Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Bayesian Monte Carlo Method for Nuclear Data Evaluation

A Bayesian Monte Carlo method is outlined which allows a systematic evaluation of nuclear reactions using TALYS. The result will be either an EXFOR-weighted covariance matrix or a collection of random files, each accompanied by an experiment based weight.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prediction of rocket plume radiative heating using backward Monte-Carlo method

A backward Monte-Carlo plume radiation code has been developed to predict rocket plume radiative heating to the rocket base region. This paper provides a description of this code and provides sample results. The code was used to predict radiative heating to various locations during test firings of 48-inch solid rocket motors at NASA Marshall Space Flight Center. Comparisons with test measurements are provided. Predictions of full scale sea level Redesigned Solid Rocket Motor (RSRM) and Advanced Solid Rocket Motor (ASRM) plume radiative heating to the Space Shuttle external tank (ET) dome center were also made. A comparison with the Development Flight Instrumentation (DFI) measurements is also provided.

Wang, K. C.↗

Multiple-time-stepping generalized hybrid Monte Carlo methods

Performance of the generalized shadow hybrid Monte Carlo (GSHMC) method [1], which proved to be superior in sampling efficiency over its predecessors [2–4], molecular dynamics and hybrid Monte Carlo, can be further improved by combining it with multi-time-stepping (MTS) and mollification of slow forces. We demonstrate that the comparatively simple modifications of the method not only lead to better performance of GSHMC itself but also allow for beating the best performed methods, which use the similar force splitting schemes. In addition we show that the same ideas can be successfully applied to the conventional generalized hybrid Monte Carlo method (GHMC). The resulting methods, MTS-GHMC and MTS-GSHMC, provide accurate reproduction of thermodynamic and dynamical properties, exact temperature control during simulation and computational robustness and efficiency. MTS-GHMC uses a generalized momentum update to achieve weak stochastic stabilization to the molecular dynamics (MD) integrator. MTS-GSHMC adds the use of a shadow (modified) Hamiltonian to filter the MD trajectories in the HMC scheme. We introduce a new shadow Hamiltonian formulation adapted to force-splitting methods. The use of such Hamiltonians improves the acceptance rate of trajectories and has a strong impact on the sampling efficiency of the method. Both methods were implemented in the open-source MD package ProtoMol and were tested on a water and a protein systems. Results were compared to those obtained using a Langevin Molly (LM) method [5] on the same systems. The test results demonstrate the superiority of the new methods over LM in terms of stability, accuracy and sampling efficiency. This suggests that putting the MTS approach in the framework of hybrid Monte Carlo and using the natural stochasticity offered by the generalized hybrid Monte Carlo lead to improving stability of MTS and allow for achieving larger step sizes in the simulation of complex systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid crystal free energy relaxation by a theoretically informed Monte Carlo method using a finite element quadrature approach

A theoretically informed Monte Carlo method is proposed for Monte Carlo simulation of liquid crystals on the basis of theoretical representations in terms of coarse-grained free energy functionals. The free energy functional is described in the framework of the Landau-de Gennes formalism. A piecewise finite element discretization is used to approximate the alignment field, thereby providing an excellent geometrical representation of curved interfaces and accurate integration of the free energy. The method is suitable for situations where the free energy functional includes highly non-linear terms, including chirality or high-order deformation modes. Finally, the validity of the method is established by comparing the results of Monte Carlo simulations to traditional Ginzburg-Landau minimizations of the free energy using a finite difference scheme, and its usefulness is demonstrated in the context of simulations of chiral liquid crystal droplets with and without nanoparticle inclusions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moment approach to the bootstrap current in nonaxisymmetric toroidal plasmas using {delta}f Monte Carlo methods

To evaluate the bootstrap current in nonaxisymmetric toroidal plasmas quantitatively, a {delta}f Monte Carlo method is incorporated into the moment approach. From the drift-kinetic equation with the pitch-angle scattering collision operator, the bootstrap current and neoclassical conductivity coefficients are calculated. The neoclassical viscosity is evaluated from these two monoenergetic transport coefficients. Numerical results obtained by the {delta}f Monte Carlo method for a model heliotron are in reasonable agreement with asymptotic formulae and with the results obtained by the variational principle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultracold atoms at unitarity within quantum Monte Carlo methods

