Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sonic boom measurement test plan for Space Shuttle STS-2 reentry

Procedures and system specifications associated with the space shuttle STS-2 sonic boom measurement program are described. Specifically included are details such as mobile data acquisition station locations, measurement systems calibration levels, predicted sonic boom overpressure levels, overpressure level assignment for each data acquisition station, data recording times on and off, universal coordinate time, and measurement system descriptions.

Henderson, H. R.↗

2019 Corrective Measures Implementation and Intermim Measures Annual Status Report: Summary of Biosparge System Operation and Maintenance, and Interim Groundwater Monitoring Mobile Launch Platform / Vehicle Assembly Building Area (SWMU 056) Kennedy Space Center, Florida

This report presents a summary of the Corrective Measures Implementation (CMI) and Interim Measure (IM) implementation activities that occurred from May 2019 through December 2019 at the Mobile Launch Platform/Vehicle Assembly Building (MLPV) Area, Solid Waste Management Unit 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida.

MOBILE LAUNCH PLATFORM / VEHICLE ASSEMBLY BUILDING↗

2021 Corrective Measures Implementation and Interim Measures Annual Status Report: Summary of Biosparge System Operation and Maintenance, and Interim Groundwater Monitoring Mobile Launch Platform Rehabilitation Sites / Vehicle Assembly Building Area (SWMU 056) Kennedy Space Center, Florida

This report presents a summary of the Corrective Measures Implementation (CMI) and Interim Measure (IM) implementation activities that occurred from January 2021 through December 2021 at the Mobile Launch Platform Rehabilitation Sites (MLP)/Vehicle Assembly Building (VAB) Area, Solid Waste Management Unit 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida. The following summaries briefly describe areas within SWMU 056 identified by historical site investigation activities where groundwater monitoring and remedial actions have been implemented to date.

Randall K. Sillan↗

Measuring Mobility Potential: A Novel Metric to Quantify Mobility Energy Productivity (MEP) of Transportation Systems

For nearly a century, the automobile has been the primary mode of personal transportation in American life. This remains true today as millions of people rely heavily on cars to connect suburbs with cities or to travel long distances - often out of routine or convenience. However, advances in technology are fueling an era of transportation transformation, with the potential to transform a system that has remained virtually unchanged for decades. The challenges of interconnecting our cities and creating a cross-continental transportation system for military purposes spawned the interstate highway system, generating the age of the automobile. In this century, congestion and mobility challenges of rising urban populations are spawning ever-evolving mobility and communications technologies to connect people to goods, services, and employment within a metropolitan and national context - all of which define a high quality of life. Aspiring smart cities are wrestling with questions such as: How does mobility impact a person's quality of life? Would people make different travel choices if they were presented with better information about their mobility options? Would businesses make different location decisions if they could assess the quality of mobility in that area? The ability to quantify the quality of mobility at a given location is the first step toward answering these questions. In response, an interdisciplinary team at the National Renewable Energy Laboratory (NREL) has developed the Mobility-Energy Productivity (MEP) metric. The MEP metric provides an avenue to not only measure the quality of mobility at a specific location in its current configuration, but also to test how various technological advances (e.g., connected and automated vehicles, plug-in electric vehicles, shared mobility) and infrastructure investments (e.g., building an additional highway lane, constructing a new shopping mall, implementing a transit-oriented development) impact the mobility of that location over time.

30 DIRECT ENERGY CONVERSION↗

Weighted Mobility

Engineering semiconductor devices requires an understanding of charge carrier mobility. Typically, mobilities are estimated using Hall effect and electrical resistivity meausrements, which are are routinely performed at room temperature and below, in materials with mobilities greater than 1 cm 2 V -1 s -1 . With the availability of combined Seebeck coefficient and electrical resistivity measurement systems, it is now easy to measure the weighted mobility (electron mobility weighted by the density of electronic states). A simple method to calculate the weighted mobility from Seebeck coefficient and electrical resistivity measurements is introduced, which gives good results at room temperature and above, and for mobilities as low as 10 -3 cm 2 V -1 s -1 , <!--FIGURE--> μ w = 331 c m 2 V s ( m Ω c m ρ ) ( T 300 K ) - 3 / 2 [ e x p [ | S | k B / e - 2 ] 1 + exp [ - 5 ( | S | k B / e - 1 ) ] + 3 π 2 | S | k B / e 1 + exp [ 5 ( | S | k B / e - 1 ) ] ] In this paper, μ w is the weighted mobility, ρ is the electrical resistivity measured in mΩ cm, T is the absolute temperature in K, S is the Seebeck coefficient, and k B /e = 86.3 µV K -1 . Weighted mobility analysis can elucidate the electronic structure and scattering mechanisms in materials and is particularly helpful in understanding and optimizing thermoelectric systems.

