Search NASA⌕ Search

SEARCH · Search NASA

Results for “NAWI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

EIA Thermoelectric Water Cooling Data

The U.S. Energy Information Administration (EIA) collects water cooling data for the electric power industry in the United States. This submission includes annual data from 2014 to 2019. Each spreadsheet details the generator type, fuel consumption, water consumption, cooling type, and equipment status, location, and water source for each plant.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US Municipal Desalination Plants

This submission presents results and observations from a series of surveys of US municipal desalination plants conducted during the last 20 years. The surveys were conducted to determine the number, characteristics, and concentrate disposal practices of US desalination plants. Each survey was intended to identify and contact each US plant that produces 25,000 gpd or more. This cutoff eliminated smaller plants that serve truck stops, mobile home parks, hospitals, campgrounds, etc. Succeeding surveys did not undertake to recontact all previously contacted plants but focused primarily on plants built since the initial survey.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Benchmark Model for Wastewater Treatment Using an Activated Sludge Process

This is benchmark model for wastewater treatment using an activated sludge process. The activated sludge process is a means of treating both municipal and industrial wastewater. The activated sludge process is a multi-chamber reactor unit that uses highly concentrated microorganisms to degrade organics and remove nutrients from wastewater, producing quality effluent. This model provides pollutant concentrations, mass balance, electricity requirements, and treatment costs. This model will be continuously updated based on the latest data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Catalyst Design in Nitrate Removal

Based on the volcano plot developed by Dr. Goldsmith group (Report linked in submission), we utilized DFT (density functional theory) calculations to search for bimetallic materials in the application of catalysts in aqueous nitrate removal. The calculations are conducted via the high-throughput automated workflow package developed by our group (Github linked in submission) using VASP commercial first-principles calculation software.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WaterTAP-REFLO models of Solar Still, Solar Still ZLD, Enhanced Evaporation pond results for baseline analysis

This folder contains results from models that were adapted into WaterTAP-REFLO. The files contain inputs and outputs for solar still, solar still ZLD, and enhanced evaporation pond unit process models for 4 different locations in the USA: Phoenix, Miami, Houston, and Baltimore. The WaterTAP-REFLO implementation may be different and thus may have different results. The data structure and content are described in a ReadMe.txt file. For WaterTAP-REFLO documentation and/or contact the developers please see: https://github.com/watertap-org/watertap-reflo.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Building Loads Providing Ancillary Services in PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

54 ENVIRONMENTAL SCIENCES↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