Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modular Batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A regenerative fuel cell system for modular space station integrated electrical power.

A regenerative fuel cell system (RFCS) for energy storage aboard the Modular Space Station (MSS) was selected over the battery technique because of lower cost, lower launch weight, lower required solar array area, and its ability to be integrated into the station's reaction control and environmental control and life support subsystems in addition to the electrical power subsystem. The total MSS energy storage requirement was met by dividing it into four equal modular RFCSs, each made up of a fuel cell subsystem, a water electrolysis subsystem, a gas accumulator subassembly, and a water tank subassembly. The weight of each of the four RFCSs varied from 4000 to 7000 lb with the latter being a more maintainable design. The specific energy ranged between 5.6 to 9.4 watt-hr/lb.

Wynveen, R. A.↗

Halau Uma: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Results indicate that a hybrid PV and battery system, supplemented by small wind turbines, offers a cost-effective, resilient solution supporting energy independence and disaster preparedness.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Kauhale 'O Kipapa: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Findings show hybrid PV and battery systems, supplemented by small wind turbines, offer cost-effective, resilient solutions. This work supports enhanced energy independence and disaster preparedness for the community.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Design of a Multi-Chemistry Battery Pack System for Behind-the-Meter Storage Applications

Battery management systems (BMS) are essential for a battery pack's safe operation and longevity. This paper presents an active balancing method-based BMS for different cell chemistry structures to be used in behind-the-meter storage (BTMS) applications. The proposed system utilizes modular isolated dual active bridge (DAB) DC/DC converters to actively balance the battery pack through a low voltage (LV) bus. A supervisory controller monitors all the cell voltage, current, and state of charge (SOC) values. Based on the estimation of the SOCs, reference currents for the DAB converters are generated by the supervisory controller. Detailed modeling and the control approach of the modular DAB converters are presented in the paper. Moreover, the control strategy of the supervisory control is also analyzed. The proposed method and structure can be extended to any combination of the number of cells to design the battery pack. Simulation results are provided for a system consisting of three cells in parallel to form a cell block and three cell blocks in series to form the battery module. Experimental results are provided for three modular DAB converters operating with a LiFeMnPO4 prismatic cell with 3.2V, 20Ah rated values.

battery management systems↗

A modular electric power system test bed for small spacecraft

In the new climate of smaller, faster, and cheaper space science satellites, a new power system topology has been developed at the NASA Lewis Research Center. This new topology is based on a series connected boost converter (SCBC) and can greatly affect the size, weight, fault tolerance, and cost of any small spacecraft using photovoltaic solar arrays. The paper presents electric power system design factors and requirements as background information. The series connected boost converter topology is discussed and several advantages over existing technologies are illustrated. Besides being small, lightweight, and efficient, this topology has the added benefit of inherent fault tolerance. A positive ground power system test bed has been developed for the TROPIX spacecraft program. Performance of the SCBC in the test bed is described in detail. SCBC efficiencies of 95 percent to 98 percent have been measured. Finally, a modular, photovoltaic regulator 'kit' concept is presented. Two SCBC's are used to regulate solar array charging of batteries and to provide 'utilitytype' power to the user loads. The kit's modularity will allow a spacecraft electric power system to be built from off-the-shelf hardware; resulting in smaller, faster, and cheaper spacecraft.

Button, Robert M.↗

Integration of Wireless Sensor Networks and Battery-free RFID for Advanced Reactors

