Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Annual Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP 1 regulations is managed by the Radionuclide Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. This memo documents the most recent performance tests of the sulfur hexafluoride detectors for use in stack gas mixing tests, as well as the functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Irradiation Tests of Mixed-Oxide Fuel Prepared with Weapons-Derived Plutonium

Mixed oxide (MOX) test capsules prepared with weapons-derived plutonium have been irradiated to a burnup of 50 GWd/MT. The MOX fuel was fabricated at Los Alamos National Laboratory by a master-mix process and irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). Previous withdrawals of the same fuel have occurred at 9, 21, 30, and 50 GWd/MT. Oak Ridge National Laboratory managed this test series for the Department of Energy's Fissile Materials Disposition Program (FMDP). This paper describes the preparation of the MOX fuel, the equipment desig, and the irradiation history of the test capsules and discusses the significance of the more important observations of the post-irradiation examinations (PIEs). Fuel performance has been excellent and consistent with code predictions and with existing U.S. and Europen experience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refinements to the Mixed-Mode Bending Test for Delamination Toughness

The mixed-mode bending (MMB) test for delamination toughness was first introduced in 1988. This simple test is a combination of the standard Mode I (opening) test and a Mode II (sliding) test. This MMB test has become widely used in the United States and around the world for mixed-mode toughness measurements. Because of the widespread use of this test method, it is being considered for standardization by ASTM Committee D30. This paper discusses several improvements to the original test method. The improvements to the MMB test procedure include an improved method for calculating toughness from the measured test quantities, a more accurate way of setting the mixed-mode ratio to be tested, and the inclusion of a new alignment criterion for improved consistency in measured values.

Reeder, James R.↗

Full load testing in the platform module prior to tow-out: A case history of subsynchronous instability

An electric motor driven centrifugal compressor to supply gas for further compression and reinjection on a petroleum production platform in the North Sea was examined. The compressor design, raised concerns about susceptibility to subsynchronous instability. Log decrement, aerodynamic features, and the experience of other compressors with similar ratios of operating to critical speed ratio versus gas density led to the decision to full load test. Mixed hydrocarbon gas was chosen for the test to meet discharge temperature restrictions. The module was used as the test site. Subsynchronous vibrations made the compressor inoperable above approximately one-half the rated discharge pressure of 14500 kPa. Modifications, which includes shortening the bearing span, change of leakage inlet flow direction on the back to back labyrinth, and removal of the vaned diffusers on all stages were made simultaneously. The compressor is operating with satisfactory vibration levels.

Fulton, J. W.↗

Redesign of the mixed-mode bending test for delamination toughness

The mixed-mode bending (MMB) test uses a lever to simultaneously apply mode I and mode II loading to a split-beam specimen. A nonlinear, iterative analysis that accurately predicts the measured load-displacement response and the strain energy release rate, G, of an MMB test, has shown that the errors in G calculated using linear theory can be quite large. The nonlinear analysis was used as a guide in redesigning the MMB apparatus. With the redesigned apparatus, loads are applied through a roller attached to the lever and loaded just above the midplane of the test specimen. The redesigned MMB apparatus has geometric nonlinearity errors of less than 3 percent, even for materials substantially tougher than APC2 (AS4/PEEK). This apparatus was demonstrated by measuring the mixed-mode delamination fracture toughness of APC2. The data from the redesigned MMB apparatus were analyzed with a linear analysis which yielded results similar to those found with the original apparatus and the nonlinear analysis.

Reeder, J. R.↗

A STATISTICAL INTELLIGENCE (STI) APPROACH TO DISCOVERING SPURIOUS CORRELATION IN A PHYSICAL MODEL AND RESOLVING THE PROBLEM WITH AN EXAMPLE OF DESIGNING A PULSE JET MIXING SYSTEM AT HANFORD

Pulse jet mixing tests were conducted to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant. A physical approach (based on hydro-dynamic behavior) and two semi-empirical (SE) approaches were applied to the data to develop models for predicting two response variables (critical-suspension velocity and cloud height). Tests were conducted at three geometric scales using multiple noncohesive simulants and levels of possibly influential factors. The physical modeling approach based on hydro- dynamic behavior was first attempted, but this approach can yield models with spurious correlation. To overcome this dilemma, two semi-empirical (SE) models were developed by generalizing the form of the physical model using dimensional and/or nondimensional (ND) variables. The results of applying statistical intelligence (STI) tools to resolve the spurious correlation problem via fitting the physical and SE models are presented and compared. Considering goodness-of-fit, prediction performance, spurious correlation, and the need to extrapolate, the SE models based on ND variables are recommended.

multiple regression↗

OSU High Temperature Test Facility Test Acceptance Report, PG-30 Low Power (<350kW) Lower Plenum Mixing, Constant Temperature Test

Test Acceptance Report for Test PG-30 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Waste Feed Delivery Small Scale Mixing Demonstration Simulant to Hanford Waste

The Hanford double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions' Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems. A series of these tests have used a five-part simulant composed of particles of different size and density and designed to be equal or more challenging than AY-102 waste. This five-part simulant, however, has not been compared with the broad range of Hanford waste, and thus there is an additional uncertainty that this simulant may not be as challenging as the most difficult Hanford waste. The purpose of this study is to quantify how the current five-part simulant compares to all of the Hanford sludge waste, and to suggest alternate simulants that could be tested to reduce the uncertainty in applying the current testing results to potentially more challenging wastes.

