Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplex imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

53 records · Page 3

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploiting universal nonlocal dispersion in optically active materials for spectro-polarimetric computational imaging

Recent years have seen significant advancements in exploring novel light-matter interactions such as hyperbolic dispersion within natural crystals. However, current studies have predominantly concentrated on local optical response of materials characterized by a dielectric tensor without spatial dispersion. Here, we investigate the nonlocal response in optically-active crystals with screw symmetries, revealing their lossless, super-dispersive properties compared to traditional optical response functions. We leverage this universal nonlocal dispersion, i.e. the dispersion of optical rotatory power, to explore a novel spectral de-multiplexing scheme compared to conventional gratings, prisms and metasurfaces. We design and demonstrate an ‘Nonlocal-Cam’ - a camera that exploits nonlocal dispersion through sampling of polarized spectral states and the application of computational spectral reconstruction algorithms. The Nonlocal-Cam captures information in both laboratory and outdoor field experiments which is unavailable to traditional intensity cameras - the spectral texture of polarization. Merging the fields of nonlocal electrodynamics and computational imaging, our work paves the way for exploiting nonlocal optics of optically active materials in a variety of applications, from biological microscopy to physics-driven machine vision and remote sensing.

Wang, Xueji [Purdue Univ., West Lafayette, IN (Uni↗

Meta-optic accelerators for object classifiers

Rapid advances in deep learning have led to paradigm shifts in a number of fields, from medical image analysis to autonomous systems. These advances, however, have resulted in digital neural networks with large computational requirements, resulting in high energy consumption and limitations in real-time decision-making when computation resources are limited. Here, we demonstrate a meta-optic–based neural network accelerator that can off-load computationally expensive convolution operations into high-speed and low-power optics. In this architecture, metasurfaces enable both spatial multiplexing and additional information channels, such as polarization, in object classification. End-to-end design is used to co-optimize the optical and digital systems, resulting in a robust classifier that achieves 93.1% accurate classification of handwriting digits and 93.8% accuracy in classifying both the digit and its polarization state. This approach could enable compact, high-speed, and low-power image and information processing systems for a wide range of applications in machine vision and artificial intelligence.

42 ENGINEERING↗

Photoinitiated Reactions of Molecules and Radicals in Molecular Beams

The UV photochemistry of organic molecules is a fundamental process that governs reactions in the atmosphere, synthetic chemistry, processing of organic aerosols, and biological damage in living tissues. In many organic molecules, the ensuing evolution involves pathways that are in competition, giving rise to different products, isomerization, coupling to other electronic states, and secondary reactive collisions. Because photodissociation is usually fast (picoseconds to microseconds), these processes are far from equilibrium and are controlled by kinetic competition and dynamical forces. The work accomplished was focused primarily on the photochemistry of alpha-keto carboxylic acids, a group of acids produced from natural sources, which are implicated in aerosol formation and biological processes. In the atmosphere, they are destroyed mainly by solar radiation. Studying their photochemistry has been surprisingly difficult because of the complexity of their excited electronic states, and the effect of collisions and secondary reactions. The second project investigated the lifetime of excited electronic states of pyrazine and picoline and had both experimental and theoretical aspects. The work focused on a model molecule, pyruvic acid (PA), because it was hypothesized that it should be a good source of the unstable carbene, methylhydroxycarbene (MHC). PA has an internal hydrogen bond that controls the evolution of its decomposition. The decomposition was studied following excitation to two of its lowest excited states reached by laser irradiation at 351 and 193 nm. The photodissociation dynamics in the absence and presence of collisions was monitored and compared. Understanding the UV photochemistry requires the use of complementary experimental approaches. Two methods were enlisted, which together generated a comprehensive and detailed set of results: (i) The time-sliced velocity map imaging (SVMI) instrument at USC was exploited to determine kinetic energy release of fragments, fast dissociation timescales, and internal state distributions of fragments for which Resonance Enhanced Multiphoton Ionization (REMPI) schemes exist; and (ii) The multiplexed photoionization mass spectrometer (MPIMS) setup developed at the Sandia Combustion Research Facility was used for product discovery, achieved by exploiting tunable narrowband VUV radiation at the Advanced Light Source (ALS), and to follow in real time their subsequent unimolecular and bimolecular reactions. The experimental conditions ranged from collisionless molecular beams to study nascent products to flow reactors of variable pressures to study subsequent bimolecular reactions of the products. The goals stated above were successfully accomplished. By exciting PA to its lowest excited state, MHC was identified as the only primary product and its isomerization to vinylalcohol and acetaldehyde was directly observed in real time. Moreover, we reported the first bimolecular reaction of MHC, which was with acetaldehyde, and identified its reaction product. This paves the way for the study of other reactions of this important carbene intermediate. When excitation was carried out at 193 nm, which imparted much higher energy to PA, many more products were directly observed in real time, some deriving from three-body dissociation. Quantitative branching ratios and secondary reactions of radical products were also determined and analyzed. The studies of pyrazine and picoline focused on the second excited state of these molecules and showed (via ionization studies) that their excited states were very short lived (<100 fs) because of efficient couplings to lower electronic states via vibronic coupling. Theoretical work on modeling the absorption spectrum and decay mechanisms of the excited states are in progress in collaboration with theoreticians.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