Variational and diffusion quantum Monte Carlo (VMC and DMC) calculations of the properties of the zero-temperature fermionic gas at unitarity are reported. Our study differs from earlier ones mainly in that we have constructed more accurate trial wave functions and used a larger system size, we have studied the dependence of the energy on the particle density and well width, and we have achieved much smaller statistical error bars. The correct value of the universal ratio of the energy of the interacting to that of the noninteracting gas, {xi}, is still a matter of debate. We find DMC values of {xi} of 0.4244(1) with 66 particles and 0.4339(1) with 128 particles. The spherically averaged pair-correlation functions, momentum densities, and one-body density matrices are very similar in VMC and DMC, which suggests that our results for these quantities are very accurate. We find, however, some differences between the VMC and DMC results for the two-body density matrices and condensate fractions, which indicates that these quantities are more sensitive to the quality of the trial wave function. Our best estimate of the condensate fraction of 0.51 is smaller than the values from earlier quantum Monte Carlo calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Study into Validating a Coupled Method of Characteristics and Direct Simulation Monte Carlo Method Against Empirical Data

The following will outline the methodology and results of validating a coupled Method of Characteristics (MOC) and Direct Simulation Monte Carlo (DSMC) method. This research focused specifically on modeling plume impingement, induced by Reaction Control System (RCS) thrusters that flew on the National Aeronautics and Space Administration’s (NASA’s) space shuttle Discovery. For each simulation, the continuum portion of the RCS thruster was simulated using MOC for solving hyperbolic Partial Differential Equations (PDEs) and computed with the NASA code, Reacting and Multi-phase Program (RAMP). The solution was then implemented as a starting condition into the NASA DSMC code, Direct Simulation and Monte Carlo Analysis Code (DAC). Typically, DSMC models rely on code-to-code validation for fidelity. The significance of this research is in its ability to validate its models against empirical data. Prior to computing solutions for these simulations, the mesh size and structure were optimized and many variants of DSMC input parameters were iterated on in order to acquire a reliable, mesh-independent, fully optimized numerical solution. This research will discuss the mathematical formulation of MOC for nozzle flow and DSMC for rarefied gases. Additionally, it will provide an explanation of how to implement these mathematical concepts into the two solvers: RAMP and DAC. Ultimately, this research will demonstrate that the overall process illustrated produces results in good agreement with empirical data. As a consequence, the methodology presented is granted an increased level of confidence and will greatly contribute to the aerospace industry and its effort in understanding and predicting rarefied flow fields.

Direct Simulation Monte Carlo Analysis Code↗

A Study into Validating A Coupled Method of Characteristics And Direct Simulation Monte Carlo Method Against Empirical Data

The following will outline the methodology and results of validating a coupled Method of Characteristics (MOC) and Direct Simulation Monte Carlo (DSMC) method. This research focused specifically on modeling plume impingement, induced by Reaction Control System (RCS) thrusters that flew on the National Aeronautics and Space Administration’s (NASA’s) space shuttle Discovery. For each simulation, the continuum portion of the RCS thruster was simulated using MOC for solving hyperbolic Partial Differential Equations (PDEs) and computed with the NASA code, Reacting and Multi-phase Program (RAMP). The solution was then implemented as a starting condition into the NASA DSMC code, Direct Simulation and Monte Carlo Analysis Code (DAC). Typically, DSMC models rely on code-to-code validation for fidelity. The significance of this research is in its ability to validate its models against empirical data. Prior to computing solutions for these simulations, the mesh size and structure were optimized and many variants of DSMC input parameters were iterated on in order to acquire a reliable, mesh-independent, fully optimized numerical solution. This research will discuss the mathematical formulation of MOC for nozzle flow and DSMC for rarefied gases. Additionally, it will provide an explanation of how to implement these mathematical concepts into the two solvers: RAMP and DAC. Ultimately, this research will demonstrate that the overall process illustrated produces results in good agreement with empirical data. As a consequence, the methodology presented is granted an increased level of confidence and will greatly contribute to the aerospace industry and its effort in understanding and predicting rarefied flow fields.

