Search NASA⌕ Search

SEARCH · Search NASA

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The effect of cloud type on Earth's energy balance - Global analysis

The role of fractional area coverage by cloud types in the energy balance of the earth is investigated through joint use of International Satellite Cloud Climatology Project (ISCCP) C1 cloud data and Earth Radiation Budget Experiment (ERBE) broadband energy flux data for the one-year period March 1985 through February 1986. Multiple linear regression is used to relate the radiation budget data to the cloud data. Comparing cloud forcing estimates obtained from the ISCCP-ERBE regression with those derived from the ERBE scene identification shows generally good agreement except over snow, in tropical convective regions, and in regions that are either nearly cloudless or always overcast. It is suggested that a substantial fraction of the disagreement in longwave cloud forcing in tropical convective regions is associated with the fact that the ERBE scene identification does not take into account variations in upper-tropospheric water vapor. On a global average basis, low clouds make the largest contribution to the net energy balance of the Earth, because they cover such a large area and because their albedo effect dominates their effect on emitted thermal radiation. High, optically thick clouds can also very effectively reduce the energy balance, however, because their very high albedos overcome their low emission temperatures.

Hartmann, Dennis L.↗

TPSAS-NF1676L-33231-DND

It is well established that clouds have a profound influence on Earth's energy budget and that cloud feedbacks are responsible for much of the uncertainty in climate model projections of global warming in response to radiative forcing by greenhouse gases. While most model evaluation efforts focus on model representation of the observed mean state. For example, the regional mean climatology of key climate variables there is also tremendous value in testing how a model represents observed internal variations of the climate system. Here we use CERES observations during and after the so-called global warming hiatus to evaluate a subset of CMIP6 climate models. The CERES data show a marked 0.83 Wm-2 reduction in global mean reflected SW TOA flux during the three years following the hiatus that results in an increase in net energy into the climate system. The primary driver of the decrease in SW TOA flux is a reduction in low cloud cover over the eastern Pacific Ocean that occurs in response to an unprecedented increase in SSTs in that region following the hiatus. The CMIP6 simulations consist of AMIP-style experiments in which SSTs and sea-ice boundary conditions are constrained by observations. For each model, the AMIP runs were extended through the end of 2017 from the official CMIP6 AMIP end period in 2014. Results show that the models do a good job at capturing the pattern of observed changes in TOA flux observed by CERES, but tend to underestimate the magnitude.

Norman G Loeb↗

Atlas of radiation budget measurements from satellites, 1962 - 1970

Radiation budget data measured at the top of the atmosphere by earth-orbiting satellites for various time periods in the years 1962 through 1970 are presented in the form of contoured maps which were derived from 5 seasonal and 25 monthly and semimonthly data sets. The data are values of planetary albedo, infrared radiant exitance, absorbed solar energy, net radiation balance. Documentation and contoured maps are included together with data tabulation at each 10 deg latitude and longitude. Additional data published by other authors are referenced.

Vonderhaar, T. H.↗

The annual variation in the global heat balance of the earth

An annual variation with a range of 31 W/sq m is found in the global net radiation balance of the earth. The net radiation flux values measured from satellites and the changes in total heat content computed from independent sets of atmospheric and oceanic data show annual variations which are consistent with each other in both phase and magnitude. The net energy gain and loss by the planet within a year is stored and released within the system primarily by the oceans.

Ellis, J. S.↗

Economic evaluation of a solar hot-water-system

Analysis shows economic benefits at six representative sites using actual data from Tempe, Arizona and San Diego, California installations. Model is two-tank cascade water heater with flat-plate collector array for single-family residences. Performances are forecast for Albuquerque, New Mexico; Fort Worth, Texas; Madison, Wisconsin; and Washington, D.C. Costs are compared to net energy savings using variables for each site's environmental conditions, loads, fuel costs, and other economic factors; uncertainty analysis is included.

Source record↗

Crawl space assisted heat pump

A variety of experiments and simulations, currently being designed or underway, to determine the feasibility of conditioning the source air of an air to air heat pump using stored ground heat or cool to produce higher seasonal COP's and net energy savings are discussed. The ground would condition ambient air as it is drawn through the crawl space of a house. Tests designed to evaluate the feasibility of the concept, to determine the amount of heat or cool available from the ground, to study the effect of the system on the heating and cooling loads of the house, to study possible mechanisms which could enhance heat flow through the ground, and to determine if diurnal temperature swings are necessary to achieve successful system performance are described.

