Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microprobe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deep Space 2: The Mars Microprobe Project and Beyond

The Mars Microprobe Project, or Deep Space 2 (DS2), is the second of the New Millennium Program planetary missions and is designed to enable future space science network missions through flight validation of new technologies. A secondary goal is the collection of meaningful science data. Two micropenetrators will be deployed to carry out surface and subsurface science. The penetrators are being carried as a piggyback payload on the Mars Polar Lander cruise ring and will be launched in January 1999. The microprobe has no active control, attitude determination, or propulsive systems. It is a single stage from separation until landing and will passively orient itself due to its aerodynamic design. The aeroshell will be made of a nonerosive heat shield material, Silicon impregnated Reusable Ceramic Ablator(SIRCA), developed at Ames Research Center. The aeroshell shatters on impact, at which time the probe separates into an aftbody that remains at the surface and a forebody that penetrates into the subsurface. Each probe has a total mass of up to 3 kg, including the aeroshell. The impact velocity will be about 180 meters per second. The forebody will experience up to 30,000 g's and penetrate between 0.3 and 2 meters, depending on the ice content of the soil. The aftbody deceleration will be up to 80,000 g. The penetrators arrive in December 1999. The landing ellipse latitude range is 73 deg-77 deg S. The longitude will be selected by the Mars Surveyor Project to place the lander on the polar layered deposits in the range of 180 deg -230 deg W. The two micropenetrators are likely to land within 100 km of the Mars Surveyor Lander, on the polar deposits. The likely arrival date is L(sub s) = 256, late southern spring. The nominal mission lasts 2 days. A science team was selected in April 1998.

Smrekar, S. E.↗

Mars Microprobe Entry Analysis

The Mars Microprobe mission will provide the first opportunity for subsurface measurements, including water detection, near the south pole of Mars. In this paper, performance of the Microprobe aeroshell design is evaluated through development of a six-degree-of-freedom (6-DOF) aerodynamic database and flight dynamics simulation. Numerous mission uncertainties are quantified and a Monte-Carlo analysis is performed to statistically assess mission performance. Results from this 6-DOF Monte-Carlo simulation demonstrate that, in a majority of the cases (approximately 2-sigma), the penetrator impact conditions are within current design tolerances. Several trajectories are identified in which the current set of impact requirements are not satisfied. From these cases, critical design parameters are highlighted and additional system requirements are suggested. In particular, a relatively large angle-of-attack range near peak heating is identified.

Braun, Robert D.↗

Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

Fournelle, John↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

The New Millennium Program's Mars Microprobe Mission

The second deep-space advanced technology validation mission in NASA's New Millennium Program will demonstrate planetary micropenetrator technologies. Two microprobes, each consisting of a very low mass aeroshell and penetrator system, are planned to launch in January 1999 and arrive at Mars in December 1999. This paper will summarize key features of the microprobe mission and system design, as well as discuss the technologies proposed for flight.

Mars↗

Asymmetric Distribution of Metals in the Xenopus Laevis Oocyte: a Synchrotron X-Ray Fluorescence Microprobe Study

The asymmetric distribution of many components of the Xenopus oocyte, including RNA, proteins, and pigment, provides a framework for cellular specialization during development. During maturation, Xenopus oocytes also acquire metals needed for development, but apart from zinc, little is known about their distribution. Synchrotron X-ray fluorescence microprobe was used to map iron, copper, and zinc and the metalloid selenium in a whole oocyte. Iron, zinc, and copper were asymmetrically distributed in the cytoplasm, while selenium and copper were more abundant in the nucleus. A zone of high copper and zinc was seen in the animal pole cytoplasm. Iron was also concentrated in the animal pole but did not colocalize with zinc, copper, or pigment accumulations. This asymmetry of metal deposition may be important for normal development. Synchrotron X-ray fluorescence microprobe will be a useful tool to examine how metals accumulate and redistribute during fertilization and embryonic development.

