of hundreds of individual sensors over a large area. Depending on the duration of the test campaign, the microphones may be required to stay deployed at the testing site for weeks or even months. This presents a challenge in regards to tracking the response (i.e., sensitivity) of the individual sensors as a function of time in order to evaluate the health of the array. To address this challenge, two different methods for in-situ tracking of microphone responses are described. The first relies on the use of an aerial sound source attached as a payload on a hovering small Unmanned Aerial System (sUAS) vehicle. The second relies on the use of individually excited ground-based sound sources strategically placed throughout the array pattern. Testing of the two methods was performed in microphone array deployments conducted at Fort A.P. Hill in 2015 and at Edwards Air Force Base in 2016. The results indicate that the drift in individual sensor responses can be tracked reasonably well using both methods. Thus, in-situ response tracking methods are useful as a diagnostic tool for monitoring the health of a phased array during long duration deployments.

Humphreys, William M.↗

Networked Array Recorder (NeAR) Microphones for Field-Deployed Phased Arrays

An innovative edge-computing concept known as NeAR (Networked Array Recorder) has been developed to provide enhancements to existing field-deployable microphone phased arrays utilized for aeroacoustic flyover measurements of airframe and propulsive noise sources. The proposed system allows for the elimination of multiple miles of sensor wiring in an array installation, thereby improving the scalability of the overall system, increasing the fault-tolerance of the hardware, and reducing the effort needed to build-up and tear-down an array in the field. A demonstration of the NeAR concept was performed at Edwards Air Force Base in California in March – April, 2018, where twelve individual NeAR microphones were deployed as a piggyback on a conventional phased array system deployed for airframe noise flyover testing. The microphones operated successfully during the demonstration with good time history and spectral correlations shown between the NeAR units and conventional microphones located nearby in the array. The NeAR concept has spinoffs beyond its use for phased arrays, including applications in remote environmental sensing and noise monitoring.

Cull.iton, William G.↗

Eliminating flow-induced microphonics in a superfluid helium cryogenic system

Superconducting radio frequency cavities are the devices of choice when it comes to accelerating charged particle beams in modern particle accelerators. They are held in a bath of liquid helium, to maintain their operating temperature at 2.0 K. The dimensions of these cavities are controlled within microns to facilitate operation at design conditions. During operation however, these cavities experience microphonic disturbances i.e., small mechanical deformations, that cause an undesired response in the electrical performance of the cavity. This paper proposes solutions to mitigate microphonics caused by fluid flow, particularly by the fill line into the helium bath in a 2.0 K cryogenic system. Specifically, three different systems designs are proposed, two of which dramatically reduce vapor generation and thereby its contribution to microphonics. The third design is found to completely suppress vapor generation and is explored in further detail.

09 BIOMASS FUELS↗

A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive

For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.

47 OTHER INSTRUMENTATION↗

MICROPHONICS TESTING OF LCLS II CRYOMODULES AT JLAB

Jefferson Lab is partnering with Fermilab to build 40 cryomodules for the LCLS II accelerator that will be installed at the Stanford Linear Accelerator (SLAC). The LCLS II cryomodule is an 8-seat CW cryomodule which operates at 1300 MHz and is based on the XFEL design. The cavities have design loaded-Q of 4×107, which means that it has a control bandwidth of 16 Hz. The JLab prototype cryomodule was instrumented with a series of 10 accelerometers, and impulse hammer response measurements were made while the cryomodule was being built and after it was installed in the JLAB cryomodule test facility. This was done so that we could better understand the shapes of the modes of the structure. These results were compared to impulse hammer testing from the outside of the cryomodule to individual cavity frequency shifts when the cryomodule was cold. Additionally, background microphonics and transfer function measurements were made on several other LCLS II cryomodules in the JLab cryomodule test facility (CMTF). The prototype cryomodule had excessive microphonics up to 100 Hz peak due to a thermo-acoustic oscillation in the cryogenic supply circuit. Design modifications were implemented and subsequently the cryomodules had microphonics on the order of 10 to 20 Hz.

Powers, Thomas↗

Device enables calibration of microphones at high sound pressure levels

Coupling device accurately calibrates microphones at high sound pressure intensities. The system which uses a liquid as the coupling medium can operate in an automatic mode by using a standard microphone as a control sensor. Feedback from the standard microphone controls the calibration signal level.

Gillen, A.↗

A four-element end-fire microphone array for acoustic measurements in wind tunnels

A prototype four-element end-fire microphone array was designed and built for evaluation as a directional acoustic receiver for use in large wind tunnels. The microphone signals were digitized, time delayed, summed, and reconverted to analog form in such a way as to create a directional response with the main lobe along the array axis. The measured array directivity agrees with theoretical predictions confirming the circuit design of the electronic control module. The array with 0.15 m (0.5 ft) microphone spacing rejected reverberations and background noise in the Ames 40- by 80-foot wind tunnel by 5 to 12 db for frequencies above 400 Hz.