To address an important need for Nuclear Power Plants (NPPs) to significantly reduce the amount of the required cables for sensor data communications, this Phase I SBIR effort successfully developed and demonstrated a novel low-cost proof-of-concept prototype of a secure wireless sensor network backbone communications system. This system combines commercially available low power, low cost XBEE wireless communications network and passive (battery-free) Radio Frequency Identification (RFID) systems to report individual sensor data and their location through the containment wall for rapid response to anomalies in nuclear facilities. This WIreless Sensing and Locating (WISLO) system network architecture allows non-intrusive wireless collection of sensor data with the sensor’s accurate location information from inside of the instrumentation or containment area with minimal need for power sources. The multi-node sensor data in the containment area is wirelessly transmitted to outside through the metal reinforced concrete walls without the need for any batteries. The WISLO system could be readily used in current reactor fleet and future advanced reactors, as well as in small modular reactors (SMR). The WISLO system is the first dual frequency battery-free trough the wall communications backbone system developed specifically for use in nuclear power plants. It not only can modernize the sensor monitoring practices in the existing reactor fleet, but also offers a secure, low-cost solution to advanced reactors and SMRs by removing cables and issues related to them such as cable integrity, reporting delays, and installation and maintenance costs. The intent is to improve process safety, reliability, efficiency, and cost effectiveness to the monitoring and maintenance process in current and future plants. As we address the next productization and manufacturing capabilities in the next phase, this system will serve the needs of many commercial and government applications in remote monitoring of sensor data that demand battery-free transmission of sensor data such as Internet-of-Things (IOT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guidelines for the Procurement of Aerospace Nickel Cadmium Cells

NASA has been using a Modular Power System containing "standard" nickel cadmium (NiCd) batteries, composed of "standard" NiCd cells. For many years the only manufacturer of the NASA "standard" NiCd cells was General Electric Co. (subsequently Gates Aerospace and now SAFT). This standard cell was successfully used in numerous missions. However, uncontrolled technical changes, and changes in industrial restructuring require a new approach. General Electric (now SAFT Aerospace Batteries) had management changes, new manufacturers entered the market (Eagle-Picher Industries, ACME Electric Corporation, Aerospace Division, Sanyo Electric Co.) and battery technology advanced. New NASA procurements for aerospace NiCd cells will have specifications unique to the spacecraft and mission requirements. This document provides the user/customer guidelines for the new approach to procuring of and specifying performance requirements for highly reliable NiCd cells and batteries. It includes details of key parameters and their importance. The appendices contain a checklist, detailed calculations, and backup information.

Thierfelder, Helmut↗

Lunar Module ECS (Environmental Control System) - Design Considerations and Failure Modes

Design considerations and failure modes for the Lunar Module (LM) Environmental Control System (ECS) are described. An overview of the the oxygen supply and cabin pressurization, atmosphere revitalization, water management and heat transport systems are provided. Design considerations including reliability, flight instrumentation, modularization and the change to the use of batteries instead of fuel cells are discussed. A summary is provided for the LM ECS general testing regime.

Interbartolo, Michael↗

Beyond conventional batteries: a review on semi-solid and redox targeting flow batteries-LiFePO{sub 4} as a case study.

Clean and sustainable energy is becoming increasingly crucial to tackle the current energy crisis. However, the intermittent nature of renewable energy sources presents a challenge for their effective implementation. Redox flow batteries (RFBs) have emerged as a promising solution to this problem, as they can help enhance the stability of grid networks and promote the use of renewable energy sources. RFBs are highly modular and scalable systems that can be customized to meet the power and energy requirements of different renewable energy plants. Moreover, they offer several advantages over conventional battery technologies, including cost and safety concerns. However, conventional RFBs have limited energy densities due to the low solubility of their active species in electrolyte. To overcome this limitation, semi-solid (SSRFBs) and redox targeting (RTFBs) flow batteries have been proposed. These systems feature high concentrations of active species and impressive energy densities, making them highly attractive for renewable energy applications. LiFePO4 (LFP) is a highly promising active material for semi-solid and targeting flow batteries. One of the key advantages of LFP is its low raw materials cost, as it is composed of Earth-abundant elements such as iron and phosphorus. This makes it an attractive option for large-scale battery production. The recent developments in SSRFBs and RTFBs using LFP as catholyte hold great promise for the future of sustainable energy storage. The combination of LFP's low cost, safety, durability, and high energy density with the modularity and scalability of flow battery systems make for a compelling solution to the challenges of intermittent renewable energy sources. Ongoing research and development in this area will likely yield even further improvements in the performance and efficiency of LFP-based flow batteries, opening exciting new possibilities for sustainable energy storage.

