Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microplasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microplasma-based flowing atmospheric-pressure afterglow (FAPA) source for ambient desorption-ionization mass spectrometry

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a timeof- flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. Here, the mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-pulsing 10{sup 4} A cm{sup -2} current density discharges in dielectric barrier Al/Al{sub 2}O{sub 3} microplasma devices

Excitation of Al/Al{sub 2}O{sub 3} microplasma devices with 50 {mu}s, 800 V pulses produces, in Ar/H{sub 2} gas mixtures at 600 Torr, {approx}6 A current pulses with a duration of {approx}30 ns. Corresponding to peak current and power densities of {approx}10{sup 4} A/cm{sup 2} and {approx}2.5 GW/cm{sup 3}, respectively, these pulses are generated in a 10 {mu}s burst in which the voltage self-pulses at a repetition frequency of {approx}3 MHz. Analysis of the H{sub {alpha}}, H{sub {beta}}, and Ar II emission line profiles yields a plasma density of {approx}10{sup 17} cm{sup -3}, and the emission of O IV ions suggests the presence of energetic electrons. Images of the microplasma indicate that the plasma is initiated by surface flashover and extends {approx}200 {mu}m outside the microcavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutral gas heating in helium microplasmas

The present study details a self-consistent model of charged and neutral particle dynamics which is applied to atmospheric small-space (200 {mu}m) discharges in helium. Hydrodynamic transport equations of the self-consistent and time-dependant model are described with an emphasis on the different terms involved in the close coupling among charged species, neutral species, and the electric field. Those equations are solved by two-dimensional numerical schemes for both species transport and electric field. The microplasmas are studied from an initial cloud until the stages of charged particle overamplification in small spaces, where transients are particularly important. Gas heating, neutral depletion initiation, and electric field reversal are observed, highlighting the close interaction between neutral gas and charged species in governing the evolution of the microplasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

White light emission from silicon oxycarbide films prepared by using atmospheric pressure microplasma jet

An atmospheric pressure microplasma jet was employed as a deposition tool to fabricate silicon oxycarbide films from tetraethoxysilane-argon (Ar) mixture gas at room temperature. Resultant films exhibit intense visible emission under a 325 nm excitation which appears white to naked eyes in the range from {approx}1.75 to {approx}3.5 eV at room temperature. The origin of photoluminescence is attributed to the electron-hole pair recombination through neutral oxygen vacancies (NOVs) in the film. The density of NOV defects was found in the range from 3.48x10{sup 15} to 2.23x10{sup 16} cm{sup -3}. The photoluminescence quantum efficiencies were estimated to be 1.48%-4.15%. Present experiment results demonstrate that the silicon oxycarbide films prepared by using atmospheric pressure microplasma jet would be a competitive candidate for the development of white light emission devices.

36 MATERIALS SCIENCE↗

Development of a dielectric-barrier discharge enhanced microplasma jet

A low-power ultrahigh-frequency-driven inductively coupled microplasma (ICMP) source equipped with dielectric-barrier discharge (DBD) was developed to realize a low-temperature and high-density plasma in fine quartz capillaries with inner diameters of less than 1.0 mm. A stable plasma was generated and its sustainability was independent of the gas flow rate. This plasma jet had a longer plume than that of a thermoelectron-enhanced microplasma jet, and time-resolved characterization suggested interactions between ICMP and DBD jets. By optical emission spectroscopy characterization, the gas temperature and electron density inside a capillary were estimated to be 400-1000 K and 10{sup 13}-10{sup 14} cm{sup -3}, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilization of the ionization overheating thermal instability in atmospheric pressure microplasmas

Stable direct current atmospheric pressure plasmas can regularly be generated in air using microplasma systems, and rapid cooling due to the small size is typically suggested as the thermally stabilizing mechanism. However, temperatures of the stable discharges are significantly higher than ambient, and stable operation is not easily achieved in all gases at similar sizes. Revisiting a traditional analysis of the thermal instability, we find that the inclusion of the simple ballasted external circuit in the analysis leads to additional stabilizing mechanisms. This stabilization occurs in microplasmas due to the characteristic times of the external circuit and the instability being comparable, which allows the electric field to change during the time frame of the instability. Experimentally this is implemented by reducing the stray capacitance of the external circuit. This stabilizing mechanism is verified in several gases and its application in a plasma enhanced chemical vapor deposition system leads to a more uniform film deposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast Space-time and Spectrum-time Resolved Diagnostics of Multicharged Femtosecond Laser Microplasma

