Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOMOGRAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Prognostic importance of the preoperative New‐Naples prognostic score for patients with gastric cancer

Abstract Background The wide applicability of the Naples prognostic score (NPS) is still worthy of further study in gastric cancer (GC). This study aimed to construct a New‐NPS based on the differences in immunity and nutrition in patients with upper and lower gastrointestinal tumors to help obtain an individualized prediction of prognosis. Methods This study retrospectively analyzed patients who underwent radical gastrectomy from April 2014 to September 2016. The cutoff values of the preoperative neutrophil‐to‐lymphocyte ratio (NLR), lymphocyte‐to‐monocyte ratio (LMR), serum albumin (Alb), and total cholesterol (TC) were calculated by ROC curve analysis. ROC and t‐ROC were used to evaluate the accuracy of the prognostic markers. The Kaplan–Meier method and log‐rank test were used to analyze the overall survival probability. Univariate and multivariate analyses based on Cox risk regression were used to show the independent predictors. The nomogram was made by R studio. The predictive accuracy of nomogram was assessed using a calibration plot, concordance index (C‐index), and decision curve. Results A total of 737 patients were included in training cohort, 411 patients were included in validation cohort. ROC showed that the New‐NPS was more suitable for predicting the prognosis of GC patients. NPS = 2 indicated a poor prognosis. Multivariate analysis showed that CEA ( P = 0.026), Borrmann type ( P = 0.001), pTNM ( P < 0.001), New‐NPS ( P < 0.001), and nerve infiltration ( P = 0.035) were independent risk factors for prognosis. Conclusion The New‐NPS based on the cutoff values of NLR, LMR, Alb, and TC is not only suitable for predicting prognosis but can also be combined with clinicopathological characteristics to construct a nomogram model for GC patients.

Wang, Hao↗

Differentiation of hepatic abscess from metastasis on contrast-enhanced dynamic computed tomography in patients with a history of extrahepatic malignancy: emphasis on dynamic change of arterial rim enhancement

Objectives: The objective of the study is to identify computed tomography (CT) findings that differentiate hepatic abscess from hepatic metastasis in a patient with a history of extrahepatic malignancy. Materials and methods: This retrospective study included 30 patients with 93 hepatic abscesses and 40 patients with 125 hepatic metastases who had a history of extrahepatic malignancy and underwent contrast-enhanced dynamic CT with arterial phase (AP) and portal venous phase (PVP). The diagnosis of hepatic abscess and hepatic metastasis was made using pathological confirmation or clinical diagnosis. Margin, patchy parenchymal enhancement, arterial rim enhancement, dynamic change of arterial rim enhancement, size discrepancy of lesions between arterial and portal phases, bile duct dilatation, perilesional hyperemia, and perilesional low density were evaluated by two radiologists independently. Significant findings for differentiating two groups were identified at univariate and multivariate analysis with nomogram for predicting hepatic abscess. Interobserver agreement was also analyzed for each variable. Results: Multivariate analysis revealed that patchy parenchymal enhancement (P < 0.001), arterial rim enhancement persistent through PVP (P < 0.001), and perilesional hyperemia (P = 0.013) were independent significant findings to predict hepatic abscess than metastasis. Among them, arterial rim enhancement persistent through PVP showed a highest odds ratio (OR 33.73) on multivariate analysis and a highest predictor point on a nomogram for predicting hepatic abscess. When two of these three criteria were combined, 80.7% (75/93) of hepatic abscess were correctly identified, with a specificity of 85.6% (107/125). When all three criteria were satisfied, specificity was up to 100% (125/125). Conclusions: At contrast-enhanced dynamic CT, patchy parenchymal enhancement, arterial rim enhancement persistent through PVP, perilesional hyperemia, and their combinations may be reliable CT features for differentiating hepatic abscess from metastasis in patients with a history of primary extrahepatic malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Validated Prediction Model for Overall Survival From Stage III Non-Small Cell Lung Cancer: Toward Survival Prediction for Individual Patients

