Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

FREYA-a new Monte Carlo code for improved modeling of fission chains

A new simulation capability for modeling of individual fission events and chains and the transport of fission products in materials is presented. FREYA ( Fission Yield Event Yield Algorithm ) is a Monte Carlo code for generating fission events providing correlated kinematic information for prompt neutrons, gammas, and fragments. As a standalone code, FREYA calculates quantities such as multiplicity-energy, angular, and gamma-neutron energy sharing correlations. To study materials with multiplication, shielding effects, and detectors, we have integrated FREYA into the general purpose Monte Carlo code MCNP. This new tool will allow more accurate modeling of detector responses including correlations and the development of SNM detectors with increased sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary estimates of nucleon fluxes in a water target exposed to solar-flare protons: BRYNTRN versus Monte Carlo code

A baryon transport code (BRYNTRN) has previously been verified using available Monte Carlo results for a solar-flare spectrum as the reference. Excellent results were obtained, but the comparisons were limited to the available data on dose and dose equivalent for moderate penetration studies that involve minor contributions from secondary neutrons. To further verify the code, the secondary energy spectra of protons and neutrons are calculated using BRYNTRN and LAHET (Los Alamos High-Energy Transport code, which is a Monte Carlo code). These calculations are compared for three locations within a water slab exposed to the February 1956 solar-proton spectrum. Reasonable agreement was obtained when various considerations related to the calculational techniques and their limitations were taken into account. Although the Monte Carlo results are preliminary, it appears that the neutron albedo, which is not currently treated in BRYNTRN, might be a cause for the large discrepancy seen at small penetration depths. It also appears that the nonelastic neutron production cross sections in BRYNTRN may underestimate the number of neutrons produced in proton collisions with energies below 200 MeV. The notion that the poor energy resolution in BRYNTRN may cause a large truncation error in neutron elastic scattering requires further study.

Shinn, Judy L.↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

SU-E-T-590: Optimizing Magnetic Field Strengths with Matlab for An Ion-Optic System in Particle Therapy Consisting of Two Quadrupole Magnets for Subsequent Simulations with the Monte-Carlo Code FLUKA

Purpose: Aim of this study was to optimize the magnetic field strengths of two quadrupole magnets in a particle therapy facility in order to obtain a beam quality suitable for spot beam scanning. Methods: The particle transport through an ion-optic system of a particle therapy facility consisting of the beam tube, two quadrupole magnets and a beam monitor system was calculated with the help of Matlab by using matrices that solve the equation of motion of a charged particle in a magnetic field and field-free region, respectively. The magnetic field strengths were optimized in order to obtain a circular and thin beam spot at the iso-center of the therapy facility. These optimized field strengths were subsequently transferred to the Monte-Carlo code FLUKA and the transport of 80 MeV/u C12-ions through this ion-optic system was calculated by using a user-routine to implement magnetic fields. The fluence along the beam-axis and at the iso-center was evaluated. Results: The magnetic field strengths could be optimized by using Matlab and transferred to the Monte-Carlo code FLUKA. The implementation via a user-routine was successful. Analyzing the fluence-pattern along the beam-axis the characteristic focusing and de-focusing effects of the quadrupole magnets could be reproduced. Furthermore the beam spot at the iso-center was circular and significantly thinner compared to an unfocused beam. Conclusion: In this study a Matlab tool was developed to optimize magnetic field strengths for an ion-optic system consisting of two quadrupole magnets as part of a particle therapy facility. These magnetic field strengths could subsequently be transferred to and implemented in the Monte-Carlo code FLUKA to simulate the particle transport through this optimized ion-optic system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress and status of the OpenMC Monte Carlo code

The present work describes the latest advances and progress in the development of the OpenMC Monte Carlo code, an open-source code originating from the Massachusetts Institute of Technology. First, an overview of the development workflow of OpenMC is given. Various enhancements to the code such as real-time XML input validation, state points, plotting, OpenMP threading, and coarse mesh finite difference acceleration are described. (authors)

97 MATHEMATICS AND COMPUTING↗

Application of Monte Carlo code SHIFT for MSBR dose rate calculations

This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Burnup calculation methodology in the serpent 2 Monte Carlo code

This paper presents two topics related to the burnup calculation capabilities in the Serpent 2 Monte Carlo code: advanced time-integration methods and improved memory management, accomplished by the use of different optimization modes. The development of the introduced methods is an important part of re-writing the Serpent source code, carried out for the purpose of extending the burnup calculation capabilities from 2D assembly-level calculations to large 3D reactor-scale problems. The progress is demonstrated by repeating a PWR test case, originally carried out in 2009 for the validation of the newly-implemented burnup calculation routines in Serpent 1. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A particle-in-cell Monte Carlo code for electron beam ion source simulation

