Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Transition from Vogel-Fulcher-Tammann to Arrhenius Ion-Conducting Behavior in Poly(Ethyl Acrylate)-Based Solid Polymer Electrolytes via Succinonitrile Plasticizer Addition

Solid polymer electrolytes (SPEs) offer potential advantages over liquid electrolytes, including flexibility, safety, and processability. However, they suffer from low room-temperature ionic conductivity. Recently, it has been reported a poly(ethyl acrylate) based (polyEA) SPE, by incorporating 50 wt% of succinonitrile (SN) solid plasticizer, 30 wt% of lithium salt and 5 wt% of fluoroethylene carbonate additive, which achieves a high room-temperature ionic conductivity of 1.01 × 10 −3 S cm −1 (Nat. Nanotechnol, 2022, 17, 768-776). This novel SPE exhibits stability against Li 0 and anodic stability up to 4.9 V vs Li + /Li. However, the specific mechanism responsible for its high ionic conductivity remains elusive. In this work, by adjusting the weight ratio of SN in the SPE, a transition from Vogel-Fulcher-Tammann to Arrhenius ion-conducting behavior is observed. It is demonstrated that the addition of SN leads to the gradual decoupling of Li-ion from the polymer backbone and its coordination with SN, as revealed by 6 Li solid-state nuclear magnetic resonance spectroscopy. As a result, Li-ion migration primarily occurs through SN rather than the segmental motion of the polymer backbone. Performances of the SPE in Cu||Li, Li||Li and a LiFePO 4 ||Li pouch cells are shown to demonstrate the commercial viability of this SPE in Li 0 -anode solid-state batteries.

Electrochemistry↗

Relaxation Dynamics and Ion Conduction of Poly(Ethylene Carbonate/Ethylene Oxide) Copolymer-Based Electrolytes

Poly(ethylene carbonate/ethylene oxide) P(EC/EO) copolymer was synthesized from EC monomer as a new matrix component of solid polymer electrolytes (SPEs), and the correlation between polymer dynamics and ionic conductivity in the P(EC/EO)-based SPEs at various lithium salt weight fractions (w Li ) was investigated by dielectric spectroscopy, rheology, and molecular dynamics (MD) simulations. With the addition of lithium salt, the molecular motions at various scales (i.e., from local to segmental and global motion scales) were found to change as follows: (i) the local motion of P(EC/EO) was slightly accelerated, and at w Li ≥ 0.22, it was separated into two relaxation modes, one faster and the other slower than that of P(EC/EO), (ii) the segmental motion of P(EC/EO) became significantly slower with the addition of lithium salt, and (iii) the global terminal relaxation became slightly slower with the increase of w Li . Thus, the motion of P(EC/EO) at various scales in SPEs changed with different trends with increasing lithium salt. It was also found that the temperature dependence of the ionic conductivity was described by a Vogel–Fulcher–Tammann-type function, which was correlated with the segmental motion, as is known in other SPE systems. Furthermore, from MD simulations, lithium ions are coordinated with the EC units more likely and with a closer distance than EO units in P(EC/EO), and the coordination number of oxygens around one lithium ion was estimated as 6–7 at the distance of 0.30 nm. Here, these results suggest that the coordination structure of the oxygens around the lithium ion is slightly disrupted due to the presence of EC units compared to the chelating structure of pure PEO electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Negative Matrix Factorization of Partial Track Data for Motion

This paper addresses the problem of segmenting low level partial feature point tracks belonging to multiple motions. We show that the local velocity vectors at each instant of the trajectory are an effective basis for motion segmentation. We decompose the velocity profiles of point tracks into different motion components and corresponding nonnegative weights using non-negative matrix factorization (NNMF). We then segment the different motions using spectral clustering on the derived weights. We test our algorithm on the Hopkins 155 benchmarking database and several new sequences, demonstrating that the proposed algorithm can accurately segment multiple motions at a speed of a few seconds per frame. We show that our algorithm is particularly successful on low-level tracks from real-world video that are fragmented, noisy and inaccurate

Computer Vision↗

Fluctuation suppression in microgels by polymer electrolytes

Structural details of thermoresponsive, cationically poly(N-iso-propylacrylamide-co-methacrylamido propyl trimethyl ammonium chloride) microgels and the influence of the anionic electrolyte polystyrene sulfonate (PSS) on the internal structure and dynamics of the cationic microgels have been studied with a combination of small angle neutron scattering (SANS) and neutron spin echo (NSE) spectroscopy. While SANS can yield information on the overall size of the particles and on the typical correlation length inside the particles, studying the segmental polymer dynamics with NSE gives access to more internal details, which only appear due to their effect on the polymer motion. The segmental dynamics of the microgels studied in this paper is to a large extent suppressed by the PSS additive. Possible scenarios of the influence of the polyanions on the microgel structure and dynamics are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-B-BRD-00: MRI for Radiation Oncology

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-01: MR-LINAC

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-02: MR Simulation for Radiation Therapy

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-03: MR QA/QC for MRgRT

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

Thermally Rearranged Polymer Membranes Containing Tröger's Base Units Have Exceptional Performance for Air Separations

Abstract The influence of segmental chain motion on the gas separation performance of thermally rearranged (TR) polymer membranes is established for TR polybenzoxazoles featuring Tröger's base (TB) monomer subunits as exceptionally rigid sites of contortion along the polymer backbone. These polymers are accessed from solution‐processable ortho‐acetate functionalized polyimides, which are readily synthesized as high‐molecular‐weight polymers for membrane casting. We find that thermal rearrangement leads to a small increase in d‐spacing between polymer chains and a dramatic pore‐network reconfiguration that increases both membrane permeability and O 2 /N 2 selectivity, putting its performance above the 2015 upper bound.