Purpose: Although patients with stage III non-small cell lung cancer (NSCLC) are homogeneous according to the TNM staging system, they form a heterogeneous group, which is reflected in the survival outcome. The increasing amount of information for an individual patient and the growing number of treatment options facilitate personalized treatment, but they also complicate treatment decision making. Decision support systems (DSS), which provide individualized prognostic information, can overcome this but are currently lacking. A DSS for stage III NSCLC requires the development and integration of multiple models. The current study takes the first step in this process by developing and validating a model that can provide physicians with a survival probability for an individual NSCLC patient. Methods and Materials: Data from 548 patients with stage III NSCLC were available to enable the development of a prediction model, using stratified Cox regression. Variables were selected by using a bootstrap procedure. Performance of the model was expressed as the c statistic, assessed internally and on 2 external data sets (n=174 and n=130). Results: The final multivariate model, stratified for treatment, consisted of age, gender, World Health Organization performance status, overall treatment time, equivalent radiation dose, number of positive lymph node stations, and gross tumor volume. The bootstrapped c statistic was 0.62. The model could identify risk groups in external data sets. Nomograms were constructed to predict an individual patient's survival probability ( (www.predictcancer.org)). The data set can be downloaded at (https://www.cancerdata.org/10.1016/j.ijrobp.2015.02.048). Conclusions: The prediction model for overall survival of patients with stage III NSCLC highlights the importance of combining patient, clinical, and treatment variables. Nomograms were developed and validated. This tool could be used as a first building block for a decision support system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization of round HDR {sup 192}Ir AccuBoost applicators for breast brachytherapy

Purpose: The AccuBoost brachytherapy system applies HDR {sup 192}Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR {sup 192}Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. Methods: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. Results: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. Conclusions: Monte Carlo benchmarking simulations of the HDR {sup 192}Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients where preplan TRUS may be technically challenging.

60 APPLIED LIFE SCIENCES↗

SU-F-T-60: A Quick Dose Calculation Check for Accuboost Breast Treatment

Purpose: Accuboost treatment planning uses dwell times from a nomogram designed with Monte Carlo calculations for round and D-shaped applicators. A quick dose calculation method has been developed for verification of the HDR Brachytherapy dose as a second check. Methods: Accuboost breast treatment uses several round and D-shaped applicators to be used non-invasively with an Ir-192 source from a HDR Brachytherapy afterloader after the breast is compressed in a mammographic unit for localization. The breast thickness, source activity, the prescription dose and the applicator size are entered into a nomogram spreadsheet which gives the dwell times to be manually entered into the delivery computer. Approximating the HDR Ir-192 as a point source, and knowing the geometry of the round and D-applicators, the distances from the source positions to the midpoint of the central plane are calculated. Using the exposure constant of Ir-192 and medium as human tissue, the dose at a point is calculated as: D(cGy) = 1.254 × A × t/R2, where A is the activity in Ci, t is the dwell time in sec and R is the distance in cm. The dose from each dwell position is added to get the total dose. Results: Each fraction is delivered in two compressions: cranio-caudally and medial-laterally. A typical APBI treatment in 10 fractions requires 20 compressions. For a patient treated with D45 applicators and an average of 5.22 cm thickness, this calculation was 1.63 % higher than the prescription. For another patient using D53 applicators in the CC direction and 7 cm SDO applicators in the ML direction, this calculation was 1.31 % lower than the prescription. Conclusion: This is a simple and quick method to double check the dose on the central plane for Accuboost treatment.

60 APPLIED LIFE SCIENCES↗

Development and Verification of MATLAB Functions for Pressure Drop Estimation in Crossflow Tube Bundles

The experimental data on drag coefficients in crossflow tube bundles is severely limited. It is largely contained in nomograms for a small range of tube bundle pitch ratios for both in-line and staggered bundles. These monograms and the corresponding correlations/curve fits are not readily accessible. This lack of experimental data presents a limitation when designing crossflow heat exchangers for nuclear reactors. Specifically, Molten Salt Reactors (MSRs) that utilize cross-flow configurations with turbulent molten salts flowing in the shell side are of interest. Current methods of calculating the drag coefficients are outdated and time consuming when conducting design studies (i.e. picking points off a graph). A computer script could easily run the necessary rapid calculations of the pressure drop for a large possible range of Reynolds numbers, pitch ratios and tube bundle configurations. In an effort to facilitate increased access and accuracy to crossflow pressure drop calculations, a set of MATLAB scripts have been created. These are specifically for the pressure drop and drag coefficients for flow over rows of in-line and staggered tube bundles. For verification of the scripts, the nomograms produced by Zukauskas, of which the scripts are built off, served as a comparison to the plot generated by the MATLAB scripts. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Factors Associated With Early Mortality in Patients Treated With Concurrent Chemoradiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