DAC↗

SU-F-T-682: In-Vivo Simulation of the Relative Biological Effectiveness in Proton Therapy Using a Monte Carlo Method

Purpose: In proton therapy, the relative biological effectiveness (RBE) – compared with conventional photon therapy – is routinely set to 1.1. However, experimental in vitro studies indicate evidence for the variability of the RBE. To clarify the impact on patient treatment, investigation of the RBE in a preclinical case study should be performed. Methods: The Monte Carlo software TOPAS was used to simulate the radiation field of an irradiation setup at the experimental beamline of the proton therapy facility (OncoRay) in Dresden, Germany. Simulations were performed on cone beam CT-data (CBCT) of a xenogeneous mouse with an orthotopic lung carcinoma obtained by an in-house developed small animal image-guided radiotherapy device. A homogeneous physical fraction dose of 1.8Gy was prescribed for the contoured tumor volume. Simulated dose and linear energy transfer distributions were used to estimate RBE values in the mouse based on an RBE model by Wedenberg et al. To characterize radiation sensitivity of normal and tumor tissue, α/β-ratios were taken from the literature for NB1RGB (10.1Gy) and human squamous lung cancer (6.2Gy) cell lines, respectively. Results: Good dose coverage of the target volume was achieved with a spread-out Bragg peak (SOBP). The contra-lateral lung was completely spared from receiving radiation. An increase in RBE towards the distal end of the SOBP from 1.07 to 1.35 and from 1.05 to 1.3 was observed when considering normal tissue and tumor, respectively, with the highest RBE values located distal to the target volume. Conclusion: Modeled RBE values simulated on CBCT for experimental preclinical proton therapy varied with tissue type and depth in a mouse and differed therefore from a constant value of 1.1. Further translational work will include, first, conducting preclinical experiments and, second, analogous RBE studies in patients using experimentally verified simulation settings for our clinically used patient-specific beam conforming technique.

60 APPLIED LIFE SCIENCES↗

An Investigation of the Performance of the Unified Monte Carlo Method of Neutron Cross Section Data Evaluation

The Unified Monte Carlo method (UMC) has been suggested to avoid certain limitations and approximations inherent to the well-known Generalized Least Squares (GLS) method of nuclear data evaluation. This contribution reports on an investigation of the performance of the UMC method in comparison with the GLS method. This is accomplished by applying both methods to simple examples with few input values that were selected to explore various features of the evaluation process that impact upon the quality of an evaluation. Among the issues explored are: i) convergence of UMC results with the number of Monte Carlo histories and the ranges of sampled values; ii) a comparison of Monte Carlo sampling using the Metropolis scheme and a brute force approach; iii) the effects of large data discrepancies; iv) the effects of large data uncertainties; v) the effects of strong or weak model or experimental data correlations; and vi) the impact of ratio data and integral data. Comparisons are also made of the evaluated results for these examples when the input values are first transformed to comparable logarithmic values prior to performing the evaluation. Some general conclusions that are applicable to more realistic evaluation exercises are offered.

99 GENERAL AND MISCELLANEOUS↗

Self-learning quantum Monte Carlo method in interacting fermion systems

We present the self-learning Monte Carlo method is a powerful general-purpose numerical method recently introduced to simulate many-body systems. In this work, we extend it to an interacting fermion quantum system in the framework of the widely used determinant quantum Monte Carlo. This method can generally reduce the computational complexity and moreover can greatly suppress the autocorrelation time near a critical point. This enables us to simulate an interacting fermion system on a $100 × 100$ lattice even at the critical point and obtain critical exponents with high precision.

36 MATERIALS SCIENCE↗

APR1400 LBLOCA uncertainty quantification by Monte Carlo method and comparison with Wilks' formula

An analysis of the uncertainty quantification for the PWR LBLOCA by the Monte Carlo calculation has been performed and compared with the tolerance level determined by Wilks' formula. The uncertainty range and distribution of each input parameter associated with the LBLOCA accident were determined by the PIRT results from the BEMUSE project. The Monte-Carlo method shows that the 95. percentile PCT value can be obtained reliably with a 95% confidence level using the Wilks' formula. The extra margin by the Wilks' formula over the true 95. percentile PCT by the Monte-Carlo method was rather large. Even using the 3 rd order formula, the calculated value using the Wilks' formula is nearly 100 K over the true value. It is shown that, with the ever increasing computational capability, the Monte-Carlo method is accessible for the nuclear power plant safety analysis within a realistic time frame. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimized structure and electronic band gap of monolayer GeSe from quantum Monte Carlo methods