El Halya, Nabil↗

Development of High Energy Density Diaminocyclopropenium-Phenothiazine Hybrid Catholytes for Non-Aqueous Redox Flow Batteries

Our work describes the design of diaminocyclopropenium-phenothiazine hybrid catholytes for non-aqueous redox flow batteries. The molecules are synthesized in a rapid and modular fashion by appending a diaminocyclopropenium (DAC) substituent to the nitrogen of the phenothiazine. Combining a versatile C-N coupling protocol (which provides access to diverse derivatives) with computation and structure-property analysis enabled the identification of a catholyte that displays stable two-electron cycling at potentials of 0.64 and 1.00 V vs. Fc/Fc + as well as high solubility in all oxidation states (≥0.45 M in TBAPF 6 /MeCN). This catholyte was deployed in a high energy density two-electron RFB, exhibiting >90 % capacity retention over 266 hours of flow cell cycling at >0.5 M electron concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High Energy Density Diaminocyclopropenium‐Phenothiazine Hybrid Catholytes for Non‐Aqueous Redox Flow Batteries

Abstract This report describes the design of diaminocyclopropenium‐phenothiazine hybrid catholytes for non‐aqueous redox flow batteries. The molecules are synthesized in a rapid and modular fashion by appending a diaminocyclopropenium (DAC) substituent to the nitrogen of the phenothiazine. Combining a versatile C‐N coupling protocol (which provides access to diverse derivatives) with computation and structure‐property analysis enabled the identification of a catholyte that displays stable two‐electron cycling at potentials of 0.64 and 1.00 V vs. Fc/Fc + as well as high solubility in all oxidation states (≥0.45 M in TBAPF 6 /MeCN). This catholyte was deployed in a high energy density two‐electron RFB, exhibiting >90 % capacity retention over 266 hours of flow cell cycling at >0.5 M electron concentration.

Yan, Yichao↗

Representing DC-Coupled PV+Battery Hybrids in a Capacity Expansion Model

Recent technology cost and performance improvements and the federal investment tax credit (ITC) have driven growing interest in coupling solar photovoltaic (PV) and battery systems. Combining these technologies into co-located or hybridized PV+battery systems has the potential to lower costs and increase energy output relative to multiple independent systems. In this work, we provide an overview of PV+battery systems and demonstrate methods for incorporating them into NREL’s Regional Energy Deployment System (ReEDS) capacity expansion model. Although the methods are applied to a specific model, we anticipate that the approaches used here can be useful for informing PV+battery method development for other capacity expansion models. The implemented method relies heavily on the native representations of PV and battery technologies; therefore, the focus of this work is on capturing and parameterizing the interactions between them for a configuration in which the PV and battery technologies share a single bi-directional inverter. This work also demonstrates the impacts of including PV+battery systems in the ReEDS optimization for the conterminous United States through 2050. In particular, we perform parametric sensitivities for input assumptions that are uncertain and expected to influence PV+battery deployment levels, including (a) the cost of PV+battery systems relative to independent PV and battery systems, (b) the battery component’s qualification for the ITC, and (c) future cost trajectories for PV and battery systems. We find that PV+battery deployment could occur throughout the conterminous United States if there are cost savings associated with DC coupling PV and battery technologies. If even modest (5%) cost savings can be achieved (through a shared inverter and balance-of-system costs), then approximately one-third of utility-scale PV deployment through 2050 adopts the DC-coupled hybrid configuration, resulting in total PV+battery deployment that exceeds the magnitude of PV+battery projects in U.S. interconnection queues in 2020. If greater cost savings can be achieved through DC coupling (e.g., due to a growing amount of shared balance-of-system costs, reduced financial risk, or modularity) or more rapid cost and performance improvements are realized for PV and battery technologies, then total PV+battery deployment and the share of PV and battery deployment that adopts the hybrid configuration grows (to >50%). In all cases, growing PV+battery deployment primarily displaces independent PV and battery technologies, indicating the strong competition between the hybrid and independent configurations comprising technologies with similar performance characteristics.