Purpose: Concurrent chemoradiation therapy (con-CRT) is recommended for fit patients with locally advanced non-small cell lung cancer (LA-NSCLC) but is associated with toxicity, and observed survival continues to be limited. Identifying factors associated with early mortality could improve patient selection and identify strategies to improve prognosis. Methods and Materials: Analysis of a multi-institutional LA-NSCLC database consisting of 1245 patients treated with con-CRT in 13 institutions was performed to identify factors predictive of 180-day survival. Recursive partitioning analysis (RPA) was performed to identify prognostic groups for 180-day survival. Multivariate logistic regression analysis was used to create a clinical nomogram predicting 180-day survival based on important predictors from RPA. Results: Median follow-up was 43.5 months (95% confidence interval [CI]: 40.3-48.8) and 127 patients (10%) died within 180 days of treatment. Median, 180-day, and 1- to 5-year (by yearly increments) actuarial survival rates were 20.9 months, 90%, 71%, 45%, 32%, 27%, and 22% respectively. Multivariate analysis adjusted by region identified gross tumor volume (GTV) (odds ratio [OR] ≥100 cm{sup 3}: 2.61; 95% CI: 1.10-6.20; P=.029) and pulmonary function (forced expiratory volume in 1 second [FEV{sub 1}], defined as the ratio of FEV{sub 1} to forced vital capacity [FVC]) (OR <80%: 2.53; 95% CI: 1.09-5.88; P=.030) as significant predictors of 180-day survival. RPA resulted in a 2-class risk stratification system: low-risk (GTV <100 cm{sup 3} or GTV ≥100 cm{sup 3} and FEV{sub 1} ≥80%) and high-risk (GTV ≥100 cm{sup 3} and FEV{sub 1} <80%). The 180-day survival rates were 93% for low risk and 79% for high risk, with an OR of 4.43 (95% CI: 2.07-9.51; P<.001), adjusted by region. A clinical nomogram predictive of 180-day survival, incorporating FEV{sub 1}, GTV, N stage, and maximum esophagus dose yielded favorable calibration (R{sup 2} = 0.947). Conclusions: This analysis identified several risk factors associated with early mortality and suggests that future research in the optimization of pretreatment pulmonary function and/or functional lung avoidance treatment may alter the therapeutic ratio in this patient population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wide Area Security Region Final Report

This report develops innovative and efficient methodologies and practical procedures to determine the wide-area security region of a power system, which take into consideration all types of system constraints including thermal, voltage, voltage stability, transient and potentially oscillatory stability limits in the system. The approach expands the idea of transmission system nomograms to a multidimensional case, involving multiple system limits and parameters such as transmission path constraints, zonal generation or load, etc., considered concurrently. The security region boundary is represented using its piecewise approximation with the help of linear inequalities (so called hyperplanes) in a multi-dimensional space, consisting of system parameters that are critical for security analyses. The goal of this approximation is to find a minimum set of hyperplanes that describe the boundary with a given accuracy. Methodologies are also developed to use the security hyperplanes, pre-calculated offline, to determine system security margins in real-time system operations, to identify weak elements in the system, and to calculate key contributing factors and sensitivities to determine the best system controls in real time and to assist in developing remedial actions and transmission system enhancements offline . A prototype program that automates the simulation procedures used to build the set of security hyperplanes has also been developed. The program makes it convenient to update the set of security hyperplanes necessitated by changes in system configurations. A prototype operational tool that uses the security hyperplanes to assess security margins and to calculate optimal control directions in real time has been built to demonstrate the project success. Numerical simulations have been conducted using the full-size Western Electricity Coordinating Council (WECC) system model, and they clearly demonstrated the feasibility and the effectiveness of the developed technology. Recommendations for the future work have also been formulated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Late Fecal Incontinence After High-Dose Radiotherapy for Prostate Cancer: Better Prediction Using Longitudinal Definitions