Hanford Waste↗

Comparison of Waste Feed Delivery Small Scale Mixing Demonstration Simulant to Hanford Waste (Rev.1)

The Hanford double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions' Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems. A series of these tests have used a five-part simulant composed of particles of different size and density and designed to be equal or more challenging than AY-102 waste. This five-part simulant, however, has not been compared with the broad range of Hanford waste, and thus there is an additional uncertainty that this simulant may not be as challenging as the most difficult Hanford waste. The purpose of this study is to quantify how the current five-part simulant compares to all of the Hanford sludge waste, and to suggest alternate simulants that could be tested to reduce the uncertainty in applying the current testing results to potentially more challenging wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Advanced Reusable Technologies Project

Currently, NASA and its industry partners are performing ground testing of hydrogen-fueled rocket based combined-cycle flowpaths. Successful ramjet and scramjet testing at Mach 6 and scramjet testing at Mach 8 have been performed. Cold flow mixing tests have also been successfully performed as have inlet operability tests. Additional testing of RBCC flowpaths at air augmented rocket and rocket only modes is underway.

Turner, James E.↗

Corrosion Control in Carbon Fiber Reinforced Plastic (CFRP) Composite-Aluminum Closure Panel Hem Joints

This project targeted the implementation of CFRP/Al closure panels as a drop-in replacement for all-aluminum closures used in automobile production today. The project focused on the development of corrosion fundamentals involving CFRP materials and the use of those materials in mixed-material joints. Numerous studies were completed to benchmark current materials and test mixed metal joints. Good correlation was found between outdoor exposures and laboratory cyclic corrosion testing. The insights from the corrosion testing fundamentals and benchmarking phases informed the development of low-cure adhesive and electrocoats and conductive primers for the CFRP. Adhesive and electrocoat materials were successfully developed meeting low-cure targets for bake (150C/10min). These materials were scaled-up and used to produce 5 prototype liftgates to further evaluate CFRP/Al joints in a full-scale part. The lower cure materials enabled mitigation of CTE mismatch and reduced the required bake temperature, resulting in reduced part distortion. Corrosion testing of the liftgates revealed unexpected increases in corrosion relative to the standard bake materials. While rigorous evaluation of the parts was not possible due to numerous complexities associated with prototype testing, the results provided significant insights into the material behavior of CFRP/Al joints. Key learnings from the project included a better understanding of the system complexity (interplay of substrate/primer conductivity, production of full-scale prototypes), advances in coating/adhesive design for low-cure applications involving CFRP, and advancement of corrosion test protocols for CFRP.

36 MATERIALS SCIENCE↗

PILOT-SCALE TESTING OF THE SUSPENSION OF MST, CST, AND SIMULATED SLUDGE SLURRIES IN A SLUDGE TANK

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Following strontium, actinide, and cesium removal, the concentrated solids will be transported to a sludge tank (i.e., monosodium titanate (MST)/sludge solids to Tank 42H or Tank 51H and crystalline silicotitanate (CST) to Tank 40H) for eventual transfer to the Defense Waste Processing Facility (DWPF). Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for mixing MST, CST, and simulated sludge. The purpose of this pilot scale testing is to determine the pump requirements for mixing MST and CST with sludge in a sludge tank and to determine whether segregation of particles occurs during settling. Tank 40H and Tank 51H have four Quad Volute pumps; Tank 42H has four standard pumps. The pilot-scale tank is a 1/10.85 linear scaled model of Tank 40H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 40H. The pump locations correspond to the current locations in Tank 40H (Risers B2, H, B6, and G). The pumps are pilot-scale Quad Volute pumps. Additional settling tests were conducted in a 30 foot tall, 4 inch inner diameter clear column to investigate segregation of MST, CST, and simulated sludge particles during settling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heated Bundle Test in AREVA Inc's Fuel Cooling Test Facility

As part the Department of Energy (DOE) initiative for advanced nuclear fuel development, AREVA Inc is performing a series of flow and thermal mixing tests on a simulated, internally heated bundle of wire-wrapped fuel pins of the type commonly used in liquid-metal fast-breeder reactors at its Fuel Cooling Test Facility (FCTF) in Richland, Washington. The FCTF is part of the Product Development Test Facility (PDTF), which is a dedicated facility for advanced thermal-hydraulic testing of nuclear fuel assemblies. Initially developed to perform post Loss Of Coolant Accident (LOCA) testing, i.e., spray and reflood tests, this test facility has been adapted to accommodate the unique requirements of the heated bundle tests described here. The purpose of this test is to investigate and measure thermal distribution and pressure drop behavior for two configurations (non-deformed and deformed duct) of heated 61-pin, hexagonally packed fast reactor test assembly in a fully turbulent regime for generating Computational Fluid Dynamics (CFD) validation grade data. This test is performed in conjunction with high fidelity flow field measurement experiments and high fidelity CFD to provide a comprehensive understanding of the flow inside such a design. The present paper focuses on the heated bundle test performed at AREVA Inc. First, the test loop is described and then an overview of the test activities is presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mixing and transient interface condensation of a liquid hydrogen tank

