Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOISE THRESHOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Planck 2013 results. XX. Cosmology from Sunyaev–Zeldovich cluster counts

We present constraints on cosmological parameters using number counts as a function of redshift for a sub-sample of 189 galaxy clusters from the Planck SZ (PSZ) catalogue. The PSZ is selected through the signature of the Sunyaev-Zeldovich (SZ) effect, and the sub-sample used here has a signal-to-noise threshold of seven, with each object confirmed as a cluster and all but one with a redshift estimate. We discuss the completeness of the sample and our construction of a likelihood analysis. Using a relation between mass M and SZ signal Y calibrated to X-ray measurements, we derive constraints on the power spectrum amplitude σ8 and matter density parameter Ω m in a flat ΛCDM model. We test the robustness of our estimates and find that possible biases in the Y–M relation and the halo mass function are larger than the statistical uncertainties from the cluster sample. Assuming the X-ray determined mass to be biased low relative to the true mass by between zero and 30%, motivated by comparison of the observed mass scaling relations to those from a set of numerical simulations, we find that σ 8 = 0.75 ± 0.03, Ω m = 0.29 ± 0.02, and σ 8 (Ω m /0.27) 0.3 = 0.764 ± 0.025. The value of σ 8 is degenerate with the mass bias; if the latter is fixed to a value of 20% (the central value from numerical simulations) we find σ 8 (Ω m /0.27) 0.3 = 0.78 ± 0.01 and a tighter one-dimensional range σ 8 = 0.77 ± 0.02. We find that the larger values of σ 8 and Ω m preferred by Planck's measurements of the primary CMB anisotropies can be accommodated by a mass bias of about 40%. Alternatively, consistency with the primary CMB constraints can be achieved by inclusion of processes that suppress power on small scales relative to the ΛCDM model, such as a component of massive neutrinos. We place our results in the context of other determinations of cosmological parameters, and discuss issues that need to be resolved in order to make further progress in this field.

79 ASTRONOMY AND ASTROPHYSICS↗

On a framework for generating PoD curves assisted by numerical simulations

The Probability of Detection (PoD) curve method has emerged as an important tool for the assessment of the performance of NDE techniques, a topic of particular interest to the nuclear industry where inspection qualification is very important. The conventional experimental means of generating PoD curves though, can be expensive, requiring large data sets (covering defects and test conditions), and equipment and operator time. Several methods of achieving faster estimates for PoD curves using physics-based modelling have been developed to address this problem. Numerical modelling techniques are also attractive, especially given the ever-increasing computational power available to scientists today. Here we develop procedures for obtaining PoD curves, assisted by numerical simulation and based on Bayesian statistics. Numerical simulations are performed using Finite Element analysis for factors that are assumed to be independent, random and normally distributed. PoD curves so generated are compared with experiments on austenitic stainless steel (SS) plates with artificially created notches. We examine issues affecting the PoD curve generation process including codes, standards, distribution of defect parameters and the choice of the noise threshold. We also study the assumption of normal distribution for signal response parameters and consider strategies for dealing with data that may be more complex or sparse to justify this. These topics are addressed and illustrated through the example case of generation of PoD curves for pulse-echo ultrasonic inspection of vertical surface-breaking cracks in SS plates.

36 MATERIALS SCIENCE↗

Fault-Tolerant Operation of Bosonic Qubits with Discrete-Variable Ancillae

Fault-tolerant quantum computation with bosonic qubits often necessitates the use of noisy discrete-variable ancillae. In this work, we establish a comprehensive and practical fault-tolerance framework for such a hybrid system and synthesize it with fault-tolerant protocols by combining bosonic quantum error correction (QEC) and advanced quantum control techniques. We introduce essential building blocks of error-corrected gadgets by leveraging ancilla-assisted bosonic operations using a generalized variant of path-independent quantum control. Using these building blocks, we construct a universal set of error-corrected gadgets that tolerate a single-photon loss and an arbitrary ancilla fault for four-legged cat qubits. Notably, our construction requires only dispersive coupling between bosonic modes and ancillae, as well as beam-splitter coupling between bosonic modes, both of which have been experimentally demonstrated with strong strengths and high accuracy. Moreover, each error-corrected bosonic qubit is comprised of only a single bosonic mode and a three-level ancilla, featuring the hardware efficiency of bosonic QEC in the full fault-tolerant setting. We numerically demonstrate the feasibility of our schemes using current experimental parameters in the circuit-QED platform. Finally, we present a hardware-efficient architecture for fault-tolerant quantum computing by concatenating the four-legged cat qubits with an outer qubit code utilizing only beam-splitter couplings. Our estimates suggest that the overall noise threshold can be reached using existing hardware. These developed fault-tolerant schemes extend beyond their applicability to four-legged cat qubits and can be adapted for other rotation-symmetrical codes, offering a promising avenue toward scalable and robust quantum computation with bosonic qubits. Published by the American Physical Society 2024