A Bright, Photostable, and Far-Red Dye That Enables Multicolor, Time-Lapse, and Super-Resolution Imaging of Acidic Organelles

Lysosomes have long been known for their acidic lumens and efficient degradation of cellular byproducts. In recent years, it has become clear that their function is far more sophisticated, involving multiple cell signaling pathways and interactions with other organelles. Unfortunately, their acidic interior, fast dynamics, and small size make lysosomes difficult to image with fluorescence microscopy. Here we report a far-red small molecule, HMSiR 680 -Me, that fluoresces only under acidic conditions, causing selective labeling of acidic organelles in live cells. HMSiR 680 -Me can be used alongside other far-red dyes in multicolor imaging experiments and is superior to existing lysosome probes in terms of photostability and maintaining cell health and lysosome motility. We demonstrate that HMSiR 680 -Me is compatible with overnight time-lapse experiments as well as time-lapse super-resolution microscopy with a frame rate of 1.5 fps for at least 1000 frames. HMSiR 680 -Me can also be used alongside silicon rhodamine dyes in a multiplexed super-resolution microscopy experiment to visualize interactions between mitochondria and lysosomes with only a single excitation laser and simultaneous depletion. We envision this dye permitting a more detailed study of the role of lysosomes in dynamic cellular processes and disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-molecule live-cell RNA imaging with CRISPR–Csm

Abstract Understanding the diverse dynamic behaviors of individual RNA molecules in single cells requires visualizing them at high resolution in real time. However, single-molecule live-cell imaging of unmodified endogenous RNA has not yet been achieved in a generalizable manner. Here, we present single-molecule live-cell fluorescence in situ hybridization (smLiveFISH), a robust approach that combines the programmable RNA-guided, RNA-targeting CRISPR–Csm complex with multiplexed guide RNAs for direct and efficient visualization of single RNA molecules in a range of cell types, including primary cells. Using smLiveFISH, we track individual nativeNOTCH2andMAP1Btranscripts in living cells and identify two distinct localization mechanisms including the cotranslational translocation ofNOTCH2mRNA at the endoplasmic reticulum and directional transport ofMAP1BmRNA toward the cell periphery. This method has the potential to unlock principles governing the spatiotemporal organization of native transcripts in health and disease.

Biotechnology & Applied Microbiology↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Spectroscopy with DESI for Photometric Redshift Training and Calibration

Deep spectroscopic samples can improve photometric redshift (photo-z) estimates and reduce uncertainties on redshift distributions. Such improvements can increase the cosmological constraining power of large imaging-based experiments such as the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and mitigate what may be a limiting systematic effect. We present results from the “DESI-Deep pilot” program, which was designed to assess the capability of the Dark Energy Spectroscopic Instrument (DESI) on the 4m Mayall telescope to measure redshifts of galaxies as faint as expected lensing samples for early LSST data (m i ≤ 24.5). We find that DESI is remarkably efficient at this task, with redshift success rates comparable to the results of observations from 10 m class telescopes with only ∼2 × longer integration time (rather than ∼8 × longer as would be expected from aperture-area scaling), while simultaneously achieving ∼30 times larger multiplexing. We also find that the signal-to-noise ratio of the spectra scales as expected for background-limited observations even for the longest exposure times (∼7 hr) and faintest targets in the program. These results demonstrate that DESI could provide the definitive redshift sample for the early years of LSST with a modest investment of observing time. Based upon the results of this program, we provide updated predictions for the time required to collect benchmark samples for photo-z training and calibration using a variety of spectroscopic facilities. Finally, we describe a potential “DESI-Deep” survey designed to train and calibrate photo-z’s for imaging experiments, and provide forecasts of its impact on cosmological inference.