FAR-TECH, Inc., has developed a particle-in-cell Monte Carlo code (EBIS-PIC) to model ion motions in an electron beam ion source (EBIS). First, a steady state electron beam is simulated by the PBGUNS code (see http://far-tech.com/pbguns/index.html). Then, the injected primary ions and the ions from the background neutral gas are tracked in the trapping region using Monte Carlo method. Atomic collisions and Coulomb collisions are included in the EBIS-PIC model. The space charge potential is updated by solving the Poisson equation each time step. The preliminary simulation results are presented and compared with BNL electron beam test stand (EBTS) fast trapping experiments.

43 PARTICLE ACCELERATORS↗

Development of a dynamic simulation mode in Serpent 2 Monte Carlo code

This paper presents a dynamic neutron transport mode, currently being implemented in the Serpent 2 Monte Carlo code for the purpose of simulating short reactivity transients with temperature feedback. The transport routine is introduced and validated by comparison to MCNP5 calculations. The method is also tested in combination with an internal temperature feedback module, which forms the inner part of a multi-physics coupling scheme in Serpent 2. The demo case for the coupled calculation is a reactivity-initiated accident (RIA) in PWR fuel. (authors)

97 MATHEMATICS AND COMPUTING↗

Multi-node and Multi-core Performance Studies of a Monte Carlo code RMC

Over the past 15 years the architecture of high-performance computing systems has become increasingly heterogeneous with individual computing cores being subdivided into nodes and even auxiliary co-processing units such as graphics processing units or the Intel many integrated core co-processors. In fact, future computer platforms is moving toward a larger number of nodes and cores with lower memory available per node. Today, several production Monte Carlo codes use some types of hybrid parallelism strategy that makes use of shared-memory parallelism within a computing node and message-passing parallelism between nodes, which enables the codes to utilize available computing resources as much as possible, both among and within computing nodes on a cluster. The so-called hybrid parallelization is also possible with Reactor Monte Carlo Code RMC by activating both MPI and OpenMP parallel algorithms together. On HPC' which typically consists of several or several-ten thousand nodes equipping 16-32 computing intra-cores per node, simulation of RMC can be carried out in the hybrid parallelization with the MPI inter-node parallelization and the OpenMP intra-node parallelization. RMC has adopted a hybrid message-passing and shared-memory approach to parallelism, which enables the code to utilize available computing resources, both among and within computing nodes on a cluster. Shared-memory parallelism is especially valuable for large-model simulations because it enables multiple compute cores within a node to share common model information such as the geometry description, material, cross section and tally data, thus reducing the memory usage per processor. The calculation on the Tianhe-2 supercomputer took 6144 cores, resulting in a rate of 173,314,000 neutrons/minute for BEAVRS benchmark. While pin-wise full core H-M benchmark burnup calculations with millions of depletion regions was selected using MPI/OpenMP parallelism, the speed of 6,144 cores reach 1,843,200 burnable regions per minute. Keeping up with the continuing trend for increases in the number of computing resources within modern HPC systems is a significant challenge for teams that develop and maintain high-performance MC radiation transport solvers. order to address this challenge, RMC has adopted a hybrid message-passing and shared-memory approach to parallelism, which enables the code to utilize available computing resources, both among and within computing nodes on a cluster. Shared-memory parallelism is especially valuable for large-model simulations because it enables multiple compute cores within a node to share common model information such as the geometry description, material and composition definitions, and cross section data, thus reducing the memory usage per processor. The parallel performance has been studied by using two complex and representative benchmarks, H-M and BEAVRS benchmark. All simulations were run on Intel Xeon E5-2692 12 core, 2.2 GHz processors at MilkyWay-2 Super Computer with up to 12,288 available computing cores. While employing MPI parallelism, excellent parallel efficiency is achieved even above 12,000 processors and RMC reaches the parallel efficiency of 96% on 12,288 cores for the pin-by-pin computation of the BEAVRS benchmark. While BEAVRS criticality benchmark was selected using MPI/OpenMP parallelism, the speed of 6,144 cores reach 173,314,000 particles per minute. While pin-wise full core H-M benchmark burnup calculations with millions of depletion regions was selected using MPI/OpenMP parallelism, the speed of 6,144 cores reach 1,843,200 burnable regions per minute. Results from these studies demonstrate that RMC, using the hybrid parallel model described in this paper, is able to handle pin-wise full core burnup calculations with millions of depletion regions and scales well through thousands of processors. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-121: Analyzing the Broadening Effect On the Bragg Peak Due to Heterogeneous Geometries and Implementing User-Routines in the Monte-Carlo Code FLUKA in Order to Reduce Computation Time