Physics↗

Calibration of coronary calcium scores determined using iterative image reconstruction (AIDR 3D) at 120, 100, and 80 kVp

Purpose: Computed tomography (CT) radiation dose reduction is frequently achieved by applying lower tube voltages and using iterative reconstruction (IR). For calcium scoring, the reference protocol at 120 kVp with filtered back projection (FBP) is still used, because kVp and IR may influence the Agatston score (AS) and volume score (VS). The authors present a two-step method to optimize dose: first, to determine the lowest feasible exposure and highest noise thresholds; second, to define a calibration method that ensures that the AS and VS are similar to the reference protocol. Methods: AS and VS were measured for an anthropomorphic thoracic phantom that includes a calcium calibration module. The phantom was scanned on a 320-row CT scanner, at tube voltages of 120 kVp using FBP, and 120, 100, and 80 kVp using adaptive iterative dose reduction (AIDR 3D) reconstruction. The minimum CTDIs were determined based on three objective quality criteria. Calibration was performed to estimate adjusted CT number thresholds for the lower kVp acquisitions. Finally, the accuracies of the total and individual insert scores at dose level close to the minimum CTDI level were investigated and compared to low (FBP{sub LD} − 120) and high (FBP{sub HD} − 120) dose reference protocols (based on ten repeated acquisitions for each group). Results: IR allows the exposure to be reduced by 69% at 120 kVp, with no significant effect on the total scores when averaged over all included dose steps and compared to FBP-120 (AS: 693 vs 699, p = 0.182; VS: 588 vs 587 mm{sup 3}, p = 0.569). Also when averaged over ten repeated scans and compared to FBP{sub HD} − 120 (AS: 709 vs 704, p = 0.435; VS: 604 vs 601 mm{sup 3}, p = 0.479), there is no statistical significant effect. Reducing the peak tube voltage allows even greater dose reductions: 73% at 100 kVp and 76% at 80 kVp. The calibrated CT number thresholds for analysis at 120, 100, and 80 kVp were, respectively, 130, 133, and 160 HU for the Agatston score, and 130, 132, and 140 HU for the volume score. Following the calibration, the mean scores of the four groups with dose variation were not significantly different from the reference protocol, at 100 kVp (AS: 698 vs 699, p = 0.818; VS: 584 vs 587 mm{sup 3}, p = 0.365) or at 80 kVp (AS: 698 vs 699, p = 0.996; VS: 586 vs 587 mm{sup 3}, p = 0.827). Similarly, there was no significant score difference with FBP{sub LD} − 120 during repeated scanning: 100 kVp (AS: 690 vs 694, p = 0.394; VS: 579 vs 585 mm{sup 3}, p = 0.168) and 80 kVp (AS: 703 vs 694, p = 0.115; VS: 588 vs 585 mm{sup 3}, p = 0.613). Compared to FBP{sub HD} − 120 group, the relative score deviation for the accuracy of the 400 and 800 mg/cm{sup 3} HA inserts with 3 and 5 mm diameter is less than 7%. However, the relative deviation of the smaller 1 mm inserts is poorer (up to 41% deviations for scores <3). Conclusions: With iterative reconstruction using AIDR 3D, deviations of the total Agatston and volume scores remain within 4% of the reference protocol. The 1 mm inserts were detected as calcification, but scores less than ten tend to be underestimated. Following the calibration process, the application of IR in combination with reduced tube voltages allows up to 76% lower radiation dose.

60 APPLIED LIFE SCIENCES↗

High level tritiated water monitoring by Bremsstrahlung counting using a silicon drift detector

The β-ray induced X-ray spectrometry (BIXS) is a promising technique to monitor the tritium concentration in a fuel cycle of a fusion reactor. For in-situ measurements of high level tritiated water by Bremsstrahlung counting, the characteristics of a low-noise silicon drift detector (SDD) have been examined at the Tritium Laboratory Karlsruhe (TLK). In static measurements with constant sample volume and tritium concentration, the Bremsstrahlung spectra of tritiated water samples in a concentration range of 0.02 to 15 MBq/ml have been obtained. The volume has been kept constant at 5 cm{sup 3}. The observed spectra are well above the noise threshold. In addition to X-rays induced by β-rays, the spectra feature X-ray fluorescence peaks of the surrounding materials. No indications of memory effects have been observed. A linear relation between the X-ray intensity and the tritium concentration was obtained and the lower detection limit of the setup has been determined to 1 MBq ml{sup -1}, assessed by the Curie criterion. In addition, the spectra obtained experimentally could be reproduced with high agreement by Monte-Carlo simulations using the GEANT4-tool-kit. It was found that the present detection system is applicable to non-invasive measurements of high-level tritiated water and the SDD is a convenient tool to detect the low energy Bremsstrahlung X-rays. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bio-Inspired Energy-Efficient Nanofabricated Electrical Contacts