Soderman, P. T.↗

Study of a porous surface microphone sensor in an aerofoil

The porous microphone in an airfoil is described as a directional sensor which rejects flow noise. The airfoil allows the sensor to be rotated in the airflow over a wide range of yaw angles, 0 to 90 degrees, avoiding flow separation over the surface of the sensor and its associated additional flow noise. The microphone is discussed in terms of its acoustic properties, vibration sensitivity, effect of Mach number on the directivity function, and flow noise. Additional information on the acoustic calibration of the microphone, the acceleration sensitivity of the airfoil, stationary source and receiver in a moving gas, acoustic tests in airflow, and flow noise tests of the airfoil porous surface sensor is included.

Noiseux, D. U.↗

Sound scattering by rigid oblate spheroids, with implication to pressure gradient microphones

The frequency limit below which sound scattering by a microphone body is sufficiently small to permit accurate pressure gradient measurements was determined. The sound pressure was measured at various points on the surface of a rigid oblate spheroid illuminated by spherical waves generated by a point source at a large distance from the spheroid, insuring an essentially plane sound field. The measurements were made with small pressure microphones flush mounted from the inside of the spheroid model. Numerical solutions were obtained for a variety of spheroid shapes, including that of the experimental model. Very good agreement was achieved between the experimental and theoretical results. It was found that scattering effects are insignificant if the ratio of the major circumference of the spheroid to the wavelength of the incident sound is less than about 0.7, this number being dependent upon the shape of the spheroid. This finding can be utilized in the design of pressure gradient microphones.

Maciulaitis, A.↗

Investigation of continuously traversing microphone system for mode measurement

The continuously Traversing Microphone System consists of a data acquisition and processing method for obtaining the modal coefficients of the discrete, coherent acoustic field in a fan inlet duct. The system would be used in fan rigs or full scale engine installations where present measurement methods, because of the excessive number of microphones and long test times required, are not feasible. The purpose of the investigation reported here was to develop a method for defining modal structure by means of a continuously traversing microphone system and to perform an evaluation of the method, based upon analytical studies and computer simulated tests. A variety of system parameters were examined, and the effects of deviations from ideal were explored. Effects of traverse speed, digitizing rate, run time, roundoff error, calibration errors, and random noise background level were determined. For constant fan operating speed, the sensitivity of the method to normal errors and deviations was determined to be acceptable. Good recovery of mode coefficients was attainable. Fluctuating fan speed conditions received special attention, and it was concluded that by employing suitable time delay procedures, satisfactory information on mode coefficients can be obtained under realistic conditions. A plan for further development involving fan rig tests was prepared.

Cicon, D. E.↗

Quick-Change Holder for Aeronautical-Research Microphones

Mounting holds microphone flush with aircraft surface and maintains pressure seal. Microphones, which measure dynamic pressure and shock waves as they pass over aircraft fuselage or other experimental body, mounted through fuselage flush with outside surface. Besides being faster and easier to use than older mounts, new mount prevents damage to microphone on removal because no sealant to be cut and scraped away.

Cohn, R.↗

Noise path identification using face-to-face and side-by-side microphone arrangements

In large complex structures, with several major sound transmission paths and high levels of background noise, it can be a complex task to locate and rank the contribution of an individual sound transmission path. The two microphone acoustic intensity techniques are investigated as a tool for path identification. Laboratory tests indicate that, if the intensity transmitted through a particular section of the fuselage is measured in the presence and absence of flanking paths using the face to face and side by side microphone arrangements, then no significant difference exists between the two measured intensities if the face to face microphone arrangement is used. However, if the side by side arrangement is used, then considerable difference exists between the two measured intensities.

Atwal, M.↗

Carbon granule probe microphone for leak detection

A microphone which is not subject to corrosion is provided by employing carbon granules to sense sound waves. The granules are packed into a ceramic tube and no diaphragm is used. A pair of electrodes is located in the tube adjacent the carbon granules and are coupled to a sensing circuit. Sound waves cause pressure changes on the carbon granules which results in a change in resistance in the electrical path between the electrodes. This change in resistance is detected by the sensing circuit. The microphone is suitable for use as a leak detection probe in recovery boilers, where it provides reliable operation without corrosion problems associated with conventional microphones.

Parthasarathy, S. P.↗

High temperature fiber optic microphone having a pressure-sensing reflective membrane under tensile stress

A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a backplate for damping membrane motion. The backplate further provides a means for on-line calibration of the microphone.

Zuckerwar, Allan J.↗

Developments on high temperature fiber optic microphone

A fiber optic microphone, based on the principle of the fiber optic lever, features small size, extended bandwidth, and capability to operate at high temperatures. These are requirements for measurements in hypersonic flow. This paper describes the principles of operation of fiber optic sensors, a discussion of the design of a fiber optic microphone, the functional elements and packaging techniques of the optoelectronic circuitry, and the calibration techniques used in the development of the high temperature fiber optic microphone.

Wright, Kenneth D., II↗

Fiber optic microphone having a pressure sensing reflective membrane and a voltage source for calibration purpose

A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.

Zuckerwar, Allan J.↗