Purpose: Aim of this study was to analyze the modulating, broadening effect on the Bragg Peak due to heterogeneous geometries like multi-wire chambers in the beam path of a particle therapy beam line. The effect was described by a mathematical model which was implemented in the Monte-Carlo code FLUKA via user-routines, in order to reduce the computation time for the simulations. Methods: The depth dose curve of 80 MeV/u C12-ions in a water phantom was calculated using the Monte-Carlo code FLUKA (reference curve). The modulating effect on this dose distribution behind eleven mesh-like foils (periodicity ∼80 microns) occurring in a typical set of multi-wire and dose chambers was mathematically described by optimizing a normal distribution so that the reverence curve convoluted with this distribution equals the modulated dose curve. This distribution describes a displacement in water and was transferred in a probability distribution of the thickness of the eleven foils using the water equivalent thickness of the foil’s material. From this distribution the distribution of the thickness of one foil was determined inversely. In FLUKA the heterogeneous foils were replaced by homogeneous foils and a user-routine was programmed that varies the thickness of the homogeneous foils for each simulated particle using this distribution. Results: Using the mathematical model and user-routine in FLUKA the broadening effect could be reproduced exactly when replacing the heterogeneous foils by homogeneous ones. The computation time was reduced by 90 percent. Conclusion: In this study the broadening effect on the Bragg Peak due to heterogeneous structures was analyzed, described by a mathematical model and implemented in FLUKA via user-routines. Applying these routines the computing time was reduced by 90 percent. The developed tool can be used for any heterogeneous structure in the dimensions of microns to millimeters, in principle even for organic materials like lung tissue.

60 APPLIED LIFE SCIENCES↗

Implementation of hybrid variance reduction methods in a multi group Monte Carlo code for deep shielding problems

In this paper, the work that has been done to implement variance reduction techniques in a three dimensional, multi group Monte Carlo code - Tortilla, that works within the frame work of the commercial deterministic code - Attila, is presented. This project is aimed to develop an integrated Hybrid code that seamlessly takes advantage of the deterministic and Monte Carlo methods for deep shielding radiation detection problems. Tortilla takes advantage of Attila's features for generating the geometric mesh, cross section library and source definitions. Tortilla can also read importance functions (like adjoint scalar flux) generated from deterministic calculations performed in Attila and use them to employ variance reduction schemes in the Monte Carlo simulation. The variance reduction techniques that are implemented in Tortilla are based on the CADIS (Consistent Adjoint Driven Importance Sampling) method and the LIFT (Local Importance Function Transform) method. These methods make use of the results from an adjoint deterministic calculation to bias the particle transport using techniques like source biasing, survival biasing, transport biasing and weight windows. The results obtained so far and the challenges faced in implementing the variance reduction techniques are reported here. (authors)

97 MATHEMATICS AND COMPUTING↗

Development of continuous-energy eigenvalue sensitivity coefficient calculation methods in the shift Monte Carlo Code

Three methods for calculating continuous-energy eigenvalue sensitivity coefficients were developed and implemented into the Shift Monte Carlo code within the SCALE code package. The methods were used for two small-scale test problems and were evaluated in terms of speed, accuracy, efficiency, and memory requirements. A promising new method for calculating eigenvalue sensitivity coefficients, known as the CLUTCH method, was developed and produced accurate sensitivity coefficients with figures of merit that were several orders of magnitude larger than those from existing methods. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Continuous-Energy Eigenvalue Sensitivity Coefficient Calculation Methods in the Shift Monte Carlo Code

Three methods for calculating continuous-energy eigenvalue sensitivity coefficients were developed and implemented into the SHIFT Monte Carlo code within the Scale code package. The methods were used for several simple test problems and were evaluated in terms of speed, accuracy, efficiency, and memory requirements. A promising new method for calculating eigenvalue sensitivity coefficients, known as the CLUTCH method, was developed and produced accurate sensitivity coefficients with figures of merit that were several orders of magnitude larger than those from existing methods.