Experiments were conducted to investigate the effect of axial jet-induced mixing on the pressure reduction of a thermally stratified liquid hydrogen tank. The tank was nearly cylindrical, having a volume of about 0.144 cu m with 0.559 m in diameter and 0.711 m length. A mixer/pump unit, which had a jet nozzle outlet of 0.0221 m in diameter was located 0.178 m from the tank bottom and was installed inside the tank to generate the axial jet mixing and tank fluid circulation. Mixing tests began with the tank pressures at which the thermal stratification results in 4.9-6.2 K liquid subcooling. The mixing time and transient vapor condensation rate at the liquid-vapor interface are determined. Two mixing time correlations, based on the thermal equilibrium and pressure equilibrium, are developed and expressed as functions of system and buoyancy parameters. The limited liquid hydrogen data of the present study shows that the modified steady state condensation rate correlation may be used to predict the transient condensation rate in a mixing process if the instantaneous values of jet sub cooling and turbulence intensity at the interface are employed.

Lin, C. S.↗

INVESTIGATING SUSPENSION OF MST, CST, AND SIMULATED SLUDGE SLURRIES IN A PILOT-SCALE WASTE TANK

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending and resuspending monosodium titanate (MST), crystalline silicotitanate (CST), and simulated sludge. The purpose of this pilot scale testing is for the pumps to resuspend the MST, CST, and simulated sludge particles so that they can be removed from the tank, and to suspend the MST so it can contact strontium and actinides. The pilot-scale tank is a 1/10.85 linear scaled model of Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX program (Risers B5, B3, and B1). Previous testing showed that three Submersible Mixer Pumps (SMPs) will provide sufficient power to initially suspend MST in an SRS waste tank, and to resuspend MST that has settled in a waste tank at nominal 45 C for four weeks. The conclusions from this analysis are: (1) Three SMPs will be able to resuspend more than 99.9% of the MST and CST that has settled for four weeks at nominal 45 C. The testing shows the required pump discharge velocity is 84% of the maximum discharge velocity of the pump. (2) Three SMPs will be able to resuspend more than 99.9% of the MST, CST, and simulated sludge that has settled for four weeks at nominal 45 C. The testing shows the required pump discharge velocity is 82% of the maximum discharge velocity of the pump. (3) A contact time of 6-12 hours is needed for strontium sorption by MST in a jet mixed tank with cooling coils, which is consistent with bench-scale testing and actinide removal process (ARP) operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mixing fraction of inner solar system material in comet 81P/Wild2

The presence of crystalline silicates in the comae of comets, inferred through infrared observations, has been a long-standing puzzle. Crystalline silicates are unexpectedif comets are composed of pristine interstellar material, since interstellar silicates are almost entirely amorphous. Heating to> 1100 K can anneal silicates to crystallinity,but no protoplanetary heating sources have been identified that were sufficiently strong to heat materials in the outer nebula to such high temperatures. This conundrum led to the suggestion that large-scalemixing was important in theprotoplanetary disk. Reports of refractory calcium - aluminum-rich inclusion-like objects and large concentrations of noble gases in Stardust samples underscore the need for such mixing. However, the evidence from the Stardust samples until now has been largely anecdotal, and it has not been possible to place quantitative constraints on the mixing fraction. Here we report synchrotron-based X-ray microprobe measurements of the relative concentrations of the chemical state of iron in material from a known comet, the Jupiter-family comet 81P/Wild2. We find that the comet is rich in iron sulfides. The elemental S/Fe ratio based on the sulfide concentration, S/Fe> 0.31(2 sigma), is higher than in most chondritic meteorites. We also found that Fe-bearing silicates are at least 50percent crystalline. Based on these measurements, we estimate the fraction psi of inner nebular material in 81P/Wild2. With the lower bound on the crystalline Fe-bearing silicate fraction, we find that psi> 0.5. If the observed S depletion in the inner solar system predated or was contemporaneous with large-scale mixing, our lower bound on the S/Fe ratio gives an upper bound on psi of ~;; 0.65. This measurement may be used to test mixing models of the early solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

Scale model performance test investigation of mixed flow exhaust systems for an energy efficient engine /E3/ propulsion system

As part of the NASA Energy Efficient Engine program, scale-model performance tests of a mixed flow exhaust system were conducted. The tests were used to evaluate the performance of exhaust system mixers for high-bypass, mixed-flow turbofan engines. The tests indicated that: (1) mixer penetration has the most significant affect on both mixing effectiveness and mixer pressure loss; (2) mixing/tailpipe length improves mixing effectiveness; (3) gap reduction between the mixer and centerbody increases high mixing effectiveness; (4) mixer cross-sectional shape influences mixing effectiveness; (5) lobe number affects mixing degree; and (6) mixer aerodynamic pressure losses are a function of secondary flows inherent to the lobed mixer concept.

Kuchar, A. P.↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