Nanoscale electrical contacts, especially those between materials of dissimilar electronic properties, often represent one of the main causes of drops in energy transfer efficiency. They are also among the sources of above-threshold noise, and their performance often decreases over the lifetime of the nanodevices. Scale-down limitations from mesoscopic to nanoscale devices, and likewise, of nanoscale to quantum-scale devices are also impeded by contacts’ quality. Making more reliable, energy-efficient electrical contacts is among the goals of the nanoelectronics research within the framework of energy-efficient electronic systems. This report focuses on the design, nanofabrication, and testing of novel shapes of electrical contacts. Lithography and nanofabrication were utilized to mimic the approximate shape of insect setae for mesoscale contacts design. The contacts are tested for elementary charge transport via I–V curves and for the broadband, 1/f noise. Tests show that contacts design leads to a measurable decrease in the energy necessary to operate a contact as a switch by at least 12–20%, depending on temperature, while broadband noise shows measurably lower power spectra, for bio-inspired contacts. The proposed method is open to modifications and improvements as required by various on-chip applications.

36 MATERIALS SCIENCE↗

Searching for Interstellar Quantum Communications

The modern search for extraterrestrial intelligence began with the seminal publications of Cocconi & Morrison and Schwartz & Townes, who proposed searching for narrowband signals in the radio spectrum and optical laser pulses. Over the last six decades, more than 100 dedicated search programs have targeted these wavelengths, all with null results. All of these campaigns searched for classical communications, that is, for a significant number of photons above a noise threshold, with the assumption of a pattern encoded in time and/or frequency space. I argue that future searches should also target quantum communications. They are preferred over classical communications with regard to security and information efficiency, and they would have escaped detection in all previous searches. The measurement of Fock state photons or squeezed light would indicate the artificiality of a signal. I show that quantum coherence is feasible over interstellar distances and explain for the first time how astronomers can search for quantum transmissions sent by ETI to Earth using commercially available telescopes and receiver equipment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equation of State Dependent Dynamics and Multi-messenger Signals from Stellar-mass Black Hole Formation

We investigate axisymmetric black hole (BH) formation and its gravitational wave (GW) and neutrino signals with self-consistent core-collapse supernova simulations of a non-rotating 40 M ⊙ progenitor star using the isotropic diffusion source approximation for the neutrino transport and a modified gravitational potential for general relativistic effects. We consider four different neutron star (NS) equations of state (EoS): LS220, SFHo, BHBΛ$\phi$, and DD2, and study the impact of the EoS on BH formation dynamics and GW emission. We find that the BH formation time is sensitive to the EoS from 460 to >1300 ms and is delayed in multiple dimensions for ~100–250 ms due to the finite entropy effects. Depending on the EoS, our simulations show the possibility that shock revival can occur along with the collapse of the proto-neutron star (PNS) to a BH. The gravitational waveforms contain four major features that are similar to previous studies but show extreme values: (1) a low-frequency signal (~300–500 Hz) from core-bounce and prompt convection, (2) a strong signal from the PNS g-mode oscillation among other features, (3) a high-frequency signal from the PNS inner-core convection, and (4) signals from the standing accretion shock instability and convection. The peak frequency at the onset of BH formation reaches to ~2.3 kHz. Thus, the characteristic amplitude of a 10 kpc object at peak frequency is detectable but close to the noise threshold of the Advanced LIGO and KAGRA, suggesting that the next-generation GW detector will need to improve the sensitivity at the kHz domain to better observe stellar-mass BH formation from core-collapse supernovae or failed supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

The Cosmic Evolution of C IV Absorbers at 1.4 < z < 4.5: Insights from 100,000 Systems in DESI Quasars