42 ENGINEERING↗

SU-E-T-180: Fano Cavity Test of Proton Transport in Monte Carlo Codes Running On GPU and Xeon Phi

Purpose: In proton dose calculation, clinically compatible speeds are now achieved with Monte Carlo codes (MC) that combine 1) adequate simplifications in the physics of transport and 2) the use of hardware architectures enabling massive parallel computing (like GPUs). However, the uncertainties related to the transport algorithms used in these codes must be kept minimal. Such algorithms can be checked with the so-called “Fano cavity test”. We implemented the test in two codes that run on specific hardware: gPMC on an nVidia GPU and MCsquare on an Intel Xeon Phi (60 cores). Methods: gPMC and MCsquare are designed for transporting protons in CT geometries. Both codes use the method of fictitious interaction to sample the step-length for each transport step. The considered geometry is a water cavity (2×2×0.2 cm{sup 3}, 0.001 g/cm{sup 3}) in a 10×10×50 cm{sup 3} water phantom (1 g/cm{sup 3}). CPE in the cavity is established by generating protons over the phantom volume with a uniform momentum (energy E) and a uniform intensity per unit mass I. Assuming no nuclear reactions and no generation of other secondaries, the computed cavity dose should equal IE, according to Fano's theorem. Both codes were tested for initial proton energies of 50, 100, and 200 MeV. Results: For all energies, gPMC and MCsquare are within 0.3 and 0.2 % of the theoretical value IE, respectively (0.1% standard deviation). Single-precision computations (instead of double) increased the error by about 0.1% in MCsquare. Conclusion: Despite the simplifications in the physics of transport, both gPMC and MCsquare successfully pass the Fano test. This ensures optimal accuracy of the codes for clinical applications within the uncertainties on the underlying physical models. It also opens the path to other applications of these codes, like the simulation of ion chamber response.

60 APPLIED LIFE SCIENCES↗

A collision history-based approach to Sensitivity/Perturbation calculations in the continuous energy Monte Carlo code SERPENT

In this work, the implementation of a collision history-based approach to sensitivity/perturbation calculations in the Monte Carlo code SERPENT is discussed. The proposed methods allow the calculation of the eects of nuclear data perturbation on several response functions: the eective multiplication factor, reaction rate ratios and bilinear ratios (e.g., eective kinetics parameters). SERPENT results are compared to ERANOS and TSUNAMI Generalized Perturbation Theory calculations for two fast metallic systems and for a PWR pin-cell benchmark. New methods for the calculation of sensitivities to angular scattering distributions are also presented, which adopts fully continuous (in energy and angle) Monte Carlo estimators.

97 MATHEMATICS AND COMPUTING↗

Domain decomposition in the GPU-accelerated Shift Monte Carlo code

The GPU solver within the Shift continuous-energy Monte Carlo neutron transport code has been extended to provide domain decomposition in addition to domain replication to enable the solution of problems with memory requirements exceeding the capacity of a single GPU. The strategy follows the Multiple Set, Overlapping Domain (MSOD) approach that is used in Shift’s CPU solver and integrates into the event-based algorithm used for Shift’s GPU solver. Furthermore, the ability to assign processors to spatial domains non-uniformly has been maintained. In this work, two different approaches for communicating particle data between domains are considered, and multiple criteria for load balancing problems have been investigated. Numerical results are presented for both fresh and depleted small modular nuclear reactor (SMR) cores. A parallel efficiency of approximately 80% was achieved with up to 16 spatial domains measured relative to full domain replication. A scaling study on the Summit supercomputer demonstrates a weak scaling parallel efficiency of over 90% on over 24000 GPUs.

97 MATHEMATICS AND COMPUTING↗

Development of GPU-based Monte Carlo code for fast CT imaging dose calculation on CUDA Fermi architecture

This paper describes the development of a Graphics Processing Unit (GPU) accelerated Monte Carlo photon transport code, ARCHER{sub GPU}, to perform CT imaging dose calculations with good accuracy and performance. The code simulates interactions of photons with heterogeneous materials. It contains a detailed CT scanner model and a family of patient phantoms. Several techniques are used to optimize the code for the GPU architecture. In the accuracy and performance test, a 142 kg adult male phantom was selected, and the CT scan protocol involved a whole-body axial scan, 20-mm x-ray beam collimation, 120 kVp and a pitch of 1. A total of 9 x 108 photons were simulated and the absorbed doses to 28 radiosensitive organs/tissues were calculated. The average percentage difference of the results obtained by the general-purpose production code MCNPX and ARCHER{sub GPU} was found to be less than 0.38%, indicating an excellent agreement. The total computation time was found to be 8,689, 139 and 56 minutes for MCNPX, ARCHER{sub CPU} (6-core) and ARCHER{sub GPU}, respectively, indicating a decent speedup. Under a recent grant funding from the NIH, the project aims at developing a Monte Carlo code with the capability of sub-minute CT organ dose calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