We present the review of the recent experimental studies of fundamental mechanisms of femtosecond laser plasma formation and evolution performed in A. M. Prokhorov General Physics Institute of Russian Academy of Sciences. The main object we dealt with was the micro-sized plasma produced in gases with high intensity (up to 5x10{sup 17} W/cm{sup 2}), tightly focused (to a few microns in diameter) IR and UV femtosecond laser pulses. The main attention in the experiments was paid to the initial stage of microplasma formation and evolution characterized by strong laser-plasma coupling resulting in efficient ionization and heating of the medium, distortion of laser beam, and nonlinear spectral conversion of laser radiation to the continuum and laser harmonics. Using a precise pump-probe micro-interferometric technique the dynamics of plasma was studied with femtosecond time-resolution in a wide density range--from a minimal detectable electron concentration (10{sup 19} cm{sup -3}) to the almost total (down to nuclei) ionization of ions occurred under femtosecond excitation. The obtained time-dependences of plasma density were analyzed. It was observed, for the first time, that a characteristic time of femtosecond laser plasma formation in gases considerably (in times) exceeds the duration of the pump laser pulse. This postionization process is attributed to impact ionization of plasma by hot electrons. We compare the results of the experiments with what the developed theory predicts. Using an ultrafast streak-camera-based spectroscopy technique the temporal evolution of microplasma emission and the dynamics of spectral lines formation in UV-visible range were studied with picosecond time-resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical and electrical characterization of an atmospheric pressure microplasma jet with a capillary electrode

A microplasma jet with a capillary electrode working at atmospheric pressure is developed to create nonthermal plasma. This jet can be operated at an excitation frequency either in several tens of kilohertz ac range (or pulsed voltage with a repetition rate of kilohertz range) or in radio-frequency range. The working gas, helium or argon, and the additive gas, oxygen, are fed into the plasma jet. The discharge has been characterized by optical emission spectroscopy. The electrical property of the discharge has been studied by means of voltage and current probes. The dynamic nature of the plume is investigated by using intensified charged coupled device camera. The electron temperature is estimated from the modified Boltzmann plot method utilizing the Ar 4p->4s transitions. The plume temperature is determined by using the fitting the fine structure of the emission bands of OH molecules and by utilizing the line shape of the transition. They are compared with the results obtained by optical fiber thermometer. The characteristics of plasma jet are studied by employing different excitation mode and by adjusting the gas flow rates, the applied voltage, and the amount of additive O{sub 2} flow. The characteristic differences between the Ar plasma jet and the He plasma jet are compared. The effects of the additive O{sub 2} gas are investigated. The plasma bullet velocity is found to increase with the applied voltage but to decrease with the duty cycle. Also the preliminary results of microplasma effects on the human breast cancer cells are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

4D Density Determination of NH Radicals in an MSE Microplasma Combining Planar Laser Induced Fluorescence and Cavity Ring-Down Spectroscopy

An application of microplasmas is surface modification under mild conditions and of small, well defined areas. For this, an understanding of the plasma composition is of importance. First results of our work on the production and detection of NH radicals in a capacitively coupled radio frequency (RF) microplasma are presented. A microstructured comb electrode was used to generate a glow discharge in a hydrogen/nitrogen gas mixture by applying 13.56 MHz RF voltage. The techniques of planar laser induced fluorescence (PLIF) and cavity ring-down spectroscopy (CRDS) are used for space and time resolved, quantitative detection of the NH radical in the plasma. The rotational temperature was determined to be 820 K and, the density 5.1x10{sup 12} cm{sup 3}. Also, time dependent behaviour of the NH production was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron heating mode transition induced by ultra-high frequency in atmospheric microplasmas for biomedical applications

The electron heating mode transition induced by ultra-high frequency in atmospheric-pressure microplasmas was investigated using particle-in-cell simulation with a Monte Carlo collision. Interestingly, this discharge mode transition is accompanied by non-monotonic evolution of electron kinetics such as effective electron temperature, plasma density, and electron energy on the electrode. In this study, the highest flux of energetic electrons ({epsilon} > 4 eV) usable for tailoring the surface chemistry in atmospheric microplasmas is obtained at the specific frequency (400 MHz), where an optimal trade-off is established between the amplitude of sheath oscillations and the power coupled to electrons for sub-millimeter dimensions (200 {mu}m).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of cathode geometry to minimize cathode erosion in direct current microplasma jet