14 SOLAR ENERGY↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AI-assisted rapid crystal structure generation towards a target local environment

In material design, traditional crystal structure prediction approaches are expensive as they require extensive structural sampling through expensive energy minimization methods. Emerging artificial intelligence (AI) generative models have shown great promise in rapidly generating realistic crystals, but they typically handle only a few tens of atoms per unit cell. To overcome this limitation, we introduce a symmetry-informed approach, the Local Environment Geometry-Oriented Crystal Generator (LEGO-xtal). Our method generates initial structures using AI models trained on an augmented dataset, and then optimizes them using structure descriptors rather than energy-based optimization. We demonstrate its effectiveness by expanding from 25 known low-energy sp2 carbon allotropes to over 1700, all within 0.5 eV/atom of the ground-state energy of graphite. This framework offers a generalizable strategy for the targeted design of materials with modular building blocks, such as metal-organic frameworks and battery materials.

Ridwan, Osman Goni [University of North Carolina a↗

Ultralight reactive metal foams produced as structural shapes in space: System design

This autonomous experiment for foaming metals in space involved: (1) payload support structure; (2) furnace and foaming apparatus; (3) electronic controls; (4) battery power; and (5) metallurgy. Emphasis was laid on a modular design which was easily modifiable and which offered maximum durability, safety, and failure tolerance.

Cocks, F. H.↗

Wireless Instrumentation System and Power Management Scheme Therefore

A wireless instrumentation system enables a plurality of low power wireless transceivers to transmit measurement data from a plurality of remote station sensors to a central data station accurately and reliably. The system employs a relay based communications scheme where remote stations that cannot communicate directly with the central station due to interference, poor signal strength, etc., are instructed to communicate with other of the remote stations that act as relays to the central station. A unique power management scheme is also employed to minimize power usage at each remote station and thereby maximize battery life. Each of the remote stations prefembly employs a modular design to facilitate easy reconfiguration of the stations as required.

Perotti, Jose↗

LESSH Lunar Experiment Support System and Handling Battery Charger Module

Beginning with Artemis III, NASA plans to deploy science instruments on the moon near a South Pole landing site. To extend lunar science operations, an EVA compatible LESSH Battery Charger Module (BCM) enables recharging and hard-line data transfer at the modular GFP Interface Bank on the Human Landing System (HLS) or other Artemis vehicles. The LESSH BCM provides an ergonomic interface for astronauts to connect instruments to HLS power and data interfaces. The BCM provides battery charge monitoring and enables data transfer via a flexible harness. LESSH-Placed is an instrument package that can be deployed by astronauts and re-charged via an Artemis vehicle, enabling extended science operations.

LESSH↗

Techno-Economic Analysis of a Nuclear Reactor System coupled with a Liquid Metal Battery

There is a need for nuclear reactor systems to become more dynamic as defossilization and renewable energy sources continue to reshape the energy grid. One option to meet these changing demands is to pair the reactor with an energy storage system. This work details a technoeconomic analysis and sensitivity analysis of a high temperature gas cooled microreactor, supercritical carbon dioxide power cycle, and liquid metal battery. Dynamic modeling has shown that these three systems compliment each other to provide load following and black-start capabilities to the grid. Current cost estimates for installing the systems yield a competitive levelized cost of electricity and levelized cost of storage, indicating that such a combined system may be economically viable as technological advances lead to them being technically feasible.

25 ENERGY STORAGE↗