36 MATERIALS SCIENCE↗

Sonic boom measurement test plan for Space Shuttle STS-4 reentry

Formal documentation for measurement procedures and system specifications, and general information relating to the Space Shuttle STS-4 Sonic Boom Measurement Program are supplied. This test plan is designed to provide information, guidance, and assignment of responsibilities for the acquisition of sonic boom and atmospheric measurements, timing correlation, communications and other necessary supporting tasks. Specifically included are details such as mobile data acquisition station locations, measurement systems calibration levels, predicted sonic boom overpressure levels, overpressure level assignment for each data acquisition station, data recording times on and off, universal coordinated time, and measurement system descriptions.

Henderson, H. R.↗

Sonic boom measurement test plan for Space Shuttle STS-1 reentry

Formal documentation for measurement procedures and system specifications, and general information are relating to the Space Shuttle STS-1 Sonic Boom Measurement Program are supplied. This test plan is designed to provide information, guidance, and assignment of responsibilities for the acquisition of sonic boom and atmospheric measurements, timing correlation, communications and other necessary supporting tasks. Specifically included are details such as mobile data acquisition station locations, measurement systems calibration levels, predicted sonic boom overpressure levels, overpressure level assignment for each data acquisition station, data recording times on and off, universal coordinated time, and measurement system descriptions.

Henderson, H. R.↗

Mobility Energy Productivity Evaluation of Prediction-Based Vehicle Powertrain Control Combined with Optimal Traffic Management

Transportation vehicle and network system efficiency can be defined in two ways: 1) reduction of travel times across all the vehicles in the system, and 2) reduction in total energy consumed by all the vehicles in the system. The mechanisms to realize these efficiencies are treated as independent (i.e., vehicle and network domains) and, when combined, they have not been adequately studied to date. This research aims to integrate previously developed and published research on Predictive Optimal Energy Management Strategies (POEMS) and Intelligent Traffic Systems (ITS), to address the need for quantifying improvement in system efficiency resulting from simultaneous vehicle and network optimization. POEMS and ITS are partially independent methods which do not require each other to function but whose individual effectiveness may be affected by the presence of the other. In order to evaluate the system level efficiency improvements, the Mobility Energy Productivity (MEP) metric is used. MEP specifically measures the connectedness of a system while accounting for time and energy externalities of modes that provide mobility in a given location. A SUMO model is developed to reflect real traffic patterns in Fort Collins, Colorado and data is collected by a probe SUMO vehicle which is validated against data collected on a real vehicle driving the same routes through the city. Individual vehicle and system level efficiencies are calculated using SUMO outputs for scenarios which integrate POEMS and ITS independently as well as jointly. Results from application of POEMS and ITS show improvement in energy consumption and travel times respectively when compared to the respective baseline scenarios. Our conclusion is that there are promising synergistic benefits to travel time and energy efficiency when POEMS and ITS are combined.

ADVANCED PROPULSION SYSTEMS↗

A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

Orton, Daniel J.↗

Intercomparison of Ground and Aerial Systems for Urban Advanced Air Mobility Wind Field Campaigns

The need for accurate wind measurement data in urban areas is a rising concern for advanced air mobility such as uncrewed aircraft systems (UAS) and urban air mobility. The lack of quality observations of wind fields and other parameters presents a challenge for operability. Urban areas provide additional difficulty because of the complex terrain and varying building geometry and their associated flow fields. This has led to an extensive knowledge gap when it comes to real-time urban measurements. This paper focuses on comparison of available systems and the types of measurements for urban wind field campaigns. LiDARs and SoDARs are two of many ground instruments capable of gathering the necessary wind field information. UAS is also a viable technique of obtaining aerial wind measurements. Each of these all have specific strengths that make their measurements more suitable than others. Ground based and airborne systems are evaluated and compared to provide a thorough look into which system or instrument might provide the most accurate and definitive results for urban wind field campaigns.