Meckler, Stephen M.↗

Thermally Rearranged Polymer Membranes Containing Tröger's Base Units Have Exceptional Performance for Air Separations

The influence of segmental chain motion on the gas separation performance of thermally rearranged (TR) polymer membranes is established for TR polybenzoxazoles featuring Tröger's base (TB) monomer subunits as exceptionally rigid sites of contortion along the polymer backbone. These polymers are accessed from solution-processable ortho-acetate functionalized polyimides, which are readily synthesized as high-molecular-weight polymers for membrane casting. We discover that thermal rearrangement leads to a small increase in d-spacing between polymer chains and a dramatic pore-network reconfiguration that increases both membrane permeability and O 2 /N 2 selectivity, enabling its performance above the 2015 upper bound.

36 MATERIALS SCIENCE↗

Glassy polymers: Historical findings, membrane applications, and unresolved questions regarding physical aging

Polymers below their glass transition temperature (Tg) are non-equilibrium glasses because excess free volume “frozen” between kinetically-restricted polymer chains slowly relaxes over time towards equilibrium via local, segmental chain motion. This process, known as physical aging, is observed through time-dependent decreases in a polymer's specific volume, enthalpy, etc. This article focuses on the history of glassy polymers in membrane separation applications. Open questions regarding the influence of thickness (e.g., membrane geometry) and temperature on physical aging in glassy polymers are highlighted.

36 MATERIALS SCIENCE↗

Structure and Dynamics of Ionic Block Copolymer Melts: Computational Study

Structure and dynamics of melts of copolymers with an ABCBA topology, where C is an ionizable block, have been studied by fully atomistic molecular dynamics (MD) simulations. Introducing an ionizable block for functionality adds a significant element to the coupled set of interactions that determine the structure and dynamics of the macromolecule. The polymer consists of a randomly sulfonated polystyrene C block tethered to a flexible poly(ethylene-r-propylene) bridge B and end-capped with poly(tert-butylstyrene) A. The chemical structure and topology of these polymers constitute a model for incorporation of ionic blocks within a framework that provides tactility and mechanical stability. Here in this paper we resolve the structure and dynamics of a structured polymer on the nanoscale constrained by ionic clusters. We find that the melts form intertwined networks of the A and C blocks independent of the degree of sulfonation of the C block with no long-range order. The cluster cohesiveness and morphology affect both macroscopic translational motion and segmental dynamics of all the blocks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The diffusion and conduction of lithium in poly(ethylene oxide)-based sulfonate ionomers

Pulsed field gradient nuclear magnetic resonance spectroscopy and dielectric relaxation spectroscopy have been utilized to investigate lithium dynamics within poly(ethylene oxide) (PEO)-based lithium sulfonate ionomers of varying ion content. The ion content is set by the fraction of sulfonated phthalates and the molecular weight of the PEO spacer, both of which can be varied independently. The molecular level dynamics of the ionomers are dominated by either Vogel-Fulcher-Tammann or Arrhenius behavior depending on ion content, spacer length, temperature, and degree of ionic aggregation. In these ionomers the main determinants of the self-diffusion of lithium and the observed conductivities are the ion content and ionic states of the lithium ion, which are profoundly affected by the interactions of the lithium ions with the ether oxygens of the polymer. Since many lithium ions move by segmental polymer motion in the ion pair state, their diffusion is significantly larger than that estimated from conductivity using the Nernst-Einstein equation.

LaFemina, Nikki H.↗

Segmented strings and the McMillan map

We present new exact solutions describing motions of closed segmented strings in AdS 3 in terms of elliptic functions. The existence of analytic expressions is due to the integrability of the classical equations of motion, which in our examples reduce to instances of the McMillan map. Here, we also obtain a discrete evolution rule for the motion in AdS 3 of arbitrary bound states of fundamental strings and D1-branes in the test approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of the lignin glass transition