Ternes, M. P.↗

Discrepancies between empirical and theoretical models of the flaring solar chromosphere and their possible resolution

Models of the solar chromosphere during flaring deduced theoretically or empirically are compared. Marked discrepancies are noted and various reasons are offered to explain their existence. A means is presented for testing theoretical heating models (electron heating) by analyzing the net energy loss rates in (observed) empirical atmospheres and inverting the flare energy equation to deduce the parameters of the supposed heating mechanism.

Emslie, G. A.↗

Thin film concentrator panel development

The development and testing of a rigid panel concept that utilizes a thin film reflective surface for application to a low-cost point-focusing solar concentrator is discussed. It is shown that a thin film reflective surface is acceptable for use on solar concentrators, including 1500 F applications. Additionally, it is shown that a formed steel sheet substrate is a good choice for concentrator panels. The panel has good optical properties, acceptable forming tolerances, environmentally resistant substrate and stiffeners, and adaptability to low to mass production rates. Computer simulations of the concentrator optics were run using the selected reflector panel design. Experimentally determined values for reflector surface specularity and reflectivity along with dimensional data were used in the analysis. The simulations provided intercept factor and net energy into the aperture as a function of aperture size for different surface errors and pointing errors. Point source and Sun source optical tests were also performed.

Zimmerman, D. K.↗

Quantum-chemical modeling of boron and noble gas dopants in silicon

The electron effects of the presence of boron and noble gas dopants in a model silicon lattice were investigated using a self-consistent charge extended Hueckel program. The extent of electronic interaction of the noble gas with the lattice is given by: Kr greater than Ar greater than Ne. Theoretically, boron diffusion in the presence of neon, argon or krypton was examined using a self-consistent charge extended Hueckel program. The net energy of interaction between boron and neon is strongly repulsive while argon-boron exhibits a region of relative stability; krypton exhibits behavior similar to argon though no region of stability was found for the range of separations used in the calculations. Finally, it is noted, from the relative energy of the topmost filled molecular orbital associated with boron (in an interstitial position), that activation of the boron does not require boron movement but can be accomplished by indirect transitions.

Aronowitz, S.↗

Effect of rotation on isotropic turbulence - Computation and modelling

This paper uses numerical simulation to analyse the effects of uniform rotation on homogeneous turbulence. Both large-eddy and full simulations were made. The results indicate that the predominant effect of rotation is to decrease the rate of dissipation of the turbulence and increase the lengthscales, especially those along the axis of rotation. These effects are a consequence of the reduction, due to the generation of inertial waves, of the net energy transfer from large eddies to small ones. Experiments are also influenced by a more complicated interaction between the rotation and the wakes of the turbulence-generating grid which modifies the nominal initial conditions in the experiment. The latter effect is accounted for in simulations by modifying the initial conditions. Finally, a two-equation model is proposed that accounts for the effects of rotation and is able to reproduce the experimental decay of the turbulent kinetic energy.

Bardina, J.↗

Overview of the new ASME Performance Test Code for wind turbines

The principal technical features of the ASME Performance Test Code for wind turbines are presented and such issues as what sizes and types of wind turbines should be included, what the principal measure of performance should be, and how wind speed should be measured are discussed. It is concluded that the present test code is applicable to wind turbine systems of all sizes. The principal measure of performance as defined by this code is net energy output and the primary performance parameter is the 'test energy ratio' which is based on a comparison between the measured and predicted energy output for the test period.

Spera, David A.↗

Photometric observations of the energetics of small solar active regions

The energetics of small solar active regions was investigated using for the analysis the photometric solar images taken from July 29 to September 6, 1984 with the San Fernando Observatory's 28-cm vacuum telescope, vacuum spectroheliograph, and dual 512 element Reticon linear diode arrays. Ten small newly formed regions were observed, whose entire sunspot evolution apparently occurred within the observed disk crossing. Seven of these showed a net energy excess of a few times 10 to the 33th ergs during this time. These results are discussed in connection with the 0.1 percent decline in solar irradiance observed by the SMM/ACRIM and Nimbus 7/ERB radiometers between 1980 and 1986.

Lawrence, J. K.↗

Atmospheric energetics and earth radiation budget

Processed ERBE data are used in several studies in which NMC global analyses and forecasts are examined and evaluated. In the first study, ERBE net radiation values for four months are averaged and integrated to provide global net energy transport. Energy transport by atmospheric circulations is obtained using NMC analyses and results provide a measure of reasonableness of the analyses. In the second and third experiments, ERBE values of outgoing longwave radiation are used as 'top-side truth' to examine both the spin-up problem and the radiation algorithms of the global forecasts.