Purpose: To model late fecal incontinence after high-dose prostate cancer radiotherapy (RT) in patients accrued in the AIROPROS (prostate working group of the Italian Association of Radiation Oncology) 0102 trial using different endpoint definitions. Methods and Materials: The self-reported questionnaires (before RT, 1 month after RT, and every 6 months for {<=}3 years after RT) of 586 patients were available. The peak incontinence (P{sub I}NC) and two longitudinal definitions (chronic incontinence [C{sub I}NC], defined as the persistence of Grade 1 or greater incontinence after any Grade 2-3 event; and mean incontinence score [M{sub I}NC], defined as the average score during the 3-year period after RT) were considered. The correlation between the clinical/dosimetric parameters (including rectal dose-volume histograms) and P{sub I}NC (Grade 2 or greater), C{sub I}NC, and M{sub I}NC of {>=}1 were investigated using multivariate logistic analyses. Receiver operating characteristic curves and the area under the curve were used to assess the predictive value of the different multivariate models. Results: Of the 586 patients, 36 with a Grade 1 or greater incontinence score before RT were not included in the present analysis. Of the 550 included patients, 197 (35.8%) had at least one control with a Grade 1 or greater incontinence score (M{sub I}NC >0). Of these 197 patients, 37 (6.7%), 22 (4.0%), and 17 (3.1%) were scored as having P{sub I}NC, M{sub I}NC {>=}1, and C{sub I}NC, respectively. On multivariate analysis, Grade 2 or greater acute incontinence was the only predictor of P{sub I}NC (odds ratio [OR], 5.9; p = .0009). Grade 3 acute incontinence was predictive of C{sub I}NC (OR, 9.4; p = .02), and percentage of the rectal volume receiving >40 Gy of {>=}80% was predictive of a M{sub I}NC of {>=}1 (OR, 3.8; p = .008) and of C{sub I}NC (OR, 3.6; p = .03). Previous bowel disease, previous abdominal/pelvic surgery, and the use of antihypertensive (protective factor) correlated highly with both C{sub I}NC and M{sub I}NC {>=}1. The predictive values of the models for C{sub I}NC (area under the curve, 0.83) and M{sub I}NC {>=}1 (area under the curve, 0.73) were greater than the ones for P{sub I}NC (area under the curve, 0.62) and more reliable (p = .0001-.0003 against p = .02). Nomograms for the two longitudinal definitions were derived. Conclusions: The longitudinal definitions of fecal incontinence (C{sub I}NC and M{sub I}NC {>=}1) were helpful in accounting for both the persistence and the severity of the incontinence. A significant fraction of peak events was consequential to acute incontinence, and a longer duration of symptoms mainly depended on the rectal dose bath (percentage of rectal volume receiving >40 Gy), and pretreatment clinical factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plaque Brachytherapy for Uveal Melanoma: A Vision Prognostication Model

Purpose: To generate a vision prognostication model after plaque brachytherapy for uveal melanoma. Methods and Materials: All patients with primary single ciliary body or choroidal melanoma treated with iodine-125 or ruthenium-106 plaque brachytherapy between January 1, 2005, and June 30, 2010, were included. The primary endpoint was loss of visual acuity. Only patients with initial visual acuity better than or equal to 20/50 were used to evaluate visual acuity worse than 20/50 at the end of the study, and only patients with initial visual acuity better than or equal to 20/200 were used to evaluate visual acuity worse than 20/200 at the end of the study. Factors analyzed were sex, age, cataracts, diabetes, tumor size (basal dimension and apical height), tumor location, and radiation dose to the tumor apex, fovea, and optic disc. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log rank analysis) were used to estimate freedom from vision loss. Results: Of 189 patients, 92% (174) were alive as of February 1, 2011. At presentation, visual acuity was better than or equal to 20/50 and better than or equal to 20/200 in 108 and 173 patients, respectively. Of these patients, 44.4% (48) had post-treatment visual acuity of worse than 20/50 and 25.4% (44) had post-treatment visual acuity worse than 20/200. By multivariable analysis, increased age (hazard ratio [HR] of 1.01 [1.00-1.03], P=.05), increase in tumor height (HR of 1.35 [1.22-1.48], P<.001), and a greater total dose to the fovea (HR of 1.01 [1.00-1.01], P<.001) were predictive of vision loss. This information was used to develop a nomogram predictive of vision loss. Conclusions: By providing a means to predict vision loss at 3 years after treatment, our vision prognostication model can be an important tool for patient selection and treatment counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Pathologic Upgrading or Locally Advanced Disease in Early Prostate Cancer Patients Based on Biopsy Gleason Score and PSA: A Population-Based Study of Modern Patients