Here, we have used highly accurate quantum Monte Carlo methods to determine the chemical structure and electronic band gaps of monolayer GeSe. Two-dimensional (2D) monolayer GeSe has received a great deal of attention due to its unique thermoelectric, electronic, and optoelectronic properties with a wide range of potential applications. Density functional theory (DFT) methods have usually been applied to obtain optical and structural properties of bulk and 2D GeSe. For the monolayer, DFT typically yields a larger band-gap energy than for bulk GeSe but cannot conclusively determine if the monolayer has a direct or indirect gap. Moreover, the DFT-optimized lattice parameters and atomic coordinates for monolayer GeSe depend strongly on the choice of approximation for the exchange-correlation functional, which makes the ideal structure-and its electronic properties-unclear. In order to obtain accurate lattice parameters and atomic coordinates for the monolayer, we use a surrogate Hessian-based parallel line search within diffusion Monte Carlo to fully optimize the GeSe monolayer structure. The DMC-optimized structure is different from those obtained using DFT, as are calculated band gaps. The potential energy surface has a shallow minimum at the optimal structure. This, combined with the sensitivity of the electronic structure to strain, suggests that the optical properties of monolayer GeSe are highly tunable by strain.

36 MATERIALS SCIENCE↗

Successful combination of the stochastic linearization and Monte Carlo methods

A combination of a stochastic linearization and Monte Carlo techniques is presented for the first time in literature. A system with separable nonlinear damping and nonlinear restoring force is considered. The proposed combination of the energy-wise linearization with the Monte Carlo method yields an error under 5 percent, which corresponds to the error reduction associated with the conventional stochastic linearization by a factor of 4.6.

Elishakoff, I.↗

An Efficient Monte Carlo Method for Modeling Radiative Transfer in Protoplanetary Disks

Monte Carlo methods have been shown to be effective and versatile in modeling radiative transfer processes to calculate model temperature profiles for protoplanetary disks. Temperatures profiles are important for connecting physical structure to observation and for understanding the conditions for planet formation and migration. However, certain areas of the disk such as the optically thick disk interior are under-sampled, or are of particular interest such as the snow line (where water vapor condenses into ice) and the area surrounding a protoplanet. To improve the sampling, photon packets can be preferentially scattered and reemitted toward the preferred locations at the cost of weighting packet energies to conserve the average energy flux. Here I report on the weighting schemes developed, how they can be applied to various models, and how they affect simulation mechanics and results. We find that improvements in sampling do not always imply similar improvements in temperature accuracies and calculation speeds.

radiative transfer↗

Monte Carlo methods and their analysis for Coulomb collisions in multicomponent plasmas

Highlights: •A general approach to Monte Carlo methods for multicomponent plasmas is proposed. •We show numerical tests for the two-component (electrons and ions) case. •An optimal choice of parameters for speeding up the computations is discussed. •A rigorous estimate of the error of approximation is proved. -- Abstract: A general approach to Monte Carlo methods for Coulomb collisions is proposed. Its key idea is an approximation of Landau–Fokker–Planck equations by Boltzmann equations of quasi-Maxwellian kind. It means that the total collision frequency for the corresponding Boltzmann equation does not depend on the velocities. This allows to make the simulation process very simple since the collision pairs can be chosen arbitrarily, without restriction. It is shown that this approach includes the well-known methods of Takizuka and Abe (1977) [12] and Nanbu (1997) as particular cases, and generalizes the approach of Bobylev and Nanbu (2000). The numerical scheme of this paper is simpler than the schemes by Takizuka and Abe [12] and by Nanbu. We derive it for the general case of multicomponent plasmas and show some numerical tests for the two-component (electrons and ions) case. An optimal choice of parameters for speeding up the computations is also discussed. It is also proved that the order of approximation is not worse than O(√(ε)), where ε is a parameter of approximation being equivalent to the time step Δt in earlier methods. A similar estimate is obtained for the methods of Takizuka and Abe and Nanbu.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