NIMBUS ADVANCED VIDICON CAMERA SUBSYSTEM
Nimbus satellite - advanced vidicon camera subsystem - cloud pictures
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nimbus satellite - advanced vidicon camera subsystem - cloud pictures
Explore the source record for details and available documents.
A spatially variable monthly, infrared cloud-threshold data base has been used to screen cloud-contaminated observations from radiances measured by the NOAA-9 AVHRR over Africa. Cloud-screening through a monthly average infrared threshold based on measured surface air temperature, which is geographically dependent, shows an improvement over using a seasonally and geographically independent thermal cloud threshold of 287 K. It is found that differences in cloud-screening for these two thresholds occur for cases of lower altitude clouds or subpixel clouds where the radiative temperature is higher than the 287 K infrared threshold, yet colder than the variable threshold developed by Stowe et al. (1988) for the Nimbus-7 global cloud climatology. The variable IR threshold is shown to be effective over persistently cloud-covered regions, such as the coastal region of the Gulf of Guinea, but may introduce some erroneous cloud identifications over mountains.
The potential role of polar stratospheric clouds in atmospheric processes was assessed. The observations of polar stratospheric clouds with the Nimbus 7 SAM II satellite experiment were reviewed and a preliminary analysis of their formation, impact on other remote sensing experiments, and potential impact on climate were presented. The potential effect of polar stratospheric clouds on climate, radiation balance, atmospheric dynamics, stratospheric chemistry and water vapor budget, and cloud microphysics was assessed. Conclusions and recommendations, a synopsis of materials and complementary material to support those conclusions and recommendations are presented.
Estimates of clear and low, middle and high cloud amount in fixed geographical regions approximately (160 km) squared are being made routinely from 11.5 micron radiance measurements of the Nimbus-7 Temperature-Humidity Infrared Radiometer (THIR). The purpose of validation is to determine the accuracy of the THIR cloud estimates. Validation requires that a comparison be made between the THIR estimates of cloudiness and the 'true' cloudiness. The validation results reported in this paper use human analysis of concurrent but independent satellite images with surface meteorological and radiosonde observations to approximate the 'true' cloudiness. Regression and error analyses are used to estimate the systematic and random errors of THIR derived clear amount.
Data processing and error analysis of noise and systematic errors in high resolution infrared radiometer cloud cover data from Nimbus 2
The Nimbus-7 Earth Radiation Budget (ERB) instrument began recording data on November 16, 1978 and it is now in its 12th data year. The principle products are nine years of global albedo, outgoing longwave, and net radiation plus continuing solar irradiance measurements. The presence of an associated six-year Nimbus-7 global cloud data set enhances the usefulness of the ERB products. The chief purpose of this paper is to describe some uses that have been made of the data. These include studies in: regional energy heat budgets, the improvement of climate and weather prediction models, interannual climate variations, shortwave bidirectional reflectance from earth atmosphere scenes, and solar physics. The evolution of the data products with time and some algorithm and calibration problems are also briefly discussed. Despite numerous problems, the experiment continues to prove its usefulness.
An evaluation of the optical effects of stratospheric aerosol layers on total ozone retrieval from space by the TOMS/SBUV type instruments is presented here. Using the Dave radiative transfer model we estimate the magnitude of the errors in the retrieved ozone when polar stratospheric clouds (PSC's) or volcanic aerosol layers interfere with the measurements. The largest errors are produced by optically thick water ice PSC's. Results of simulation experiments on the effect of the Pinatubo aerosol cloud on the Nimbus-7 and Meteor-3 TOMS products are presented.