43 PARTICLE ACCELERATORS↗

Asymmetri Distribution of Metals in the Xenopus Laevis Oocyte: a Synchrotron X-Ray Fluorescence Microprobe Study

The asymmetric distribution of many components of the Xenopus oocyte, including RNA, proteins, and pigment, provides a framework for cellular specialization during development. During maturation, Xenopus oocytes also acquire metals needed for development, but apart from zinc, little is known about their distribution. Synchrotron X-ray fluorescence microprobe was used to map iron, copper, and zinc and the metalloid selenium in a whole oocyte. Iron, zinc, and copper were asymmetrically distributed in the cytoplasm, while selenium and copper were more abundant in the nucleus. A zone of high copper and zinc was seen in the animal pole cytoplasm. Iron was also concentrated in the animal pole but did not colocalize with zinc, copper, or pigment accumulations. This asymmetry of metal deposition may be important for normal development. Synchrotron X-ray fluorescence microprobe will be a useful tool to examine how metals accumulate and redistribute during fertilization and embryonic development.

43 PARTICLE ACCELERATORS↗

Processing of electron microprobe data from the analysis of altered cementitious materials

The purpose of this paper is to present a method for processing electron microprobe data coming from the analysis of degraded cementitious materials. The application domain is that of cement matrices exposed to attack by aggressive media inducing the leaching of one or more chemical elements from the cement paste - typically attacked by neutral or acid aqueous environments. As raw data obtained from electron probe microanalysis (EPMA) come in the form of relative quantities of elements, the aim of the processing is to obtain the absolute variation of the specimen's chemical composition in the degraded zone and consequently to allow a better understanding of the degradation mechanisms by the aggressive environment under consideration. This method was designed for degraded specimens in which the porosity was not filled with resin before the EPMA. The method uses the titanium content of the cement matrix as a control, this element being stable during attack by neutral or acidic media. The method is described in detail using the example of the attack of cement pastes by a mix of several organic acids (notably acetic acid) at pH 4. The use of EPMA for sound and altered cement pastes is also validated. The application domain of the correction method is discussed.

36 MATERIALS SCIENCE↗

High definition large area mapping of geological samples using a Maia detector array in the Nuclear Microprobe

A Maia detector array has been utilized and installed on the CSIRO-MARC Nuclear Microprobe. Maia uses an annular array of 384 silicon detectors to provide a solid-angle of 1.3 sr to improve the collection of X-rays induced by Particle Induced X-ray Emission (PIXE) using a micron focussed MeV proton beam. It features event-by-event data acquisition with dead-time correction and pileup rejection and a total count-rate capacity above 10 M/s, versatile stage and beam scanning modes (coupled to the DAQ-36 system described previously) to cater for a variety of sample configuration and experimental needs, precise measurement of transit time and integration of beam fluence per pixel, and spectral deconvolution of event data in real-time using the Dynamic Analysis method to provide element images during data collection. In this work we demonstrate the system on thin sections made from geological samples extracted from active seafloor hydrothermal vents in the PACMANUS hydrothermal field in Papua New Guinea.

36 MATERIALS SCIENCE↗

Deep Space 2: The Mars Microprobe Mission

The Mars Microprobe Mission will be the second of the New Millennium Program's technology development missions to planetary bodies. The mission consists of two penetrators that weigh 2.4 kg each and are being carried as a piggy back payload on the Mars Polar Lander cruise ring.

Mars↗

Mars Microprobe Project Instrumentation Package

The Mars Microprobe Project is a technology validation mission in NASA's New Millennium Program. The project is developing a pair of small, two-piece probes for delivery to the surface of Mars in December of 1999.