Kann, Deirdre M.↗

Influence of eccentric actions on the metabolic cost of resistance exercise

The contributions of concentric (con) and eccentric (ecc) muscle actions are evaluated with respect to increasing the metabolic cost of resistance exercise. Male subjects perform leg exercise with either con and ecc actions or only con actions while the net energy cost of the exercise is measured by oxygen consumption data. In both groups, the con actions require 290 J/kg body weight of total work, with an energy cost of 0.003 cal/J. The energy costs for the con/ecc actions of the second group is increased by 14 percent. The metabolic cost of leg exercise is concluded to be primarily generated by the con leg actions, and ecc leg actions increase the resistance with only a slight increase in required energy. The findings are significant for practical applications that emphasize the conservation of energy expenditure during exercise in spacecraft environments.

Dudley, Gary A.↗

Metabolic rate measurements comparing supine with upright upper-body exercises

The ground-based study that tested the hypothesis that metabolic rates during supine and upright upper-body exercises are similar (mean value of 200 kcal/h) is presented. Six subjects each performed supine or upright exercise at three exercise stations, a hand-cycle ergometer, a rope-pull device, and a torque wrench. After a baseline measurement of the metabolic rate at rest, the metabolic rate was measured twice at each exercise station. The mean metabolic rates (kcal/h) during supine (n = 6) and upright control (n = 4) exercise stations were not significantly different except for the rope-pull station, 153.5 +/- 16.6 (supine) as compared to 247.0 +/- 21.7 (upright), p is less than 0.05. This difference may be due in part to an increased mechanical efficiency of supine exercises (15.0 +/- 0.7 percent) as compared to that of upright exercises (11.0 +/- 1.08 percent), p is less than 0.05. The net energy input was significantly smaller for the supine rope-pull exercise (64 +/- 18) as compared to upright (176 +/- 20). The relationship between best-rest exercises, metabolic rates, and the incidence of decompression sickness (DCS) should be examined to determine the true risk of DCS in spaceflight extravehicular activities.

Fortney, Suzanne M.↗

Iogenic Plasma and its Rotation-Driven Transport in Jupiter's Magnetosphere

Model calculations are reported for the Iogenic plasma source created by atomic oxygen and sulfur above Io's exobase in the corona and extended clouds (Outer Region). On a circumplanetary scale, two-dimensional distributions produced by integrating the proper three dimensional rate information for electron impact and charge exchange processes along the magnetic field lines are presented for the pickup ion rates, the net-mass and total-mass loading rates, the mass per unit magnetic flux rate, the pickup conductivity, the radial pickup current, and the net-energy loading rate for the plasma torus. All of the two-dimensional distributions are highly peaked at Io's location and hence highly asymmetric about Jupiter. The Iogenic plasma source is also calculated on a much smaller near-Io scale to investigate the structure of the highly peak rates centered about lo's instantaneous location. The Iogenic plasma source for the Inner Region (pickup rates produced below Io's exobase) is, however, expected to be the dominant source near lo for the formation of the plasma torus ribbon and to be a comparable source, if not a larger contributor, to the energy budget of the plasma torus, so as to provide the necessary power to sustain the plasma torus radiative loss rate.

Smyth, William H.↗

Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

Roychoudhury, S.↗

Fabrication and Testing of a Thin-Film Heat Flux Sensor for a Stirling Convertor

The NASA Glenn Research Center (GRC) has been testing high efficiency free-piston Stirling convertors for potential use in radioisotope power systems since 1999. Stirling convertors are being operated for many years to demonstrate a radioisotope power system capable of providing reliable power for potential multi-year missions. Techniques used to monitor the convertors for change in performance include measurements of temperature, pressure, energy addition, and energy rejection. Micro-porous bulk insulation is used in the Stirling convertor test set up to minimize the loss of thermal energy from the electric heat source to the environment. The insulation is characterized before extended operation, enabling correlation of the net thermal energy addition to the convertor. Aging microporous bulk insulation changes insulation efficiency, introducing errors in the correlation for net thermal energy addition. A thin-mm heat flux sensor was designed and fabricated to directly measure the net thermal energy addition to the Stirling convertor. The fabrication techniques include slip casting and using Physical Vapor Deposition (PVD). One micron thick noble metal thermocouples measure temperature on the surface of an Alumina ceramic disc and heat flux is calculated. Fabrication, integration, and test results of a thin film heat flux sensor are presented.

Wilson, Scott D.↗