Passive microwave radiometers provide highly useful information regarding the Earth system by measuring thermal emission (from the surface and atmosphere) that is reflected, absorbed, and scattered by the surface and the atmosphere. As such, radiometers have been instrumental across Earth-observing concepts with heritage tracing back to the Nimbus era, and clouds and precipitation have been key geophysical phenomena these sensors have targeted. As millimeter-wave (particularly ≥85 GHz) and submillimeter-wave technologies have advanced, the applicability of microwave radiometers has expanded to encompass falling snow and ice clouds, respectively. Given the strong heritage of microwave radiometry and the emergence of submillimeter-wave sensors for sensing falling snow and ice clouds, the National Academies’ 2017 Decadal Survey for Earth Science and Applications from Space recommended passive sensors covering these wavelengths be included in observing systems that address the Aerosols, Clouds, Convection, and Precipitation (ACCP) combined designated observable. To showcase the capabilities for addressing the ACCP science objectives, we will provide an overview of the passive microwave capabilities envisioned for the Atmosphere Observing System (AOS, part of the recently unveiled NASA Earth System Observatory), including descriptions of the radiometers for the inclined and polar orbits and the primary geophysical variables of interest related to ice-phase clouds and precipitation. We will also discuss secondary science objectives, such as precipitation mapping, that can be achieved with the ACCP/AOS radiometers. Examples from the analyses performed for the ACCP/AOS architecture study and subsequent sensor definition exercises will be presented, outlining the basis for the radiometer configuration within the context of the overarching ACCP/AOS goals to elucidate the connections between atmospheric dynamics, weather (including extreme events), air quality, and climate.
The Pilot Climate Data System (PCDS) was found to be useful in examining a subset of data from the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS). The TOMS instrument scans with six channels between .3 and .4 micrometers. It was suggested that by analyzing albedo values from the longer wavelength channels of the TOMS, the effects of increasing optical depth could be determined. It is spectral relationship of albedo-to-optical depth that is investigated here. The question can be stated: Is there spectral differentiation in albedo with changes in the optical depth of clouds? Nimbus-7 TOMS data were obtained through the PCDS for an area and time period for which correlative NOAA AVHRR data were available. The AVHRR data were important in determining the existing cloud patterns. As expected, no spectral differentiation was observed at very high albedos (associated with high optical depths). However, at lower optical depths, evidence of spectral dependence on albedo was observed. Mapping the results geographically was deemed highly desirable but was not possible through the PCDS at the time. The PCDS can be viewed as an effective research tool to access selected portions of data. Without being intimately familiar with a data set, a PCDS user can successfully manipulate data in a scientific study.
A new technique denoted cloud slicing has been developed for estimating tropospheric ozone profile information. All previous methods using satellite data were only capable of estimating the total column of ozone in the troposphere. Cloud slicing takes advantage of the opaque property of water vapor clouds to ultraviolet wavelength radiation. Measurements of above-cloud column ozone from the Nimbus 7 total ozone mapping spectrometer (TOMS) instrument are combined together with Nimbus 7 temperature humidity and infrared radiometer (THIR) cloud-top pressure data to derive ozone column amounts in the upper troposphere. In this study tropical TOMS and THIR data for the period 1979-1984 are analyzed. By combining total tropospheric column ozone (denoted TCO) measurements from the convective cloud differential (CCD) method with 100-400 hPa upper tropospheric column ozone amounts from cloud slicing, it is possible to estimate 400-1000 hPa lower tropospheric column ozone and evaluate its spatial and temporal variability. Results for both the upper and lower tropical troposphere show a year-round zonal wavenumber 1 pattern in column ozone with largest amounts in the Atlantic region (up to approx. 15 DU in the 100-400 hPa pressure band and approx. 25-30 DU in the 400-1000 hPa pressure band). Upper tropospheric ozone derived from cloud slicing shows maximum column amounts in the Atlantic region in the June-August and September-November seasons which is similar to the seasonal variability of CCD derived TCO in the region. For the lower troposphere, largest column amounts occur in the September-November season over Brazil in South America and also southern Africa. Localized increases in the tropics in lower tropospheric ozone are found over the northern region of South America around August and off the west coast of equatorial Africa in the March-May season. Time series analysis for several regions in South America and Africa show an anomalous increase in ozone in the lower troposphere around the month of March which is not observed in the upper troposphere. The eastern Pacific indicates weak seasonal variability of upper, lower, and total tropospheric ozone compared to the western Pacific which shows largest TCO amounts in both hemispheres around spring months. Ozone variability in the western Pacific is expected to have greater variability caused by strong convection, pollution and biomass burning, land/sea contrast and monsoon developments.