Dey, Biprateep [University of Toronto; University ↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of the SPT-SLIM Focal Plane: A Spectroscopic Imaging Array for the South Pole Telescope

The Summertime Line Intensity Mapper (SLIM) is a mm-wave line-intensity mapping (mm-LIM) experiment for the South Pole Telescope (SPT). The goal of SPT-SLIM is to serve as a technical and scientific pathfinder for the demonstration of the suitability and in-field performance of multi-pixel superconducting filterbank spectrometers for future mm-LIM experiments. Scheduled to deploy in the 2023-24 austral summer, the SPT-SLIM focal plane will include 18 dual-polarisation pixels, each coupled to an $R = \lambda / \Delta \lambda = 300$ thin-film microstrip filterbank spectrometer that spans the 2 mm atmospheric window (120–180 GHz). Each individual spectral channel feeds a microstrip-coupled lumped-element kinetic inductance detector, which provides the highly multiplexed readout for the 10k detectors needed for SPT-SLIM. Here, we present an overview of the preliminary design of key aspects of the SPT-SLIM focal plane array, a description of the detector architecture and predicted performance, and initial test results that will be used to inform the final design of the SPT-SLIM spectrometer array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Massively parallel and universal approximation of nonlinear functions using diffractive processors

Nonlinear computation is essential for a wide range of information processing tasks, yet implementing nonlinear functions using optical systems remains a challenge due to the weak and power-intensive nature of optical nonlinearities. Overcoming this limitation without relying on nonlinear optical materials could unlock unprecedented opportunities for ultrafast and parallel optical computing systems. Here, we demonstrate that large-scale nonlinear computation can be performed using linear optics through optimized diffractive processors composed of passive phase-only surfaces. In this framework, the input variables of nonlinear functions are encoded into the phase of an optical wavefront—e.g., via a spatial light modulator (SLM)—and transformed by an optimized diffractive structure with spatially varying point-spread functions to yield output intensities that approximate a large set of unique nonlinear functions–all in parallel. We provide proof establishing that this architecture serves as a universal function approximator for an arbitrary set of bandlimited nonlinear functions, also covering wavelength-multiplexed nonlinear functions as well as multi-variate and complex-valued functions that are all-optically cascadable. Our analysis also indicates the successful approximation of typical nonlinear activation functions commonly used in neural networks, including the sigmoid, tanh, ReLU (rectified linear unit), and softplus. We numerically demonstrate the parallel computation of one million distinct nonlinear functions, accurately executed at wavelength-scale spatial density at the output of a diffractive optical processor. Furthermore, we experimentally validated this framework using in situ optical learning and approximated 35 unique nonlinear functions in a single shot using a compact setup consisting of an SLM and an image sensor. These results establish diffractive optical processors as a scalable platform for massively parallel universal nonlinear function approximation, paving the way for new capabilities in analog optical computing based on linear materials.

Rahman, Md Sadman Sakib [University of California,↗

Orthogonal luminescence lifetime encoding by intermetallic energy transfer in heterometallic rare-earth MOFs

Lifetime-encoded materials are particularly attractive as optical tags, however examples are rare and hindered in practical application by complex interrogation methods. Here, we demonstrate a design strategy towards multiplexed, lifetime-encoded tags via engineering intermetallic energy transfer in a family of heterometallic rare-earth metal-organic frameworks (MOFs). The MOFs are derived from a combination of a high-energy donor (Eu), a low-energy acceptor (Yb) and an optically inactive ion (Gd) with the 1,2,4,5 tetrakis(4-carboxyphenyl) benzene (TCPB) organic linker. Precise manipulation of the luminescence decay dynamics over a wide microsecond regime is achieved via control over metal distribution in these systems. Demonstration of this platform’s relevance as a tag is attained via a dynamic double encoding method that uses the braille alphabet, and by incorporation into photocurable inks patterned on glass and interrogated via digital high-speed imaging. This study reveals true orthogonality in encoding using independently variable lifetime and composition, and highlights the utility of this design strategy, combining facile synthesis and interrogation with complex optical properties.

36 MATERIALS SCIENCE↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Lasing from Finite Plasmonic Nanoparticle Lattices

Small lasers can generate coherent light for integrated photonics, in-vivo cellular imaging, and solid-state lighting. Unlike conventional lasers, plasmonic lasers can generate coherent light at sub-wavelength scales, although cavity architectures based on metal films and semiconducting gain exhibit large radiative losses and lack directional emission. In contrast, two-dimensional (2D) metal nanoparticle arrays surrounded by organic dyes can support lasing with high directionality at room temperature. Yet, the relationship between the number of nanoparticles in a finite lattice and their lasing emission characteristics is unknown. Here we show that the number of units in 2D gold nanoparticle lattices is critical to generate robust cavity resonances and lasing emission. Narrower lattice plasmons associated with stronger electromagnetic near fields are observed as nanoparticle number increases. Experimentally, we demonstrate lasing from a 30x30 nanoparticle lattice. Semi-quantum modeling indicates lower lasing thresholds and faster population inversion dynamics with higher nanoparticle numbers. These findings indicate that finite lattices of nanoparticles integrated with gain can function as independent, coherent light sources for optical multiplexing and lab-on-a-chip applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