Purpose: Radiation oncologists rely on available clinical information (biopsy Gleason score and prostate-specific antigen [PSA]) to determine the optimal treatment regimen for each prostate cancer patient. Existing published nomograms correlating clinical to pathologic extent of disease were based on patients treated in the 1980s and 1990s at select academic institutions. We used the Surveillance, Epidemiology, and End Results (SEER) database to examine pathologic outcomes (Gleason score and cancer stage) in early prostate cancer patients based on biopsy Gleason score and PSA concentration. Methods and Materials: This analysis included 25,858 patients whose cancer was diagnosed between 2010 and 2011, with biopsy Gleason scores of 6 to 7 and clinical stage T1 to T2 disease, who underwent radical prostatectomy. In subgroups based on biopsy Gleason score and PSA level, we report the proportion of patients with pathologically advanced disease (positive surgical margin or pT3-T4 disease) or whose Gleason score was upgraded. Logistic regression was used to examine factors associated with pathologic outcomes. Results: For patients with biopsy Gleason score 6 cancers, 84% of those with PSA <10 ng/mL had surgical T2 disease with negative margins; this decreased to 61% in patients with PSA of 20 to 29.9 ng/mL. Gleason score upgrading was seen in 43% (PSA: <10 ng/mL) to 61% (PSA: 20-29.9 ng/mL) of biopsy Gleason 6 patients. Patients with biopsy Gleason 7 cancers had a one-third (Gleason 3 + 4; PSA: <10 ng/mL) to two-thirds (Gleason 4 + 3; PSA: 20-29.9 ng/mL) probability of having pathologically advanced disease. Gleason score upgrading was seen in 11% to 19% of patients with biopsy Gleason 4 + 3 cancers. Multivariable analysis showed that higher PSA and older age were associated with Gleason score upgrading and pathologically advanced disease. Conclusions: This is the first population-based study to examine pathologic extent of disease and pathologic Gleason score upgrading based on clinically available information in modern patients. These data inform the selection of radiation therapy strategies and an understanding of whether prostatectomy alone is likely to be curative for patients with early prostate cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Competing Risk Analysis of Neurologic versus Nonneurologic Death in Patients Undergoing Radiosurgical Salvage After Whole-Brain Radiation Therapy Failure: Who Actually Dies of Their Brain Metastases?

Purpose: To estimate the hazard for neurologic (central nervous system, CNS) and nonneurologic (non-CNS) death associated with patient, treatment, and systemic disease status in patients receiving stereotactic radiosurgery after whole-brain radiation therapy (WBRT) failure, using a competing risk model. Patients and Methods: Of 757 patients, 293 experienced recurrence or new metastasis following WBRT. Univariate Cox proportional hazards regression identified covariates for consideration in the multivariate model. Competing risks multivariable regression was performed to estimate the adjusted hazard ratio (aHR) and 95% confidence interval (CI) for both CNS and non-CNS death after adjusting for patient, disease, and treatment factors. The resultant model was converted into an online calculator for ease of clinical use. Results: The cumulative incidence of CNS and non-CNS death at 6 and 12 months was 20.6% and 21.6%, and 34.4% and 35%, respectively. Patients with melanoma histology (relative to breast) (aHR 2.7, 95% CI 1.5-5.0), brainstem location (aHR 2.1, 95% CI 1.3-3.5), and number of metastases (aHR 1.09, 95% CI 1.04-1.2) had increased aHR for CNS death. Progressive systemic disease (aHR 0.55, 95% CI 0.4-0.8) and increasing lowest margin dose (aHR 0.97, 95% CI 0.9-0.99) were protective against CNS death. Patients with lung histology (aHR 1.3, 95% CI 1.1-1.9) and progressive systemic disease (aHR 2.14, 95% CI 1.5-3.0) had increased aHR for non-CNS death. Conclusion: Our nomogram provides individual estimates of neurologic death after salvage stereotactic radiosurgery for patients who have failed prior WBRT, based on histology, neuroanatomical location, age, lowest margin dose, and number of metastases after adjusting for their competing risk of death from other causes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-118: Dose Verification for Accuboost Applicators Using TLD, Ion Chamber and Gafchromic Film Measurements

Purpose: To verify dose delivered with HDR Accuboost applicators using TLD, ion chamber and Gafchromic film measurements and to examine applicator leakage. Methods: A microSelectron HDR unit was used to deliver a dose of 50cGy to the mid-plane of a 62mm thick solid water phantom using dwell times from Monte Carlo pre-calculated nomograms for a 60mm, 70mm Round and 60mm Skin-Dose Optimized (SDO) applicators respectively. GafChromic EBT3+ film was embedded in the phantom midplane horizontally to measure dose distribution. Absolute dose was also measured with TLDs and an ADCL calibrated parallel-plate ion chamber placed in the film plane at field center for each applicator. The film was calibrated using 6MV x-ray beam. TLDs were calibrated in a Cs-137 source at UW-Madison calibration laboratory. Radiation leakage through the tungsten alloy shell was measured with a film wrapped around outside surface of a 60mm Round applicator. Results: Measured maximum doses at field center are consistently lower than predicated by 5.8% for TLD, 8.8% for ion chamber, and 2.6% for EBT3+ film on average, with measurement uncertainties of 2.2%, 0.3%, and 2.9% for TLD, chamber, film respectively. The total standard uncertainties for ion chamber and Gafchromic film measurement are 4.9% and 4.6% respectively[1]. The area defined by the applicator aperture was covered by 80% of maximum dose for 62mm compression thickness. When 100cGy is delivered to mid-plane with a 60mm Round applicator, surface dose ranges from 60cGy to a maximum of 145cGy, which occurs at source entrance to the applicator. Conclusion: Measured doses by all three techniques are consistently lower than predicted in our measurements. For a compression thickness of 62 mm, the field size defined by the applicator is only covered by 80% of prescribed dose. Radiation leakage of up to 145cGy was found at the source entrance of applicators.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-P-27: Efficient Process for AccuBoost Planning and Treatment Delivery to Minimize Patient Compression Time