Microplasma jets are now widely used for deposition, etching, and materials processing. The present study focuses on the investigation of the influence of cathode geometry on deposition quality, for microplasma jet deposition systems in low vacuum. The interest here is understanding the influence of hydrogen on sputtering and/or evaporation of the electrodes. Samples obtained with two cathode geometries with tapered and rectangular cross-sections have been investigated experimentally by scanning electron microscopy and energy dispersion X-ray spectroscopy. Samples obtained with a tapered-geometry cathode present heavy contamination, demonstrating cathode erosion, while samples obtained with a rectangular-cross-section cathode are free from contamination. These experimental characteristics were explained by modelling results showing a larger radial component of the electric field at the cathode inner wall of the tapered cathode. As a result, ion acceleration is larger, explaining the observed cathode erosion in this case. Results from the present investigation also show that the ratio of radial to axial field components is larger for the rectangular geometry case, thus, qualitatively explaining the presence of micro-hollow cathode discharge over a wide range of currents observed in this case. In the light of the above findings, the rectangular cathode geometry is considered to be more effective to achieve cleaner deposition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cathode fall model and current-voltage characteristics of field emission driven direct current microplasmas

The post-breakdown characteristics of field emission driven microplasma are studied theoretically and numerically. A cathode fall model assuming a linearly varying electric field is used to obtain equations governing the operation of steady state field emission driven microplasmas. The results obtained from the model by solving these equations are compared with particle-in-cell with Monte Carlo collisions simulation results for parameters including the plasma potential, cathode fall thickness, ion number density in the cathode fall, and current density vs voltage curves. The model shows good overall agreement with the simulations but results in slightly overpredicted values for the plasma potential and the cathode fall thickness attributed to the assumed electric field profile. The current density vs voltage curves obtained show an arc region characterized by negative slope as well as an abnormal glow discharge characterized by a positive slope in gaps as small as 10 μm operating at atmospheric pressure. The model also retrieves the traditional macroscale current vs voltage theory in the absence of field emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a chip-based ingroove microplasma source: Design, characterization, and diagnostics

A chip-based ingroove microplasma source was designed for molecular emission spectrometry by using a space-confined direct current duct in air. The voltage-current characteristics of different size generators, emission spectroscopy of argon were discussed, respectively. It is found that the emission intensity of excited Ar and N{sub 2} approaches its maximum near the cathode, while OH and O peaks most likely appear close to the anode. The electron density, electronic excitation temperature, rotational temperature, and vibrational temperature of the argon plasma were also calculated. More importantly, the chip-based ingroove microplasma shows much better stability compared with its counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the stability of microplasma device utilizing diamond coated carbon nanotubes as cathode materials

This paper reports the enhanced stability of a microplasma device by using hybrid-granular-structured diamond (HiD) film coated carbon nanotubes (CNTs) as cathode, which overcomes the drawback of short life time in the CNTs-based one. The microplasma device can be operated more than 210 min without showing any sign of degradation, whereas the CNTs-based one can last only 50 min. Besides the high robustness against the Ar-ion bombardment, the HiD/CNTs material also possesses superior electron field emission properties with low turn-on field of 3.2 V/μm, which is considered as the prime factor for the improved plasma illumination performance of the devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Obtaining composite Zr-Al-O coating on the surface of zirconium by microplasma oxidation

The paper describes the application of the microplasma oxidation for production of Zr-Al-O composition on the surface of zirconium. Certification of a new-type power supply for depositing oxide ceramic coatings by microplasma oxidation was also carried out. The growth rate of Zr-Al-O coating amounted around 0.2 nm/s, which around 10 times exceeds that for depositing similar coatings using the similar equipment. We have studied the change of surface morphology and the chemical composition of the formed ceramic coating by means of EVO 50 scanning electron microscope and X-ray spectral analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of nonlocal helium microplasma for gas impurities detection by the collisional electron spectroscopy method

The collisional electron spectroscopy (CES) method, which lays the ground for a new field for analytical detection of gas impurities at high pressures, has been verified. The CES method enables the identification of gas impurities in the collisional mode of electron movement, where the advantages of nonlocal formation of the electron energy distribution function (EEDF) are fulfilled. Important features of dc negative glow microplasma and probe method for plasma diagnostics are applied. A new microplasma gas analyzer design is proposed. Admixtures of 0.2% Ar, 0.6% Kr, 0.1% N{sub 2}, and 0.05% CO{sub 2} are used as examples of atomic and molecular impurities to prove the possibility for detecting and identifying their presence in high pressure He plasma (50–250 Torr). The identification of the particles under analysis is made from the measurements of the high energy part of the EEDF, where maxima appear, resulting from the characteristic electrons released in Penning reactions of He metastable atoms with impurity particles. Considerable progress in the development of a novel miniature gas analyzer for chemical sensing in gas phase environments has been made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