The dynamics of lignin, a complex and heterogeneous major plant cell-wall macromolecule, is of both fundamental and practical importance. Lignin is typically heated to temperatures above its glass transition to facilitate its industrial processing. Here, we performed molecular dynamics simulations to investigate the segmental (α) relaxation of lignin, the dynamical process that gives rise to the glass transition. It is found that lignin dynamics involves mainly internal motions below T g , while segmental inter-molecular motions are activated above T g . The segments whose mobility is enhanced above T g consist of 3–5 lignin monomeric units. The temperature dependence of the lignin segmental relaxation time changes from Arrhenius below T g to Vogel–Fulcher–Tamman above T g . This change in temperature dependence is determined by the underlying energy landscape being restricted below T g but exhibiting multiple minima above T g . The Q-dependence of the relaxation time is found to obey a power-law up to Q max , indicative of sub-diffusive motion of lignin above T g . Temperature and hydration affect the segmental relaxation similarly. Increasing hydration or temperature leads to: (1) the α process starting earlier, i.e. the beta process becomes shortened, (2) Q max decreasing, i.e. the lengthscale above which subdiffusion is observed increases, and (3) the number of monomers constituting a segment increasing, i.e. the motions that lead to the glass transition become more collective. The above findings provide molecular-level understanding of the technologically important segmental motions of lignin and demonstrate that, despite the heterogeneous and complex structure of lignin, its segmental dynamics can be described by concepts developed for chemically homogeneous polymers.

09 BIOMASS FUELS↗

Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor excursion outside of the gating window, which, for our study group, is mainly caused by baseline shift, i.e., the change in general trend of the motion curve during extended period of treatment time. Conclusions: The dose deviation in PTV and CTV due to target motion is not always negligible in gated SBRT. Although CTVs are covered sufficiently with prescribed dose in most cases, some are on the verge of underdose due to large tumor excursion caused by factors such as baseline shift.

60 APPLIED LIFE SCIENCES↗

Multi Segment Fault Rupture Modeling and Strong Ground Motion Simulation Using Irikura, Japan Recipe: Implementation in the in SCEC BB Platform

The project had two main objectives. The first objective was to complete the implementation of an earthquake rupture generator based on the method proposed by Irikura and Miyake, also known as Irikura recipe (IM2011 method hereafter), in the BBP by extending its formulation to multi-segment rupture, and developing the software infrastructure. The second objective was to investigate the possibility of using the earthquake rupture generator as a standalone BBP rupture module that can be attached to other strong ground motion simulation methods already in use in the BBP. We successfully tested and validated the IM2011 multi-segment rupture generator in conjunction with Graves and Pitarka method (GP, hereafter) one of the BBP methods, and performed simulations of the M7.0 2016 Kumamoto, Japan earthquake. IM2011 is the most popular method in Japan that is used to simulate strong ground motion from Japanese crustal earthquakes. In response to technical requirements of the BBP, we made Irikura’s rupture generator procedure compatible with multi-segment rupture modeling approach, currently being adopted by BBP. The recipe is now fully functional on the BBP. This project benefited from the collaboration of the PI with professor Kojiro Irikura of Aichi Institute of Technology, Japan, assistant professor Hiroe Miyake of University of Tokyo, head of the Japanese side of collaboration with SCEC, and Dr.Iwaki and Dr. Morikawa, researchers at NIED, during which we identified rupture parameters that needed to be adjusted and investigated.

58 GEOSCIENCES↗

A Comparison of Amplitude-Based and Phase-Based Positron Emission Tomography Gating Algorithms for Segmentation of Internal Target Volumes of Tumors Subject to Respiratory Motion

Purpose: To quantitatively compare the accuracy of tumor volume segmentation in amplitude-based and phase-based respiratory gating algorithms in respiratory-correlated positron emission tomography (PET). Methods and Materials: List-mode fluorodeoxyglucose-PET data was acquired for 10 patients with a total of 12 fluorodeoxyglucose-avid tumors and 9 lymph nodes. Additionally, a phantom experiment was performed in which 4 plastic butyrate spheres with inner diameters ranging from 1 to 4 cm were imaged as they underwent 1-dimensional motion based on 2 measured patient breathing trajectories. PET list-mode data were gated into 8 bins using 2 amplitude-based (equal amplitude bins [A1] and equal counts per bin [A2]) and 2 temporal phase-based gating algorithms. Gated images were segmented using a commercially available gradient-based technique and a fixed 40% threshold of maximum uptake. Internal target volumes (ITVs) were generated by taking the union of all 8 contours per gated image. Segmented phantom ITVs were compared with their respective ground-truth ITVs, defined as the volume subtended by the tumor model positions covering 99% of breathing amplitude. Superior-inferior distances between sphere centroids in the end-inhale and end-exhale phases were also calculated. Results: Tumor ITVs from amplitude-based methods were significantly larger than those from temporal-based techniques (P=.002). For lymph nodes, A2 resulted in ITVs that were significantly larger than either of the temporal-based techniques (P<.0323). A1 produced the largest and most accurate ITVs for spheres with diameters of ≥2 cm (P=.002). No significant difference was shown between algorithms in the 1-cm sphere data set. For phantom spheres, amplitude-based methods recovered an average of 9.5% more motion displacement than temporal-based methods under regular breathing conditions and an average of 45.7% more in the presence of baseline drift (P<.001). Conclusions: Target volumes in images generated from amplitude-based gating are larger and more accurate, at levels that are potentially clinically significant, compared with those from temporal phase-based gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