We present the largest catalog to date of triply ionized carbon (C IV ) absorbers detected in quasar spectra from the Dark Energy Spectroscopic Instrument. Using an automated matched-kernel convolution method with adaptive signal-to-noise thresholds, we identify 101,487 C IV systems in the redshift range 1.4 < z < 4.5 from 300,637 quasar spectra. Completeness is estimated via Monte Carlo simulations, and the catalog is 50% complete at EW C IV ≥ 0.4 Å. The differential equivalent width frequency distribution declines exponentially and shows weak redshift evolution. The absorber incidence per unit comoving path increases by a factor of 2–5 from z ≈ 4.5 to z ≈ 1.4, with stronger redshift evolution for strong systems. Using column densities derived from the apparent optical depth method, we constrain the cosmic mass density of C IV , Ω C IV , which increases by a factor of ∼3.8 from (0.82 ± 0.05) × 10 −8 at z ≈ 4.5 to (3.16 ± 0.2) × 10 −8 at z ≈ 1.4. From Ω C IV , we estimate a lower limit on intergalactic medium metallicity ${\mathrm{log}}({Z}_{{\rm{IGM}}}/{Z}_{\odot })\gtrsim -3.25$ at z ∼ 2.3, with a smooth decline at higher redshifts. These trends trace the cosmic star formation history and He II photoheating rate, suggesting a link between C IV enrichment, star formation, and UV background over ∼3 Gyr. The catalog also provides a critical resource for future studies connecting circumgalactic metals to galaxy evolution, especially near cosmic noon.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Strapdown Ring Laser Gyro Tetrad Inertial Navigation System in a helicopter flight environment

Results are presented for the first flight demonstration test of a strapdown laser inertial navigation system in a helicopter environment. It is noted that acceptable navigation accuracies were obtained with system alignment times as short as 5 min or less, and that the use of all four available sensors in the navigation algorithm did not significantly improve performance over that achievable by means of only three orthogonal sensors. Failure detection by means of the parity residual from four axes proved successful for failure levels far below the noise threshold of flight control sensing requirements. Summing the gyro parity residual for a period of 13-20 min can yield step-shifted laser gyro sensor bias error detection comparable to the gyro random shift specification.

Carestia, R. A.↗

High resolution, low energy avalanche photodiode X-ray detectors

Silicon avalanche photodiodes have been fabricated, and their performance as X-ray detectors has been measured. Photon sensitivity and energy resolution were measured as a function of size and operating parameters. Noise thresholds as low as 212 eV were obtained at room temperature, and backscatter X-ray fluorescence data were obtained for aluminum and other light elements. It is concluded that the results with the X-ray detector are extremely encouraging, and the performance is challenging the best available proportional counters. While not at the performance level of either cryogenic silicon or HgI2, these device operate at room temperature and can be reproduced in large numbers and with much larger areas than typically achieved with HgI2. In addition, they are rugged and appear to be indefinitely stable.

Farrell, R.↗

Estimation of frequency offset in mobile satellite modems

In mobilesat applications, frequency offset on the received signal must be estimated and removed prior to further modem processing. A straightforward method of estimating the carrier frequency offset is to raise the received MPSK signal to the M-th power, and then estimate the location of the peak spectral component. An analysis of the lower signal to noise threshold of this method is carried out for BPSK signals. Predicted thresholds are compared to simulation results. It is shown how the method can be extended to pi/M MPSK signals. A real-time implementation of frequency offset estimation for the Australian mobile satellite system is described.

Cowley, W. G.↗

Performance Evaluation of the SPT-140

As part of an on-going cooperative program with industry, an engineering model SPT-140 Hall thruster, which may be suitable for orbit insertion and station-keeping of geosynchronous communication satellites, was evaluated with respect to thrust and radiated electromagnetic interference at the NASA Lewis Research Center. Performance measurements were made using a laboratory model propellant feed system and commercial power supplies. The engine was operated in a space simulation chamber capable of providing background pressures of 4 x 10(exp -6) Torr or less during thruster operation. Thrust was measured at input powers ranging from 1.5 to 5 kilowatts with two different output filter configurations. The broadband electromagnetic emission spectra generated by the engine was also measured for a range of frequencies from 0.01 to 18,000 Mhz. These results are compared to the noise threshold of the measurement system and MIL-STD-461C where appropriate.

Manzella, David↗

Growth of Bulk Wide Bandgap Semiconductor Crystals and Their Potential Applications

Developments in bulk crystal growth research for electro-optical devices in the Center for Photonic Materials and Devices since its establishment have been reviewed. Purification processes and single crystal growth systems employing physical vapor transport and Bridgman methods were assembled and used to produce high purity and superior quality wide bandgap materials such as heavy metal halides and II-VI compound semiconductors. Comprehensive material characterization techniques have been employed to reveal the optical, electrical and thermodynamic properties of crystals, and the results were used to establish improved material processing procedures. Postgrowth treatments such as passivation, oxidation, chemical etching and metal contacting during the X-ray and gamma-ray device fabrication process have also been investigated and low noise threshold with improved energy resolution has been achieved.

Chen, Kuo-Tong↗