Tyler L Willhite↗

Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

Bivolaru, Daniel↗

Dynamic electrophoretic fingerprinting of the HIV-1 envelope glycoprotein

Background: Interactions between the HIV-1 envelope glycoprotein (Env) and its primary receptor CD4 are influenced by the physiological setting in which these events take place. In this study, we explored the surface chemistry of HIV-1 Env constructs at a range of pH and salinities relevant to mucosal and systemic compartments through electrophoretic mobility (EM) measurements. Sexual transmission events provide a more acidic environment for HIV-1 compared to dissemination and spread of infection occurring in blood or lymph node. We hypothesize functional, trimeric Env behaves differently than monomeric forms. Results: The dynamic electrophoretic fingerprint of trimeric gp140 revealed a change in EM from strongly negative to strongly positive as pH increased from that of the lower female genital tract (pHx) to that of the blood (pHy). Similar findings were observed using a trimeric influenza Haemagglutinin (HA) glycoprotein, indicating that this may be a general attribute of trimeric viral envelope glycoproteins. These findings were supported by computationally modeling the surface charge of various gp120 and HA crystal structures. To identify the behavior of the infectious agent and its target cells, EM measurements were made on purified whole HIV-1 virions and primary T-lymphocytes. Viral particles had a largely negative surface charge, and lacked the regions of positivity near neutral pH that were observed with trimeric Env. T cells changed their surface chemistry as a function of activation state, becoming more negative over a wider range of pH after activation. Soluble recombinant CD4 (sCD4) was found to be positively charged under a wide range of conditions. Binding studies between sCD4 and gp140 show that the affinity of CD4-gp140 interactions depends on pH. Conclusions: Taken together, these findings allow a more complete model of the electrochemical forces involved in HIV-1 Env functionality. These results indicate that the influence of the localized environment on the interactions of HIV with target cells are more pronounced than previously appreciated. There is differential chemistry of trimeric, but not monomeric, Env under conditions which mimic the mucosa compared to those found systemically. This should be taken into consideration during design of immunogens which targets virus at mucosal portals of entry.

59 BASIC BIOLOGICAL SCIENCES↗

Lidar remote sensing of tropospheric pollutants and trace gases - Programs of NASA Langley Research Center

NASA Langley Research Center is engaged in a number of in-house and contracted programs to develop, evaluate, and apply lidar techniques to remote measurements of pollutant gases, trace molecules, and aerosols. The differential absorption lidar (DIAL) research programs include the development and evaluation of a UV DIAL system for remote measurements of SO2 and O3 concentrations and aerosol dispersion in urban and power-plant stack plumes, a near-IR DIAL system for vertical measurements of water vapor concentrations, and a high-power tunable IR DIAL system which will measure the concentration of gas species that have absorption features in the 1.4- to 4.4-micron wavelength range. The lidar programs which deal with aerosol measurements include the evaluation of a mobile ruby lidar system for use in plume dispersion model verification and the development of a high-spectral-resolution lidar system for measurement of aerosol extinction and backscattering coefficients. System characteristics and measurement sensitivities are discussed, and comparisons are made between simulations and experimental results.

Browell, E. V.↗

Imaging laser analysis of building materials - practical examples

The Laser induced Breakdown Spectroscopy (LIBS) is supplement and extension of standard chemical methods and SEM- or Micro-RFA-applications for the evaluation of building materials. As a laboratory method LIBS is used to gain color coded images representing composition, distribution of characteristic ions and/or ingress characteristic of damaging substances. To create a depth profile of element concentration a core has to be taken and split along the core axis. LIBS was proven to be able to detect all important elements in concrete, e. g. Chlorine, Sodium or Sulfur, which are responsible for certain degradation mechanisms and also light elements like lithium or hydrogen. Practical examples are given and a mobile system for on-site measurements is presented.

36 MATERIALS SCIENCE↗

New signature method for identifying organic material in atmosphere and water samples

The levels of plastic contamination in the earth’s oceans have steadily increased over the past century, creating a threat to marine life and increasing climate change. Several methods have been developed over the past decade to try to determine the amount and accumulation rate of plastic impurities in the ecosystem. These methods have proven promising but suffer from long measurement times, bulky non-mobile systems, and sample degradation. We propose a smaller, faster system that employs an electron beam to examine seawater samples for polyethylene contamination levels. This process generates a full electron and photon energy spectrum analyses based on the subatomic particles generated from electron interactions. Our simulations have already been developed based on the known molecular composition of seawater and polyethylene, showing the possibility of discerning molecular plastics from microorganisms. With a system the size of a suitcase, this system would be easily deployable to remote locations around the world or installed as a monitoring system for manufacturing facilities. This concept could lead to a new methodology for the science of signatures and be applied to other biological hazard investigations, such as general virus detection.

43 PARTICLE ACCELERATORS↗

The 8-18 GHz radar spectrometer

The design, construction, testing, and accuracy of an 8-18 GHz radar spectrometer, an FM-CW system which employs a dual antenna system, is described. The antennas, transmitter, and a portion of the receiver are mounted at the top of a 26 meter hydraulic boom which is in turn mounted on a truck for system mobility. HH and VV polarized measurements are possible at incidence angles ranging from 0 deg. to 80 deg. Calibration is accomplished by referencing the measurements against a Luneberg lens of known radar cross section.

Bush, T. F.↗

Metabolic Assessment of Suited Mobility Using Functional Tasks

Existing methods for evaluating extravehicular activity (EVA) suit mobility have typically focused on isolated joint range of motion or torque, but these techniques have little to do with how well a crewmember functionally performs in an EVA suit. To evaluate suited mobility at the system level through measuring metabolic cost (MC) of functional tasks.

Norcross, J. R.↗