A new technique denoted cloud slicing has been developed for measuring upper tropospheric ozone. Cloud slicing takes advantage of the opaque property of water vapor clouds to ultraviolet wavelength radiation. Measurements of above-cloud column ozone from the Nimbus 7 total ozone mapping spectrometer (TOMS) instrument are combined together with Nimbus 7 temperature humidity and infrared radiometer (THIR) cloud-top pressure data to derive ozone column amounts in the upper troposphere. In this study tropical TOMS and THIR data for the period 1979-1984 are analyzed. By combining total tropospheric column ozone (denoted TCO) measurements from the convective cloud differential (CCD) method with 100-400 hPa upper tropospheric column ozone amounts from cloud slicing, it is possible to estimate 400-1000 hPa lower tropospheric column ozone and evaluate its spatial and temporal variability. Results for both the upper and lower tropical troposphere show a year-round zonal wave number 1 pattern in column ozone with largest amounts in the Atlantic region (up to 15 DU in the 100-400 hPa pressure band and around 25-30 DU in the 400-1000 hPa pressure band). Upper tropospheric ozone derived from cloud slicing shows maximum column amounts in the Atlantic region in the June-August and September-November seasons which is similar to the seasonal variability of CCD derived TCO in the region. For the lower troposphere, largest column amounts occur in the September-November season over Brazil in South America and also southern Africa. Localized increases in the tropics in lower tropospheric ozone are found over the northern region of South America around August and off the west coast of equatorial Africa in the March-May season. Time series analysis for several regions in South America and Africa show an anomalous increase in ozone in the lower troposphere around the month of March which is not observed in the upper troposphere. The eastern Pacific indicates weak seasonal variability of upper, lower, and total tropospheric ozone compared to the western Pacific which shows largest TCO amounts in both hemispheres around spring months. Ozone variability in the western Pacific is expected to have greater variability caused by strong convection, pollution and biomass burning, land/sea contrast and monsoon developments.
A new technique called "cloud slicing" is introduced in this study to determine tropospheric ozone profile information. This method is unique because all previous methods incorporating satellite data were only capable of estimating the total column of ozone in the troposphere. Cloud slicing takes advantage of the opaque property of water vapor clouds to ultraviolet wavelength radiation. Measurements of above-cloud column ozone from the Nimbus 7 total ozone mapping spectrometer (TOMS) instrument are combined together with Nimbus 7 temperature humidity and infrared radiometer (THIR) cloud-top pressure data to derive ozone column amounts in the upper troposphere. In this study, tropical TOMS and THIR data for the period 1979-1984 are analyzed. Our investigation examines several case studies and illustrates the robust nature of this new technique for future satellite missions.
Infrared interferometric spectra obtained by Nimbus-4 instrumentation are analyzed for the spectral properties of cloud brightness temperatures as a function of wave number. It is shown that cloud-top altitude determination can be corrected for emissions from lower levels in the cloud if an estimate can be made of the particle density. Brightness temperature in the 700 to 950 wave number region can be used to estimate cloud number density.
Three different estimates of the percent of fixed geographical regions (160 x 160 km) either free of cloud (clear) or covered by low, middle, and high (opaque) cloud have been intercompared. The estimates were derived by analysts interpreting geosynchronous satellite images, with concurrent meteorological observations; from Nimbus 7 temperature humidity infrared radiometer (THIR) CLOUD ERB (CLE) data; and from Air Force three dimensional nephanalysis (3DN) data. Air Force 3DN agrees better with the analyst than THIR/CLE, except for high cloud amount; the CLE and 3DN results tend to overestimate clear amount when clear amount is large and underestimate it when clear amount is small, by 10-20 percent for CLE and by 5-10 percent for 3DN, and both agree well with the analyst in the mean. Systematic and random errors for 3DN and CLE are specified. CLE estimates of cloud amount over land at night should not be used for scientific purposes unless restricted to high cloud amount. It is believed that the CLR and 3DN are the only two digitized, global cloud type and amount data sets in existence.
Nimbus data-handling system for cloud pictures and infrared information
Cumulus cloud and fog bank spectral reflectance observations using Nimbus satellites and infrared radiometers
Nimbus II AVCS, APT, HRIR and MRIR sensory data analysis