Purpose: To implement an efficient and robust process for AccuBoost planning and treatment delivery that can be safely performed by a single Physicist while minimizing patient’s total session time. Methods: Following a thorough commissioning and validation process, templates were created in the brachytherapy planning system for each AccuBoost applicator. Tables of individual and total nominal dwell times for each applicator as a function of separation were generated to streamline planning while an Excel-based nomogram provided by the vendor functions as a secondary verification of the treatment parameters. Tables of surface dose as a function of separation and applicator, along with concise guidance documents for applicator selection, are readily available during the planning process. The entire process is described in a set of detailed Standard Operating Procedures which, in addition to the items described above, include a verbal time-out between the primary planner and the individual performing the secondary verification as well as direct visual confirmation of applicator placement using an articulated mirror. Prior to treatment initiation, a final time-out is conducted with the Radiation Oncologist. Chart documentation is finalized after the patient is released from compression following completion of the treatment. Results: With the aforementioned procedures, it has been possible to consistently limit the time required to prepare each treatment such that the patient is typically under compression for less than 10 minutes per orientation prior to the initiation of the treatment, which is particularly important for APBI cases. This process can be overseen by a single physicist assisted by a dosimetrist and has been optimized during the past 16 months, with 180 treatment sessions safely completed to date. Conclusion: This work demonstrates the implementation of an efficient and robust process for real-time-planned AccuBoost treatments that effectively minimizes the time that the patient is under compression.

60 APPLIED LIFE SCIENCES↗

SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.

60 APPLIED LIFE SCIENCES↗

HYGROSCOPIC MOISTURE SORPTION KINETICS MODELING OF CORN STOVER AND ITS FRACTIONS

Corn stover, a major crop-based lignocellulosic biomass feedstock, is required to be at an optimum moisture content for efficient bioconversion processes. Environmental conditions surrounding corn stover, as in storage facilities, affect its moisture due to hygroscopic sorption or desorption. The measurement and modeling of sorption characteristics of corn stover and its leaf, husk, and stalk fractions are useful from utilization and storage standpoints, hence investigated in this article. A benchtop low-temperature humidity chamber provided the test environments of 20 C, 30 C, and 40 C at a constant 95% relative humidity. Measured sorption characteristics with three replications for each fraction were obtained from instantaneous sample masses and initial moisture contents. Observed sorption characteristics were fitted using exponential, Page, and Peleg models. Corn stover fractions displayed a rapid initial moisture uptake followed by a slower sorption rates and eventually becoming almost asymptotic after 25 h. Sorption characteristics of all corn stover fractions were significantly different (P < 0.0001) but not the effect of temperature (P > 0.05) on these fractions. The initial 30 min of sorption was found to be critical due to peak rates of sorption from storage, handling, and processing standpoints. The Page and Peleg models had comparable performance fitting the sorption curves (R2 = 0.995), however the exponential model (R2 = 0.91) was not found suitable because of patterned residuals. The Arrhenius type relationship (P < 0.05; R2 = 0.80) explained the temperature variation of the fitted sorption model parameters. The Peleg model fitted constants, among the sorption models studied, had the best fit (R2 = 0.93) with the Arrhenius relationship. A developed method of mass proportion, involving individual corn stover fraction dry matter ratios, predicted the whole corn stover sorption characteristics from that of its individual fractions. Sorption characteristics models of individual corn stover fractions and predicted whole corn stover including a nomogram can be used for direct and quick estimation. Developed sorption characteristics find application in several fields of corn stover biomass processing, handling, and transport

09 BIOMASS FUELS↗