Mars↗

Combined Chemical and Topographic Imaging at Atmospheric Pressure via Microprobe Laser Desorption/Ionization Mass Spectrometry-Atomic Force Microscopy

The operational characteristics and imaging performance are described for a new instrument comprising an atomic force microscope (AFM) coupled with a pulsed laser and a linear ion trap mass spectrometer. The AFM operating mode is used to produce topographic surface images having nanometer-scale spatial and height resolution. Spatially resolved mass spectra of ions, produced from the same surface via microprobe-mode laser desorption/ionization at atmospheric pressure, are then used to create a 100 x 100 m chemical image. The effective spatial resolution of the image (~2 m) was constrained by the limit of detection (estimated to be 109 1010 ions) rather than by the diameter of the focused laser spot or the step size of the AFM sample stage. Thus, it is expected that improvements in imaging performance can be realized by implementation of post-ionization methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved X-ray diffraction microprobe studies of the conversion of cellulose I to ethylenediamine-cellulose I

Structural changes during the treatment of films of highly crystalline microfibers of Cladophora cellulose with ethylenediamine (EDA) have been studied by time-resolved X-ray microprobe diffraction methods. As EDA penetrates the sample and converts cellulose I to EDA-cellulose I, the measured profile widths of reflections reveal changes in the shapes and average dimensions of cellulose I and EDA-cellulose I crystals. The (200) direction of cellulose I is most resistant to EDA penetration, with EDA penetrating most effectively at the hydrophilic edges of the hydrogen bonded sheets of cellulose chains. Most of the cellulose chains in the initial crystals of cellulose I are incorporated into crystals of EDA-cellulose I. The size of the emerging EDA-cellulose I crystals is limited to about half of their size in cellulose I, most likely due to strains introduced by the penetration of EDA molecules. There is no evidence of any gradual structural transition from cellulose I to EDA-cellulose I involving a continuously changing intermediate phase. Rather, the results point to a rapid transition to EDA-cellulose I in regions of the microfibrils that have been penetrated by EDA.

08 HYDROGEN↗

Microprobe Analysis of Pu-Ga Standards

In order to obtain quantitative analysis using an Electron Scanning Microprobe it is essential to have a standard of known composition. Most elemental and multi-elemental standards can be easily obtained from places like Elemental Scientific or other standards organizations that are NIST (National Institute of Standards and Technology) traceable. It is, however, more challenging to find standards for plutonium. Past work performed in our group has typically involved using the plutonium sample to be analysed as its own standard as long as all other known components of the sample have standards to be compared to [1,2,3]. Finally, this method works well enough, but this experiment was performed in order to develop a more reliable standard for plutonium using five samples of known chemistry of a plutonium gallium mix that could then be used as the main plutonium and gallium standards for future experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Crystallographic, Scanning Microprobe X-ray Diffraction, and Cross-Polarized/Magic Angle Spinning [superscript 13]C NMR Studies of the Structure of Cellulose III[subscript II]

The X-ray crystallographic structure of cellulose III{sub II} is characterized by disorder; the unit cell (space group P2{sub 1}; a = 4.45 {angstrom}, b = 7.64 {angstrom}, c = 10.36 {angstrom}, {alpha} = {beta} = 90{sup o}, {gamma} = 106.96{sup o}) is occupied by one chain that is the average of statistically disordered antiparallel chains. {sup 13}C CP/MAS NMR studies reveal the presence of three distinct molecular conformations that can be interpreted as a mixture of two different crystal forms, one equivalent to cellulose III{sub I}, and another with two independent glucosyl conformations in the asymmetric unit. Both X-ray crystallographic and {sup 13}C NMR spectroscopic results are consistent with an aggregated microdomain structure for cellulose III{sub II}. This structure can be generated from a new crystal form (space group P2{sub 1}; a = 4.45 {angstrom}, b = 14.64 {angstrom}, c = 10.36 {angstrom}, {alpha} = {beta} = 90{sup o}, {gamma} = 90.05{sup o}; two crystallographically independent and antiparallel chains; gt hydroxymethyl groups) by multiple dislocation defects. These defects produce microdomains of the new crystal form and cellulose III{sub I} that scanning microprobe diffraction studies show are distributed consistently through the cellulose III{sub II} fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